Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, November 11 at 2:00 PM ET

Register Free →

This Government Contract opportunity from Department Of Veterans Affairs was posted on April 3, 2024. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

J041--Base +4 OY | WNY BUF/BAT Chiller & Boiler Water Treatment

Awarded
36C24224Q0402Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 811310
New
Kubota M8200 Clutch Replacement
Solicitation # kubota-m8200-clutch-replacement
Management & Training Corporation (MTC) is soliciting bids for the clutch replacement of a Kubota M8200 tractor with front wheel assist, no cab or loader, located at the Earle C. Clements Job Corps Center in Morganfield, Kentucky. The scope of work requires the contractor to provide all transportation, labor, supervision, tools, and new manufacturer-specified parts to diagnose and repair the clutch assembly and power take-off (PTO) system. Key technical requirements include disassembling tractor components, replacing friction discs, bearings, oil seals, and O-rings, resurfacing the flywheel, and replacing hydraulic pipes and filters as necessary. The project is complete once the Facility Maintenance Department verifies proper clutch engagement and PTO operation under load. This is a small business set-aside opportunity under NAICS code 811310, open to various SBA-certified categories including VOSB, SDVOSB, WOSB, and HUBZone businesses. Proposals must be submitted via email to Angie Mahoney by November 3, 2026, and must include a lump sum bid sheet, a completed supplier packet with a W-9 and self-certification form, and proof of insurance. Award will be based on best value, considering the contractor's qualifications, experience, and the itemized cost breakdown. The contract is subject to Federal Acquisition Regulation (FAR) clauses regarding the Buy American Act, combating trafficking in persons, and Service Contract Labor Standards per Wage Determination No. 2015-4687 Revision 31 for Kentucky.
Earle C. Clements Job Corps Center

POSTED

about 5 hours ago

DEADLINE

in 5 days
NAICS: 811310
New
SLED
**Certified SB/DVBE Only** IFPQ Boiler Inspection, Maintenance, Repair, Testing, and Reporting in Los Angeles County
Solicitation # 07A6539
The California Department of Transportation (Caltrans) is soliciting price quotes for an Invitation for Price Quote (IFPQ 07A6539) to provide comprehensive boiler inspection, maintenance, repair, testing, and reporting services at the District 7 Office facility in Los Angeles, California. The scope of work includes annual and quarterly preventative maintenance for three Unilux water tube boilers and six boiler pumps, ensuring compliance with manufacturer standards, ASME Code, OSHA requirements, and South Coast Air Quality Management District standards. This is a set-aside solicitation exclusively for certified Small Business (SB), Microbusiness (MB), or Disabled Veteran Business Enterprise (DVBE) entities. The contract will be awarded to the responsible bidder offering the lowest price quote who meets all specifications. Key operational requirements include a 48-hour response time for routine service requests and a strict prohibition on subcontracting any portion of the work. The contractor must adhere to State General Prevailing Wage Rates for Los Angeles County and provide a payment bond for any service request exceeding 25,000 dollars. Required submission documents include a Price Quote Proposal, Bidder Certification Sheet, Non-Collusion Declaration, and certifications for California Civil Rights Laws and the Darfur Contracting Act. Invoicing is conducted monthly in arrears and must be accompanied by certified payroll records and DVBE utilization reports. The agreement is subject to a budget contingency clause, meaning it is enforceable only if sufficient funds are provided by the California State Legislature or the United States Government.
California Department of Transportation

POSTED

about 6 hours ago

DEADLINE

in 15 days
NAICS: 811310
New
SLED
RFP 07-135 Roseville Electric Utility – Air Compressor Maintenance
Solicitation # 07-135
The City of Roseville is soliciting proposals under RFP 07-135 for a consultant to provide comprehensive scheduled preventive and corrective maintenance for air compressors and auxiliary systems, including Ingersoll Rand equipment. The services will be performed at the Roseville Energy Park and Sunset Energy Center in California. The selected consultant will be responsible for providing all necessary labor, technical expertise, specialized tooling, and materials. This is a prevailing wage project with an initial contract duration of five years, estimated to commence in April or May. Proposals must be submitted by December 16, 2026, via email to the City Clerk or through physical delivery in a sealed container with the required Attachment H label. The award will be based on a formal evaluation panel process considering the firm's experience and qualifications (25 points), the proposed project plan (35 points), and cost (40 points), with potential interviews for top candidates. Requirements for the successful bidder include obtaining a City of Roseville business license, providing 100% faithful performance and labor and materials bonds, and maintaining specific insurance policies. Consultants must also disclose any conflicts of interest and adhere to the Levine Act regarding political contributions.
City of Roseville

POSTED

about 11 hours ago

DEADLINE

in about 2 months

AI Contract Overview

Show more

Contract 36C24224P0921 was awarded by the Department of Veterans Affairs Network Contract Office 02 to Nalco Company LLC for chiller and boiler water treatment services at the Buffalo and Batavia VAMC facilities in New York. The project, identified under solicitation 36C24224Q0402 and NAICS code 811310, involves a base period plus four option years of service. The contract was officially issued on April 2, 2024, with the place of performance located in Buffalo, New York. While the award notice lists an initial amount of 37,908.00 dollars, the total estimated award value for the full term of the contract is 229,690.70 dollars. Daniel Zielinski serves as the primary contracting officer for this engagement.

General Info

Contract Value

$131,432.16

NAICS

811310 - Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance

Place of Performance

Buffalo, NY, 14215, USA

Set-Aside

NONE

Award Issued Date

Documents

1

Award Notice - 36C24224P0921 - Buff and Batavia Chiller and Water Treatment

PDF, Low priorityaward
Low

AI Contract Breakdown

Uniform Contract Format

Contract not broken down yet

CLEATUS splits the solicitation into Uniform Contract Format (UCF) sections: scope, pricing, deliverables, and evaluation criteria.

Timeline

2 updates
PhaseAwarded
Posted

Presolicitation

Type Changed

Presolicitation → Solicitation

Deadline changed

Response deadline changed from Mar 20, 2024 to Mar 18, 2024.

Notice updated

Response deadline changed from Mar 18, 2024 to Mar 22, 2024. The notice description changed.

Awarded

Contract was awarded

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Veterans Affairs → 242-NETWORK Contract Office 02 (36C242)
Contacts1 person available
OfficeALBANY, NY, 12208, USA
Office AddressALBANY, NY, 12208, USA
Contacts
Daniel ZielinskiContracting Officer

Full Description

Show more
This amendment answers the following vendor questions after the site visit on 03/13/2024 and makes changes to the SOW. A revised SOW is provided in the attachments. All additional questions shall be submitted by 03/20/2024 at 10:00am EST. The solicitation quote submission deadline has been moved to 03/22/2024 at 10:00 am EST. Vendor Questions Question: It sounded like the new tower system and the tower system that is to remain operational in Bldg 20 will both be operational year-round. Is that correct? Or is one or both of these systems being drained for the winter? (In Buffalo, that is). Answer: Building 20, cooling tower 3 utilizes a remote sump for a walk-in cooler that will remain filled all winter, the tower pumps only come on at 50 degrees and above. We hope to keep at least one tower full for the building 1 system for usage on the occasional warm winter day when cooling is necessary for our critical areas. Question: I see in part 2g of section B.2.6 that it states that a third-party needs to document makeup water quality, system water chemistry, and corrosion byproducts. Does that mean that we need to send samples out to a third-party lab every month, or is your water treatment provider considered the third party? Answer: A water sample must be taken from the cooling tower system at least one time each month that the unit is operational and sent to an environmental-accredited laboratory for HPC testing. (ES-2019-001, pg 15). Question: I.e Boiler Chemical. Can replacement porta bins be brought directly into boiler room and pumped into the bins in the containment or does the boiler chemical have to be pumped in from outside? Answer: The boiler chemicals can be brought in from the loading dock, down the elevator and into the boiler plant main floor. The sulfite is on the mezzanine level and is currently pumped in from outside the boiler plant by the grounds offloading dike thru a permanent hose that is mounted inside the man door. Question: For the Buffalo plant, can we get steam production by season?....and which boilers are in use by season? Answer: Boilers 1,2,3 are predominantly used during the cold months, and boiler 4 is our summer boiler but does run during cold weather to supplement sometimes. All four boilers are kept in hot standby yearlong and are fired regularly to keep warm when not the main running boiler. See attached SOW for steam produced per month. Question: Do you track the water usage (makeup) for the tower systems? We d like to know how much is typically used in a year for both Buffalo and Batavia. Answer: The are currently not being tracked by the VA. Question: What is the total volume of water in the tower systems? Especially the new tower system in Buffalo. Answer: Approximately 44,000 gallons. Question: Could we get some clarification on your expectations for tower cleanings? Answer: Semi-annual preventive maintenance (PM) as part of the start-up/shutdown process, including Cleaning of the sump and fill: the system must be disinfected, cleaned and re-disinfected immediately prior to initial startup following commissioning or any shutdown period of greater than one month or at intervals not exceeding 6 months (ES-2019-001, pg 14). Question: Will we be given an opportunity to present our findings / recommendations in person? Answer: Written proposal only. Question: One question I have is regarding the current chemical containment bins on site. Are all chemical containment bins part of this bid? Do any on site at either location need to be replaced as part of the bid? Answer: All equipment including containment be the contractor s responsibility to furnish, install, and maintain. Question: Do dip slides need to be sent to an environmentally accredited lab? Answer: Heterotrophic Plate Count (HPC): A water sample must be taken from the cooling tower system at least one time each month that the unit is operational and sent to an environmental-accredited laboratory for HPC testing. (ES-2019-001, pg 15) Question: It also looks like the spec is calling from remote wireless data monitoring for the towers (that is reasonable), but it also says that remote monitoring should be set up for the chilled water side of each tower system. I've never seen that done and am not sure what we would even monitor in a closed loop system. Can you provide any insight as to what you're looking for? Answer: This was a typo. See SOW edits below. SOW EDITS B.3.7.14.a shall now read the following: Remote monitoring is to be set up on the condenser. B.3.7.14.h has been added to read the following: Monitoring system shall be able to effectively communicate with our building management system. B.3.12.2 Guiding Documents, shall now read: The following documents are applicable to this Scope of Work (SOW) to the extent specified herein. While every effort has been made to ensure the completeness of this list, document users are cautioned that they must meet all specified requirements of applicable documents, whether they are listed here or not. a. VHA Master Construction Specifications: i. 23 08 00 Commissioning of HVAC Systems ii. 23 21 13 Hydronic Piping iii. 23 21 23 Hydronic Pumps iv. 23 25 00 HVAC Water Treatment VHA DIRECTIVE 1061(1) VHA Engineering Standard ES-2019-001 The above directives, guides, handbooks, and drawings form a part of this document to the extent specified herein. Unless otherwise specified, the latest revisions available shall be used. Copies of related Department of Veterans Affairs directives, guides, and handbooks are available from the Office of Construction and Facilities Management website: http://www.cfm.va.gov/til/index.asp ASHRAE 188-2018 NATIONAL FIRE PROTECTION ASSOCIATION (NFPA) Should a conflict exist between VA requirements and nationally recognized codes and standards, the conflict must be brought to the attention of the VA. The resolution of conflict must be made by the VA Authority Having Jurisdiction (AHJ).

More opportunities from Department Of Veterans Affairs → 242-NETWORK Contract Office 02 (36C242)

Same awarding agency

Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS