Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, November 11 at 2:00 PM ET

Register Free →

This Pre-Solicitation opportunity from General Services Administration was posted on June 17, 2009. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

Furnish and instal fire alarm monitoring devices and provide fire alarm monitoring services at four (4) locations as specified in the Scope of Work.

Closed
3PPE-09-BID-003Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 922160
SLED
2026 Volunteer Fire Capacity Grant
Solicitation # 2139681
The New York State Department of Environmental Conservation is administering the 2026 Volunteer Fire Capacity Grant Program, funded by a federal appropriation of 857,629 dollars. This program provides matching grants to eligible rural fire departments for the purchase of wildland firefighting suppression supplies. To be eligible, departments must be comprised of at least 80 percent volunteer personnel and serve a rural area, defined as a town or village with a population of 10,000 or less based on the 2020 Census. Selected departments can receive a maximum award of 3,500 dollars, which must be matched 50/50 by the recipient. Grant funds must be used for items directly related to wildland firefighting that benefit the local rural community, with a restriction that no individual item exceeds 9,999 dollars. Selection is based on the department's funding history over the previous five years, whether it is a newly formed establishment, and the presence of a Native American community within its jurisdiction. The program operates under federal guidelines from the US Forest Service and the Cooperative Forestry Assistance Act of 1978. Applications are accepted through December 30, 2026. This solicitation does not have specific goals for Service-Disabled Veteran-Owned, Minority, Women, or Disadvantaged Business Enterprises. All inquiries and applications are managed by the Volunteer Fire Capacity Grant Coordinator within the Division of Forest Protection.
NYS Department of Environmental Conservation

POSTED

9 days ago

DEADLINE

in 2 months

General Info

NAICS

922160 - Fire Protection

Place of Performance

William J. Green, Jr. FB, 600 Arch St.; James A. Byrne Courthouse, 601 Market St.; U.S. Custom House, 200 Chestnut St. & Robert, PHILADELPHIA, PA, 19106, USA

Set-Aside

NONE

Documents

27

Appendix 1-3: Technical Proposal and Evaluation Sheets

PDF, High priority: read this firstpast-performance
High

GSA East Phila Solicitation SF-33

PDF, High priority: read this firstrfb
High

GSA Form 3503 - Representations and Certifications

PDF, High priority: read this firstrepresentations-and-certifications
High

Scope of Work - Fire Alarm Monitoring Services - GSA East Philadelphia

PDF, High priority: read this firstsow
High

2166.doc

DOC

3502.doc

DOC

3504ref.doc

DOC

52.204-6+Data+Universal+Numbering+System+%28DUNS%29.doc

DOC

52.212-1+Instructions+to+Offerors+-+Commercial+Items.doc

DOC

52.213-4+Terms+ans+Conditions-Simplified+Acquis.+%28Other+Than+Comm.+Items%29.doc

DOC

52.232-33+Payment+by+Electroinc+Funds+Transfer.doc

DOC

FAR+52.219-6+%26+FAR+52.219-14.doc

DOC

FAR+clauses+for+Options.doc

DOC

Fire+Alarm+Monitor+2009+to+2013+Specs.doc

DOC

GSA+Letterhead+non-response+letter.Template.doc

DOC

METHOD+OF+AWARD.doc

DOC

SECTION+A.doc

DOC

SECTION+B.doc

DOC

SECTION+F.doc

DOC

SECTION+F+Place+of+Performance+Verbage.doc

DOC

SECTION+H.doc

DOC

SECTION+I.doc

DOC

SECTION+K.doc

DOC

SECTION+M.doc

DOC

Security+Requirements+Clearance+of+Personnel.doc

DOC

Service+Wage+Determinaiton+05-2449+dated+5_29_08.doc

DOC

SOLICITATION+FOR+OFFERS+cover+page.doc

DOC

AI Contract Breakdown

Uniform Contract Format

Contract not broken down yet

CLEATUS splits the solicitation into Uniform Contract Format (UCF) sections: scope, pricing, deliverables, and evaluation criteria.

Timeline

PhaseClosed
Posted

Presolicitation

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyGeneral Services Administration → Pbs R3 Philadelphia Field Office
Contacts2 people available
OfficePHILADELPHIA, PA, 19106, USA
Office AddressPHILADELPHIA, PA, 19106, USA
Contacts
Karen M. SimsAcquisition Manager/CO
James G. BegleyCosntruction Rep.

Full Description

Show more
SPECIFICATION, FIRE ALARM MONITORING 1. GENERAL Furnish and install fire alarm monitoring devices and provide fire alarm system monitoring services at four (4) locations as specified below. - 2. Installation - 2.1 Connect the existing fire alarm systems to a UL approved fire central station monitor via a UL listed Digital Alarm Communicator Transmitter (DACT) in accordance with NFPA 72 and direct telephone line (s). - 2.1.1 THE DACT and the transmission lines shall be continuously monitored by the central station monitoring service for trouble conditions within the communication circuits. The central station monitoring service shall continuously monitor for both alarm and supervisory conditions on each building's fire alarm system through the DACT. - 2.1.2 Direct telephone line is to be constantly monitored and UL "AA" rated. - 2.2 Coordinate access to existing fire alarm panels with the Government's Representative and existing monitoring company. - 2.2.1 Arrange for the identification of existing and/or provision of new output points (dry contacts) in the existing fire alarm control panel as necessary to achieve the required Alarm and Supervisory output signals. - 2.3 Furnish and install all materials and labor required to provide power for the DACT in accordance with the NEC and NFPA 72, Life Safety Code provisions relating to fire protecting systems. - 2.4 Arrange for and coordinate the installation and activation of all necessary telephone wiring and connection devices. - 2.4.1 All costs associated with the initial installation and all recurring service charges for the telephone line and connection devices referenced in Paragraph 2.4 are to be included in the monthly charges associated with the monitoring system. - 2.4.2 Telephone line (s) to be dedicated to the exclusive use of the monitoring system. - 2.5 Where practical and with the approval of the Government, existing conduit and junction boxes may be reused. - 2.6 Location of the DACT device to be adjoining to the existing fire alarm system cabinet or within the room housing the fire alarm system control cabinet. 2.6.1 Location to be subject to the Government approval. - 2.7 Upon completion of the installation at each location, a satisfactory test shall be Made in the presence of a representative of the Government. - 3. Locations - 3.1 One (1) monitoring system to be completely installed, powered and fully operational in each of the following building: (1) U. S. Custom House, 2nd & Chestnut Streets; (2) Nix FB & Courthouse, 9th & Market Streets; (3) U.S. Byrne Courthouse, 601 Market Street, and (4) Green Federal Building, 600 Arch Street. 3.1.1 All buildings are located in the central business district of Philadelphia. - 4. Effective Date All equipment systems and monitoring services to be fully operational effective October 1, 2009 and shall continue for the entire length of the contract (base and option years.). - 5. Maintenance All equipment (DACT and telephone apparatus) to be furnished to the Government as a lease with all maintenance, service, parts and labor to be included in the monthly charges. - 6. Repairs - 6.1 Necessary repairs shall commence within four (4) hours of identification on notification of a need for service, and shall continue until completed. - 6.2 GSA shall be notified immediately upon identification of the need for a repair. - 7. Monitoring Service Note: Identify the specific building by name and address when reporting fire conditions to the following officials: 7.1 Upon receiving a fire ALARM signal, the Philadelphia Fire Department shall be notified immediately (within 90 seconds). Notify the Fire Dept. only upon receipt of an ALARM condition; a SUPERVISORY condition shall NOT be reported to the Fire Dept. 7.2 Notify Department of Homeland Security (DHS), Regional Control Center at +1 (555) 000-0000, within (3) three minutes of receiving a fire ALARM or SUPERVISORY signal. The notification must be a combination of verbal and digital communication. - 7.3 Notify (LB&B Associates, Inc.), the Building Engineer, at +1 (555) 000-0000 within (5) five minutes of receiving a fire ALARM or SUPERVISORY signal at the Byrne Courthouse and Green FB at any time of the day or night. - 7.4 Notify the Customer Service Desk on +1 (555) 000-0000 within (5) minutes of receiving a fire ALARM or SUPERVISORY signal at the Nix FB and Custom House. Notification only required during working hours between 7:00am-5:30pm. - 7.5 Notify the Customer Service Desk on +1 (555) 000-0000 within (5) minutes of receiving a fire ALARM or SUPERVISORY signal at the US Customs House. Notification only required during working hours between 7:00am-5:30pm. - 8. Reporting Requirements Within five (5) working days after the end of every month, a written report shall be submitted to GSA indicating all activity for that month including: fire alarm, supervisory and communication line trouble conditions received and the date, time and location of each along with a description of the action(s) taken. The monthly payment will not be authorized until this report is received. General Services Administration William J. Green Jr., Federal Building 600 Arch Street, Room 4200 Philadelphia, PA 19106 Attn: Karen Sims Office: +1 (555) 000-0000 Fax: +1 (555) 000-0000 - 9. Past Performance Requirements The Contractor shall provide with the price quote at least three (3) projects of similar size and magnitude for fire system monitoring. Each project submitted shall provide the following information. 1 - Building Name 2 - Reference Name 3 - Reference telephone Number. - 10. Payment Payment will be made on a calendar month basis in arrears upon submission of an invoice. Invoices shall be submitted on the first of each month to: General Services Administration Region 7 Finance Division, (7BCP) P.O. Box 17181 Fort Worth, TX 76102 Any inquiries regarding payment shall be directed to the above address. Invoices shall contain the following information: - 1. Name and address of the contractor. - 2. Invoice date - 3. Contract Number - 4. Services provided and monthly price. - 5. Payment terms (prompt payment discounts). - 6. ACT Number - 11. Contract Completion Upon contract completion or termination, all monitoring equipment and telephone lines are to be removed from the site at no additional cost to the Government and in full coordination with the succeeding vendor to insure uninterrupted monitoring services. - 12. Inspection of Site (s) To arrange access to the building (s) to inspect the on-site conditions prior to submitting an offer, contact: James G. Begley Property Manager GSA, East Philadelphia Field Office William J. Green, Jr., Federal Building 600 Arch Street, Room 4200 Philadelphia, PA 19106 +1 (555) 000-0000

Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS