This Combined Synopsis/Solicitation opportunity from Department Of Defense was posted on August 12, 2026. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

DTA ISB Sprung Shelter Repairs 2026

Closed
W912D026QA010Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 332311
New
Federal
Solicitation_S-280C/G Vehicle Mounted Shelter
Solicitation # W912CH-26-R-A096
The Army Contracting Command - Detroit Arsenal is soliciting proposals for a five-year, Firm-Fixed-Price, Indefinite Delivery/Indefinite Quantity contract for the manufacture and delivery of four variants of the S-280C/G Vehicle Mounted Shelter. These lightweight tactical shelters, available in shielded and unshielded versions with or without mobilizer adapter kits, are designed to protect personnel and sensitive electronic equipment from demanding field environments and electromagnetic interference. The contract has a minimum guaranteed value of $100,000 and a maximum ceiling of $4,000,000. This is a 100% Small Business Set-Aside under NAICS 332311, with award based on a best-value tradeoff between technical factors, specifically EMI shielding design and manufacturing processes, and price. The scope of work includes First Article Testing, full-scale production, and the delivery of associated technical and logistics data, including operator manuals and provisioning parts lists. Manufacturing must strictly adhere to the Government-owned Technical Data Package and ASTM E1975-22 standards. Due to the export-controlled nature of the technical data, offerors must have a valid DD Form 2345 on file. Deliveries are FOB Destination, with an estimated distribution of 75 percent to CONUS locations, such as the Sierra Army Depot, and 25 percent to OCONUS locations including Germany, Korea, or Japan. Proposals must be submitted electronically by October 30, 2026.
W6QK Acc- Dta

POSTED

about 7 hours ago

DEADLINE

in 10 days

AI Contract Overview

Show more

Solicitation W912D0-26-Q-A010 is a Request for Quote to establish a Firm Fixed Price requirements service contract for labor and equipment to perform warranty repairs on Sprung Structures at Fort Wainwright, Alaska. This is a 100 percent Small Business Set-aside under NAICS code 332311. The project focuses on three 60 by 120 foot structures located at the Donnelly Training Area ISB, requiring a Preferred Contractor with specific experience in Sprung products to work under the direction of a company technical representative. The scope of work includes inspecting and repairing membranes, insulation, and ceiling retaining systems, as well as servicing fuel-fired furnaces, fuel tanks, and OEM overhead rolling service doors. Additionally, the contractor must address electrical wiring safety, repair a non-operational electrical system in one specific shelter, and perform sub-surface burial of primary electrical conduit. All repairs must adhere to OEM manufacturer standards and be completed no later than October 31, 2026.

General Info

Small business contract for warranty repairs on Sprung Structures at Fort Wainwright, Alaska.

NAICS

332311 - Prefabricated Metal Building and Component Manufacturing

Place of Performance

Fort Wainwright, AK, 99703, USA

Set-Aside

SBA

Documents

4

DTA ISB Sprung Shelter Repair Scope of Work 20260528

PDF, High priority: read this firstsow
High

RFQ W912D0-26-Q-A010 Repair Sprung Shelter Warranty Repairs

PDF, High priority: read this firstrfq
High

Solicitation W912D026QA010 for DTA Sprung Shelter Repair

PDF, High priority: read this firstrfq
High

Wage Determination No. 2015-5683 Revision 27 for Alaska

PDF, High priority: read this firstwage-determination
High

AI Contract Breakdown

Uniform Contract Format

Sign up to view the full breakdown with detailed analysis of each section.

Timeline

PhaseClosed
Posted

Combined Synopsis

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Start your free trial to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Defense → 0413 Aq Hq Rco-Ak Wainwrig
Contacts2 people available
OfficeFORT WAINWRIGHT, AK, 99703-0510, USA
Office AddressFORT WAINWRIGHT, AK, 99703-0510, USA

Full Description

Show more

This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in the Federal Acquisition Regulation (FAR) Subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; quotes are being requested.
The combined synopsis/solicitation number is W912D0-26-Q-A010 and is issued as a Request for Quote (RFQ) to establish a Firm Fixed Price (FFP) requirements type Service contract for the Labor and Equipment for Warranty Repairs to Fort Wainwright Sprung Structures.
The combined synopsis/solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular (FAC) 2026-01, effective 13 April 2026. The DFARS provisions and clauses are those in effect 7 May 2026.
This requirement is solicited on a 100% Small Business Set-aside basis in accordance with FAR 19.5.
The associated North American Industrial Classification System (NAICS) code for this procurement is 332311 Prefabricated Metal Building and Component Manufacturing The small business size standard is $8,000,000.00.
DESCRIPTION OF REQUIREMENT:
This is a non-personnel services contract to provide manpower and equipment to conduct warranty repairs to existing Sprung Structures on Fort Wainwright, AK. The Government shall not exercise any supervision or control over the contract service providers performing the services herein. Such contract service providers shall be accountable solely to the Contractor who, in turn is responsible to the Government.
In 2019 Army Material Command (AMC) erected 10 Sprung Shelters on Fort Wainwright in support of Army Quality of Life efforts to improve soldier living and working conditions at Fort Wainwright. AMC erected eight (8) warm maintenance facility shelters (WINMATs) and two (2) combat readiness training facility shelters (CRTF). AMC used its LOGCAP program to build the shelters. The LOGCAP program included one year of preventative maintenance and repairs after completion of the last shelter. The LOGCAP coverage has ended. The Sprung shelters are considered ‘re-locatable’ structures, not real property. The Fort Wainwright Directorate of Public Works (DPW) is not able to provide maintenance support to re-locatable structures due to IMCOM regulations.
The Three (3) of the Sprung structures require repairs to the membrane and insulation to ensure proper operation and function, as well as to preserve the service life of the shelters.
The Sprung Structures have a warranty that covers materials and a company technical representative. This contract is to provide manpower and equipment to conduct repairs
Page 2 of 37
under the direction of the technical representative. The contractor should be a Sprung Structures ‘Preferred Contractor’ with experience working on Sprung products.
The contractor shall provide all personnel, equipment, supervision, and non-personal services requested in this statement necessary to support this Performance Work Statement. The contractor shall perform to the standards in this contract.
2.0 OBJECTIVES
2.1 Provide Inspection, Preventative Maintenance and Repairs to the three existing 60’ X 120’ Sprung Structures located at Donnelly Training Area ISB in the vicinity of Fort Greely, AK. Assess current membranes, insulation, access doors and mechanical components and provide materials and expertise necessary to repair structure NLT 31 October 2026. Repairs shall be made in accordance with OEM manufacturer standards and with approved OEM materials.
2.2 Provide preventative maintenance, servicing and, if required, repairs of fuel-fired furnaces (2 per structure), fuel tanks (2 per structure) and associated plumbing as noted in the attached drawing. Repairs shall be made in accordance with OEM manufacturer standards and with approved OEM parts and materials. Technician repair will be required to facilitate full operations of the furnaces. Coordinate both service and repair of these furnaces.
2.3 Provide preventative maintenance, servicing and, if required, repairs of OEM Overhead Door rolling service doors (2 each, 14’ X 14’ rolling service doors per shelter). If repair is required to facilitate full operations of these doors, Technician will repair i/a/w OEM repair manuals.
2.4 Provide service of electrical wiring and components on interior of the shelters as noted in the attached drawing to ensure safety and standardized code compliance. If repairs are required, they must be completed i/a/w common safety standards and, if applicable, i/a/w shelter OEM requirements.
2.5 Provide repairs to the electrical system and/or connections to Sprung #2 (see map). The electrical system in Sprung #2 is not operational and shows signs of shorting out/arcing when power is turned on.
2.6 Perform repairs and re-installation of ceiling insulation retaining system. Some of the retaining bars that hold up the insulation have become loose and dislodged from the shelter structure.
2.7 Perform sub-surface burial of primary electrical conduit which runs from power pole to main distribution panel i/a/w common industry standards.
2.8 Photos and inclusions provided with this Statement of Work (Map, Drawings) allow contractor to gauge repair requirements. On site or virtual site visits can/should be coordinated with the contracting office and installation support staff to better gauge the requirement. Tele-conferencing can be coordinated with the installation to allow a virtual walk through and discussion of repair requirements. See information enclosure provided for details.
2.9 Contractor must coordinate Post Access requirements prior to site tour and Contract Startup

More opportunities from Department Of Defense → 0413 Aq Hq Rco-Ak Wainwrig

Same awarding agency

NAICS: 541611
New
Federal
11th ABN DIV Historian and Coordination Support
Solicitation # W912D027QA002
Solicitation W912D0-27-Q-A002 is a request for quotations for non-personal historian and coordination support services for the 11th Airborne Division at Joint Base Elmendorf-Richardson, Alaska. This acquisition is a 100 percent set-aside for small businesses, specifically targeting Women-Owned Small Businesses, under NAICS code 541611. The contract is structured as a firm-fixed-price award consisting of a base period from November 2, 2026, to November 1, 2027, with one option year extending to November 1, 2028. The selected contractor will provide 0.5 full-time equivalent personnel to serve as the Command Historian, responsible for collecting and archiving historical materials, advising the Division Command Group, and supporting the Commander’s Initiative Group for VIP and Congressional visits. Key deliverables include the creation of a digital catalogue of artifacts within 90 days, the establishment of artifact displays within 180 days, and the production of an annual Unit History Report. The contractor must ensure personnel can obtain a Secret security clearance within 60 days of implementation and comply with strict DoD cybersecurity and records management policies. Award will be based on the best value to the government, with evaluation factors weighted in order of importance as technical capability, past performance, and price. Complete quotes, including a technical narrative limited to 10 pages and three past performance examples, must be submitted by 1000 AKDT on October 23, 2026.
Administrative Management and General Management Consulting Services

POSTED

1 day ago

DEADLINE

in 3 days
View Details
NAICS: 221310
New
Federal
Chlorination Systems and Maintenance - FWA
Solicitation # W912D027QA001
Solicitation W912D027QA001 is a total small business set-aside for a firm-fixed-price service contract to provide chlorination system maintenance and potable water tank inspections at Fort Wainwright, Alaska. The contractor is responsible for performing monthly maintenance on chlorination monitoring and injection systems and conducting quarterly inspections of water storage tanks in Buildings 1169, 1185, 2400, and 5108. Key requirements include adhering to TB MD 576 4-2 for tank cleaning, submitting electronic summary reports by the fifth business day of every third month, and responding to emergency call-outs to restore system functionality within two business days. The contract structure consists of a base period from November 16, 2026, to November 15, 2027, with four subsequent one-year options and a possible six-month extension, for a total maximum duration of 60 months. Award will be made to the responsible offeror whose proposal is most advantageous to the government based on technical merit, past performance, and price. Technical evaluations focus on certifications and equipment lists, while past performance is verified through systems like CPARS and PPIRS. All invoices must be processed through Wide Area Workflow. Contractors must comply with strict safety protocols, including coordination with the Installation Safety Office for confined space entry and lockout/tag-out procedures, and must adhere to the Service Contract Act wage determinations for the Fairbanks North Star area. Proposals must be submitted via email to the designated contracting officers by October 22, 2026.
Water Supply and Irrigation Systems

POSTED

1 day ago

DEADLINE

in 2 days
View Details
NAICS: 541620
Federal
Environmental and Safety Compliance SupportThe contract is for environmental and safety compliance support at Fort Wainwright, Alaska, involving a comprehensive suite of services to ensure regulatory adherence during construction activities. Key responsibilities include conducting environmental site assessments to identify potential contamination or ecological impacts, developing and implementing a stormwater pollution prevention plan to mitigate runoff-related hazards, and providing continuous safety monitoring to protect personnel, infrastructure, and the surrounding environment. These services are required to align with federal and military environmental regulations, with a focus on preventing pollutants from entering waterways and maintaining a safe worksite throughout the construction lifecycle. This is a total small business set-aside under NAICS code 541620, which categorizes the work as environmental consulting services, and is structured as a subcontract under the Department of Defense. The work is tied to a military installation, requiring strict coordination with defense protocols and environmental stewardship standards. Performance is localized entirely at Fort Wainwright, with all deliverables subject to the installation’s operational and regulatory requirements. The solicitation, posted in May 2026, emphasizes the government’s intent to award the contract solely to a qualified small business, ensuring support for small business growth within the environmental compliance sector.
Environmental Consulting Services

POSTED

5 months ago

DEADLINE

N/A
View Details

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS