Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, November 11 at 2:00 PM ET

Register Free →

This Combined Synopsis/Solicitation opportunity from Department Of Health And Human Services was posted on May 29, 2023. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

Hospital beds

Closed
IHS1472633Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

General Info

NAICS

339113 - Surgical Appliance and Supplies Manufacturing

Place of Performance

Phoenix, AZ, 85016, USA

Set-Aside

BICiv

Documents

2

Attachment 00001 - Hospital Beds and Accessories

PDF, High priority: read this firstspecifications
High

IHS1472633 - Hospital beds and accessories (PIMC)

PDF, High priority: read this firstrfq
High

AI Contract Breakdown

Uniform Contract Format

Contract not broken down yet

CLEATUS splits the solicitation into Uniform Contract Format (UCF) sections: scope, pricing, deliverables, and evaluation criteria.

Timeline

PhaseClosed
Posted

Combined Synopsis

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Health And Human Services → Phoenix Area Indian Health Svc
Contacts1 person available
OfficePHOENIX, AZ, 85004, USA
Office AddressPHOENIX, AZ, 85004, USA
Contacts

Full Description

Show more
Hospital Beds and Accessories Brand name or alternate must be equal or exceed requested specifications 16 each - Medsurg Centrella Smart Bed 16 each - CNT-PAK255 CNT-255 Bed 16 each - CNT-NUL Nurse Call UTV Lighting 16 each - CNT-AR Accessory Outlet 16 each - CNT-PRO40 PRO Surface for 40" Frame 16 each - CNT-40 40" Frame Width 16 each - CNT-SV SafeView with IllumiGuide 16 each - CNT-2LCD Second LCD Touchscreen 16 each - CNT-PH Ergonomic Push Handles 2 each - Medsurg Compella Bariatric Bed 2 each - CBB-BASE Compella Base Frame 2 each - CBB-CLRT Continuous Lateral Rotation 2 each - CBB-ID IntellidriveXL with 6" Casters 2 each - CBB-PPM PPM 3 Level Adv Bed Exit Alarm 6 each - Medsurg Centrella Smart Bed 6 each - CNT-PAK355 CNT-355 Bed 6 each - CNT-NUL Nurse Call UTV Lighting 6 each - CNT-ID Intellidrive Transport 6 each - CNT-AR Accessory Outlet 6 each - CNT-40 40 Frame width 6 each - CNT-MAX36U 36" to 40" MAX Surface Upgrade 6 each - CNT-CLR Continuous Lateral Rotation 9 each - ICU Centrella Smart Bed (CNT-BASE) 9 each - CNT-PAK355 CNT-355 Bed 9 each - CNT-NUL Nurse Call UTV Lighting 9 each - CNT-ID Intellidrive Transport 9 each - CNT-AR Accessory Outlet 9 each - CNT-40 40" Frame Width 9 each - CNT-MAX36U 36" to 40" MAX Surface Upgrade 9 each - CNT-CLR Continuous Lateral Rotation 2 each - Progressa ICU Bed System (Pro-base Progressa Base Frame) 2 each - PRO-T Advanced Microclimate Surface 2 each - PRO-RT Rotations 2 each - PRO-PV Percussion Vibration 2 each - PRO-CE Chair Egress Position 2 each - PRO-PMMS Patient Migration Mgmt 2 each - PRO-NUL Nurse Call Univ TV Lighting 2 each - PRO-ID Intellidrive with 6" Casters 2 each - PRO-LH Permanent IV Pole Left Side

More opportunities from Department Of Health And Human Services → Phoenix Area Indian Health Svc

Same awarding agency

NAICS: 238220
New
Federal
Cooling Tower Refurbishment - Three (3) Cells
Solicitation # ACQ-IHS-2027-U-00021
The Phoenix Area Indian Health Service is seeking a contractor for the refurbishment of three EVAPCO Model ESWB 9-34K12 cooling tower cells at the Fort Yuma Health Center in Winterhaven, California. The scope of work involves the replacement of fill media, fill supports, and eliminator assemblies across all three cells to restore reliable cooling performance. To ensure the medical facility remains operational, the contractor must service the cells sequentially, one at a time. The project requires the use of Original Equipment Manufacturer (OEM) parts or approved equivalents and must be completed within thirty calendar days from the date of award or notice to proceed. This opportunity is set aside for Indian Small Business Economic Enterprises (ISBEE) under the Buy Indian Act. Qualified offerors must provide a capability statement, manufacturer authorization, and evidence of completing at least three similar projects within the last five years, specifically within occupied healthcare environments. Contractors must adhere to strict safety and operational protocols, including lockout/tagout procedures, infection control risk assessment (ICRA) measures, and compliance with Fort Yuma Quechan Indian Tribe Tribal Employment Rights Office (TERO) requirements. Final acceptance is contingent upon a functional completion check and the correction of any deficiencies, with a minimum one-year warranty required for all labor and materials.
Plumbing, Heating, and Air-Conditioning Contractors

POSTED

4 days ago

DEADLINE

in 3 days
View Details

Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS