Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, September 2 at 2:00 PM EDT

Register Free →

E2 (UEM) YSK-J209 REPLACE DEAERATOR

Active
Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

General Info

Agency

Department Of The Navy → Navfac Far EastView Agency

NAICS

N/A

Place of Performance

USA

Set-Aside

NONE

Documents

(0)

No documents available

AI Contract Breakdown

Uniform Contract Format

No contract breakdown available.

Cannot generate Contract Breakdown because no documents were found from this contract's source.

Timeline

Posted

forecast

Ready to pursue this opportunity?

Start your free trial to track this contract, build proposals with AI assistance, and manage your pipeline.

Organization & Contact Information

Show more
AgencyDepartment Of The Navy → Navfac Far East
ContactsNo contacts available
OfficeN/A
Organization / Agency
Department Of The Navy → Navfac Far East
View Agency Profile
Office AddressN/A
ContactsNo contact information available

Full Description

Show more
Project Title: E2 (UEM) YSK-J209 REPLACE DEAERATOR 1) Desired Completion Date: FY26 3) Fund Source: CNIC 4) Supported Customer: NAVFAC FE UEM 5) When funds will be available: 6) Work Priority: 2 Scope of Work: Replace and provide new deaerator assembly (deaerator tank, steam pressure control valve, feed water control valve, miscellaneous piping and gauges), top/bottom platform/railings and other portions of the base frame (severely corroded) to include pipe insulation/cladding Justification / Reason: Steam outage in J-Areas. Total steam capacity in CFAY (3 boiler plants) is 207ton/hr; J209 boiler plant is responsible for 36% steam production overall in CFAY that serves: (J area) Admin buildings, DODEA schools, NEX, Family Housing and Navy Lodge. Severe corrosion of platforms and railings are unsafe during daily checks/services. Deaerator installed in 2007 and has exceeded the average lifespan for boiler equipment and has severely corroded. Boiler deaerators must condition feed water to remove dissolved gases before it can be used in the boiler system, to protect the steam network and prevent corrosion and failure. Recommendation / Information /Special REPLACE WITH YSK-A43 SPECS: DEAERATOR AND STORAGE TANK Deaerator (50 m3/h) MAKE: HOT SPRAY SER: 35DH09 EXISTING: DEAERATOR AND STORAGE TANK, JD-01; Deaerator (50m3/h); MAKE- SHINEI MODEL-DSQ50-1 5; SER-TSQ708 CONTROL VALVE, JDSFCV-01; Steam flow control valve for deaerator(98kpa); MAKE-AZBIL; MODEL-HCB; SER-R-J2AM7-41-011 CONTROL VALVE, JDWFCV-01; Feed water flow control valve for deaerator (98kpa); MAKE-AZBIL; MODEL-HCB; SER-R-J2AM7-41-021