Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, September 2 at 2:00 PM EDT

Register Free →

CNIC-64 - NRW 1029, Replace Fire Alarm Assets

Active
Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

General Info

Agency

Department Of The Navy → Navfac WashingtonView Agency

NAICS

N/A

Place of Performance

USA

Set-Aside

NONE

Documents

(0)

No documents available

AI Contract Breakdown

Uniform Contract Format

No contract breakdown available.

Cannot generate Contract Breakdown because no documents were found from this contract's source.

Timeline

Posted

forecast

Ready to pursue this opportunity?

Start your free trial to track this contract, build proposals with AI assistance, and manage your pipeline.

Organization & Contact Information

Show more
AgencyDepartment Of The Navy → Navfac Washington
ContactsNo contacts available
OfficeN/A
Organization / Agency
Department Of The Navy → Navfac Washington
View Agency Profile
Office AddressN/A
ContactsNo contact information available

Full Description

Show more
LS Techs responded to requests for service at NSA Bldg 64 for intermittent troubles on the fire alarm panel. See SA-70065 and SA-69109 for details. LS Systems proposes to return to complete the remaining troubles on the fire alarm system. 1) Level 3 Zone 1 Room 310 Unit Smoke Detector Missing N1L2S112. Checked smoke detector and need a “ASD-PL3”. 2) Level 6 Corridor by Room 602 Smoke Detector Missing N7L2S053. Checked smoke detector and need a “ASD-PL3”. 3) Level 2 Zone 1 Room 237 Unit Smoke Detector Missing N1L2B063. Checked the sounder base and need a “B200S”. 4) Level 5 Text Sign Announcement Missing N7L1M019. Looked on the 5th floor and didn’t find the module. From the program it looks like Node 7 is in the 5th floor and the module should be close to the panel. Need a “AOM-2RF” for this. 5) Room 508 Unit Smoke Detector L1S116 ASD-PL3 6) Room 508 Unit Smoke Detector Base L1B116 B200S 7) Room 418 Unit Smoke Detector Base L1B039 B200S 8) Room 237 Unit Smoke Detector Base L2B063 B200S 9) 6th Floor Corridor by 602 Smoke Detector L2S053 ASD-PL3 10) Room 310 Unit Smoke Detector L2S112 ASD-PL3 This quote includes -Delivery of any needed material -Applicable taxes This quote excludes the following unless noted elsewhere on the proposal Material and Installation of Conduit, Pipe, Deck Work, Boxes and Fittings Lifts and Hoists Vertical Core Drilling On-Site Lockable Storage Facility Ceiling Tiles and Ceiling Grid Repairs Horizontal Core Drilling Fees associated with obtaining electronic CAD files Permit fees Engineer's plan review & stamping fees Any modification to existing base building FACP or Annunciator (IF APPLICABLE) Payment & Performance Bonds Patching and Painting Firestopping / Caulking (excluding existing penetrations) Fire Watch 120VAC and Fused Disconnect Switch Correction of Wiring Faults and field devices errors Caused by Others Floor Coverings for Lifts and Hoists U.L. Central Station Monitoring Services

More opportunities from Department Of The Navy → Navfac Washington

Same awarding agency