Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, October 28 at 2:00 PM ET

Register Free →

This Solicitation opportunity from Washington was posted on August 17, 2026. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

ELECTRICAL ENGINEERING SERVICES

Closed
2026-RFQ-028State & Local

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

AI Contract Overview

Show more

The King County Library System (KCLS) is soliciting statements of qualifications under RFQ 2026-RFQ-028 for electrical engineering services to design a backup power system for the North Bend Library. The facility is approximately 9,774 square feet and requires a system capable of maintaining lighting, HVAC, and core service operations for up to thirty-six hours during utility outages. The design must incorporate solar panels, battery systems, and a generator if necessary, featuring an automatic transfer from utility power. The scope of work is divided into four primary phases: planning and feasibility, design and engineering, procurement support, and construction consulting, including final field inspections and commissioning oversight. Qualified firms must provide a lead project manager and a lead professional engineer licensed in Washington State. Submittals are due by September 21, 2026, via the OpenGov portal and must include a letter of introduction, an organizational chart, resumes of key personnel, examples of similar projects, three references, and a statement regarding affirmative efforts for equitable opportunity. KCLS will evaluate firms based on demonstrated competence and specialized experience in designing backup power systems for public spaces in outage-prone areas. Contracts will be negotiated based on qualifications at fair and reasonable prices, with a preference for firms showing expertise in this specific field.

General Info

KCLS seeks electrical engineering services for North Bend Library backup power system design.

Place of Performance

WA, USA

Set-Aside

NONE

Documents

7

2026-RFQ-028 Electrical Engineering Services RFQ

PDF, High priority: read this firstrfq
High

2026-RFQ-028 KCLS Electrical Engineering Consulting Services

PDF, High priority: read this firstrfq
High

KCLS RFQ 2026-RFQ-028 Electrical Engineering Services

PDF, High priority: read this first7 pages · rfq
High

RFQ 2026-RFQ-028 Electrical Engineering Services

PDF, High priority: read this first7 pages · rfq
High

Project 2026-RFQ-028 North Bend Library Vendor Questions

DOCX, Low priority1 page · q-and-a
Low

DJC__Bid_Advertisement_for_Request_for_Qualifications_-_King_County_Library_System_RFQ_2026-RFQ-028_.msg

MSG

Seattle_Times_Ad.jpg

JPG

AI Contract Breakdown

Uniform Contract Format

Sign up to view the full breakdown with detailed analysis of each section.

Timeline

PhaseClosed
Posted

Solicitation

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyWashington → FIN - Facilities
Contacts2 people available
OfficeIssaquah, WA, 98027, USA
Organization / AgencyWashington → FIN - Facilities
Office AddressIssaquah, WA, 98027, USA
Contacts
Shelbi ArcherContract and Special Projects Coordinator
Erin AuProject Specialist II - Procurement & Contracts

Interested Companies (21)

GlumacLos Angeles, CA
HV Engineering
PAEPortland, OR

See All 21 Interested Companies

Get full access to view all interested companies, their contact details, and full contractor profiles.

Get full access

Full Description

Show more
Date of Issuance : Project Release Date Submittal Due Date: Response Submission Date at Response Submission Time Point of contact : Further details are available from Procurement Contact Full Name at contact@example.gov. Project Description and Background: The King County Rural Library District dba King County Library System (KCLS) requests the submittal of statement of qualifications for the following project: Design of a backup power system capable of operating the North Bend Library's - lighting, HVAC systems, core service operations for up to thirty-six hours during utility outages the design solution should include solar panels, battery system, and generator, if required the system should include automatic transfer from utility power when service is not available The North Bend Library is approximately 9,774 SF located at 115 E 4th Street, North Bend, WA 98045 . Services required are expected to include the following: • Planning & Feasibility: o Review existing information and perform a site audit and power use analysis for the Project. o Consider KCLS's service levels, space utilization, and site security considerations, during power outages in the area. o Verify site suitability and factors that may influence constructability and costs. • Design & Engineering: o Provide all design phase services. o Produce plans, specifications, cost estimates and timelines necessary for construction. o Coordinate systems with existing HVAC, electrical, security, and telecommunications systems. o Consult with and update KCLS Facilities Staff. • Procurement: o Once authorized, provide Bid services including but not limited to bid document administration, pre-bid meeting, responding to requests for information, issuing addendum, review of bids and recommendation to award. • Construction Consulting: o Once authorized, provide ongoing full Engineering consulting services including but not limited to review of submittals, requests for information, change orders evaluations, and final field inspections/commissioning oversight. The chosen firm will also be available to the contracted installation vendor to answer questions that arise as part of typical construction. KCLS will negotiate contracts for consulting and engineering services for the project on the basis of demonstrated competence and qualification for the type of professional services required at fair and reasonable prices. Preference will be given to submittals showing experience and expertise designing backup power systems serving public spaces in areas prone to power outages. Firms engaged in the lawful practice of electrical consulting and engineering are also encouraged to submit a statement of qualifications and performance data annually to KCLS. KCLS will evaluate current statements of qualifications and performance data it has on file, together with those that are submitted for this specific proposed project.

More opportunities from Washington → FIN - Facilities

Same awarding agency

NAICS: 236220
SLED
KING COUNTY LIBRARY SYSTEM: REIMAGINING SPACES AT KENT LIBRARY - PHASE 2 GENERAL CONTRACTOR
Solicitation # 2026-ITB-036
The King County Library System is soliciting bids for the Phase 2 General Contractor services to perform a full interior renovation of the Kent Library, located at 212 2nd Ave N, Kent, WA. The project involves approximately 22,600 square feet of interior renovation and tenant improvement work. The facility will be closed to the public and unoccupied during construction. The owner's estimated base bid range is between 3.25 million and 3.9 million dollars, with a required performance period of five months from the issuance of the Notice to Proceed. The contract is governed by AIA Documents A101-2017 and A201-2017, and requires compliance with RCW 39.12 prevailing wage laws, the Buy American Act, and the Build America Buy America Act. Bidders must provide a bid bond of at least 5 percent of the total bid and subsequent performance and payment bonds at 100 percent of the contract sum. Award decisions will be based on price, references from three similar projects, and the completion of all ITB requirements. Bids must be submitted via the OpenGov portal by November 2, 2026, at 10:00 am. Contractors are responsible for all construction means and methods and must provide monthly invoicing using AIA Forms G702 and G703, with separate itemized charges for labor and materials. Key deliverables include finalized project record drawings and all necessary signed permits. Quality standards are strictly defined, including NFPA 70 for electrical labeling, SMACNA for HVAC ducts, and ANSI/AWI for countertops. Final acceptance is contingent upon the submission of project records and, for specific systems, inspection by an authorized Duro-Last Quality Assurance Technical Representative.
Commercial and Institutional Building Construction

POSTED

13 days ago

DEADLINE

in 5 days
View Details

Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS