Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, December 9 at 2:00 PM ET

Register Free →

This Subcontract opportunity from Department Of Defense was posted on February 19, 2026. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

Failure Modes and Effects Analysis (FMEA) & System Safety

Closed
Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 541330
New
SLED
PNA-484-010627 Pavement Evaluation Services
Solicitation # PNA 484-010627
The Georgia Department of Transportation is soliciting Pavement Evaluation Services for interstate maintenance across three distinct contracts. Contract 1 covers Region 1 (District 7), Contract 2 covers Region 2 (Districts 1, 3, and 6), and Contract 3 covers Region 3 (Districts 2, 4, and 5). The scope of work involves field analysis, laboratory analysis, and the generation of reports for concrete rehabilitation and maintenance resurfacing projects. Technical requirements include Falling Weight Deflectometer (FWD), Ground Penetrating Radar (GPR) and 3-D GPR, and Traffic Speed Deflectometer (TSD) testing and analysis. Additionally, AASHTOWare Pavement ME Design Analysis, Calibration, and Verification is required specifically for Region 1, District 7. This opportunity was initiated via a Public Notice of Advertisement on November 12, 2026, with the formal Request for Qualifications (RFQ) scheduled for issuance on December 9, 2026. Statements of Qualifications are due by January 6, 2027, and should be directed to Tori Butler at the Georgia Department of Transportation in Atlanta. A strict communication restriction is in effect from the advertisement date until the official award; firms are prohibited from discussing the solicitation or scope with any GDOT staff, including the Commissioner and Board Members, under penalty of rejection. Anticipated key personnel for the project include leads for pavement design, pavement evaluation, laboratory testing, and various specialized deflectometer and radar analysis.
Department of Transportation-2

POSTED

about 8 hours ago

DEADLINE

in 27 days
NAICS: 541330
New
International
100 – 600 BLOCK E 6TH STREET WATER AND SANITARY SEWER MAIN UPGRADES
Solicitation # 235792
The City of North Vancouver is soliciting proposals for design, tender, and contract administration services to upgrade water and sanitary sewer mains in the 100 to 600 blocks of East 6th Street. The project scope involves the replacement of approximately 1,410 meters of watermain and 1,410 meters of sanitary sewer main. The required services are divided into detailed design, construction documentation, and tender preparation, with optional components for contract administration and inspection services. All work must comply with CNV standards, relevant Federal and Provincial requirements, and utilize MMCD 2019 for supplementary specifications and the schedule of quantities. Proposals will be evaluated by a selection committee based on project team and relevant experience (30%), methodology and project understanding (25%), fees and disbursements (20%), project management approach (15%), references (5%), and sustainability (5%). Bidders must provide a detailed estimate of fees and disbursements, including a maximum upset price for each stage of the project. Submissions must be sent as a single PDF to [email hidden] by 4:00 PM local time on May 17, 2026. Proponents are required to submit a signed proponent commitment and are expected to comply with the CNV Supplier Code of Conduct, the Living Wage for Families Campaign, and the CNV Fair Wage Policy for construction activities exceeding $250,000.
City of North Vancouver

POSTED

about 9 hours ago

DEADLINE

in about 1 month

AI Contract Overview

Show more

This subcontract opportunity, issued by the Department of Defense through the FA9101 Aedc Pkp Procrmnt Branch, requires the performance of a Failure Modes and Effects Analysis (FMEA) and system safety evaluation. The primary objective is to conduct a comprehensive FMEA for the entire heated air supply system to identify potential risks and develop effective mitigation strategies. The work is categorized under NAICS code 541330 and will be performed in Coopertown, Tennessee. Interested parties must submit their responses by the deadline of March 6, 2026, at 4:00 PM. The solicitation was officially posted on February 19, 2026. This project focuses on ensuring the operational safety and reliability of critical heating infrastructure through rigorous technical analysis.

General Info

NAICS

541330 - Engineering Services

Place of Performance

COOPERTOWN, TN, 37389, USA

Set-Aside

NONE

Documents

This scope was carved out of FA9101-26-9-Heated_Air_Supply.

The full solicitation package (2 documents), including the RFP, is on the prime solicitation, not on this scope.

View the prime solicitation

Heated Air Supply – Market Intelligence Request

AI Contract Breakdown

Uniform Contract Format

No documents to break down

The breakdown needs solicitation documents. None were found from this contract's source.

Timeline

PhaseClosed
Posted

subcontract

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Defense → FA9101 Aedc Pkp Procrmnt Branch
ContactsNo contacts available
OfficeN/A
Office AddressN/A
ContactsNo contact information available

Full Description

Show more
Conduct FMEA for the entire heated air supply system to identify risks and mitigation strategies.

More opportunities from Department Of Defense → FA9101 Aedc Pkp Procrmnt Branch

Same awarding agency

NAICS: 332996
New
Federal
Large Diameter Flex Duct Bellows
Solicitation # FA9101LDFDB
The Department of Defense, through the Arnold Engineering Development Complex at Arnold AFB, Tennessee, has issued a Sources Sought Notice to identify capable businesses for the procurement of two new, fully functional Large Diameter Flex Duct Bellows Assemblies. These assemblies must feature a 45.315-inch internal diameter and be fabricated from silicone-coated 1523 fiberglass with a 6-ply body and a nominal thickness of 0.12 inches. The technical requirements specify a working pressure of 30 psid internal and 15 psid external, with an operational temperature range from -60°F to +450°F. Fabrication must adhere to EJMA Standards, ASME Boiler and Pressure Vessel Code, and Drawing RJ632279.18, with welds inspected per AWS D1.1. Refurbished or remanufactured parts are strictly prohibited. The contractor is responsible for all materials, labor, equipment, and transportation, including the provision of supports, cribbing, tie downs, and weather protection to ensure safe delivery to Arnold AFB. Required deliverables include a comprehensive documentation package consisting of visual, weld, and pressure test inspection reports, axial spring rate calculations, and a standard manufacturer warranty. Assemblies must undergo hydrostatic testing to 45 psig at 70°F. Interested respondents must submit their company information, SAM Unique Entity Identifier, Cage Code, business size, and a tailored capability statement to the designated points of contact by November 19, 2026.
Fabricated Pipe and Pipe Fitting Manufacturing

POSTED

3 days ago

DEADLINE

in 6 days
View Details
NAICS: 332912
New
Federal
Tunnel 9 Pitch Upgrade
Solicitation # FA9101T9PU
The Arnold Engineering Development Complex (AEDC) requires the comprehensive modernization of a high-performance hydraulic motion system for Tunnel 9 located in Silver Spring, Maryland. This 100% Small Business Set-Aside is a Firm-Fixed-Price contract encompassing the design, engineering, procurement, off-site fabrication, pre-assembly, on-site demolition, installation, and commissioning of core system components. Key hardware requirements include a primary control valve with a step response time of 55 ms or less, a main actuating cylinder with a 120.5-inch working stroke capable of 13 ft/s linear speed, a Hydraulic Power Unit (HPU), and a dedicated filtration and cooling kidney loop. All components must adhere to ASME B31.1, ASME BPVC VIII, and ISO 4406 standards, with specific requirements for near-vacuum environment reliability and compatibility with DTE-26 Ultra hydraulic oil. The project is structured into three distinct phases: Engineering Design, Part Procurement and Pre-assembly, and Demolition, Installation, and Commissioning. The total period of performance is 46 weeks from the lead time event. Award will be based on a combination of technical capability, past performance on similar hydraulic systems, and price reasonableness. Contractors must meet CMMC Level 1 (Self) cybersecurity requirements and possess the ability to handle Controlled Unclassified Information (CUI). Rigorous quality controls are mandated, including hydrostatic pressure testing, live performance demonstrations witnessed by AEDC, and strict adherence to MIL-STD-130 and MIL-STD-129 for item marking and shipment. Payment will be processed electronically via the Wide Area WorkFlow (WAWF) system.
Fluid Power Valve and Hose Fitting Manufacturing

POSTED

7 days ago

DEADLINE

in 27 days
View Details
NAICS: 333517
Federal
Large CNC EDM Sinker
Solicitation # FA9101_LARGE_CNC_EDM_SINKER
The Department of Defense, through the Arnold Engineering Development Complex (AEDC) at Arnold Air Force Base, Tennessee, has issued a Sources Sought Notice to identify capable small and large businesses for the procurement of a new, fully functional Large CNC EDM Sinker. This requirement strictly prohibits the use of refurbished or remanufactured parts. The selected contractor must provide all materials, labor, and equipment to deliver the machine FOB Arnold Air Force Base, with a required delivery timeline of four months from the receipt of order. The scope includes installation at the Model Shop in Building 451, supervised by factory-trained servicemen, and the provision of two days of formal training for three individuals on machine controls and operation. Technical specifications require the machine to be built to NFPA 79 standards and compatible with a 480V, 3PH, 60 HZ power system. Post-delivery, the contractor must perform functional accuracy tests according to ISO/ANSI standards, ensuring repeatability and positioning within +/- .0001”. The contract includes a 24-month warranty on materials and workmanship, a ten-year accuracy guarantee on the Linear Drive System, and strict support requirements, including a 36-hour on-site repair response time and 48-hour delivery for repair parts. Interested respondents must submit company information, SAM data, a capabilities statement, a rough-order-of-magnitude budgetary estimate, and a projected delivery schedule by November 13, 2026.
Machine Tool Manufacturing

POSTED

8 days ago

DEADLINE

in about 15 hours
View Details

Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS