Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, October 28 at 2:00 PM ET

Register Free →

This Sources Sought opportunity from Department Of Commerce was posted on June 21, 2017. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

Design of Circuit Breaker Testing/Replacement

Closed
SB1341-17-RQ-0520Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 541330
New
SLED
Interested parties are invited to submit a proposal in accordance with this request to Mayor Lori Tucker, City of Booneville, 203 N Main Street Booneville, MS 38829, no later than 10:00 a.m. on October 21, 2026. Proposals must be submitted in a sealed
Solicitation # 3170036767
The City of Booneville, Mississippi, is soliciting proposals for professional engineering services to support the application and implementation of the ARC Booneville Heartland Pump Station project. The scope of work involves replacing the aging Heartland Wastewater Pump Station and associated pressure sewer lines to increase wastewater capacity and improve system reliability to support industrial and commercial growth. The selected engineer will be responsible for a comprehensive range of services, including environmental and engineering design, preparing project cost estimates, managing the bidding process, and providing construction engineering and inspection through project closeout. All work must comply with federal, state, and local laws and regulations. Proposals must be submitted in a sealed envelope marked Proposal for Engineering Services/Booneville Heartland Pump Station and delivered to Mayor Lori Tucker at 203 N Main Street, Booneville, MS 38829, by 10:00 a.m. on October 21, 2026. Submissions must include eight copies of the proposal. The contract will be awarded on a fixed-price basis to the qualified firm or individual that achieves the highest cumulative score based on a weighted evaluation of staff qualifications (40 points), previous project experience (40 points), and capacity for performance (20 points). The City encourages submissions from minority-owned and women-owned businesses.
MPTAP

POSTED

about 16 hours ago

DEADLINE

in about 8 hours

General Info

Contract Value

$110,312.36

NAICS

541330 - Engineering Services

Place of Performance

NIST Boulder Campus, BOULDER, CO, 80305, USA

Set-Aside

SBA

Award Issued Date

Documents

2

AE_Sources_Sought_NB190000-17-00848.doc

DOC

Sources_Sought__SB1341-17-RQ-0193.pdf

PDF

AI Contract Breakdown

Uniform Contract Format

Contract not broken down yet

CLEATUS splits the solicitation into Uniform Contract Format (UCF) sections: scope, pricing, deliverables, and evaluation criteria.

Timeline

2 updates
PhaseClosed
Posted

Sources Sought

Notice updated

Response deadline changed from Jun 15, 2017 to Jun 30, 2017. The notice description changed.

Notice updated

The notice description changed. The point of contact changed.

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Start your free trial to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Commerce Nist
Contacts1 person available
OfficeGAITHERSBURG, MD, 20899, USA
Organization / AgencyDepartment Of Commerce Nist
Office AddressGAITHERSBURG, MD, 20899, USA
Contacts
Patricia BullingtonContracting Officer

Full Description

Show more
Design of Circuit Breaker Testing/Replacement NIST in Boulder, Colorado 80305 NB190000-17-00848 In accordance with (IAW) Federal Acquisition Regulation (FAR) 15.201(c)(3) this is a SOURCES SOUGHT FOR MARKET RESEARCH. This notice is a request for information to provide data for planning purposes only and does not constitute an Invitation for Bids, a Request for Proposals, a Solicitation, a Request for Quotes, or an indication the Government will contract for the services contained in this Sources Sought. This request is not to be construed as a commitment on the part of the Government to award a contract, nor does the Government intend to pay for any information submitted as a result of this notice. The Government does not reimburse respondents for any cost associated with this source sought or reimburse expenses incurred to interested parties for preparing a response as a result of this posting. Any responses received will not be used as a proposal. Respondents will not be notified of the Sources Sought evaluation results, nor will questions be addressed by the Government; however, an industry or small business conferences will be scheduled to exchange information about this future acquisition. THIS IS A SOURCES SOUGHT NOTICE ONLY. THIS IS NOT A REQUEST FOR PROPOSALS. A SOLICITATION OR DRAWINGS ARE NOT AVAILABLE AT THIS TIME. The U.S. Department of Commerce, National Institute of Standards and Technology (NIST), is soliciting for capability statements from all interested parties to design services for Building 1 center spine (which include the library and auditorium), Building 1 wing 1 (including annex C and D and the IONS lab switchgear), and wing 2 at NIST in Boulder, Colorado. The North American Industry Classification System (NAICS) code for the proposed acquisition is 541330, Engineering Services, and the Small Business size standard is $15.0 million. The solicitation is planned to be posted in the summer of 2017 with a FIRM-FIXED-PRICE award anticipated for the summer of 2017 (fiscal year 2017). IAW FAR 36 the estimated price range for this project is between $25,000.00 and $100,000.00. Completion time for this project is estimated at 120 calendar days after award. The purpose of this synopsis is to gain knowledge of interest, capabilities and qualifications of various members of industry, to include the Small Business Community: Small Business, Section 8(a), Historically Underutilized Business Zones (HUB-Zone), Service-Disabled Veteran-Owned Small Business (SDVOSB). The Government must ensure there is adequate competition among the potential pool of responsible Contractors. Small business, Section 8(a), HUBZone, and SDVOSB businesses are highly encouraged to participate. This requirement is currently unfunded and this Sources Sought is issued solely for information and planning purposes - it does not constitute a Request for Proposal (RFP) or a promise to issue an RFP in the future. This sources sought does not commit the Government to a contract for any supply, service, or construction whatsoever. Furthermore, the National Institute of Standards and Technology is not at this time seeking proposals and will not accept unsolicited proposals. Recipients of this sources sought are advised that the U.S. Government will not pay for any information or administrative costs incurred as a result of this sources sought; all costs associated with this sources sought will be solely at the interested party's expense. No award will be made under this sources sought until funds are available and a solicitation is issued. The Government reserves the right to cancel this sources sought at any time. In the event the Government cancels this sources sought, the Government has no obligation to reimburse the recipient of this information for any costs. Any solicitation will be issued as a Request for Proposal (RFP) which will be 100% set aside for small business firms. In Accordance with (IAW) FAR 4.1102, System for Award Management (SAM), contractor(s) shall be registered in SAM prior to award. Offerors may obtain information on registration at https://www.sam.gov. Contractors that are Debarred, Suspended, or Proposed for Debarment are excluded from receiving contracts. Agencies also shall not consent to subcontract with these contractors. The AE shall provide drawings ONLY that provide detailed step by step instructions to test and inspect all circuit breakers for all panel boards, and switchgear per NETA MTS 2007 standards in Building 1 center spine (which include the library and auditorium), Building 1 wing 1 (including annex C and D and the IONS lab switchgear), and wing 2. The testing will consist of switchgear breakers, and panel board breakers. For switchgear breakers ONLY, in the event testing would cause undue outage times, circuit breaker swaps with a National Institute of Standards and Technology (NIST) accepted rebuilt circuit breaker is allowed. For panel boards, at the determination of NIST personnel, replacement of the entire panel board, panel board internal components (busbars/circuit breakers with the original enclosure maintained) and/or circuit breaker replacement are allowed if undue outage time is be required. In addition, the contractor shall provide recommendations on the replacement of feeder and branch circuit wiring found to be hazardous. This will require removal of covers of panel boards on live equipment, therefore an electrician may be required. As part of the drawings, NEC required labels identifying the distribution point name, feeder size, calculated fault current, date of calculation, feeder source, and arc flash calculations (SKM powertools format) meeting NFPA 70E 2015 requirements shall be provided for all electrical distribution equipment (including but not limited to switchgear, panel boards, bus duct breakers, and three phase disconnects) that is identified for testing or replacement and any distribution equipment downstream of such equipment. As part of the labels, all information for such label shall be on the same sheet, even if it requires duplication of information on more than one drawing. The intent of the drawings is to provide information such that the construction contractor does not need to cross reference information found on other drawing sheets. In addition, a sequence of events that can walk a construction contractor step by step through the process, identification of off hours (weekend) work, including anticipated shutdown times is required. A one line for each building is required as part of the drawing set and will be created from scratch. It is known panel board covers will need to be removed. In addition, updated panel schedules in regards to number and size of circuit breakers, are required. The AE shall use infinite bus calculation from the transformer serving the building for all fault and arc flash calculations. Furthermore, arc flash calculations shall be based on the equipment specified on the drawings with a note that the contractor is responsible for any recalculation cost if equipment substitutions are made. An example drawing is provided by NIST. The AE shall utilize the existing format. Under no circumstances shall the AE create any new layers or new symbols unless approved by NIST. The final drawing shall have the same look and feel of the sample drawing. Any specifications shall be as notes on the drawings. Any specification for equipment shall be identified on the drawings by manufacturer and part number. In addition to the drawings, the AE shall provide a separate cost opinion for the circuit breaker service for each building. This cost opinion shall identify all assumptions and sources for the cost estimate. Drawings shall be prepared using AutoCAD, and files shall be compatible with AutoCAD 2015. Arc Flash calculations shall be performed using SKM powertools format as part of this project. IEEE 1584 limited energy clause is allowed. Prior Government contract work is not required for submitting a response under this sources sought synopsis but encouraged. It is important to note that in accordance with FAR 52.219?14, which will be incorporated into any resultant contract, requires the Prime Contractor to perform services under the contract equivalent to 50% or more of the contract value in personnel costs throughout the life of the contract. In accordance with FAR 36.209 Construction contracts with architect-engineer firms. No contract for the construction of a project shall be awarded to the firm that designed the project or its subsidiaries or affiliates, except with the approval of the head of the agency or authorized representative. In addition to information your firm feels pertinent to provide please provide the following but limited to twenty-five (25) pages: 1. Your firm's name, address and DUNS number for reference in the System for Award Management (SAM). In addition to the points of contact information found in your firms SAM registration (website found at www.sam.gov) please provide any additional points of contact information. 2. All interested firms should submit one (1) electronic copy of a recently completed Standard Form (SF) 330, Architect?Engineer Qualifications, PART II ONLY, to the Contracting Officer (as noted below) no later 2:00 PM., Mountain Time (MT) on June 30, 2017. When completing your SF 330 PART II be sure to include key personnel of subs and consultants. A cover letter, or otherwise identified, may be submitted that is no more than two (2) pages in length. You may submit supplementary information that illustrates your firm's ability to meet the criteria described in the sources sought. The SF 330 PART II shall not exceed a combined total of twenty-five (25) 8.5"x11" single sided pages. 3. The SF 330 PART II must be formatted using a Times New Roman 12-point (pt.) normal font (no reduction permitted), single-spaced with 1-inch margins all around, and formatted for standard 8.5 x 11-inch paper. All pages should be numbered with section and page numbers. When foldout pages are used, they must not exceed 11 x 17 inches and will be counted as 1 page. Drawings may be provided separately and may be any size but should be folded to approximately 8.5 x 11-inch standard size and will count as 1 page. Graphs shall be presented in no smaller than a 10-pt. font and should contain a grid, which allows values to be read directly from the graph to the same accuracy that a 10 x 10 to the - inch grid provides. Graphic resolution, including such data as tables or charts, should be consistent with the purpose of the data presented. A pre-proposal meeting / walkthrough will be scheduled and listed in the solicitation. Attendance is not mandatory, but is strongly encouraged. SITE VISIT A pre-proposal meeting / walkthrough will be scheduled and listed in the solicitation. Attendance is not mandatory, but is strongly encouraged. SUBMITTAL INSTRUCTIONS: All interested parties shall submit electronic and written response packages limited to no more than twenty-five (25) pages no later than June 30, 2017 at 2:00 PM., M.T. Send electronic submissions to patricia.bullington@nist.gov. Mail SF 330s shall be addressed to the following: U.S. Department of Commerce National Institute of Standards and Technology (NIST) Attention: Patricia Bullington (Contracting Officer) 325 Broadway, Building 111 Room 110 Boulder, CO 80305-3325 All questions must be submitted in writing, addressed to: Patricia Bullington Contracting Officer, at patricia.bullington@nist.gov no later than June 25, 2017, by 02:00 P.M. Mountain Standard Time. No telephone calls will be returned. The issuance of a solicitation will be determined if funding becomes available for this project. This Source Sought will CLOSE Friday, June 30, 2017 at 2:00 PM, MT. Contracting Office Address: NIST Campus Bldg. 110 325 Broadway Boulder, CO 80305 United States Place of Performance: NIST Campus Bldg. 1 325 Broadway Boulder, CO 80305 United States Primary Point of Contact.: Name: Patricia Bullington, Contracting Officer Email: patricia.bullington@nist.gov Phone: (303) 497-3106

More opportunities from Department Of Commerce Nist

Same awarding agency

NAICS: 236210
New
Federal
Building 215 Clean Room HEPA Filter Replacement
Solicitation # RFI-195000-26-00181
The National Institute of Standards and Technology is conducting market research through a Request for Information for the Building 215 Advanced Measurement Laboratory cleanroom repair and HEPA filter replacement project in Gaithersburg, Maryland. This initiative follows a previous solicitation that failed to produce an acceptable offer, prompting NIST to reassess its acquisition strategy and seek industry feedback on constructability, cost, and schedule feasibility. The project scope involves the modernization of an 1,800 square meter facility, including the replacement of approximately 1,200 HEPA filters, 70 VAV terminal units, and 54 airflow monitoring devices, as well as the installation of 32 exhaust air control valves and associated ductwork repairs, testing, and recertification. A critical component of the project is the proposed phasing plan, which aims to minimize research disruptions by utilizing 19 construction phases, including 18 critical cleanroom outage phases. Each critical outage is currently envisioned as a nine-day window starting Friday evening and requiring 24/7 operations to achieve ready-for-re-occupancy by the following Monday morning. NIST is specifically requesting rough-order-of-magnitude cost estimates and industry input on whether this aggressive outage schedule is realistic or if it creates prohibitive risks and costs. Responses, including company experience and recommendations for improving competition and project execution, are due by October 14, 2026.
Industrial Building Construction

POSTED

2 days ago

DEADLINE

in 12 days
View Details

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS