Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, July 8 at 2:00 PM EDT

Register Free →

This Solicitation opportunity from Government of Canada was posted on May 11, 2026. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

Invitation to Tender - Salmon Arm RCMP HVAC Upgrades

Closed
BC229216Canada

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

AI Contract Overview

Show more

This project involves comprehensive HVAC upgrades at the Salmon Arm RCMP facility under a federal solicitation with strict clearance requirements, mandating all personnel hold FA-03 clearances. The scope includes the complete demolition of existing AHU-1, AHU-2, EF-1, and EF-2 units along with all associated accessories, valves, fittings, wiring, and thermostats, as outlined in the drawings. New rooftop AHUs will be installed with manufacturer-recommended spring curbs, and ductwork will be selectively reused or newly installed: AHU-1 will reuse existing supply and return ducts, AHU-2 will reuse the supply duct but require a new return section to connect to existing exhaust, and AHU-3 will feature entirely new supply ductwork and a new return riser connected to the existing change room exhaust. New thermostats will be installed in compliant locations according to zoning needs, and all new AHUs must be fully integrated into the existing DDC control system. Additionally, new VFD pumps and pressure differential sensors will be provided to enhance system efficiency and control. The solicitation, issued by the Government of Canada through the City of Salmon Arm, has a response deadline of June 11, 2026, and is managed by Contracting Authority Darin Gerow.

General Info

HVAC upgrades at Salmon Arm RCMP with FA-03 clearance required, new rooftop AHUs, ductwork modifications, DDC integration, VFD pumps, June 11, 2026 deadline.

Agency

Government of Canada → City of Salmon Arm

NAICS

238220 - Plumbing, Heating, and Air-Conditioning Contractors View NAICS

Place of Performance

CAN

Set-Aside

NONE

Documents

(0)

No documents available

AI Contract Breakdown

Uniform Contract Format

No contract breakdown available.

Cannot generate Contract Breakdown because no documents were found from this contract's source.

Timeline

PhaseClosed
Posted

Solicitation

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Start your free trial to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyGovernment of Canada → City of Salmon Arm
Contacts1 person available
OfficeN/A
Organization / Agency
Government of Canada → City of Salmon Arm
Office AddressN/A
Contacts
Darin GerowContracting Authority

Full Description

Show more
THIS PROJECT IS SUBJECT TO SPECIAL CLEARANCE REQUIREMENTS. ALL PERSONNEL SHALL HAVEFA-03 CLEARANCES. REFER TO APPENDIX A.SCOPE OF WORKDEMOLISH:AHU-1, AHU-2, EF-1, EF-2DUCTING AS PER DRAWINGS.MAIN HEATING PUMPS.ALL AFFECTED ACCESSORIES, VALVES, FITTINGS, WIRING, THERMOSTATS, ETC.PROVIDE:NEW ROOFTOP AHUS COMPLETE WITH MANUFACTURER RECOMMENDED SPRING CURBS.AHU-1: REUSE EXISTING SUPPLY AND RETURN DUCTWORK.AHU-2: REUSE EXISTING SUPPLY DUCTWORK; PROVIDE NEW RETURN DUCT SECTION TOCONNECT EXISTING EXHAUST DUCTING.AHU-3: PROVIDE NEW SUPPLY DUCTWORK; PROVIDE NEW RETURN RISER AND CONNECT TOEXISTING CHANGEROOM EXHAUST DUCTWORK.PROVIDE NEW THERMOSTATS IN ACCEPTABLE LOCATIONS PER ZONING REQUIREMENTS.INTEGRATE NEW AHUS INTO EXISTING DDC SYSTEM.NEW VFD PUMPS WITH NEW PRESSURE DIFFERENTIAL SENSORS..