This Sources Sought opportunity from Department Of Veterans Affairs was posted on February 19, 2026. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

H946--Water Treatment Base + 4

Closed
36C25026Q0323Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 221310
New
Federal
Water Treatment Chemicals, Testing, Monitoring, and Reporting- Sources Sought Notice / Request for Information
Solicitation # 15B70027PR000089
The Federal Bureau of Prisons (FBOP) is conducting market research to establish a Blanket Purchase Agreement (BPA) for comprehensive water treatment chemicals, testing, monitoring, and reporting services for its correctional institutions nationwide. The scope includes the supply of treatment chemicals and the provision of technical support for steam and hot water boilers, chiller water loops, cooling towers, and domestic water systems. Key requirements include monthly testing and reporting for boiler and chiller systems, as well as quarterly domestic water testing for Legionella, E. coli, lead, arsenic, nitrates, and PFAS. The contractor must be capable of implementing treatment recommendations and delivering chemicals within 15 calendar days of test results. A critical component of the requirement is the maintenance of a secure, web-based online reporting portal that provides institution-level, regional, and central office access for tracking water quality dashboards, chemical usage, and compliance trends. All services and materials must adhere to a rigorous set of standards, including EPA, CDC, OSHA, NFPA, ASHRAE Standard 188, and various federal, state, and local codes. Deliveries to institutions must be made between 8:00 a.m. and 2:00 p.m., Monday through Friday. The government is seeking capable vendors who can manage large-scale, multi-site programs and maintain a valid SAM.gov status, with payments processed via Purchase Order or government credit card.
National Acquisitions - Co

POSTED

3 days ago

DEADLINE

in 18 days
NAICS: 221310
New
Federal
4610--FY27 Portable Reverse Osmosis (RO) Water Purification System
Solicitation # 36C24827Q0114
The Department of Veterans Affairs, Network Contracting Office 8, intends to award a sole-source, firm-fixed-price contract to Evoqua Water Technologies LLC for the procurement and installation of brand-name only EON portable reverse osmosis water purification systems. This requirement is specifically for eight EON Portable RO and ROVER ALX transport system kits to be installed on Government-owned EON rover carts at the Orlando VA Veterans Hospital. The scope of work includes the delivery, installation, and start-up of the kits, the provision of two spare carbon block filter cartridges per kit, and the delivery of onsite clinical and technical training and orientation. The contractor is responsible for providing all necessary labor, tools, materials, supervision, and transportation to complete the turnover to the Government. The contract falls under NAICS Code 221310, which has a small business size standard of 41 million dollars. Delivery is requested within 90 days after receipt of order. As this is a brand-name-only requirement based on the determination that only one responsible source can provide the specialized equipment, this notice serves as an intent to award rather than a solicitation for quotes. Interested parties wishing to challenge the sole-source determination must submit a capabilities statement providing clear and convincing evidence that competition is in the best interest of the Government to Susan Rodriguez-Perez by November 20, 2026.
248-NETWORK Contract Office 8 (36C248)

POSTED

3 days ago

DEADLINE

in 5 days

General Info

NAICS

221310 - Water Supply and Irrigation Systems

Place of Performance

Dayton VA Medical Center, Dayton, OH, 45428, USA

Set-Aside

NONE

Documents

1
DOCX, High priority: read this first6 pages · sources-sought
High

AI Contract Breakdown

Uniform Contract Format

Sign up to view the full breakdown with detailed analysis of each section.

View Full Breakdown

Timeline

PhaseClosed
Posted

Sources Sought

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Veterans Affairs → 250-NETWORK Contract Office 10 (36C250)
Contacts1 person available
OfficeDAYTON, OH, 45428, USA

Full Description

Show more
The Dayton Veterans Administration Medical Center (VAMC), Dayton, OH, has a requirement for the contractor to provide parts, material, labor, and supervision, to provide water management testing, treatment, and monitoring services necessary to protect all water systems for domestic hot and cold water, steam, chillers, cooling towers, boilers, ice machines, reverse osmosis systems, and hydronic heating and chilled water systems by means of a firm-fixed-price contract with a base year and four (4) one-year option periods to be exercised at the discretion of the Government.
The intention of this Sources Sought is to obtain information only. Please do not send a proposal.
Requested information: To aid acquisition planning, we re seeking capable and interested firms for the information requested. If your firm meets the criteria and would like to take in the selection process please send the point of contract (Sign up to see this detail) the following, via email:
Firm s Name and Socio-Economic Status.
STATEMENT OF WORK (SOW)
1. Contract Title. Water Management Contract
2. Background: Contractor must provide all parts, material, labor, and supervision, to provide water management testing, treatment, maintenance and monitoring services necessary to protect all water systems for domestic hot and cold water, steam, chillers, cooling towers, boilers, ice machines, reverse osmosis systems, and hydronic heating and chilled water systems. A site visit will be necessary. Information will be forthcoming. 3. Scope: Provide continuous Legionella protections (Buildings 320, 330, 350, and 410) via Monochloramine secondary disinfection with Sanipur monochloramine generators on domestic hot and cold water. Provide continuous monitoring of domestic hot and cold-water distribution systems with Sanipur SaniWare remote monitoring panels. Sanipur systems must be capable of monitoring 24/7 through a cellular modem which the Dayton VAMC will have access to. Provide continuous water quality of boiler and cooling tower systems with live feeds in chiller and boiler plants. Provide chemical treatment for boilers and chillers with solid chemistry. Provide initial cleaning of cooling towers and annual cleaning thereafter. Provide semiannual preventative maintenance to all campus ice machines. Provide preventative maintenance to all reverse osmosis systems and water softeners. Contractor must be contractor must be on-site within two hours of notification to ensure prompt emergency response. Must strictly adhere to latest versions of ANSI/AAMI ST108- Water for Processing Medical Devices and VHA Directive 1061 Prevention of Health Care Associated Legionella Disease and Scald Injury from Water Systems.
4. Specific Tasks: Vendor will report to Robert Rhoad in the engineering department prior to and immediately after completion of inspection and testing. Worker(s) will wear identification badges provided by VA when working on the VA campus or VA leased property. Keys may be picked up in B-128, room 133A. Keys are to be returned to B-128, room 133A at the end of each day. Water Treatment
CHILLER PLANT
Provide continuous monitoring using cellular/cloud-based water treatment technology. All chemicals used need to be in solid form. Provide and add scale and corrosion inhibitor as needed based on water usage. Provide and add dispersant for biological growth as needed based on water usage. provide and add oxidizing biocide as needed based on water usage. Legionella sampling must be taken and reported to engineering for (4) cooling towers on a quarterly basis and within 7 days of tower start-up. Annual cleaning and disinfection of (4) cooling towers.
BOILER PLANT
Provide continuous monitoring using cellular/cloud-based water treatment technology. All chemicals used need to be in solid form. Provide and add scale and corrosion inhibitor as needed based on water usage. Provide and add amines on a continuous feed. Provide test kits and training of onsite boiler operators. 3. CLOSED LOOP SYSTEMS
Treat 35 total hot and chilled water closed loops. Provide and add solid scale and corrosion inhibitor as needed based on quarterly testing.
Post Secondary Disinfection Services Monochloramine
Provide daily Ohio Environmental Protection Agency (OEPA) Water Supply Operator or Utility Worker to meet Class I minimum staffing requirements (including Holidays and weekends) Provide equipment, replacement parts, licensing, OEPA permits, chemicals, and consumables needed to operate Monochloramine system for (15) units. Complete forms and reports as required by OEPA. Remediate any areas that test positive for legionella during quarterly testing. Take and report to OEPA annual Lead and Copper, Disinfection byproducts and monthly Nitrite/Nitrate samples.
Ice Machine Services
Provide semi-annual cleaning and disinfection service on 45 ice machines. Provide and change (45) 0.2-micron bacteria filters semi-annually Provide reports and certification of semi-annual cleaning and disinfection service.
RO and Water Softener Services
Sterile Processing System
Provide monthly preventative maintenance service to Reverse Osmosis/Deionized (RO/DI) system. Change RO prefilter cartridge monthly Provide carbon exchange tank semiannually. Provide DI tank exchange as needed (based on water usage) for (6) DI tanks. Change (5) post DI 5-micron filter cartridges quarterly. Change (5) post Ultra Violet (UV) .2-micron filter cartridges quarterly. Change UV lamps annually Change storage tank vent filter annually. Take and report water samples as outlined in ANSI/AAMI ST108:2023 Water for the processing of medical devices. Endotoxin 60 samples yearly, HPC bacteria 36 samples yearly and 4 AAMI testing samples yearly.
Water Softener Services
Provide monthly preventative maintenance service to (6) water softeners Inspect, test water hardness, note all data, and submit reports monthly. Perform repairs as needed. Recommend upgrades to equipment as needed. Provide salt for softeners (Steam Plant not included).
B330-2B100 RO System
Provide monthly preventative maintenance service to RO system Inspect equipment, document equipment readings, supply a report on equipment to Include any recommended repairs. Change RO prefilter cartridge monthly. Annual Replacement of RO Membranes

Hemodialysis and Lab Purification Equipment Preventative Maintenance
Monthly Preventative Maintenance Service visits where all operational conditions are all logged and evaluated. Chemical disinfection of reverse osmosis system and ozone disinfect the water system distribution loop monthly during non-operating hours. Draw monthly Bacteria and Endotoxin LAL samples from RO Product, Pre and Post dialysis loop. Sample for AAMI ST108 contaminants. Utility water HPC 64 samples per year, Critical water Endotoxin 180 samples per year, Critical water HPC samples 180 per year, utility and critical water chemistry (hardness, pH, alkalinity, conductivity) 244 samples per year and utility and critical water Ionic 2 samples per year. Provide six (6) Model DI-451447E, Ultra-pure mix-bed deionized exchange tanks. DI Exchange tanks are installed in a primary/secondary arrangement. Provide three (6) Model CA-111447E carbon tanks installed in a primary/secondary arrangement. Includes making minor adjustments on an as needed basis during the service to ensure proper operation of the system. Laboratory - Provide two (2) DI-451447E Ultra-pure mix-bed deionized exchange tanks. DI Exchange tanks are installed in a primary/secondary arrangement. Provide Model 20-5013 carbon block per-filter to be replaced each time deionizer tank is exchanged. Additional filters will be billed at current price. Provide two (2) Model 20-3046 endotoxin post filter and replace every six (6) months. Provide replacement UV components
Monitoring of Ancillary Water Systems
Monitor operation and condition of campus wide steam condensate system. Recommend upgrades as needed. Monitor operation and condition of closed loop HVAC systems. Recommend upgrades as needed. Monitor operation and condition of campus water tower. Recommend upgrades and PM schedule. Provide requested guidance to Water Safety Committee (WSC) and review annual water safety plan for said committee.
6. Performance Monitoring: All work will be signed off by COR once completed.
7. Security Requirements: The C&A requirements do not apply, and a Security Accreditation Package is not required
8. Government-Furnished Equipment (GFE)/Government-Furnished Information (GFI). N/A
9. Other Pertinent Information or Special Considerations.
a. Identification of Possible Follow-on Work. N/A
b. Identification of Potential Conflicts of Interest (COI). None
c. Identification of Non-Disclosure Requirements. None
d. Packaging, Packing and Shipping Instructions. All packing slips and shipping labels will include the PO#. If there are equipment/supplies, a shipping confirmation should be provided to the COR and delivered to Dayton Veterans Affairs Medical Center 4100 W Third St Building 143, Dayton, OH 45428
e. Inspection and Acceptance Criteria: Sanipur holds the US patent on treatment of domestic hot water with monochloramine. VHA directive 1061 states that hot water and cold water must be treated independently. Other monochloramine vendors treat the hot water through the cold-water side which violates the directive. Therefore, Sanipur monochloramine machines must be used by the awardee. 10. Risk Control: Assumed by contractor 11. Place of Performance: VA Medical Center 4100 W. Third Street Dayton, Ohio 45428
12. Period of Performance: Base+4 beginning April 8th, 2026
13. Delivery Schedule: All work will be conducted during normal business hours, Monday Friday, 0800-1630 except on federal holidays

More opportunities from Department Of Veterans Affairs → 250-NETWORK Contract Office 10 (36C250)

Same awarding agency

NAICS: 335999
New
Federal
6130--Uninterruptible Power Supply (UPS) for East Indianapolis VA Clinic
Solicitation # 36C25027Q0037
Solicitation 36C25027Q0037 is a brand-name, firm-fixed-price request for quote issued by the Department of Veterans Affairs Network Contracting Office 10 for the procurement of four Medi-Products Silent Sentry Uninterruptible Power Supply (UPS) systems for the East Indianapolis VA Clinic. The requirement consists of three SSA2080V units and one SSA30180V unit, designed to provide critical electrical backup for pharmaceutical refrigerators with a target runtime of up to 88 hours. This procurement is set aside for small businesses under NAICS code 335999, and the award will be granted to the responsible quoter offering the lowest price. The government anticipates making the purchase order award in early December 2026. Technical specifications require that equipment be unused, not refurbished, and include the latest manufacturer software and hardware updates. The product manufacture date must not exceed 24 months prior to the award date, and included batteries must be manufactured within six months of the award date. Within three days of delivery, the contractor must provide electronic service manuals and warranty information to the VA HTM Department and the IOT&A contractor. Amendment 0001 clarified that a Security Accreditation Package and Section 508 documentation are not required, and that subcontracting plans are not applicable. Additionally, the amendment extended the response time to 60 days and specified that invoices will be processed after acceptance.
All Other Miscellaneous Electrical Equipment and Component Manufacturing

POSTED

2 days ago

DEADLINE

in 8 days
View Details
NAICS: 238290
New
Federal
J059-- FY27 NRM - VISN BASE Repair B35 Elevator - 538-26-203
Solicitation # 36C25027Q0112
The Department of Veterans Affairs, Network Contracting Office 10, is conducting market research via a Sources Sought notice to determine the acquisition strategy for elevator repairs at the Chillicothe VA Medical Center in Chillicothe, Ohio. The project involves the repair of the Building 35 P-2 elevator, specifically requiring the removal of the existing hydraulic plunger and the installation of a new jack assembly and PVC casing. The contractor will be responsible for site preparation, demolition, and providing all necessary labor, materials, and equipment. Key deliverables include the provision of maintenance and operating manuals in both hard copy and electronic formats. The work must be completed within 180 calendar days from the Notice to Proceed. Due to the medical environment, the contractor must implement strict infection control, dust prevention, and noise and vibration management, and must pre-coordinate any minor utility outages with the medical center. This procurement falls under NAICS code 238290 with a small business size standard of $22,000,000.00, and the government is evaluating the appropriateness of a set-aside for Service-Disabled Veteran-Owned Small Businesses (SDVOSB). Interested sources must submit written responses to Christopher Callihan by November 20, 2026; however, the government is not seeking pricing or formal offers at this time.
Other Building Equipment Contractors

POSTED

2 days ago

DEADLINE

in 5 days
View Details
NAICS: 561621
New
Federal
H312--Fire Alarm Maintenance Service Contract FY27 - NEW Base + Four - 583
Solicitation # 36C25027Q0009
Solicitation 36C25027Q0009 is a request for proposals from the Department of Veterans Affairs Network Contracting Office 10 for a fire alarm maintenance service contract at the Richard L. Roudebush VAMC in Indianapolis, Indiana, including the main hospital, campus out-buildings, and the Cold Springs Road remote site. This contract is a total set-aside for Service-Disabled Veteran-Owned Small Businesses (SDVOSB). The scope of work requires the contractor to provide inspection, testing, maintenance, and minor repairs for both electrical and mechanical components of fire alarm and suppression systems. The contract structure consists of a base year and four option years, with award based on price alone. Technical requirements mandate compliance with NFPA 72-2025, NFPA 25-2026, and Joint Commission standards. Key tasks include quarterly flow tests for the electric fire pump, while monthly no-flow tests are performed in-house by VA personnel. Personnel qualifications include a preference for NICET 3 certification, though NICET Level II may be accepted for certain inspections. Offerors must provide a mandatory Certificate of Compliance regarding limitations on subcontracting, ensuring no more than 50 percent of the work is performed by non-SDVOSB firms. All work must be conducted in accordance with strict VA cybersecurity and personnel vetting protocols, particularly given the critical nature of operating within an occupied healthcare facility.
Security Systems Services (except Locksmiths)

POSTED

3 days ago

DEADLINE

in about 22 hours
View Details
NAICS: 562211
New
Federal
F108--Radioactive Waste Removal & Disposal Services RFQ
Solicitation # 36C25027Q0108
The Department of Veterans Affairs, Network Contracting Office 10, is soliciting quotes for a firm-fixed-price contract to provide radioactive waste removal and disposal services for the Ann Arbor VA Medical Center in Michigan. The scope of work involves the removal, handling, packaging, and final disposition of liquid and solid low-level radioactive waste, including byproduct materials, patient treatment waste, scintillation vials, and liquid mixed waste. The contractor is responsible for providing all necessary packaging and must comply with Nuclear Regulatory Commission, Department of Transportation, and Environmental Protection Agency regulations. The anticipated period of performance begins January 11, 2027, and runs through January 10, 2032, consisting of a one-year base period and four optional one-year extensions. This procurement is a HUBZone Small Business set-aside under NAICS code 562211. To be eligible, contractors must maintain an active Radioactive Materials License granted by the NRC or an Agreement State, and all transporters must possess a commercial driver's license with a hazardous materials endorsement. Quotes must be submitted electronically to the contracting officer and include a signed SF1449 with a Unique Entity Identifier and a statement regarding the acceptance of terms and conditions. Evaluation will be based on technical capability and price, with the government evaluating the total price of the base requirement plus all option years. All offerors must be registered in the System for Award Management at the time of the offer.
Hazardous Waste Treatment and Disposal

POSTED

3 days ago

DEADLINE

in 16 days
View Details
NAICS: 561720
New
Federal
S201--VANIHCS Window Cleaning - Engineering Service Amendment to provide answers to contractor questions
Solicitation # 36C25027Q0016
Solicitation 36C25027Q0016 is a request for quotation issued by the Department of Veterans Affairs for exterior window cleaning engineering services at the Fort Wayne and Marion VA Medical Center campuses in Indiana. This procurement is set aside for Service-Disabled Veteran-Owned Small Businesses (SDVOSB) and falls under NAICS code 561720. The scope of work requires the contractor to provide all labor, equipment, and materials to perform exterior washing of windows, frames, sills, sashes, and door glass twice per year. The project includes a detailed inventory of approximately 2,014 windows at the Marion inner buildings, 241 windows at the Marion outer buildings, and 1,277 windows at the Fort Wayne campus. The contract structure consists of a base year starting December 1, 2026, with four subsequent option years, not to exceed a total duration of five years. Award will be granted to the lowest-priced, technically acceptable offeror, with evaluations based on total cost, past performance, and general standards of responsibility. Key requirements include OSHA and Fall Protection certification for all personnel, background investigations per VA security standards, and a mandatory quality control program. Offerors must be registered in the System for Award Management (SAM) and the VA financial system, and must certify compliance with subcontracting limitations, ensuring no more than 50 percent of the service value is paid to non-SDVOSB or non-VOSB firms.
Janitorial Services

POSTED

5 days ago

DEADLINE

in 4 days
View Details
NAICS: 484210
New
Federal
V301--539 - Fifth Floor Pharmacy Move Service Contract
Solicitation # 36C25027Q0106
The Cincinnati Veterans Administration Medical Center requires specialized relocation services to move its inpatient pharmacy from the fifth floor to the second floor, with the eighth floor serving as a backup depending on availability. This firm-fixed-price contract, with a projected period of performance from November 2026 to May 2027, involves the disassembly, packing, transport, and reassembly of medical equipment, workstations, and furniture. A critical component of the scope is the provision of controlled environment certification services for non-hazardous pharmacy IV hoods, including laminar flow bench certification, operational particle counts, air sampling, and smoke pattern digital recording. After a temporary period of two to four weeks, the contractor will be required to move all equipment back to its original location on the fifth floor. The contractor must provide all necessary labor, vehicles, and packing materials, including RAM-board for floor protection. Key requirements include the submission of a Certificate of Public Convenience and Necessity from the Ohio PUCO and liability insurance that covers the value of the relocated equipment and facility damages. Performance will be validated through a final walkthrough and functional inspection conducted by the COR and technical personnel within 72 business hours of the move. Security protocols strictly prohibit contractor access to the VA network or any patient and employee PII/PHI. The project requires a dedicated team including a site supervisor, movers, truck drivers, and room certification testers.
Used Household and Office Goods Moving

POSTED

5 days ago

DEADLINE

in 9 days
View Details

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS