J -- Preventive Maintenance

Awarded
N65236-09-Q-3221Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

General Info

Contract Value

$10,801.5

NAICS

811211 - Consumer Electronics Repair and Maintenance

Place of Performance

SC

Set-Aside

NONE

Award Issued Date

Documents

0

No documents available

Documents will appear here when they are available.

AI Contract Breakdown

Uniform Contract Format

No documents to break down

The breakdown needs solicitation documents. None were found from this contract's source.

Timeline

PhaseAwarded
Posted

Presolicitation

Awarded

Contract was awarded

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Defense → Niwc Atlantic
ContactsNo contacts available
OfficeNORTH CHARLESTON, SC, 29419-9022, USA
Office AddressNORTH CHARLESTON, SC, 29419-9022, USA
ContactsNo contact information available

Full Description

Show more
This is a sole source announcement. The Government intends to award thisrequirement on a sole source basis to Lee Technologies for they are the only local distributor for UPS system mfg. by Schneider Electric. Statement of Work is below: STATEMENT OF WORK DATE: START: COMPLETE: SHORT TITLE: Naval Station Norfolk, Gate UPS Systems Service Contract 1. PLACE(S) AND DATES OF PERFORMANCE a. Gates 2, 3A, Q1, and 5 at Naval Station Norfolk b. SPAWAR, St. Julian's Creek Annex, Portsmouth, Va c. Contractor's facilities 2. REFERENCES a. SPAWARSYSCEN Shore Installation Process Handbook V2.3 b. Applicable Antenna/Equipment Technical Manuals and Documentation c. Applicable facility drawings d. DOD 5220.22M, Industrial Security Manual for Safeguarding Classified Information e. MIL-STD-188-124B N3, Grounding, Bonding, and Shielding for Electronic Common Long Haul/Tactical Communications Systems including Ground based Communications Electronics Facilities and Equipments f. NFPA 70, National Electrical Code; current addition g. MIL-HDBK-419A, Vol. 2 Grounding, Bonding, and Shielding for Electronic Equipments and Facilities h. Occupational Safety and Health Act (OSHA), Code of Federal Regulations Title 29 i. Occupational Safety and Health Act (OSHA), Code of Federal Regulations Title 40 3. SPECIFICATIONS a. MIL-STD-188-124B N3, Grounding, Bonding, and Shielding for Electronic Common Long Haul/Tactical Communications Systems including Ground based Communications Electronics Facilities and Equipments b. NFPA 70, National Electrical Code; current edition c. MIL-HDBK-419A, Vol. 2, Grounding, Bonding, and Shielding for Electronic Equipments and Facilities d. ANSI/TIA/EIA-568B; Commercial Building Telecommunications Cabling Standard e. ANSI/TIA/EIA-569A, Commercial Building Standard for Telecommunications Pathways and Spaces f. ANSI/TIA/EIA-606, Administrative Standard for the Telecommunications Infrastructure of Commercial Buildings 4. SECURITY REQUIREMENTS No clearance level is required for this work; however, the contractor shall provide technicians which have passed a federal background check. 5. DESCRIPTION OF WORK The contractor should provide an annual onsite service contract tailored for each Uninterruptable Power Supply (UPS) System located at gates 2, 3A, Q1, and 5. Each system listed in section 5.2 shall be provided the following services. 5.1 Service Details 1. Provide an onsite 24 hour, seven days a week emergency service plan. Response time should be four hours or less. 2. Service should include all parts and labor excluding capacitors and batteries. 3. Provide factory technical support during normal business hours including call management. 4. Provide one major preventative maintenance tune up. 5. Provide one minor preventative maintenance tune up. 6. Provide two six month battery maintenances. 5.2 System Information 1. Gate 2: M/N: 50 kva Comet S/N: B04-11890 2. Gate 3A: M/N: 50 kva Comet S/N: B04-11888 3. Gate Q1: M/N: 20 kva Galaxy S/N: A04-12006 4. Gate 5: M/N: 225 kva Galaxy S/N: TBD 6. ELECTRONIC AND INFORMATION TECHNOLOGY (EIT) SECTION 508 ACCESSIBILITY Determination of Applicability This requirement has been reviewed and it is not for EIT. 7. GOVERNMENT FURNISHED INFORMATION Not Applicable 8. GOVERNMENT FURNISHED MATERIAL Not Applicable 9. GOVERNMENT FURNISHED EQUIPMENT Not Applicable 10. CONTRACTOR FURNISHED EQUIPMENT As needed. 11. CONTRACTOR FURNISHED MATERIAL As needed.

More opportunities from Department Of Defense → Niwc Atlantic

Same awarding agency

NAICS: 541380
New
Federal
Market Survey for E3 Services Support of C6ISR Systems
Solicitation # N65236-26-RFPREQ-LSUBP00080-0002
The Naval Information Warfare Center, Atlantic (NIWC Atlantic) is conducting a market survey for a contract to provide Electromagnetic Environmental Effects (E3) Test, Evaluation, Training, and Range Services in support of C6ISR Systems. The anticipated scope of work includes testing electromagnetic radiation and spectrum effects, supporting the TEMPEST Program and Protected Distribution Systems inspections, and performing environmental testing such as shock, vibration, altitude, and temperature/humidity. The effort is aligned with the Navy's Information Dominance Roadmap for Electromagnetic Spectrum Usage and the Secretary of Defense's Electromagnetic Spectrum Superiority Strategy. The primary place of performance is at NIWC Atlantic, with potential travel to various CONUS and OCONUS locations. The government anticipates a five-year ordering period with an estimated value between 10 million and 50 million dollars, utilizing approximately 15 full-time equivalents per year. The contract is expected to be a firm-fixed price type for labor and calibration, with cost-reimbursement for materials and travel. Key requirements include adherence to IEEE 149 antenna test procedures, strict cybersecurity compliance, and the use of the DoD Wide Area Work Flow for invoicing. Contractors must maintain appropriate facilities, possess PKI client-side authentication capabilities, and comply with DFARS regulations regarding counterfeit electronic parts and government property management. Responses to this market survey are due by November 4, 2026.
Testing Laboratories and Services

POSTED

1 day ago

DEADLINE

in 6 days
View Details

Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS