Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, September 2 at 2:00 PM EDT

Register Free →

This Solicitation opportunity from Government of Canada was posted on July 22, 2025. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

HVAC & Refridgeration Services

Closed
50400-25-4991224International

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

General Info

Agency

Government of Canada → Correctional Service of CanadaView Agency

NAICS

N/A

Place of Performance

*Saskatoon, CAN

Set-Aside

NONE

Documents

(1)

2025-06-11-10-38-npp-english.pdf

PDF

AI Contract Breakdown

Uniform Contract Format

What is UCF?

Uniform Contract Format (UCF) uses AI to break down any contract into standardized sections—scope, pricing, deliverables, and evaluation criteria.

Timeline

PhaseClosed
Posted

Solicitation

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Start your free trial to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyGovernment of Canada → Correctional Service of Canada
Contacts1 person available
OfficeN/A
Organization / Agency
Government of Canada → Correctional Service of Canada
View Agency Profile
Office AddressN/A
Contacts
Katherine BoothPoint of Contact

Full Description

Show more
• The contractor must provide all equipment, labour, and supervision necessary to service the heating units/systems listed in Annex A1. • The contractor must supply licensed journeyman/technician/mechanics as necessary for the required inspection, service, repair and/or replace all HVAC and Refrigeration equipment as listed in Annex A or install of new equipment as identified by the Project Authority or Designate. Licensing must be applicable to the province of Saskatchewan. Copies of licensing may be requested for personnel going on site. • The required inspection includes annual leak test, service logs, decommissioning, and any other related duties to ensure RPC remains compliant with Federal Halocarbon Regulations and associated reports as per the Federal Halocarbon regulations and Correctional service of Canada’s policy on the management of Halocarbon’s CD 318-4. (see Annex A4). Such work must be performed in accordance with applicable legislation and regulations. Copies of required certification may be requested. The documentation of service/maintenance must be provided to the project authority within four (4) weeks of completion. • The contractor must carry out a total preventative maintenance check by inspecting, servicing, repairing and/or replacing components as required. (This will be accomplished with prior approval of the project authority). The 72 units described in Annex A1 will be serviced in the appropriate seasons as named in Annex A1. See Annex A2 spring (cooling season) and Annex A3 fall (heating season) for a detailed check list. Spring checks must be completed in the month of April. Fall checks must be completed in the month of October. Based on the spring and fall checks, contractor will supply a recommended repair list to the project authority for review and approval. Once approved, repairs will be completed at the applicable technician rate and parts/material cost. • The Contractor must replace all filters on the units described in the Annex A1 – A3 during the months of, February, April, June, July, August, September, October and December, unless otherwise specified by the Project Authority. • The contractor must provide qualified technician(s) as required (24-hour service). Response time must be within two hours for emergency repairs as determined by the Project Authority or Designate. • The Contractor's representative/technician must have numbered work orders which will be signed by the Project Authority or designate when the work has been completed. A copy of the work order is to be left with the Project authority or designate. The contractor will also supply any/all additional reports required, to the project authority based on existing legislation. i.e., Federal Halocarbon regulations. • Contractor must separately invoice any work and/or repairs done to units 63 – 67 under Kitchen Refrigeration Equipment in Annex A1 of the Statement of Work. These invoices will be addressed to the Chief, Food Services or Designate at the Regional Psychiatric Centre • Parts and material, must be supplied by the Contractor, at the agreed upon rate as per the basis of payment, pending approval by the Project Authority • All parts and material must meet all specifications as recommended by the manufacturer and determined by the Contractor. • Unless stipulated otherwise, filter media must be cardboard, disposable, pleated type construction. Quality must be minimum MERV 13. AAF MEGApleat M13 or equivalent filter media. • The contractor must have the required equipment and personnel to provide this service immediately after contract award.

More opportunities from Government of Canada → Correctional Service of Canada

Same awarding agency

NAICS: 621111
International
Primary Care Physician Services at Nova Institution for Women
Solicitation # 21250-25-4984610B
The Correctional Service of Canada is seeking a Primary Care Physician to provide integrated, trauma-informed, and culturally appropriate medical services at the Nova Institution for Women in Truro, Nova Scotia. The successful contractor will collaborate with an interdisciplinary healthcare team to deliver patient-centered care and participate in the coordination of essential health services. This procurement is open exclusively to Canadian suppliers and is not subject to any trade agreements or Indigenous set-asides. The contract is awarded to the compliant bid with the highest technical score based on a rated criteria system totaling 90 points, with a specific tie-breaking hierarchy prioritizing criteria R3, R2, R4, and R8. The contract has a fixed duration of 36 months from the date of award, with an estimated total value ranging from 194,472 to 201,972 dollars. Payment is based on a fixed hourly rate of 438.00 dollars for both clinical work and quality improvement services. Due to the secure nature of the environment, the contractor must possess a valid Designated Organization Screening and all personnel must hold Reliability Status clearance. Bidders must certify compliance with the Ineligibility and Suspension Policy and the Federal Contractors Program. All deliverables, including health service data and reporting on public health indicators, must adhere to the Contract Security Manual and applicable federal and provincial privacy laws.
Offices of Physicians (except Mental Health Specialists)

POSTED

8 days ago

DEADLINE

in 16 days
View Details