Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, November 11 at 2:00 PM ET

Register Free →

This Government Contract opportunity from Department Of Defense was posted on September 12, 2007. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

E--Annoucement of Award

Awarded
W912DQ-07-T-0122Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 238120
New
International
Provision of Structural Repairs and Planned Maintenance to Blackpool Tower Winter 2026/7 and Summer 2027
Solicitation # ocds-h6vhtk-078f6c
Blackpool Borough Council is seeking a qualified Remedial Works Supplier to provide structural repairs and planned maintenance for Blackpool Tower, with an estimated total value of 4,000,000 GBP including VAT. The project is divided into three phases: a Winter Works package from November 2026 to March 2027 during operational closure, a Summer Works package from April 2027 to November 2027 during the operating season, and ongoing ad-hoc maintenance beyond November 2027 based on annual surveys. The initial period of performance runs from November 30, 2026, to November 29, 2027, with a possible one-year extension to November 29, 2028. The contract is an open competition with award criteria weighted at 50 percent Quality, 40 percent Price, and 10 percent Social Value. Mandatory requirements include IRATA level 3 qualified supervisors, IRATA level 1 or 2 technicians, and project managers who are Chartered Members of the Institution of Civil Engineers or Institution of Structural Engineers. Suppliers must maintain insurance coverage of 10 million GBP for Employer's Liability and Public Liability, and 5 million GBP for Professional Indemnity. All work must adhere to strict technical and safety standards, including BS EN 1090 Execution Class 3 for steel structures, CDM 2015, and the Work at Height Regulations 2005. The deadline for tender submissions is November 20, 2026.
Blackpool Borough Council

POSTED

about 23 hours ago

DEADLINE

in 22 days
NAICS: 238120
New
SLED
Corpyard Phase II Connex Structural Anchoring & Welding: (Rebid)
Solicitation # 26-091-ITB
The City of West Sacramento is soliciting bids for the Corpyard Phase II project to structurally anchor 14 existing shipping containers at 4300 West Capitol Avenue. The scope of work requires a licensed contractor to provide all labor, materials, and specialized tooling to secure the containers to a cement-treated asphalt surface. Key technical requirements include drilling and hole cleaning, the installation of Bolthold asphalt substrate, securing ASTMA36 plates with epoxied steel rods, and performing AWS welding to the container framing. To prevent corrosion, all welded and anchored areas must receive a zinc-rich cold galvanizing rust-inhibiting coating. The project must be executed according to PSE stamped drawings and structural calculations, with final acceptance contingent upon inspection by the City's Building department and the project engineer. This solicitation, identified as ITB 26-091, has an estimated project value of 35,000 dollars. Bids must be submitted electronically via the OpenGov portal by November 10, 2026, with the contract award scheduled for December 2, 2026. The contract will be awarded to the lowest responsive and responsible bidder. Mandatory requirements include compliance with California prevailing wage laws, registration with the California State Department of Industrial Relations, and the provision of a 10 percent bid security. The successful contractor must also provide performance and payment bonds equal to 100 percent of the contract price and maintain comprehensive insurance coverage, including XCU hazards and general liability, naming the City as an additional insured.
Capital Projects - Construction

POSTED

1 day ago

DEADLINE

in 12 days

AI Contract Overview

Show more

This contract is a solicitation for a small business to provide a pre-fabricated, reinforced concrete restroom and shower building for the U.S. Army Corps of Engineers at the Pomona Lake Project near Vassar, Kansas. The required structure must feature four individual ADA-compliant compartments, each equipped with a shower, flush toilet, and sink. Key technical specifications include a minimum wind load of 120 MPH, 5000 psi reinforced concrete for walls, floors, and roofs, and vandal-resistant components. The contractor is responsible for all labor, materials, equipment, and transportation, including crane services for installation and the potential construction of foundations and utility hookups. Bidders must submit descriptive literature verifying their ability to meet all construction standards, plumbing and electrical requirements, and the provision of various exterior and interior finish options. The government will provide a level site, while the contractor must provide a minimum one-year warranty on the building and all components. This procurement is a 100 percent small business set-aside under NAICS code 238120, requiring active CCR registration and electronic representations and certifications for eligibility.

General Info

Contract Value

$92,817

NAICS

238120 - Structural Steel and Precast Concrete Contractors

Place of Performance

MO, USA

Set-Aside

NONE

Award Issued Date

Documents

0

No documents available

Documents will appear here when they are available.

AI Contract Breakdown

Uniform Contract Format

No documents to break down

The breakdown needs solicitation documents. None were found from this contract's source.

Timeline

PhaseAwarded
Posted

Combined Synopsis

Awarded

Contract was awarded

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Defense → W071 Endist Kansas City
ContactsNo contacts available
OfficeKANSAS CITY, MO, 64106-2896, USA
Office AddressKANSAS CITY, MO, 64106-2896, USA
ContactsNo contact information available

Full Description

Show more
This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in Subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; proposals are being requested and a written solicitation will not be issued. BID SCHEDULE LINE ITEMS: 0001: $___________________ The contractor shall provide all labor, materials, equipment, transportation, supervision and other items and services necessary to provide pre-fabricated concrete restroom structure to the U.S. Army Corp s of Engineers, Pomona Lake Project near Vassar, Kansas DESCRIPTIVE LITERATURE The Contractor shall submit descriptive literature with their bid to verify that the company can provide the types of buildings, quality of buildings, building features, and building options required in the scope of work. The descriptive literature shall also include information on the installation services provided by the company as indicated in the scope of work. Specifically the descriptive literature shall verify the following: 1. Details on Structure type and quality of construction that will verify the structure meets the specifications - See specification for requirements. 2. Verification that building is pre-fabricated - no additional assembly required other than placing on pad by the contractor and putting preassembled sections together by contractor. 3. Verification that contractor can supply all required building types and sizes - see specification. 4. Verification all building code standards in the specification can be met. 5. Verification that contractor can provide requested installation services. 6. Verification that all plumbing and electrical requirements in specifications will be met. 7. Verification that all requested optional items can be provided including types of finishes for walls and roof, vault toilet options, skylights, door locks, toilet paper dispensers, hot water heaters, etc. - See specification for details. 8. Verification that a variety of color options for the walls and roof will be available for selection after award. BUILDING DETAILS Pre-Fabricated Restroom/Shower Buildings  Pomona Project Below are general requirements for the building at Pomona Lake. 1.) Four Individual Compartments - Each with ADA Shower, Flush Toilet, and Sink, - CXT, Inc. Navajo Model, or Approved Equal: Flush toilet/Shower Building: Structure should have an approximate overall dimension of 26 W x 20 L x 12 H. A two (2) tone co lor scheme of Natural Honey exterior roof and Nuss Brown barn wood texture exterior walls. Interior walls and ceilings will be painted white. This building shall be pre-plumbed and pre-wired for interior and exterior lighting and LP tank less water heate r. Four (4) individual rooms providing family assist style accommodations will consist of shower, toilet, sink, mirror, toilet paper dispenser, hand dryer, exhaust fan, motion sensor for ceiling light and a minimum of one window and one standard skylight p er room. Access will be provided for each room via a single entry door located on each ends of the building. All facilities will meet or exceed ADA requirements including, but not limited to toilet, sink, stainless steel wall mounted handrails, shower ar ea. A handicapped accessible platform seat must be located in one corner of the shower area nearest the water control valves and showerhead. Stainless steel wall-mounted handrails should be located near the platform seat. Shower floor will be finished o r of material providing a non-slick surface material. Center floor drain will be provided for each room with sufficient slope to provide drainage of water. SPECIFICATION FOR PRE-FABRICATED BUILDINGS 1. GENERAL. This contract is for 1 building. The government will provide a level site for the buildings. All buildings shall be the same basic type  solid, reinforced conc rete, pre-fabricated, pre-engineered buildings. The buildings will not all be the same size or the have all of the same exact features. All shall meet the following criteria: Structure - Reinforced Concrete Prefabricated/Pre-assembled Concrete Buildings Types - Vault toilets, Flush Restrooms or Flush Restroom/Shower Structures both single and multiple compartments Building Code Standards  minimum wind load of 120 MPH wind load, 240 psf snow load, and seismic zone 4. Walls - minimum of 4 thick, 5000 psi, and reinforced concrete - must be connected by welded plates at each joint. Roof and floors - minimum of 5 thick, 5000 psi, reinforced concrete Building shall be equivalent to the quality and construction type to the CXT Company (+1 (555) 000-0000) or approved equal Building installation - building shall be designed to be offloaded by a mobile crane with quick installation and hookup at the job site (one day or less) Building and components shall be vandal resistant The contract shall include all deliver costs and crane costs, and cost to set the building on the foundation. If required by the bid schedule, contract must include the following: Foundation construction (hole for vaults and gravel pads for flush buildings). Stubbing up all utilities (water, sewage, and electrical) from 1 foot outside building into building footprint utility chase. Final connection of utilities inside building after it is placed on the foundation. Contractor shall provide two sets of engineered stamped drawings for each building. 2. GOVERNMENT RESPONSIBILITIES. The government shall provide a level site that is identified by stakes. The site shall be clear, level, and free of overhead and/or underground obstructions. The government shall also provide access to the site for truck delivery and sufficient area for the crane to install and the equipment to perform the contract requirements. 3. WARRANTY. A minimum warranty of one year shall be provided on the building and all components. The contractor must agree to repair or replace any damage that is not due to misuse, negligence, acts of God, or accidents, or due to improper maintenance b y the user or due to the building being used outside the specifications for which such goods were designed. 4. MATERIALS. All buildings shall also have the following standard features unless otherwise specified. a. Concrete. Concrete mix design will be designed to ACI 211.1. Concrete will contain a minimum of 610 pounds of cement per cubic yard and will be a low alkali type III conforming to ASTM C-150. Coarse aggregate used in the concrete mix design will conf orm to ASTM C33 with the designated size of coarse aggregate #67. Minimum water/cement ratio will not exceed 0.45. Slump will not exceed 5inches. Air-entraining admixtures will conform to ASTM C260. Water reducing admixtures will conform to ASTM C494, T ype A. b. Reinforcement. All reinforcing steel will conform to ASTM A615 and welded wire fabric to ASTM A185. Reinforcing details shall be in accordance to ACI 318. Minimum cover of 1 on the undersurface of the floor and roof. Full lengths shall be used when possible. Bars will be cold bent  no filed bent allowed. c. Placing and Consolidating Concrete. Concrete will be consolidated by use of mechanical vibrators to accomplish compaction but not to the point segregation occurs. d. Finishing. Interior floor and exterior slabs will be floated and troweled. A light broom finish shall be applied to the exterior and interior slabs. e. Structural Joints. Wall components shall be joined together with two welded plate pairs at each joint. Each weld plate will be 6inches long and located one pair in the top quarter and one pair in the bottom quarter or the seam. Weld plates will be an chored into the concrete panel and welded together with a continuous weld. The inside seams will be a paintable caulk. The outside seams will use a caulk in a coordinating b uilding color or clear. Wall and roof will be joined with weld plates, 3 x 6, at each building corner. The joint between the floor slab and walls will be joined with a grout mixture on the inside, a matched colored caulk on the outside and two weld plate s 6 long per wall. f. Testing. The slump test shall be performed in accordance with ASTM C143. The air content will be in the range of 4.5% +/- 1.75% and checked per ASTM C231. The compressive strength of the concrete shall be tested per ASTM C39. Minimum strength shall b e 7-day 4000 psi minimum and 28-day 5000 psi minimum. A copy of the test reports shall be provided to the Government as soon as 28-day results are available. 5. PLUMBING. a. Waste and vent material will be ABS or PVC plastic. Water material will be copper tubing Type L, hard drawn. b. A gate valve will be provided at the inlet end of the water line. All water lines will be sized to provide proper flushing action for a water pressure of 40 psi. c. All plumbing will be concealed in mechanical room. d. Hose bib available in chase area. e. A main shut-off valve and drain will be provided with plumbing. f. Vitreous china toilets and urinals. Flush valve type toilet, wall hung, with siphon jet action and back spud for concealed flush valve connection. Seat shall be heavy duty solid plastic with an open front. g. Flush valve will be concealed closet flush-o-meter constructed of rough brass. Furnish valve with integral vacuum breaker and wall mounted push button. Valve will be water saver type with flow of 1.6 gallons per flush. h. Standard sink is cast iron with back splashguard, front overflow opening, equipped with brass trap and drainpipe without stopper. Sink is 20 inches wide x 18 inches front to back x 6 inches deep. Vitreous china coating. i. Water valve is self-closing water set with indexed push button. j. ADA accessible where needed. All applicable fixtures will be mounted at heights to meet ADA requirements. k. Shower will be ADA compliant. l. Showerhead will be vandal resistant, 1.5 GPM. m. A minimum 75-gallon water heater is included for the four shower units. A minimum 6-gallon electric hot water heater or instant water heater is included for a 4-toilet/2-sink restroom. n. Optional Hot water heaters. A propane, propane instant, or electric instant hot water heater shall be available as options. Hot water heater shall be of sufficient size and a quick recovery unit for continuous use of all four showers during a three-ho ur period. 6. ELECRICAL/LIGHTING. a. All wiring will be in conduit, surface mounted in service area and concealed in the user compartments. All wire shall be copper. b. A 100-amp breaker panel will be provided in the chase. c. The chase will have two 4-foot ceiling mounted HO fluorescent light fixtures. d. Restroom area will have two 8-foot, 4-bulb ceiling mounted HO fluorescent light fixtures. e. Lighting in exterior will be photocell activated. Interior and chase will be switch activated. f. Outdoor lights above doors will be 35-watt High Pressure Sodium, cast aluminum case. Photocell controlled. g. Hand dryer will be air compression type with remote motor unit. Push button switch located in cast nozzle housing with flexible hose connection blower motor, housing and nozzle. Power input 120 VAC, 7A (non-heated air). h. GFCI outlets will be placed near the sink area as designated by the Government. 7. BUILDING EXTERIOR FINISH. Contractor shall offer several different exterior wall finishes such as barnwood, split face block, stucco, exposed aggregate, batt and board, brick, and wood. The Contractor shall also offer several different roof finishes such as shake or metal-look concrete roofs. A minimum of 25 different colors shall be offered. The Government shall be allowed to choose the color after award of the contract. Two tone color for wall and roof shall be available as an option. The exteri or walls and roof shall be made of color through concrete using color additives conforming to ASTM C979. The walls and roof shall then be covered with a pure acrylic water repellent penetrating stain in the same color as the walls or roof followed by a clear an ti-graffiti sealer. 8. INTERIOR FINISHES. Interior walls and ceilings shall be painted with a modified acrylic penetrating pigment that will be white in color, unless otherwise specified. Paints will not contain more than .06 percent by weight of lead. All paints and mater ials will conform to all Federal specifications or be similar top-of-the line components. As an option, the Government shall be given the option of selecting fiberglass-reinforced panels (FRP) covering for the interior walls. . The standard floor treat ment will be a 1-part water based epoxy with a silica sand suspension to provide non-skid uniform texture that will be gray in color. Tile floors shall be available as an option if specified. 9. Vault Toilet Features. a. Vault. Vault shall be a 4inch thick, one-piece, full length and width of the building (matches the perimeter of the building) unit to support the building, screen area and snow loads evenly. The floor unit shall be one-piece to prevent panels from migr ating during freeze/thaw stress. The vault shall include a one sheet black ABS/752 virgin plastic. The vault liner shall have imbeds to attach the liner to the concrete walls of the vault. Vaults with the ABS liner shall be warranted against leaks for a period of seven years. Vault shall be 1,000 gallons capacity. Vault shall be sloped so that waste will drain to the clean out end of the vault. b. Vault Cleanout Cover. Plate for vault cleanout cover shall be - inch thick diamond plate steel. Lid shall be hinged and configured so that it can be locked with a padlock. A neoprene gasket shall be provided around the entire perimeter of the lid to provide an airtight seal. c. Exhaust Vent Pipe. Vent pipe shall be black plastic and located on the backside of the building, always facing south. Exhaust Pipe Installation. Seal around pipe at tip and underside of roof with silicone caulk. Seal around pipe at top of slab will be accomplished by using silicone caulk. d. Riser. Riser shall be a cross-linked poly riser, handicap accessible. e. Optional Installation. Comply with all OSHA standards for excavation. Excavate to a depth that will allow the structure site to be free draining after installation is complete. Allow for a 2inch leveling course beneath the toilet vault. Finish floo r elevation will be 4-6 inches above natural grade measured at the front entrance of the exterior slab. No excavation shall be left open more than seven days unless otherwise approved by customer. All excavations left open overnight will be fenced with w ire mesh or plastic mesh fence secured to steel posts all around the excavation. Fence must be flush to the ground with maximum post spacing of 10 feet and minimum height of the fence of 36 inches. Ground at the bottom of the vault excavation shall be a minimum of three passes with a whacker-type mechanical compactor or equivalent approved by the customer. Sand or aggregate bedding material (3/8 minus crushed or screened aggregate) shall be used for a leveling course and compacted with one pass of a wha cker-type mechanical tamper or approved equal. Leveling course shall be leveled so there are no high spots in the middle of the vault bottom. Compact with second pass of the whacker tamper. Backfill using excavated material except for rocks larger than 6 inches shall not be placed within 6 inches of the exterior vault walls. Fill adjacent to the building entry will have excavated material placed in eight inch loose lifts and compacted with a minimum of two passes with a whacker-type mechanical compactor or approved equal. Final grade shall be flush with the top of the front slab. Topsoil from the excavations shall be used to r each final grade. Grade backfill away from the structure at a maximum slope of five percent. Areas disturbed by excavation, backfilling and stockpiling of excavated materials shall be hand raked to remove exposed rocks over one inch in maximum dimension. Oversized rocks shall be disposed of in a designated area within 200 feet of the site. Silicone caulk will be applied between the toilet riser flange and concrete floor before the toilet riser is installed. Caulking between vault and toilet floor shall be 1 x 1 Butyl tape. f. Vault units shall incorporate all aspects of Sweet Smelling Technology outlined by Briar Cook for the U.S. Forest Service. 10. ADDITIONAL STANDARD FEATURES. a. Steel Frames. Glazing will be 1/4 inch thick translucent LEXAN polycarbonate. Skylights shall be offered as an optional item. Optional metal screens laminated to the LEXAN windows shall also be offered. b. Ventilation. Wall vent will be cat into the concrete wall. Frame will be C3 x 4.1 channel steel. Louver frame 3/16 x #3 flat bar. Louver is an inverted Y, no vision 2x2x1/8 angle. All steel will be primed and painted with enamel. There will be an insect screen between louvers. c. Doors. Steel doors Flush panel type  1 - thick, minimum 18 gauge prime coated steel panels with minimum 12 gauge internal bracing channels with polystyrene core. Door frames will be knockdown or welded type, single rabbet minimum 16 gauge prime coate d steel, and width to suit wall thickness. Three rubber door silencers will be provided on latch side of the frame. There will be three hinges per door with dull chrome plating, adjustable tension, automatic closing for each door. Door sweep will be an adjustable brush type. Door hardware shall include Grade 1, cylindrical lockset for exterior doors, ADA lever handle both inside and out. Privacy locks with push-button locks on inside shall be provided. Optional Deadbolts shall be provided as an opti on for any door. d. Mirror shall be offered  with option of either glass or stainless steel. e. Grab bars shall be provided for all handicap accessible units. They shall be 18 gauge, stainless steel. f. Toilet Paper Dispenser shall be provided for each toilet. The standard shall be - steel with enamel finish and hold two standard rolls. Larger dispensers shall be available as an option. g. Partitions for Stalls. Partition walls will be 3-inch thick concrete. Stall doors shall be solid phenolic in a standard white color. Optional colors shall be offered. Shower stalls shall each include a phenolic bench. h. Double Coat Hook for each Stall. Each stall shall contain a stainless steel with nail in anchor, double coat hook. i. Optional Utility Room Heater. A wall mounted room heater with internal thermostat shall be offered as an option. j. Optional User Compartment Heater. Wall-mounted, tamper resistant electric heater with internal thermostat shall be offered as an option, if specified. k. Optional Solar Panel with photo cell for lighting l. Signage. Standard sign for unisex and handicap accessible on exterior of building. m. Other. Air vent at top of gable in the rear wall to allow air to escape when building is filled with water during floodwater inundation. n. Optional Skylights  one per compartment shall be offered. o. Optional Foundation preparation. Contractor shall construct gravel pad for water borne buildings as an optional item. Contractor shall provide all equipment, labor and materials to construct the pad. The pad shall be constructed using appropriate com paction of the subgrade to provide a bearing capacity of 1500 PSF minimum and compacted 6 of 3/8 crushed stone base. . p.Optional Utility Installation. Contractor shall include optional utility in stallation, including water, sewer, and electricity, as an optional item. Utilities shall be stubbed up in the building at the proper location for hook up to the building after placement and shall be run to a maximum of 10 feet outside the building footprint and stubbed off for hook up by the Government at a later date. q. Optional Utility Hook up. Contractor shall include optional building utility hook up of water, sewer, and electricity. After the building is placed, the contractor shall complete the final hook-up of the utilities from the stub-up in the building to t he water, sewer, and electric components inside or on the building. The Government will hook up utilities outside the building footprint. FAR CLAUSES INCORPORATED BY REFERENCE: 52.212-1 Instructions to OfferorsCommercial Items, 52.212-2 EvaluationCommercial Items the Government will award a contract resulting from this solicitation to the responsible offeror whose offer conforming to the solicitation will be most advantageous to the Government, price and other factors considered,, 52.212-3 Offeror Representations and CertificationCommercial Items, 52.212-4 Contract Terms and Conditions Required to Implement, 52-212-5 Contract Terms an d Conditions Required to Implement Statutes of Executive OrdersCommercial Items, 52.232-18 Availability of Funds This is a 100% set aside for small business. The applicable NAICS code is 238120 and the size standard is $13.0 million. Plans and specification will be provided on the solicitation. OFFEROR REPRESENTATIONS AND CERTIFICATIONS: Prior to bid, vendors must c omplete online the Representations and Certifications. To do so requires CCR Registration, including an MPIN number. Instructions may be obtained, and required information may be entered, at http://orca.bpn.gov. One must register on the Kansas City Distric t web site in order to receive any quotations. Bids are due August 29,2007 by 2:00 PM (central standard time). Email bids to contact@example.gov or mail hard copy to U.S. Army Corps of Engineers Attn: Carol Hodges 601 E. 12th St Kansas City, MO 64106 REQUIRED CCR REGISTRATION: Prior to bidding, vendors must be actively registered in the Central Contract Registration (CCR) system, including creation of an MPIN number. Registration instructions may be obtained d, and online registration may be accomplish ed, at www.ccr.gov. By submission of a proposal, a vendor acknowledges the requirement to be registered in the CCR database prior to award; during performance; and through final payment of any contract resulting from the solicitation. Refer to CCR clause ( either 252.204-7004 or 52.204-7) Also, Federal Acquisition Regulation (FAR) requires offerors to provide representations and certifications electronically via the BPN website at https:/www.bpn.gov/ocra/vendor as a prerequisite to receiving solicitation, to update the representations and certifications as necessary, but a least annually, to keep them current, accurate and complete, and to make changes that affect only one solicitation by completing the appropriate sections of either paragraph (j) of FAR prov ision 52.212-3 or FAR provision 52.204-8, whichever is included in the solicitation. Questions of a technical nature may be addressed to Sue Gehert at +1 (555) 000-0000. Questions of a Contractual nature may be addressed to Carol Hodges at +1 (555) 000-0000.

More opportunities from Department Of Defense → W071 Endist Kansas City

Same awarding agency

NAICS: 236220
New
Federal
Veterans Affairs St. Louis Health Care System (VASTLHCS) John Cochran (JC) Hospital in St. Louis, Missouri
Solicitation # W912DQ26RA060
The U.S. Army Corps of Engineers Kansas City District is soliciting proposals for an Integrated Design and Construction (IDaC) contract to modernize the Veterans Affairs St. Louis Health Care System John Cochran Hospital in St. Louis, Missouri. This large-scale project involves demolishing deficient buildings and constructing several new seismically compliant facilities, including a new inpatient bed tower, a clinical expansion, an engineering building, a central utility plant, a water tank, and three parking structures. The total construction cost limit for the requirement is 1.42 billion dollars. The project is being solicited as full and open and requires offerors to submit proposals subject to Project Labor Agreement requirements. The contract is structured with a Pre-Construction Services phase (CLIN 0001) with a performance period of 820 calendar days from the Notice to Proceed, followed by various construction options. Award will be made to a single responsible offeror using a best-value tradeoff process, where non-priced factors are significantly more important than price. To be eligible, offerors must achieve at least an acceptable rating for technical factors and small business participation. Required submissions include a proposal guarantee of 20 percent of the proposed price or 3 million dollars, whichever is less, and full payment and performance bonds upon award. Technical requirements mandate compliance with USACE EM 385-1-1 safety standards, LEED v5 building design, and FGI Hospital Guidelines. The scope includes complex deliverables such as a VA swing space and a phased turnover schedule for various medical zones. Offerors must provide a detailed staffing plan, including a Site Safety and Health Officer and a QC Manager, and must utilize a third-party vendor for cybersecurity assessments. Proposals must be submitted electronically in PDF format by November 25, 2026, adhering to strict page limits and formatting guidelines.
Commercial and Institutional Building Construction

POSTED

6 days ago

DEADLINE

in 27 days
View Details
NAICS: 332312
New
Federal
Debris Boom Supply and Install at Harry S. Truman Lake Project
Solicitation # W912DQ26QA080
Solicitation W912DQ26QA080 is a full and open, unrestricted competition for the design, fabrication, delivery, and optional installation of a debris boom system at Harry S. Truman Dam near Warsaw, Missouri. The primary objective of the approximately 2,000-foot boom is to protect the dam's tainter gates from floating debris to maintain spillway operational capacity and serve as a visual barrier for boaters. The system must be USA-made, utilizing domestic materials for all load-bearing components, and must be engineered to withstand specific hydraulic, wind, and wave conditions, including a minimum safety factor of 2.0 and the impact of a 100-foot log. A critical technical constraint prohibits any drilling into, on, or under the earthen dam. The contract is structured with three base CLINs covering design and fabrication, and one option CLIN for installation. Key deliverables include preliminary loading assumptions and drawings within 60 days of award, final professional engineer-stamped specifications and an O&M manual within 120 days, and on-site delivery within 240 to 300 days. Award will be based on the most advantageous offer, evaluating price, relevant experience, and past performance. Quotes must be submitted in PDF format to the designated points of contact by the revised deadline of November 2, 2026, and must include a completed SF 1449, pricing, and the required experience and past performance documentation.
Fabricated Structural Metal Manufacturing

POSTED

6 days ago

DEADLINE

in 4 days
View Details
NAICS: 237110
Federal
Atchison Storm Sewer Separation Improvements, Atchison, Kansas
Solicitation # W912DQ27BA002
The U.S. Army Corps of Engineers, Kansas City District, is soliciting bids for the Atchison Storm Sewer Separation Improvements project in Atchison, Kansas. This small business set-aside construction project, with an estimated value between 1 million and 5 million dollars, involves the separation of storm and sanitary sewers. The scope of work includes the installation of reinforced concrete pipe, reinforced concrete box culverts, and storm water inlets and junction boxes, as well as the removal of existing sewer structures. The contractor is responsible for providing all necessary labor, equipment, and supervision, including incidental grading and the restoration of parkways, driveways, sidewalks, and pavement to a condition equal to or better than the original state. The solicitation is issued as a sealed bid under NAICS code 237110, with a response deadline of November 13, 2026. The project is divided into two primary components: the 16th Street Alignment and an optional 15th Street Alignment. Key requirements include adherence to the City of Atchison Public Works Specifications, compliance with the Davis-Bacon Act, and the submission of a project schedule within 42 days of the notice to proceed. Contractors must provide performance and payment bonds and participate in a partnering session within 45 days of the award. Quality assurance involves inspections of precast concrete units upon delivery and mandatory approval of saddle installations by the Contracting Officer's Representative prior to backfilling.
Water and Sewer Line and Related Structures Construction

POSTED

9 days ago

DEADLINE

in 15 days
View Details
NAICS: 562910
Federal
SB ERS MATOC, USACE Northwestern Division and EPA Region 2
Solicitation # W912DQ26RA109
The U.S. Army Corps of Engineers, Kansas City District, is establishing a Multiple Award Task Order Contract (MATOC) for Environmental Remediation Services (ERS) to support the USACE Northwestern Division and EPA Region 2. This total small business set-aside under NAICS 562910 has a maximum value of 245 million dollars, with a minimum guarantee of 2,500 dollars per contract. The period of performance runs from June 4, 2027, to June 3, 2032, with a six-month extension option available through December 3, 2032. The scope of work is extensive, covering in-situ thermal and chemical remediation, operations and maintenance of groundwater treatment and soil vapor extraction systems, field investigations, remedial design, risk assessments, and support for abandoned mines programs. Task orders will be executed as either Firm Fixed Price or Cost Plus Fixed Fee. This is a competitive, best-value acquisition utilizing the Highest Technically Rated Offeror with Reasonable Price methodology. Proposals are evaluated based on corporate experience and past performance, with awards granted to the highest technically rated offerors whose pricing is determined to be fair and reasonable; no price-technical tradeoffs will be performed. Offerors must submit two separate electronic PDF volumes via the PIEE Solicitation Module. Contract administration requires the use of the Wide Area WorkFlow system for invoicing and adherence to strict quality standards, including the preparation of Contractor Quality Control Plans and Quality Assurance Project Plans for each task order.
Remediation Services

POSTED

20 days ago

DEADLINE

in 18 days
View Details

Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS