HVAC Building Automation Controls Service Contract
Contract Overview
Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.
AI Contract Overview
The Defense Threat Reduction Agency (DTRA) has awarded contract HDTRA226R0020 to Automated Control Systems, Inc. (ACSI) for the maintenance and lifecycle management of the air-gapped Distech Building Automation Control System at DTRA Bldg. 20336, Kirtland AFB, New Mexico. This sole-source acquisition, valued at $196,438.01 over a five-year period consisting of a one-year base and four option years, is justified under FAR 13.106-1(b)(1) due to ACSI's status as the exclusive manufacturer-authorized Local Distributor Partner with the required Distech and Niagara 4 certifications. The scope is strictly limited to systems integration, administration, and hardware replacement for the controls, databases, and communication network, explicitly excluding physical mechanical HVAC plant equipment. Critical performance requirements include a maximum system downtime of 24 hours and an emergency on-site response time of one to two hours. Due to the mission-critical and air-gapped nature of the system, all manual software patching requires prior approval from the DTRA IT Security (ISSM). As a final deliverable, the contractor must provide a Site-Specific Configuration and Turnover Package containing as-built logic, configuration files, and administrative credentials to ensure future competition and system continuity.
General Info
Agency
Contract Value
$196,438.01NAICS
Place of Performance
0, NM, 87117, USASet-Aside
Awardee
Award Issued Date
Timeline
Organization & Contact Information
Full Description
This acquisition covers critical preventative maintenance, emergency on-site repair, and proprietary software lifecycle management for the standalone, air-gapped Distech Building Automation Control System serving DTRA Bldg. The scope is strictly limited to the building automation controls, databases, and communication network; it explicitly excludes the repair of physical mechanical HVAC plant equipment (e.g., chillers, boilers, AHUs), which is handled under the base maintenance contract. The requirement mandates a 24-hour maximum system downtime, immediate on-site response times (1 to 2 hours), and strict DTRA IT Security (ISSM) pre-approval for all manual software patching.
Similar Contracts
Same NAICS industry code
More opportunities from Department Of Defense → Defense Threat Reduction Agency
Same awarding agency