Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, September 2 at 2:00 PM EDT

Register Free →

DOME CAP,VALVE

Active
N0010426QND09Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

AI Contract Overview

Show more

This contract pertains to the supply of a dome cap for a valve assembly, designated as SPECIAL EMPHASIS LEVEL I material due to its critical function in a shipboard system, where failure could result in catastrophic consequences including loss of life or vessel. The item must conform strictly to Vacco Valves drawing V3E10041 and welding information document WI-S1E10033, with all materials being SAE AMS-QQ-S-763, Type 304 stainless steel. Rigorous certification and traceability protocols are mandated from raw material through final assembly, requiring unique heat-lot traceability markings, 100% inspection of material certifications, and 100% verification of chemical and mechanical properties. All welds must be performed by qualified personnel using approved procedures submitted for prior Navy review, with radiographic testing required on all weldments and acceptance criteria aligned with MIL-STD-2035 and S9074-AR-GIB-010A/278. The contractor must maintain an ISO-9001 quality system with ISO-10012 and ISO/IEC 17025 calibration compliance, and a government quality assurance representative from DCMA will conduct inspections at source. Electronic submission of certifications and test reports is mandatory via WAWF to Portsmouth Naval Shipyard, with no material permitted to ship without formal acceptance. The contract includes mandatory compliance with Navy-specific requirements including mercury-free materials, electronic signatures on certifications, and stringent controls on subcontractor quality and traceability. The contract is issued under Emergency Acquisition Flexibilities and is rated for national defense priority under the Defense Priorities and Allocations System, requiring bilateral execution with contractor acceptance prior to award. Delivery is FOB destination, with payment instructions tied to the WAWF system and specific government identifiers. All documentation, including welding procedures, radiographic films, test reports, and certificates of compliance, must be submitted electronically in Adobe PDF format and verified against contract specifications prior to release for shipment. The contract prohibits any unauthorized alterations or deviations from specifications without formal written approval from the Contracting Officer, and all waiver or deviation requests must be classified and submitted via ECDS with full justification. The warranty period extends one year from date of delivery, and the product is subject to zero defect acceptance sampling under ANSI/ASQ Z1.4 for final lot inspection. The contract mandates full compliance with all referenced military and industry standards, including FED-STD-H28

General Info

Supply of critical dome cap per Navy specs with full traceability, weld inspections, ISO compliance, and zero-defect acceptance under defense priority.

Agency

Department Of Defense → Navsup Weapon Systems Support MechView Agency

NAICS

332919 - Other Metal Valve and Pipe Fitting ManufacturingView NAICS

Place of Performance

PA

Set-Aside

NONE

Documents

(2)

Amendment 0001 to Solicitation N00104-26-Q-ND09

PDFamendment

NO0014-26-Q-NOD9 RFQ for Dome Cap, Valve

PDFrfq

AI Contract Breakdown

Uniform Contract Format

Sign up to view the full breakdown with detailed analysis of each section.

Timeline

PhaseSolicitation
Posted

Solicitation

Response Deadline

Submission deadline

Response Deadline

Ready to pursue this opportunity?

Start your free trial to track this contract, build proposals with AI assistance, and manage your pipeline.

Organization & Contact Information

Show more
AgencyDepartment Of Defense → Navsup Weapon Systems Support Mech
Contacts1 person available
OfficeMECHANICSBURG, PA, 17050-0788, USA
Organization / Agency
Department Of Defense → Navsup Weapon Systems Support Mech
View Agency Profile
Office AddressMECHANICSBURG, PA, 17050-0788, USA
Contacts
Electronic Mail

Full Description

Show more
CONTACT INFORMATION|4|N744.1|WVD|771-229-3917|brittany.a.langletz.civ@us.navy.mil| ITEM UNIQUE IDENTIFICATION AND VALUATION (JAN 2023)|19|||||||||||||||||||| HIGHER-LEVEL CONTRACT QUALITY REQUIREMENT (DEC 2014)|1|See specifications C and E| INSPECTION OF SUPPLIES--FIXED-PRICE (AUG 1996)|2||| INSPECTION/ACCEPTANCE POINT|6|TBD|DCMA NSEO S4306A|||TBD|DCMA NSEO S4306A| GENERAL INFORMATION-FOB-DESTINATION|1|B| WIDE AREA WORKFLOW PAYMENT INSTRUCTIONS (JAN 2023)|16|Stand-Alone Receiving Report - Certifications Combo - Receiving Report & Invoice - Material|N/A|TBD|N00104|TBD|N39040 - Certifications, S4306A - Material|N50286|TBD|TBD|N/A|N/A|N39040 - Certifications|N/A|N/A|S ee DD Form 1423|PORT_PTNH_WAWF_NOTIFICATION@NAVY.MIL| NAVY USE OF ABILITYONE SUPPORT CONTRACTOR - RELEASE OF OFFEROR INFORMATION (3-18))|1|WSS| MANDATORY USE OF WORKFLOW PRO (WFP) MOD ASSIST MODULE|1|| INTEGRITY OF UNIT PRICES (NOV 2021)|1|| EQUAL OPPORTUNITY FOR VETERANS (DEV 2026-O0040)(FEB 2026)|4||||| WARRANTY OF SUPPLIES OF A NONCOMPLEX NATURE (JUNE 2003)|6|One yar from date of delivery|One year from date of delivery||||| EQUAL OPPORTUNITY FOR WORKERS WITH DISABILITIES (DEV 2026-O0040)(FEB 2026)|4||||| TRANSPORTATION OF SUPPLIES BY SEA (OCT 2024)|2||| SMALL BUSINESS SUBCONTRACTING PLAN (DOD CONTRACTS)-BASIC (DEV 2026-O0037)(FEB 2026))|2||| WARRANTY OF DATA-BASIC (DEVIATION 2026-O0035) (FEB 2026)|2||| SECURITY PROHIBITIONS AND EXCLUSIONS (CLASS DEVIATION 2026-O0025)(FEB 2026)|7|||||||| ALTERNATE A, ANNUAL REPRESENTATIONS AND CERTIFICATIONS (DEVIATION 2026-O0043)(FEB 2026))|13|||||||||||||| NOTICE OF PRIORITY RATING FOR NATIONAL DEFENSE, EMERGENCY PERPARDENESS, AND ENRGY PROGAM USE (APRIL 2008))|2||X| 1. This requirement is pursuant to Emergency Acquisition Flexibilities (EAF). 2.The resultant award of this solicitation will be issued bilaterally, requiring the contractor?s written acceptance prior to execution. 3.All contractual documents (i.e. contracts, purchase orders, task orders, delivery orders, and modifications) related to the instant procurement are considered to be 'issued' by the Government when copies are either deposited in the mail, transmitted by facsimile, or sent by other electronic commerce methods such as email. The Government's acceptance of the contractor's proposal constitutes bilateral agreement to ?issue? contractual documents as detailed herein. 4.Any contract awarded as a result of this solicitation will be ;DO; certified for national defense under the Defense Priorities and Allocations System (DPAS). Provision 52.211-14, Notice of Priority Rating for National Defense, Emergency Preparedness, and Energy Program Use, shall be inserted in solicitations when the contract to be awarded shall be a rated order. 5.Data Item A001 (Inspection and Test Plan) may be waived if already on file at NAVSUP WSS Mechanicsburg. 6.The option provision is included in the event the Government has an additional requirement 365 Days after issuance of the award. This will authorize the Government to add the additional quantity, up to the percentage cited, to the order, via modification without having to re-solicit. 7. It is requested that pricing be submitted on the option provision. \ 1. SCOPE 1.1 The material covered in this contract/purchase order will be used in a crucial shipboard system. The use of incorrect or defective material would create a high probability of failure resulting in serious personnel injury, loss of life, loss of vital shipboard systems, or loss of the ship itself. Therefore, the material has been designated as SPECIAL EMPHASIS material (Level I, Scope of Certification, or Quality Assured) and special control procedures are invoked to ensure receipt of correct material. 2. APPLICABLE DOCUMENTS 2.1 Order of Precedence - In the event of a conflict between the text of this contract/purchase order and the references and/or drawings cited herein, the text of this contract/purchase order must take precedence. Nothing in this contract/purchase order, however, must supersede applicable laws and regulations unless a specific exemption has been obtained. 2.2 Applicable Documents - The document(s) listed below form a part of this contract/purchase order including modifications or exclusions. 2.2.1 Specification Revisions - The specification revisions listed under "Documents References" below are the preferred revision. Older and/or newer r evisions are acceptable when listed within Contract Support Library Reference Number CSD155 in ECDS (Electric Contractor Data Submission) at: ht tps://register.nslc.navy.mil/. This is to allow Contractors to use certain acceptable older specification revisions to purge their existing stock of material certified to those older revisions or to use newer specification revisions when material is certified to newly released revisions,without requiring the submittal of waiver/deviation requests for each specification revision on every contract. Revisions of specifications reflecting editorial and/or re-approval (e.g. E2009, R2014, etc.) are considered inconsequential, but are acceptable when their revisions are listedwithin CSD155 or elsewhere within this contract. 2.2.2 "Document References" listed below must be obtained by the Contractor. Ordering information is included as an attachment to this contract/purchase order. 2.2.3 The documents and drawings listed below under DRAWING NO. are not provided with this Contract/Purchase order. DRAWING NO CAGE REV DISTR CD ;V3E10041 99517 G B WI-S1E10033 99517 B B; DOCUMENT REF DATA=FED-STD-H28 | | |B |190424|A| | | DOCUMENT REF DATA=FED-STD-H28 |0020| |B |941221|A| |01| DOCUMENT REF DATA=ANSI/ASQ Z1.4 | | | |080101|A| | | DOCUMENT REF DATA=MIL-STD-792 | | |F |230223|A| |01| DOCUMENT REF DATA=MIL-STD-2035 | | |A |950515|A| | | DOCUMENT REF DATA=ISO_9001 | | | |081115|A| | | DOCUMENT REF DATA=ISO10012 | | | |030415|A| | | DOCUMENT REF DATA=ISO/IEC 17025 | | | |050515|A| | | DOCUMENT REF DATA=MIL-I-45208 | | |A |810724|A|1 | | DOCUMENT REF DATA=MIL-STD-45662 | | |A |880801|A| | | DOCUMENT REF DATA=SAE AMS-QQ-S-763 | | |D |150301|A| | | DOCUMENT REF DATA=ANSI/NCSL Z540.3 | | | |130326|A| | | DOCUMENT REF DATA=0900-LP-001-7000 | | | |810101|C| |01| DOCUMENT REF DATA=S9074-AQ-GIB-010/248 | | |1 |191112|A| | | DOCUMENT REF DATA=T9074-AS-GIB-010/271 | | |1 |140911|A| | | DOCUMENT REF DATA=S9074-AR-GIB-010A/278 (CHG A) | | | |130214|A| | | 3. REQUIREMENTS 3.1 ;Dome cap for regulator assembly to be in accordance with Vacco Valves drawing V3E10041, item 17 and Plug welded to Dome Cap, with VACCO Welding Information Document WI-S1E10033, except as amplified or modified herein.; 3.2 Material for Parts Requiring Certification - Quantitative chemical and mechanical analysis is required for the parts listed below unless specifically stated otherwise: Part - ;Dome cap; Material - ;SAE AMS-QQ-S-763, type 304; Part - ;Plugs (welded in dome cap); Material - ;SAE AMS-QQ-S-763, type 304; 3.3 Testing Certification - Certifications are required for the following tests on the items listed below. Additional testing on other piece parts (if any) per applicable drawings and specifications is still required, but certifications are only required as listed below. Test - Non-Destructive Tests Item - ;Weld Repair (as applicable); Performance - Per applicable fabrication specification Acceptance - Per applicable fabrication specification Test - 5x Visual Magnification or Dye Penetrant Inspection (root layer) Item - Weldments Performance - T9074-AS-GIB-010/271 Acceptance - MIL-STD-2035 Test - Visual and Dye Penetrant Inspection (final layer) Item - Weldments Performance - T9074-AS-GIB-010/271 Acceptance - MIL-STD-2035 Test - Intergranular Corrosion Test (Only for SAE-AMS-QQ-S-763, Classes 304-condition A, 304L, 316-condition A, 316L, 317-condition A, 321 and 347 material. Test must be performed prior to fabrication/machining) Item - ;Item 17 and Plug Welded to Dome Cap of Drawing V3E10041; Performance - SAE-AMS-QQ-S-763 Acceptance - SAE-AMS-QQ-S-763 3.4 Radiography is required on ;weldments and must be identified to the weld joint; . 3.5 Welding or Brazing - When welding, brazing, and allied processes are required, as invoked by Section C paragraph 3 requirements, they must be in accordance with S9074-AR-GIB-010A/278, 0900-LP-001-7000 for brazing of piping and pressure vessel applications, or S9074-AQ-GIB-010/248 for brazing of other applications. For all production and repair welding and brazing personnel and procedures must be qualified under S9074-AQ-GIB-010/248 or 0900-LP-001-7000, as applicable. Procedures and Qualification Data must be submitted for review and approval prior to performing any welding or brazing. 3.6 Internal Threads - All internal threads must be formed by cutting. Cold forming of internal threads is not acceptable. 3.7 Thread Inspection Requirements - All threads on threaded parts must be inspected using appropriate inspection methods, inspection systems, and inspection gages/instruments in accordance with FED-STD-H28 series. Substitution of thecommercial equivalent inspection in accordance with ASME B1 series is acceptable. 3.7.1 System 21 of FED-STD-H28/20 must be used as a minimum inspection requirement for threads when the design drawing or design specification does not specify an inspection requirement. 3.7.2 For Navy and Shipyard drawings, system 21 of FED-STD-H28/20 may be substituted for System 22 without further Navy approval when the design drawing invokes System 22 and does not cite governing specifications that specifically require system 22. System 22 of FED-STD-H28/20 must be used when the drawing references other governing specifications that specifically require System 22, such as certain thread types of MIL-DTL-1222. 3.7.3 A written request for concurrence must be submitted when utilizing alternative measuring equipment or measuring systems not applicable to the specified inspection system. 3.8 O-ring grooves and mating sealing surfaces must be inspected per the contractually invoked drawings or specifications. When the drawings or specifications do not provide specific defect criteria or state that no defects are allowed, the General Acceptance Criteria (GAC) standard must be used for inspecting O-ring grooves and mating sealing surfaces only. Repairs to sealing surfaces and O-ring grooves with unacceptable defects may be accomplished within the limits of the size and tolerances provided in the applicable drawing. Repairs thatwould exceed these limits require approval (including final dimensions). The data that is red lined (crossed out) is excluded from the GAC for this contract and is not to be used for acceptance or rejection criteria. The GAC document is identified as Contract Support Library Reference Number CSD008 at https://register.nslc.navy.mil/ 3.9 NAVSEA 0948-LP-045-7010 - Any applicable requirements of NAVSHIPS 4410.17,NAVSEA 0948-LP-045-7010, or 0948-045-7010 which the contractor must meet are included in this contract/purchase order. The above documents are for GovernmentUse Only. Further application of the above documents is prohibited.prohibited. 3.9.1 Marking of material with a Material Designator per the Drawing is also prohibited, with the exception of Fasteners. Fasteners must be marked with a Material Symbol/Designator as specified elsewhere in this contract. 3.10 Configuration Control - The Contractor must maintain the total equipment baseline configuration. For items of proprietary design, Contractor drawings showing the latest assembly configuration must be provided to the Government in electronic (C4) format. Definitions are provided elsewhere in the Contract/Purchase Order. 3.10.1 Waivers/Deviations - All waivers and deviations, regardless of significance or classification require review and approval by the Contracting Officer. Waivers and Deviations must be designated as Critical, Major, or Minor. The Contractor must provide a copy of this request to the QAR. Requests must include the information listed below. a. A complete description of the contract requirement affected and the nature of the waiver/deviation (non-conformance), including a classification of Critical, Major, or Minor. b. Number of units (and serial/lot numbers) to be delivered in this configuration. c. Any impacts to logistics support elements (such as software, manuals, spares, tools, and similar) being utilized by Government personnel or impacts to the operational use of the product. d. Information about remedial action being taken to prevent reoccurrence of the non-conformance. 3.10.2 All requests for Waivers/Deviations on NAVSUP-WSS Contracts must be submitted to the NAVSUP WSS Contracting Specialist via eMail. 3.10.3 ECPs - The Government will maintain configuration control and change authority for all modifications or changes affecting form, fit, function, or interface parameters of the Equipment and its sub-assemblies. The Contractor must submit an Engineering Change Proposal (ECP) for any Class I or II changes that impact the Equipment covered by this contract. ECPs must be prepared in Contractor format, and must include the following information: a. The change priority, change classification (Class I or Class II), and change justification. b. A complete description of the change to be made and the need for that change. c. A complete listing of other Configuration Items impacted by the proposed change and a description of the impact on those CIs. d. Proposed changes to documents controlled by the Government. e. Proposed serial/lot number effectivities of units to be produced in, or retrofitted to, the proposed configuration. f. Recommendations about the way a retrofit should be accomplished. g. Impacts to any logistics support elements (such as software, manuals, spares, tools, and similar) being utilized by Government personnel in support of the product. h. Impacts to the operational use of the product. i. Complete estimated life-cycle cost impact of the proposed change. j. Milestones relating to the processing and implementation of the engineering change. 3.11 Mercury Free - Mercury and mercury containing compounds must not be intentionally added or come in direct contact with hardware or supplies furnished under this contract. Mercury contamination of the material will be cause for rejection. 3.12 Certificate of Compliance - (SPECIAL EMPHASIS MATERIAL) The Contractor must prepare and submit a certificate of compliance certifying that the items/components furnished under this contract comply with the requirements of the procurement document, including any/all invoked specifications and drawings. ^ QUALITY ASSURANCE REQUIREMENTS ^ 3.13 See CDRL DI-MISC-80678 (Test Certification) - A statement of tests performed, listing the pieces tested must be furnished along with a copy of the test results. Certification must include the contractor's name, address and date, quantity inspected, identified to the contract/purchase order and item number, and the Contractor's or authorized personnel's signature. Test certifications must reference the standard/specification, including the revision, to which the testing was performed and the acceptance criteria used. Test procedure numbers may also be referenced on test reports. Test reports on weldments must be identified to weld joint and layer. 3.14 See CDRLs DI-MISC-80875 (welding procedures) and DI-MISC-80876 (weld procedure qualification data) - When production or repair welding is required, the applicable welding procedure(s) and qualification data must be submitted for review and approval. In addition, the CONSUMED WELD METAL C of C as defined below must be submitted as part of the certification OQE package submitted by the Contractor. Note: These requirements do not apply to tack/spot welds when the conditions of Section 4.2.1.1 of S9074-AR-GIB-010A/278 are met. 3.14.1 Approval of the Contractor's qualification data must be obtained prior to performing any welding (production or repair). 3.14.2 If the Contractors qualification data has previously been approved by the Navy for other contracts, a copy of the original approval letter may be submitted along with the procedures and qualification data report to expedite the approval process. The approval letter must reference the applicable welding procedure and qualification data report identification/number. Prior approval does not guarantee acceptance for this or any future contracts. As far as practical, all procedures for the contract must be submitted at the same time. Welding procedures and qualification data must be submitted in a commercially available electronic format such as Adobe Acrobat PDF. The contractor must state the applicability of each weld procedure and qualification data submitted, citing the drawing number and pieces to be welded. (i.e. "WP-123 and QD-123 are submitted for the weld joint between pieces 1 and 2 on drawing ABC." WP-456 and QD-456 are submitted for the hardfacing of piece 3 on drawing XYZ.") 3.14.3 The PCO's authorization for the use of weld procedure(s) and qualification data for the specific application as submitted does not mitigate the vendors responsibility to comply with the requirements of S9074-AQ-GIB-010/248, S9074-AR-GIB-010A/278, and the contract. 3.14.4 Authority for the repair of Special Repairs in castings, the repair of wrought material, or the repair of forged material must be obtained via request for waiver from the Procurement Contracting Officer. This request must describe the defect; including size, depth, location, and a description of the proposed repair. Repairs deemed minor or nominal in accordance with S9074-AR-GIB-010/278 can be made at contractor discretion in accordance with S9074-AR-GIB-010/278 requirements; however, Weld Procedure Specification (WPS) and Procedure Qualification Record (PQR) submittals are still required. This request for NAVSUP-WSS Contracts must be submitted via the Electronic Contractor Data Submission (ECDS) application. 3.14.5 Any new procedure qualification performed under this Contract will require the vendor to provide a minimum 72 hour notification to DCMA with an offer to observe the welding of the test assemblies. The 72 hour time limit may be modified upon mutual agreement between the vendor and DCMA. 3.14.6 When drawings require hardfacing surface Iron or Nickel content not to exceed 5%, the contractor must verify surface Iron or Nickel content by performing chemical testing as defined by the applicable drawing. The chemical test results must be submitted as part of the qualification data. 3.14.7 Additional qualification requirements for production hardfacing thickness less than 1/8-inch: Macro-etch (or legible photomacrographs clearly showing the fusion area) must be submitted for review and show consistent, minimized dilution. All essential elements and any elements not listed in S9074-AQ-GIB-010/248 that influence dilution must be in the qualification data and weld procedure, with strict limits placed on each essential element. 3.14.8 Preparation and retention of weld records is required, as specified by paragraph 4.1.3 of S9074-AR-GIB-010A/278. 3.14.9 When production or repair welding is required on titanium materials, the applicable fabrication plan, facilities procedure, training plan, and active welder qualification must also be submitted for review and approval. 3.14.10 If the contractor's fabrication plan, facilities procedure, training plan, or active welder qualification has previously been approved by the Navy for other contracts, a copy of the original approval letter may be submitted along with the applicable documentation to expedite the approval process. The approval letter must reference the applicable documentation. Prior approval does not guarantee acceptance for this or any future contracts. The contractor's fabrication plan, facilities procedure, training plan, and active welder qualification must be submitted at the same time as the applicable welding procedure(s) and weld procedure qualification data. All documentation must be submitted in a commercially available electronic format, such as Adobe Acrobat PDF. 3.14.11 See CDRL DI-MISC-80678 (Consumed Weld Metal) - A Certificate of Compliance is required for all weld filler metals used for production or repair welding, and must include the following: a) Filler Metal LOT number(s) b) Specification and Type c) A positive statement that the vendor has obtained OQE and verified that each LOT of weld filler material conforms to specification requirements. d) A positive statement verifying that the weld filler metals were the correct material type or grade prior to consumption. 3.14.12 When production welds or repair welds are performed by a subcontractor,the requirement for submission of all certification documentation required herein must be passed down to the subcontractor. 3.15 Radiography (RT) - Radiography must be performed in accordance with T9074-AS-GIB-010/271. RT acceptance criteria for weldments to be per the applicabletable of S9074-AR-GIB-010A/278 (P-1 piping) or MIL-STD-2035, class 1, as applicable. 3.15.1 Submission of radiographic shooting sketches for approval is not requiredfor weldments. 3.15.2 All pieces radiographed must be permanently marked with "RT" and a unique traceability number. (Unique traceability number must be directly traceable to the RT film.) 3.15.3 See CDRL DI-MISC-80678 (Production Radiography) - Production Radiographyrequires final acceptance by the Navy. The items listed below must be submitted for final acceptance, cataloging, file, and retention. They must be submitted and approved by the Navy prior to shipment of the applicable hardware. However, when the source certification clause is invoked, they must be submitted a minimum of forty-five (45) working days prior to the date of source certification inspection. (a) Film (b) RSS/RSSS (c) RS (d) DD250 (with heat numbers corresponding to RT numbers referenced in block 16) 3.16 Quality System Requirements - The Contractor furnishing items under this contract/purchase order must provide and maintain a quality system in accordance with ISO-9001 as amplified or modified herein, with the calibration system requirements of ISO-10012 or ANSI-Z540.3 with ISO-17025. A Quality System in accordance with MIL-I-45208, with the calibration system requirements of MIL-STD-45662, is acceptable as an alternate. 3.16.1 The Contractor's quality system and products supplied under the system are subject to evaluation, verification inspection, and acceptance/nonacceptance by the Government representative to determine the system's effectiveness in meeting the quality requirements established in the Contract/Purchase Order. 3.16.2 The Contractor's quality system must be documented and must be available for review by the Contracting Officer or his representative prior to initiation of production and throughout the life of the contract. The Prime Contractor must, upon notification, make his facilities available for audit by the contracting Officer or his authorized representative. 3.16.3 See CDRL DI-QCIC-81110 (Inspection System Procedures) - All suppliers of Level I/SUBSAFE (LI/SS) material are required to submit a copy of their current documented quality system procedures to the Procurement Contracting Officer (PCO) prior to award of any contract/purchase order. Suppliers that have a copy of their current quality system procedures on file at the Procuring Activity may request the PCO waive this requirement. 3.16.4 This contract provides for the performance of Government Quality Assurance at source. The place or places of performance may not be changed without the authorization of the Procurement Contracting Officer. Upon receipt of this order, promptly notify the Government representative who normally services your plant so that appropriate planning for Government inspection can be accomplished. If you do not have an assigned Government representative, notify the nearest Defense Contract Management Agency (DCMA) Office. In the event that a local Government representative or DCMA Office cannot be located, our purchasing agent should be notified immediately. 3.16.5 Any changes made by the Contractor to a qualified quality system will require re-submittal to the PCO and concurrence by the Government Quality Assurance Representative prior to adoption. 3.17 Contractor Inspection Requirements - The Contractor must maintain adequate records of all inspections and tests. The records must indicate the nature and number of observations made, the number and type of deficiencies found, the quantities approved and rejected and the nature of corrective action taken as appropriate. Inspection records must be traceable to the material inspected. 3.17.1 The supplier's gages, measuring and test equipment must be made available for use by the Government representative when required to determine conformance with Contract requirements. When conditions warrant, the supplier's personnel must be made available for operations of such devices and for verification of their accuracy and condition. 3.17.2 All documents and reference data applicable to this contract must be available for review by the Government representative. Copies of documents required for Government inspection purposes must be furnished in accordance with the instructions provided by the Government representative. 3.18 Subcontractor Inspection Requirements - The Government has the right to inspect at source, any supplies or services that were not manufactured or performed within the contractor's facility. Such inspection can only be requested by or under authorization of the Government representative. Any purchasing documents to a subcontractor must cite the applicable portions of the contractually invoked quality system (e.g. calibration requirements), plus any product requirements that apply to the supplies being purchased. When the Government elects to perform source inspection at the subcontractor's facility, applicable purchase documents must be annotated with the following statement: "A Government inspection is required prior to shipment from your plant. Upon receipt of this order, promptly notify the Government representative who normally services your plant so that appropriate planning for Government inspection can be accomplished. If you do not have an assigned Government representative, notify the nearest Defense Contract Management Agency (DCMA) Office. In the event that a local Government representative or DCMA Office cannot be located, our purchasing agent should be notified immediately." 3.18.1 The prime contractor's program must include procedures to assess the capability of the prospective suppliers to produce the products or supply the services in accordance with the contract, prior to the issuance of any purchase document. 3.18.2 Each sub-tier supplier of material or services for items in Section 3 of this contract must be subjected to a periodic review or audit by the Prime to determine the continued capability of the supplier to control the quality of the products or services specified in the purchase order or contract. 3.18.3 The prime contractor must ensure that the purchased product conformsto specified purchase requirements and this contract. The type and extent of control applied to the supplier and the purchased product must be dependent upon the effect of the purchased product on the end item represented by this contract. 3.18.4 The prime contractor must evaluate the requirements of the contractand select suppliers based on their ability to supply the product in accordance with the prime contractor's requirements and the contract. Criteria for selection and evaluation must be established. Records of this effort must be available for review by the government. 3.18.5 The prime contractor's supplier quality assurance program must provide for a review of purchase documents to assure applicable quality requirements are included or referenced in the documentation for compliance by the supplier. 3.19 Government Furnished Material and/or Equipment (GFM/GFE) - When material or equipment is furnished by the Government, the Contractor must develop documented control procedures that require at least the following: 3.19.1 Visual examination upon receipt to detect damage during transit. 3.19.2 Inspection for completeness and proper type. 3.19.3 Verification of material quality received. 3.19.4 Periodic inspection and precautions to assure adequate storage conditions and to guard against damage from handling and deterioration during storage. 3.19.5 Functional testing, either prior to or after installation, or both, as required by the Contract to determine satisfactory operation. 3.19.6 Identification and protection from improper use or disposition. 3.19.7 Reporting to the Government, any GFM or GFE property found damaged, malfunctioning, or otherwise unsuitable for use. In the event of damage or malfunction during or after installation, the supplier must determine and record probable cause and necessity for withholding the material from use. 3.19.8 For GFE material, and as required by the terms of the bailment agreement, the supplier must establish procedures for adequate storage, maintenance, and inspection of bailed Government material. Records of all inspection and maintenance performed on bailed property must be maintained. 3.19.9 Material returned to the contractor must be handled as GFM. 3.20 Traceability and Certification Requirements - To assure that correct materials are installed in Level I/SUBSAFE systems, it is imperative that traceability be maintained from the material to the material certification test report and other required Objective Quality Evidence (OQE). The material certification report must completely and accurately reflect that the material supplied meets the specified requirements. Materials requiring Traceability and Certification Data are identified within Paragraph 3, Section C of this contract/purchase order. 3.20.1 The following provides the minimum requirements for maintaining material traceability and supplements the requirements specified in DI-MISC-81020 and elsewhere in the contract/purchase order. The Contractor must develop written procedures that implement the material control requirements stated herein and elsewhere in this Contract/Purchase Order. 3.21 Material Traceability - The certification data report must be identified through a unique traceability number, heat-lot number, or heat-treat number, as applicable, which must also be marked on the material. This traceability marking on the material must provide direct traceability to the material's chemical composition and mechanical properties certification data. For material produced by batch, continuous cast, or continuous pour processes, samples must be taken no less than once in every eight hours of operation for the purpose of validating proper chemical composition and mechanical properties. Traceability must be maintained through all process operations including any subcontracted operations, to the finished component. 3.21.1 Material Marking for Traceability and Identification - The following are the minimum marking requirements. Additional/alternate marking requirements, if applicable, will be specified elsewhere in the contract/purchase order. In addition to the marking requirements on applicable drawings and/or specifications, marking for traceability is required. All traceability markings must be permanently applied in accordance with MIL-STD-792 (except as specified below). An alternate marking method is permissible provided it is an available option in the contractually invoked specification or drawing, except in instances where the material has been modified by this contract/purchase order and differs from that specified in the specification or drawing. 3.21.2 Traceability markings for items with precision machined or plated surfaces, or material with suitable marking surface areas less than 3/8 inches square (either 3/8" x 3/8" or an area equal to 0.1406 inches square) must be applied to a durable tag and the tag securely affixed to the material. 3.21.3 Traceability markings must be maintained through assembly, and whenever possible must be visible after assembly. For items where the marking is not visible after assembly, a durable tag must be securely attached to the assembly identifying the part number, piece number, traceability number, and the location of the permanent mark. 3.21.4 Marking must be legible and must be located so as to not affect the form, fit, and function of the material. ; ; 3.22 See CDRL DI-MISC-81020 (Chemical and Mechanical) - Material Certification - In addition to the certification data requirements specified in DI-MISC-81020, the following material certification requirements apply: 3.22.1 Quantitative chemical and mechanical analysis of material traceable to traceability markings is required. Material certification test reports must include the class, form, condition, grade, type, finish, and/or composition, as applicable, of the material supplied. 3.22.2 Re-identification and re-certification of material is required when the material is subjected to a process which alters it's properties. If the starting material or raw stock is processed in a manner that will not affect its chemical composition or mechanical properties, the original certifications for the chemical composition and mechanical properties, as required by the material specification, are acceptable. Re-certification of the chemical or mechanical properties is required if a process is used during fabrication that alters the original properties of the material (e.g. alloying, heat treating, or forming). In these instances, the properties of the material must be re-determined and documented to reflect the altered condition. The altered material must be uniquely re-identified with a new traceability number. The properties thus determined and documented, are required for final certification and must conform to the material specification or the contract/purchase order requirements. When only the mechanical properties are altered, the original certification forchemical composition must be overstamped and annotated with the unique traceability material and at a minimum contain the information below. 3.22.3 Material certification data forwarded by the manufacturer must contain a signed certification that the report results represent the actual attributes of the material furnished and indicate full compliance with all applicable specification and contract requirements. Transcription of certification data is prohibited. 3.22.4 ELECTRONIC SIGNATURES. 3.22.5 Electronic signatures on Level I certification documents are considered equivalent to handwritten signatures. 3.22.6 Suppliers that use electronic signatures to authenticate company certifications and reports must ensure that process is controlled and unique to the individual signing the document. The signer must take a distinct action to electronically sign the document. 3.22.7 Suppliers must develop one method of authentication to be provided at the time of signature. The authentication method must be based on something known only to the signer (e.g., a password) or based on something only the signer possesses (e.g., a card or other device). 3.22.8 Electronic signature applications must not allow unauthorized users tochange electronically signed documents or records. All changes to electronically signed documents or records made by authorized users must be revision- or date-controlled, must identify the person making the change, and must clearly reflect that the document or record has been revised. 3.22.9 The prime contractor, as a minimum, must flow down the electronic signature requirements to their sub-tier suppliers and sub-contractors that provide electronically signed company certifications and reports to ensure that they have a procedure to control and identify unique processes for only allowing authorized individuals to sign documents. 3.22.10 Statements on material certification documents must be positive and unqualified. Disclaimers such as "to the best of our knowledge" or "we believe the information contained herein is true" are not acceptable. 3.22.11 If material is received without the required certification papers or with incorrect/missing data on the certification papers, the material will be rejected. 3.22.12 Revisions of OQE must be provided by the originating organization and must include a description of the data modified along with the proper signature requirements herein. 3.22.13 In cases of foreign certification, conversion of foreign language unitsof measure and properties measured into U.S. units of measure must be annotated on the furnished foreign certifications, if space permits, or placed on an addendum in the same format as the foreign certification data. Such conversion must be identified as to origin with name, title, and signature of the authorized representative of the company making the conversion. 3.22.14 The certification data requirements contained in this appendix must beinvoked on the prime contractor who must delegate these requirements to all sub-tier contractors supplying Level I material. 3.23 Material Handling - The written material control process must include the following: 3.23.1 All raw materials must have traceability markings (except as specified below). 3.23.2 Stored raw materials requiring traceability must be segregated to preclude intermingling with materials not requiring traceability. 3.23.3 When traceability markings will be removed by a manufacturing or fabrication process, the marking must be recorded prior to removal and be immediately restored upon completion of the process. If this cannot be done or is impractical, an appropriate material control procedure (such as a bag and tag, tagging, and/or tote box control) must be employed. The material control procedure must provide a method of positive control to preclude commingling of heats/lots or loss of traceability. The traceability marking must be reapplied upon completion of the final manufacturing process. 3.23.4 Brazing or weld filler metals for strength welds forming or integral with pressure containing components or assemblies requiring traceability must be verified to be the correct material, and type or grade, as applicable, prior to consumption. At a minimum, material verification must consist of inspection of material test reports for conformance to specified requirements. Control of welding and brazing filler metals must be maintained to the point of consumption to assure use of the correct type and grade. Markings and traceability requirements do not apply to brazing and weld filler metals after consumption. It is the responsibility of the prime contractor to ensure conformance with the above requirements on welds performed by their subcontractors. 3.23.5 Purchase orders for raw material must specify that the material be traceable to material certification test reports by traceability markings on the material and identified on the test reports. The certification data requirements contained in DI-MISC-81020 must be invoked by the prime contractor on all subcontractors supplying Level I material. 3.23.6 The material control process must include requirements for the maintenance of traceability for items sent out for subcontracted operations. If such operations would remove traceability markings, purchase or work orders must specify a method and marking location for remarking. The contractor must also ensure that subcontractor production controls are adequate to preclude commingling of materials during processing. 3.24 Receiving inspection - 3.24.1 Products and services produced by sub-tier suppliers for incorporation in the contract end item must be subject to inspection or audit at the time of receipt by the prime prior to further processing within the prime contractor's plant or shipment to another location. 3.24.2 Receiving Inspection must include as a minimum - Verification that the traceability marking on the material agrees with that on the certification test reports. Verification that certification test reports are legible and complete. Verification that the contents of the certification test reports are in compliance with the contractually invoked specifications and requirements. 3.25 Discrepancy reporting - 3.25.1 Nonconforming products from sub-tier suppliers must be identified and processed in accordance with the prime contractor's procedures for controlling nonconforming products. The prime contractor must report the receipt of any nonconforming products to the responsible sub-tier supplier in accordance with established procedures. Nonconforming material records must be maintained and available for review by the government Quality Assurance Representative (QAR). 3.26 Final Inspection - The following inspections must be performed prior to Government inspection and acceptance. 3.26.1 Material Sampling - Material must be inspected for form, fit, and function. Lot acceptance must be based on zero defects and lot rejection based on one defect. The sample size must be in accordance with the sampling plan(s) in the applicable military specification or standard, federal specification or standard, or drawing to which the material was manufactured. In the absence of such sampling plans, sampling inspection must be per ANSI/ASQ-Z1.4, general inspection level II (for sample size selection code), table IIA (for sample size). SMALL LOT SIZES - For lot sizes of fifty or less, the minimum sample size must be eight units. For lot sizes of eight or less, the sample size must be one hundred percent of the lot. 3.26.2 The Manufacturer may elect to use Statistical Process Control (SPC) to assure product quality in lieu of the above attribute sampling plan, provided that the SPC methodology/system used provides acceptable products to the Government. However, the Government/Navy Receipt Inspection Activity may perform their acceptance inspection of the material using the attribute sampling plan outlined above. 3.26.3 All data concerning material verification (chemical, mechanical or physical properties), traceability (material certifications to material marking), and nondestructive test (NDT) certifications for material must be 100% inspected. The certification test reports must also be 100% inspected for completeness and legibility. 3.26.4 All material requiring traceability must be 100% inspected for traceability marking and that the marking is legible. 3.27 See CDRL DI-MISC-80678 (Special Emphasis C of C) - The certificate of compliance must show traceability to the marking applied on each individual item, and must contain the following information: 1. Contractor's name, address and date. 2. The contract/purchase order number (for example: N00104-11-P-FA12) 3. The National Stock Number (NSN). The 18 character National Stock Number for Special Emphasis Material includes the two digit COG, the four digit FSC, the 9 digit NIIN, and the two digit SMIC (for example: 1H 4820 012345678 L1) ("N/A" when Not Applicable). 4. Lubricants, sealants, anti-seize, and/or thread locking compounds ("N/A" when Not Applicable). 5. Certification that O-rings, packing, gaskets, or other elastomeric products were installed in a compressed state within an assembly or sub-assembly, prior to expiration of the shelf life ("N/A" when Not Applicable). 6. Manufacturer's compound number ("N/A" when Not Applicable). 7. When weld procedure submittal is required by the contract, a statement that the approval date of the qualification data precedes any production or repair welding performed on this Contract. ("N/A" when Not Applicable). 8. A statement to the effect that all items furnished on this contract are in full compliance with the specifications and requirements and list each contractually invoked conformance/compliance test performed by name and that it was performed satisfactorily. 9. Contractor's or authorized personnel's signature. 4. QUALITY ASSURANCE 4.1 Notes to DCMA QAR and the Contractor - 4.1.1 DCMA QAR and the Contractor for proprietary designs - Departures from Contractor imposed requirements, not specifically covered by the contract, must be judged individually on the basis of the effect, if any, on contractual requirements. When there is a disagreement between the Contractor and the Government representative as to the effect on contractual requirements, the departure must be considered a nonconformance and be submitted to the PCO for disposition. 4.1.2 DCMA QAR and the Contractor for proprietary designs - All records of departures from Contractor imposed requirements must be maintained and available for review at the Contractor's facility. A copy must be given to the local Government representative. A record of these departures, traceable to the applicablepart number and contract number must be submitted to the PCO. 4.1.3 DCMA QAR and the Contractor for proprietary designs - For proprietary designs, the contractor's part numbers are acceptable for reference only. The delivered material must conform to all drawings, specifications, and other contractual requirements. 4.1.4 DCMA QAR - It is the responsibility of DCMA QAR to review Non-Destructive Testing (NDT) procedures for NAVSUP Contracts/Purchase Orders. 4.1.5 DCMA QAR and the Contractor - The ECDS (Electronic Contractor Data Submission) system is available for certain data submissions and to submit questions and clarifications, and waiver requests on Contracts and Solicitations. ECDS can be found at: https://register.nslc.navy.mil/ 5. PACKAGING 5.1 Preservation, Packaging, Packing and Marking - Preservation, Packaging, Packing and Marking must be in accordance with the Contract/Purchase Order Schedule and as specified below. MIL-STD 2073 PACKAGING APPLIES AS FOUND ELSEWHERE IN THE SCHEDULE 6. NOTES 6.1 Several definitions of terms that apply to CSI items are listed below. All terms may not apply to every item. 6.1.1 The ECDS (Electronic Contractor Data Submission) system is at: https://register.nslc.navy.mil/ This application will require advance registration using a PKI Digital Certificate on a CAC. A Vendor User Guide is available as CSD001 in the CSD (Contract Support Document) Library within ECDS. 6.1.2 Critical Safety Item (CSI) - Any ship part, assembly, or support equipment containing a critical characteristic whose failure, malfunction, or absence of which could cause a catastrophic or critical failure resulting in loss of, or serious damage to the ship, or unacceptable risk of personal injury or loss of life. 6.1.3 Critical Process - As determined by the TWH, any process, operation or action performed on a Ship CSI that serves to establish a critical characteristic (such as welding, soldering, machining, polishing, cleaning, or assembling) or confirm that a critical characteristic is within drawing or specification compliance (such as, testing, measurement, or non-destructive evaluation). 6.1.4 First Article - Pre-production models, initial product samples, test samples produced to ensure a manufacturer's capability to meet full specification requirements. 6.1.5 First Article Test (FAT) - Contractually required testing and inspection of a supplier's pre-production, production, or "production representative" specimens to evaluate a manufacturer's ability to produce conforming product prior to the Government's commitment to receive subsequent production items. First Article Testing is product specific and does not assess manufacturing process controls nor does it assure the effectiveness of the manufacturer's quality program. 6.1.6 Government Source Inspection (GSI) - GSI is independent oversight performed by a government representative usually a DCMA Quality Assurance Representative (QAR)) to assure that those unique product quality and system elements, identified by the Contracting Agency as important, are observed and evaluated. 6.1.7 Quality Assurance Letter of Instruction (QALI) - A QALI is a formal document initiated by a contracting activity that provides essential requirements and instructions for contracted materials to be independently verified and accepted by a government representative prior to shipment. 6.1.8 Objective Quality Evidence (OQE) - The quantitative and qualitative data of all mechanical, chemical, and performance tests performed (as required by the applicable specification, drawing, or purchase document) to prove that the material supplied conforms to the specified requirements. 6.1.9 Surface Discontinuity - Any surface irregularity, marking, or localized change in physical character of the surface, other than dimensional, that exists infrequently at one or several places. (Examples: burrs, dents, nicks, scratches, gouges, pits, center-punches, scribes, and tool marks) Surface discontinuities less than 0.005-inch in depth are acceptable provided they do not violate any other design requirements specified in this Contract/Purchase Order. 6.1.10 Traceability Code - A code or number providing traceability to the actual chemical and mechanical properties of the specified heat, batch, or form from which the material originated. 6.1.11 Verification - An examination performed to determine compliance with a specific requirement. 6.1.12 Nonconformance - A nonconformance is defined as affecting or violating the following: - The requirements of this contract/purchase order. - Contractually invoked drawings (i.e. envelope dimensions, interface dimensions with mating parts/equipment, center of gravity, weights, piece part identification, material, etc.). - Contractually invoked federal, military, or commercial specifications and/or standards. - Form, fit, function, performance to contract requirements, reliability, maintainability, interchangeability, safety of personnel or equipment, or additional cost to the Government. 6.1.13 Waiver - A written authorization to accept an item, which during manufacture, or after having been submitted for Government inspection or acceptance, is found to depart from specified requirements, but nevertheless is considered suitable for use as is or after repair by an approved method. 6.1.14 Deviation - A specific written authorization (granted prior to the manufacture of an item) to depart from a particular requirement(s) of an item's current approved configuration documentation for a specific number of units or a specified period of time, and to accept an item which is found to depart from specified requirements, but nevertheless is considered suitable for use "as is" or after repair by an approved method. 6.1.15 Critical Waiver/Deviation - This waiver/deviation consists of a departure involving safety. 6.1.16 Major Waiver/Deviation - This waiver/deviation consists of a departure involving: - Performance - Interchangeability, Reliability, Survivability, Maintainability, or Durability of the item or its repair parts - Health or Safety - Effective Use or Operation - Weight, Stability, or Structural Integrity - System design parameters as schematics, flows, pressures or temperatures - Compartment arrangements or assigned function 6.1.17 Minor Waiver/Deviation - This waiver/deviation consists of a departure which does not involve any of the factors listed as critical or major. 6.1.18 Engineering Change (EC) - A change to the current approved configuration documentation of a configuration item at any point in the life cycle of the item. 6.1.19 Engineering Change Proposal (ECP) - A proposed Engineering Change and the documentation by which the change is described, justified, and submitted to the Government for approval or disapproval. 6.1.20 Class I ECP - A class I ECP is approved by the Government's Configuration Control Board and authorized with a contract modification. 6.1.21 Class II ECP - A class II change is typically reviewed for concurrence in classification by the local government representative, unless otherwise specified elsewhere in the contract/purchase order. 6.2 In accordance with OPNAVINST 5510.1 all documents and drawings provided by the U.S. Navy to perspective Contractors must include a "Distribution Statement" to inform the contractor of the limits of distribution, and the safeguarding of the information contained on those documents and drawings. 6.2.1 There are 7 (seven) separate distribution statement codes used for non-classified documents and drawings. The definition for each is as follows: A... approved for public release; distribution is unlimited. B... distribution authorized to US Governments agencies only. C... distribution authorized to US Government agencies and their contractors. D... distribution authorized to DoD and DoD contractors only. E... distribution authorized to DoD Components only. F... further distribution only as directed by Commander, Naval Sea Systems Command, code 09T. X... distribution is authorized to US Government agencies and private individuals or enterprises eligible to obtain export controlled technical data in accordance with OPNAVINST 5510.161. 6.3 Ordering Information for Document References - The Department of Defense Single Stock Point (DODSSP), Website http://www.dsp.dla.mil/, provides product information for the Department Of Defense Index Of Specifications and Standards (DODISS) (i.e.Military/Federal Specifications and Standards), Data Item Descriptions (DIDs), and other DODSSP Products. Most Specifications can obtained directly from http://quicksearch.dla.mil/ A. Availability of Cancelled Documents - The DODSSP offers cancelled documentsthat are required by private industry in fulfillment of contractual obligationsin paper format. Documents can be requested by phoning the Subscription Services Desk. B. Commercial Specifications, Standards, and Descriptions - These specifications, standards and descriptions are not available from Government sources. Theymay be obtained from the publishers of the applicable societies. C. Ordnance Standards (OS), Weapons Specifications (WS), and NAVORD OSTD 600 Pages - These type publications may be obtained by submitting a request to: Commander, Indian Head Division, Naval Surface Warfare Center Code 8410P, 101 Strauss Avenue Indian Head, MD 20640-5035 D. On post-award actions, requests for "Official Use Only" and "NOFORN" (Not Releasable To Foreign Nationals) documents must identify the Government ContractNumber, and must be submitted via the cognizant Defense Contract Management Command (DCMC) for certification of need for the document. On pre-award actions such requests must be submitted to the PCO for certification of need for the document. E. NOFORN Military Specifications and Standards (including Amendments, Change Notices and Supplements, but NOT interim Changes) to be ordered from: Contracting Officer NAVSUP-WSS Code 87321 5450 Carlisle Pike P.O. Box 2020 Mechanicsburg, Pa. 17055-0788 F. Nuclear Reactor Publications Assigned NAVSEA Documents and Identification Numbers (i.e. NAVSEA Welding Standard, NAVSEA 250-1500-1) are to be ordered enue: Commanding Officer NAVSUP-WSS Code 009 5450 Carlisle Pike P.O. Box 2020 Mechanicsburg, Pa. 17055-0788 G. Technical Manuals Assigned NAVSEA Identification Numbers (i.e. NAVSEA Welding And Brazing Procedure, NAVSEA S9074-AQ-GIB-010/248) are to be ordered from: Commanding Officer NAVSUP-WSS Code 1 Support Branch 700 Robbins Avenue Philadelphia, Pa. 19111-5094 H. Interim Changes and Classified Specifications must be obtained by submitting a request on DD Form 1425 to NAVSUP-WSS. 6.4 Recent Updates - A short description of recent updates to the technical requirements of this item are listed below, along with an implementation date for each issue. The notes below are only a generic quick reference and are provided for convenience only, detailed requirements will be defined elsewhere in the technical sections of this Contract/Purchase Order. ;10/20/2016 - Updated ECDS URL Feb 26 2009 - Clarified testing and certs only apply to pieces listed Oct 29 2010 - Added Sampling Std for LI In-Process testing Feb 03 2011 - Clarified Intergranular Corrosion Test on raw stock Oct 22 2012 - Identified Intergranular Corrosion Test Material Classes Sep 30 2008 - Thread Inspection Requirements were clarified Dec 20 2022 - Removed requirement for vender to submit Waivers/Deviations in ECDS Jan 05 2012 - Added WAWF to forward Approved Waivers/Deviations with final OQE Dec 17 2011 - Moved Quality Assurance Text location for Readability Apr 22 2009 - Added evidence of DCMA observing test plate welding & NDT Mar 18 2008 - Identify applicable weld joints with weld procedures Aug 26 2008 - production Radiography to be approved prior to shipment Apr 15 2009 - Clarified the sample size for large and small lot sizes Jan 19 2011 - Added notification of DCMA upon contract award May 02 2009 - Added Lubricants and Sealants to the C of C Aug 27 2014 - Took out contractor's phone number requirement Dec 01 2011 - Moved "Notes to DCMA QAR" to QA Section Jan 5 2017 - ECDS/CSD info was added to Definitions in the Notes section.; DATE OF FIRST SUBMISSION=ASREQ Paragraph 10.4 of DI-QCIC-81110 does not apply. DATE OF FIRST SUBMISSION=ASREQ Block 12 - Certification data must be submitted to Portsmouth Naval Shipyard for review and acceptance prior to each shipment of material. Certification documentation must be submitted via WAWF (Wide Area Work Flow). Enter in WAWF as follows: "Ship to" N50286 "Inspect by" N39040 "Accept by" N39040 and eMail notification field: PORT_PTNH_WAWF_Notification@navy.mil No material is to be shipped prior to the receipt of Acceptance. DATE OF FIRST SUBMISSION=ASREQ Block 4 - Paragraphs 10.2.1, 10.2.2, 10.2.3, 10.3, and 10.4 of DI-MISC-80678 do not apply. Block 12 - Certification data must be submitted to Portsmouth Naval Shipyard for review and acceptance prior to each shipment of material. Certification documentation must be submitted via WAWF (Wide Area Work Flow). Enter in WAWF as follows: "Ship to" N50286 "Inspect by" N39040 "Accept by" N39040 and eMail notification field: PORT_PTNH_WAWF_Notification@navy.mil No material is to be shipped prior to the receipt of Acceptance. DATE OF FIRST SUBMISSION=ASREQ Block 4 - Paragraphs 10.2.2, 10.2.3, 10.2.4, and 10.3 of DI-MISC-80678 do not apply. Block 12 - Certification data must be submitted to Portsmouth Naval Shipyard for review and acceptance prior to each shipment of material. Certification documentation must be submitted via WAWF (Wide Area Work Flow). Enter in WAWF as follows: "Ship to" N50286 "Inspect by" N39040 "Accept by" N39040 and eMail notification field: PORT_PTNH_WAWF_Notification@navy.mil No material is to be shipped prior to the receipt of Acceptance. DATE OF FIRST SUBMISSION=ASREQ Block 12 - Within 120 Days After Contract Award, submit one copy of the welding procedure (for info) with the Qualification Data (for approval/disapproval). Approval must be obtained prior to performing any welding. This review (approval/disapproval) must be within 90 days from date of receipt. DATE OF FIRST SUBMISSION=ASREQ Block 12 - Within 120 Days After Contract Award, submit one copy of the welding procedure (for info) with the Qualification Data (for approval/disapproval). Approval must be obtained prior to performing any welding. This review (approval/disapproval) must be within 90 days from date of receipt. DATE OF FIRST SUBMISSION=ASREQ Block 4 - Paragraphs 10.2.1, 10.2.2, 10.2.3, 10.3, and 10.4 of DI-MISC-80678 do not apply. Block 12 - Certification data must be submitted to Portsmouth Naval Shipyard for review and acceptance prior to each shipment of material. Certification documentation must be submitted via WAWF (Wide Area Work Flow). Enter in WAWF as follows: "Ship to" N50286 "Inspect by" N39040 "Accept by" N39040 and eMail notification field: PORT_PTNH_WAWF_Notification@navy.mil No material is to be shipped prior to the receipt of Acceptance. DATE OF FIRST SUBMISSION=ASREQ Block 4 - Paragraphs 10.2.2, 10.2.3, 10.2.4, and 10.3 of DI-MISC-80678 do not apply. Blocks 12 and 14 - Within 135 Days After approval of Radiographic Shooting Sketches, forward one copy for review to: Commander, Portsmouth Naval Shipyard ATTN: Code 135.3 Portsmouth, NH 03804-5000 A receiving report must be entered into WAWF and should reference the date of shipment and the shipment tracking number. Enter in WAWF as follows: "Ship to" N50286 "Inspect by" N39040 "Accept by" N39040 and email notification field: PORT_PTNH_WAWF_Notification@navy.mil The review (approval/disapproval) must be accomplished within 30 days from date of receipt.

Similar Contracts

Same NAICS industry code

NAICS: 332919
New
DIBBS
SEAL, CONICAL, FLARED TU
Solicitation # SPE7M3-26-T-8152
The contract specifies the procurement of SEAL, CONICAL, FLARED TUBE FITTING, identified by part number AS4824A16 and NSN 4730-01-538-3942, to be supplied in accordance with SAE AS4824B (R2015) standards and guided by Technical Data Package Rev A Gen 2. The item is designated as a critical application component, requiring strict adherence to technical and quality requirements referenced in the DLA Master List of Technical and Quality Requirements via R or I numbers. Each package contains two units (1 PG = 2 EA), and the conical seals must remain enclosed in their protective plastic round vials during shipment to prevent crushing; removal is expressly prohibited. Packaging must comply with MIL-STD-2073-1E, including specific parameters such as QUP 001, preservative method 10, Class 1 drying, and wrapping material ZZ. Marking is required per MIL-STD-129 with the designation “1 PG (2 EA)” and no special marking code. The contract mandates origin inspection and acceptance under FAR 52.246-2 and permits Certificate of Conformance procedures per FAR 52.246-15 unless overridden by a Quality Assurance Letter of Instruction. The use of Class I ozone-depleting chemicals is strictly prohibited, and substitute chemicals require prior approval unless authorized by the specification. All deliveries must be FOB Origin with an 88-day delivery window from the need ship date of August 6, 2026, to the original required delivery date of March 12, 2027. The requirement is for 453 packages (906 units), and the full and open competition is not set aside for small businesses. The contract imposes multiple DFARS and FAR clauses governing cybersecurity, safeguarding defense information, prohibitions on hexavalent chromium and covered telecommunications equipment, whistleblower protections, and restrictions on subcontracting under FAR 52.219-14 with deviation 2021-00008. Non-domestic material requires disclosure, additive manufacturing is prohibited, and no Fast Pay applies. All quotes must be submitted via DIBBS prior to the response deadline of August 21, 2026. Payment will be processed electronically through WAWF, and the point of contact for administrative and procurement matters is
FLUID HANDLING DIVISION

POSTED

about 8 hours ago

DEADLINE

in 1 day
View Details
NAICS: 332919
New
DIBBS
CONNECTOR, HOSE
Solicitation # SPE7M0-26-T-035S
This contract is for the procurement of one unit of a connector, hose with NSN 4730-01-602-2890 and part number CUMMINS POWER GENERATION INC. 44940 P/N 502-1613, under solicitation SPE7M0-26-T-035S. Delivery is required within five days of order receipt, FOB origin, with an original required delivery date of August 7, 2026. The item must be shipped to either the parcel post address in Barstow, CA, or the freight shipping address in Yermo, CA, and transportation must be via the fastest traceable means, excluding parcel post. Packaging and marking must comply with ASTM D3951 and MIL-STD-129, with palletization governed by RP001: DLA Packaging Requirements for Procurement. The DLA Master List of Technical and Quality Requirements supersedes ASTM D3951 and incorporates all technical specifications identified by R or I numbers. Environmental restrictions strictly prohibit Class I ozone-depleting chemicals and the intentional use or direct contact of mercury or mercury-containing compounds, with limited exceptions for functional uses in batteries, fluorescent lights, instruments, sensors, controls, weapon systems, or NAVSEA-specified chemical reagents; portable fluorescent lamps and instruments containing mercury must be shockproof with a secondary containment boundary per NAVSEA 5100-003D. Hazardous materials must be labeled according to the Hazard Communication Standard unless exempted by specific federal statutes. The contractor must validate representations in the System for Award Management, including small business, HUBZone, WOSB, EDWOSB, and SDVOSB status, and comply with DFARS clauses on cybersecurity safeguards, prohibited telecommunications equipment, whistleblower rights, and the prohibition of hexavalent chromium and controlled substances. All payments must be processed electronically through the Wide Area Workflow system, and safety data sheets must be submitted prior to award. The solicitation incorporates the DLA Master Solicitation for Automated Simplified Acquisitions Revision 105, and award may be automated if no first article test is required. The Berry Amendment applies at a threshold of $150,000 and the Buy American Act applies above the micro-purchase threshold. Inspection and acceptance occur at destination under FAR 52.246-2.
MARITIME SUPPLY CHAIN ESOC BUYS

POSTED

about 8 hours ago

DEADLINE

in 1 day
View Details

More opportunities from Department Of Defense → Navsup Weapon Systems Support Mech

Same awarding agency

NAICS: 334412
New
Federal
59--CIRCUIT CARD ASSEMB, IN REPAIR/MODIFICATION OF
Solicitation # N0010426QDB44
This contract pertains to the repair and modification of a circuit card assembly under a firm-fixed-price arrangement, requiring strict adherence to technical specifications and quality standards mandated by the U.S. Navy. The solicitation mandates a Repair Turnaround Time of 53 days, measured from the physical receipt of the asset at the contractor’s facility as recorded in the Commercial Asset Visibility system, with final government inspection and acceptance essential before completion. All repairs must comply with MIL-STD-130 Rev N for marking and follow the original manufacturer’s technical directives, drawings, and approved repair procedures. The contractor is responsible for all inspections and testing, maintaining complete records for at least 365 days post-delivery, and must not substitute components without prior written approval from the contracting officer, with specific code classifications governing any design or part number changes. The contract enforces mandatory compliance with Federal Acquisition Regulation clauses including Buy American, cybersecurity maturity certification, small business subcontracting, and security prohibitions, while also requiring the use of Workflow Pro for payment and invoice processing. Freight is FOB Origin and handled by the Navy under CAV guidelines, with all quotes required to specify unit price, total price, and RTAT, or explain capacity limitations if unable to meet the 53-day requirement. The solicitation applies only to authorized distributors of the original manufacturer, and proof of authorization must be submitted with the offer. All documents and data are subject to distribution restrictions as defined by OPNAVINST 5510.1, and any requests for controlled documents must follow formal government channels. The award will be bilateral, contingent upon the contractor’s written acceptance, and pre-populated subcontract clauses define maximum RTAT, throughput capacity, and induction expiration dates not exceeding 365 days.
Bare Printed Circuit Board Manufacturing

POSTED

about 13 hours ago

DEADLINE

in 26 days
View Details
NAICS: 334412
New
Federal
ELECTRONIC COMPONEN
Solicitation # N0010426QQC15
This contract is a fixed-price solicitation issued by the Navy Supply Systems Command Weapon Systems Support in Mechanicsburg, Pennsylvania, for the repair of an electronic component identified by CAGE code 53711 and reference number 5190689. The solicitation, numbered N0010426QQC15, requires contractors to meet a strict Repair Turnaround Time (RTAT) of 730 days, measured from the physical receipt of the F-condition asset at the contractor’s facility as recorded in the Commercial Asset Visibility (CAV) system. All repairs must comply with the manufacturer’s technical specifications and drawings, and items must be marked in accordance with MIL-STD-130 Rev N. The Government requires full inspection and testing by the contractor prior to acceptance, and all inspection records must be maintained for 365 days after final delivery. Delivery terms are FOB Origin, with freight handled by the Navy under the CAV Statement of Work, and all pricing must be firm and inclusive of all repair-related costs including damage, missing parts, and handling. The contract mandates compliance with multiple regulatory clauses, including cybersecurity maturity model certification requirements, a Small Business Subcontracting Plan, and prohibitions on unauthorized substitutions under any code except Code 1, which requires immediate notification for part number-only changes. Contractors must provide detailed pricing justifications if historical pricing is exceeded or if the item has not been previously purchased by NAVSUP WSS. An option exists to increase the quantity of repairs within 365 days of contract execution. Government Source Inspection is mandatory, and contractors must be authorized distributors of the original manufacturer, submitting proof of authorization with their proposal. The contract includes provisions for testing and evaluation fees if an item is deemed beyond repair, and requires all documentation and technical data to be handled according to official distribution statements as outlined in OPNAVINST 5510.1. Proposals are due by August 20, 2026, and must include unit and total repair pricing, RTAT confirmation, and all required certifications and compliance documentation.
Bare Printed Circuit Board Manufacturing

POSTED

about 13 hours ago

DEADLINE

in 2 months
View Details
NAICS: 334412
New
Federal
SYNTHESI ER ASSY.
Solicitation # N0010426QJB73
This contract pertains to the repair of the SYNTHESI ER ASSY. under solicitation N0010426QJB73, with a required turnaround time of 80 days from physical receipt of the asset at the contractor’s facility, as recorded in the Commercial Asset Visibility system. All repairs must comply with the contractor’s approved technical standards, manufacturer specifications, and MIL-STD-130 marking requirements, with no substitutions permitted without written government approval. Inspection and testing are the contractor’s responsibility and must align with original design documentation, and the Government retains the right to conduct independent inspections. Pricing must be firm, inclusive of all costs related to repairs on potentially damaged, incomplete, or worn assets, and must reflect current market or historical pricing, with documentation required for any deviations. If the item is deemed beyond repair, a test and evaluation fee, not to exceed a specified amount, may be negotiated. The contract mandates compliance with ISO9001 quality standards, requires adherence to cybersecurity maturity certification levels, and enforces strict security prohibitions and data handling protocols per DOD directives. All documentation provided by the Navy carries distribution restrictions, and only authorized distributors of the original manufacturer may submit offers, requiring proof of authorization. Freight is FOB Origin, with the Navy handling all logistics through the Commercial Asset Visibility system, and the contractor must accurately report all receipt and transaction dates within five business days. Payment instructions follow the Wide Area Workflow system, and contract execution requires bilateral acceptance. The awardee must provide their CAGE code, facility location, and confirm whether inspection and acceptance will occur at the same or separate location. Pricing must be compared against the cost of purchasing a new unit, with current new unit price and lead time included in the quotation. Records of all inspections and repair activities must be retained for 365 days after final delivery. The solicitation explicitly excludes any deviation from the required turnaround time unless accompanied by a clear justification of capacity constraints. Contractors must verify nomenclature, part number, and NSN prior to quoting, and the response deadline is August 7, 2026. All materials must conform to applicable military and federal standards, and unauthorized distribution of government-provided technical data is prohibited.
Bare Printed Circuit Board Manufacturing

POSTED

about 13 hours ago

DEADLINE

in 2 days
View Details
NAICS: 333998
New
Federal
ATR ASSEMBLY
Solicitation # N0010425QYB30
This contract involves the repair and overhaul of the ATR Assembly (NSN 7GH 7025 016924708) for the U.S. Navy, with a monetary limit of up to $478,406.00. The work must adhere to strict military standards, including MIL-STD-1686 for electrostatic discharge control and MIL-STD-130 for marking, with repairs performed in accordance with the contractor’s approved procedures and government directives. The contractor is responsible for inspection, testing, and maintaining detailed records of all work, ensuring compliance with quality assurance requirements. The contract emphasizes the use of approved repair standards, proper packaging, and marking per MIL-STD-2073, and mandates that all modifications or substitutions in parts be approved through formal change procedures, with detailed documentation provided to the government. Key contractual clauses include the incorporation of the DFARS 252.211-7003 for item identification and valuation, and FAR 52.246-23 limiting liability. The contract is issued bilaterally, requiring written acceptance by the contractor before execution. The scope also covers the procurement of related technical manuals and specifications, with provisions for early delivery and emergency acquisition flexibilities. The contract is managed by the Naval Surface Warfare Systems Support Office in Mechanicsburg, Pennsylvania, and emphasizes compliance with Buy American and other trade agreements, along with strict documentation and distribution controls for sensitive information. The solicitation was posted on October 23, 2024, with a response deadline of November 22, 2024.
All Other Miscellaneous General Purpose Machinery Manufacturing

POSTED

about 13 hours ago

DEADLINE

in about 1 month
View Details
NAICS: 335311
New
Federal
CABLE ASSY,MAI
Solicitation # N0010426QXB46
This contract solicitation, identified as N0010426QXB46, is for the procurement of a CABLE ASSY,MAI under a Firm-Fixed Price arrangement, with all quotations required to be submitted electronically to russell.w.kreider.civ@us.navy.mil by the deadline of August 14, 2026. The award is contingent upon the vendor being an authorized distributor of the original equipment manufacturer, requiring official documentation confirming authorization, and strict adherence to Item Unique Identification (IUID) requirements per DFARS 252.211-7003 and MIL-STD-130 Rev N for physical marking. The contract specifies FOB Origin delivery, mandatory compliance with MIL-STD-2073 packaging standards, and Government Source Inspection, with all supplies subject to inspection and acceptance in accordance with the terms outlined. The contractor must provide a detailed cost breakdown including unit price, total price, lead time, CAGE codes for award and inspection, and a quotation expiration date valid for at least 90 days, and must not make any design, material, or part number changes without prior written approval from the contracting officer, using designated change codes to categorize modifications. The contract imposes comprehensive quality assurance obligations, requiring the contractor to maintain complete and accessible inspection records for 365 days after final delivery and to ensure full compliance with all technical specifications without reliance on sampling to justify defective material submission. Alterations to the part must be flagged using specific design change codes ranging from simple part number updates to non-interchangeable redesigns, with supporting drawings and explanations required for evaluation. All referenced documents must be obtained through authorized DoD sources, with special procedures outlined for restricted documents such as NOFORN or classified materials, which require formal request processes. The solicitation emphasizes that only authorized distributors will be considered for award, and failure to submit proof of authorization disqualifies the offer. The contracting office is located in Mechanicsburg, Pennsylvania, under the Naval Supply Systems Command Weapon Systems Support, with all communications and submissions directed to the designated point of contact.
Power, Distribution, and Specialty Transformer Manufacturing

POSTED

about 13 hours ago

DEADLINE

in about 2 months
View Details
NAICS: 334412
New
Federal
CIRCUIT CARD ASSEMB
Solicitation # N0010426QQB83
This contract pertains to the repair of CIRCUIT CARD ASSEMBLY items under an emergency acquisition authority, issued as a solicitation with the number N0010426QQB83 by the Naval Supply Systems Command Weapon Systems Support in Mechanicsburg, Pennsylvania. The requirement mandates that all repairs adhere strictly to the original manufacturer’s technical specifications, drawings, and approved procedures, with compliance governed by MIL-STD-130 for marking and ANSI/ESD S20.20 for electrostatic discharge control. All work must be performed by authorized distributors of the original equipment manufacturer, who must submit proof of authorization with their quote. The contract requires a Firm-Fixed-Price structure, with the contractor responsible for inspection, testing, and documentation throughout the repair process, and all repairs must meet a designated Return to Repair Turnaround Time (RTAT) measured from physical receipt of the asset at the contractor’s facility as recorded in the Commercial Asset Visibility system. The contract stipulates that freight is FOB Origin and handled by the Navy under the Commercial Asset Visibility Statement of Work, with Government Source Inspection mandatory. Contractors must provide detailed pricing including unit and total costs, RTAT, and justification for any pricing outside historical norms, along with comparisons between repair costs and new purchase prices. If an item is deemed beyond repair, a separate testing and evaluation fee applies, capped at a specified amount. Modifications to part numbers, materials, or design require prior written approval from the contracting officer, classified under specific change codes. All records must be maintained for 365 days post-delivery. The order is issued under and incorporates by reference any existing Basic Ordering Agreement, with BOA terms prevailing in case of conflict. The contract also enforces Buy American requirements, security prohibitions, small business subcontracting obligations, and mandatory use of Workflow Pro for payment and documentation, with all submissions due by August 28, 2026.
Bare Printed Circuit Board Manufacturing

POSTED

about 13 hours ago

DEADLINE

in about 1 month
View Details
NAICS: 334412
New
Federal
GENERATOR,SIGNAL
Solicitation # N0010426QQB95
This contract, issued under Emergency Acquisition Authority, seeks repair services for the GENERATOR,SIGNAL under solicitation N0010426QQB95, with a response deadline of August 28, 2026. The award will be made bilaterally, requiring the contractor’s signed acceptance, and all repairs must meet strict technical standards outlined in the manufacturer’s specifications and applicable military standards including MIL-STD-130 Rev N for marking and MIL-STD-2073 for packaging. The contractor is required to provide a Firm-Fixed-Price quote with a guaranteed Repair Turnaround Time (RTAT) measured from the physical receipt of the asset at their facility as recorded in the Commercial Asset Visibility system, with final inspection and acceptance by the Government mandatory within that timeframe. The contract mandates Government Source Inspection, and all repairs must be performed using approved technical documentation and procedures, with no substitutions permitted without prior written approval. Pricing must be justified, especially if not previously purchased by NAVSUP WSS or if it exceeds historical rates, with required documentation such as redacted invoices or comparisons to the cost of new units. The contract imposes rigorous compliance obligations including adherence to cybersecurity maturity model certification requirements, a Small Business Subcontracting Plan, and security prohibitions under recent deviation directives. Contractors must validate their status as authorized distributors of the original manufacturer’s item with official documentation. All records related to inspection and testing must be retained for 365 days after final delivery, and failure to meet RTAT or inspection standards could result in non-acceptance. Freight is FOB Origin, handled by the Navy under the Commercial Asset Visibility Statement of Work, and payment will follow the Wide Area Workflow system. Key performance and administrative contacts are centralized through Justin T. Long at NAVSUP WSS, and all document references must be sourced from approved government portals or authorized channels with due attention to distribution statements and NOFORN restrictions. The contract is tied to a Basic Ordering Agreement whose terms supersede any conflicting provisions in this solicitation, and the sole CAGE code associated is 53711.
Bare Printed Circuit Board Manufacturing

POSTED

about 13 hours ago

DEADLINE

in about 1 month
View Details
NAICS: 334412
New
Federal
59--ELECTRONIC COMPONEN
Solicitation # N0010425RQA04
This contract pertains to the procurement of electronic components under a firm fixed-price arrangement, with requirements centered on manufacturing and adherence to specified quality standards. The contractor must comply with ISO 9001 quality system requirements and ensure all items meet MIL-STD-129 marking standards and other referenced military specifications. Delivery must conform to the contract’s technical specifications, with cage codes 53711 and 5943065 identifying the authorized design, and any changes to design, material, or part number subject to prior written approval through a formal change order system with designated code classifications. The contractor bears full responsibility for inspection and quality assurance, maintaining records for four years after final delivery, and is prohibited from submitting known defective materials regardless of sampling protocols. The solicitation, issued by the Naval Supply Systems Command Weapon Systems Support in Mechanicsburg, Pennsylvania, under solicitation number N0010425RQA04, has a response deadline of July 22, 2026, and is restricted to authorized distributors of the original manufacturer, requiring proof of authorization with official company letterhead. Proposals must be submitted via NECO or email to the designated point of contact, and all documentation must include proper distribution statements per OPNAVINST 5510.1. The contract incorporates multiple clauses related to Buy American Act compliance, equal opportunity, veterans’ employment, small business subcontracting, and cost accounting standards, with specific instructions for payment and transport, including the use of Wide Area Workflow for invoicing. The NAICS code 334412 reflects the nature of the procurement as being within electronic component manufacturing, and the contract prohibits unauthorized retransmission of government-provided technical data without proper classification handling and distribution controls.
Bare Printed Circuit Board Manufacturing

POSTED

about 13 hours ago

DEADLINE

in 19 days
View Details
NAICS: 335312
New
Federal
61--MOTOR ASSY TLTH, IN REPAIR/MODIFICATION OF
Solicitation # N0010426RZB35
This contract is a sole-source Firm Fixed Price solicitation under the Advanced Equipment Repair Program for the repair and modification of the MOTOR ASSY TLTH, with a contractual delivery requirement of 365 days from physical receipt of the asset at the contractor’s facility, as recorded in the Commercial Asset Visibility system. All repairs must adhere to CAGE 11384 drawing 970952 and the SUBMEPP Repair Instruction 5952-012-0002 Rev - CHG 1 (CSD727), with any replacement parts compliant with the approved Technical Data Package. Proposals must include detailed teardown and evaluation rates, throughput constraints, induction expiration dates, and total costs covering all aspects of repair including damaged, incomplete, or worn units, as well as CAV reporting obligations. Failure to meet the 365-day turnaround time will result in per-unit price reductions, without limiting the Government’s right to terminate for default. The contractor must be authorized by the Original Equipment Manufacturer if not the OEM itself, and must provide signed authorization on official letterhead. Packaging, preservation, and marking must follow MIL-STD 2073 and other referenced specifications, and all certification documentation must be submitted through Wide Area WorkFlow. The contract is rated under the Defense Priorities and Allocations System and includes mandatory clauses for security, small business subcontracting, Buy American, integrity of unit prices, cost accounting standards, and limitations on pass-through charges, among others. The Government considers contractual documents issued upon electronic transmittal, and final acceptance requires Government inspection within the contracted timeline. Proposals are due by July 6, 2026, and all supporting data, including Contract Support Documents from ECDS, must be obtained and submitted as required.
Motor and Generator Manufacturing

POSTED

about 13 hours ago

DEADLINE

in 2 days
View Details
NAICS: 334413
New
Federal
MODULE PROCESSOR
Solicitation # N0010426QQB97
This contract solicitation, issued under solicitation number N0010426QQB97 by the Naval Supply Systems Command Weapon Systems Support in Mechanicsburg, Pennsylvania, seeks repair services for the MODULE PROCESSOR under a firm-fixed-price arrangement. The primary requirement is a Repair Turnaround Time (RTAT) of 77 days, measured from the physical receipt of the asset at the contractor’s facility as recorded in the Commercial Asset Visibility (CAV) system. All pricing must be firm and include full costs associated with repairing items in any condition—whether damaged, incomplete, missing hardware, or worn. The Government requires strict compliance with MIL-STD-130 Rev N for marking and mandates adherence to manufacturer specifications, technical orders, and approved repair procedures. Inspections are mandatory and conducted by Government Source Inspection, and contractors must maintain complete records of all inspection activities for 365 days after final delivery. Freight is FOB Origin and handled by the Navy per the CAV Statement of Work. The contract enforces stringent security, compliance, and reporting protocols including cybersecurity maturity certification, Buy American requirements, and a Small Business Subcontracting Plan. Contractors must confirm their CAGE codes, inspection locations, and facility details, and provide pricing comparisons to new unit costs. Any failure to meet the RTAT will result in a monthly price reduction per unit, capped at a specified amount, without prejudice to the Government’s right to terminate for default. The use of the Workflow Pro (WFP) Mod Assist Module is mandatory, and offerors must prove they are authorized distributors of the original manufacturer. Amendments to the solicitation removed certain clauses and deprecated language, while reinforcing that all pricing must reflect full repair scope, including evaluation costs for items deemed Beyond Economic Repair (BER), where a negotiated NTE fee may apply. Responses must be submitted by August 7, 2026, with all documentation, including proof of authorization and historical pricing data where applicable, to be included with the quote.
Semiconductor and Related Device Manufacturing

POSTED

about 13 hours ago

DEADLINE

in 30 days
View Details
NAICS: 334419
New
Federal
SERVO,ELEVATION
Solicitation # N0010426QQB75
This contract solicitation, issued by the Naval Supply Systems Command Weapon Systems Support in Mechanicsburg, Pennsylvania, seeks repair services for the SERVO,ELEVATION component under solicitation number N0010426QQB75. The repair must meet a stringent turnaround time of 730 days, measured from the physical receipt of the asset at the contractor’s facility as recorded in the Commercial Asset Visibility system, with final government inspection and acceptance required within that timeframe. All repairs must adhere strictly to MIL-STD-130 marking requirements and configuration control standards under MIL-STD-973, with any design, material, or part number changes requiring prior written approval from the contracting officer. The contract mandates firm-fixed-price pricing, with no negotiated adjustments unless an item is determined beyond repair, in which case a limited test-and-evaluation fee may be negotiated not to exceed a specified amount. The contractor is responsible for all inspection, testing, and quality assurance in accordance with original manufacturer specifications and government oversight, and must maintain inspection records for one year after final delivery. Freight is FOB Origin, and the Navy manages all logistics through the Commercial Asset Visibility system. Contractors must be authorized distributors of the original manufacturer, and proof of authorization must accompany their submission. A small business subcontracting plan is required, and compliance with Buy American and cybersecurity maturity model certification standards is mandatory. The contract includes strict prohibitions on unexcused delays, with monthly price reductions applied for each day the RTAT is missed, capped at a predetermined maximum, and subject to termination for default if delays persist. Pricing must justify any deviation from historical rates, and for new or upgraded items, the contractor must provide comparable NSNs or commercial invoices. All submitted documentation must include the awardee’s CAGE code, inspection and performance locations, and a comparison of the repair cost against the new unit price and lead time. The response deadline is August 20, 2026, and government source inspection is non-negotiable, with all items subject to final acceptance under the contract's rigorous technical and compliance standards.
Other Electronic Component Manufacturing

POSTED

about 13 hours ago

DEADLINE

in about 1 month
View Details