This Sources Sought opportunity from Department Of Veterans Affairs was posted on July 1, 2024. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

J047--Request For Information Boiler Maintenance at York Campus

Closed
36C24924Q0332Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 238220
New
WOJC - Multi-Building Plumbing Leak Repair Project
Solicitation # WOJC – Multi-Building Plumbing Leak Repair Project
Education and Training Resources is seeking quotes for a subcontracting opportunity to perform multi-building plumbing leak repairs at the Westover Job Corps Center in Chicopee, Massachusetts. The scope of work includes replacing leaking shower P-trap drain pipes in Rooms 123 and 213, repairing a cracked drain pipe in the pipe chase of Room 216, and replacing approximately ten linear feet of leaking heat pipe sections in both the Administration Building and King Hall. All work must conform to the Massachusetts State Plumbing Code and International Plumbing Code, utilizing new commercial-quality materials suitable for hydronic heating service. The contractor is responsible for removing all debris and repairing any facility damage caused during performance at no additional cost. Interested bidders must submit a detailed quote by October 30, 2026, including a comprehensive cost breakdown of labor and materials, a proposed service schedule, and a bid validity period of at least 60 days. Required documentation includes a current SAM.gov UEI number, active registration, Massachusetts licensing, a W-9, a signed ETR Vendor Acknowledgement Form, and certificates of insurance. This is an SBA set-aside opportunity for various small business categories. Award selection is not based solely on the lowest price; ETR will evaluate cost, qualifications, and administrative compliance. The project is subject to federal regulations, including the Davis-Bacon Act, Service Contract Act, and specific FAR clauses regarding anti-lobbying and debarment. Performance bonds are required for projects exceeding 35,000 dollars.
Westover Job Corps Center

POSTED

about 16 hours ago

DEADLINE

in 9 days
NAICS: 238220
New
MI 2026-14 Emergency Heating and Air Conditioning Services
Solicitation # MI 2026-14
Adams and Associates, Inc., contracting for the U.S. Department of Labor, is soliciting bids for emergency heating and air conditioning services at the Miami Job Corps Center in Florida. The period of performance runs from November 1, 2026, to October 31, 2027. The selected vendor will provide emergency HVAC repairs, with pricing required for non-emergency daytime services (8:00 am to 4:30 pm) as well as emergency, weekend, and holiday rates. As a federally funded facility, the Center is entitled to GSA pricing. Award decisions will be based on the most responsible bidder, considering cost, licensure, experience, and insurance capabilities. Eligible bidders must be small businesses or certified socioeconomic categories, including VOSB, SDVOSB, WOSB, and HUBZone. Mandatory requirements include a valid Unique Entity ID (UEI), active SAM.gov registration, and all necessary Florida state business and employee licenses. Vendors must maintain Workers Compensation, Automobile Liability, and Comprehensive General Liability insurance of at least $1,000,000 per occurrence. The contract is subject to the Service Contract Act (Wage Determination No. 2005-2248) and the Davis-Bacon Act, with a minimum wage of $13.65 per hour applicable through December 31, 2026. Bids must be submitted on company letterhead by October 23, 2026, and include a W9, Vendor Questionnaire, Authority to Commit, and a certificate of insurance. Payment terms are NET 30 days. Personnel performing work on-site must adhere to strict security protocols, including searches and a prohibition on fraternization with students and staff. All deliveries must be coordinated through the Center's security personnel.
Miami Job Corps Center

POSTED

about 16 hours ago

DEADLINE

in 1 day
NAICS: 238220
New
CBP6585 Bldg. 22 HVAC Replacement
Solicitation # CBP6585
Management & Training Corporation (MTC) is seeking bids for a fixed-price, single lump sum subcontract to replace the HVAC equipment serving Building 22 at the San Diego Job Corps Center in Imperial Beach, California. The scope of work includes the removal of existing equipment and the installation of a new 5-ton condenser with a suitable pad, a new furnace, a 5-ton evaporator coil, a fused electrical disconnect, an electrical whip, and a new condensate drain line. The contractor is responsible for providing all labor, materials, and supervision, ensuring the system is fully operational and compliant with applicable codes. Key deliverables include two sets of operation and maintenance manuals and manufacturer and installer warranties. The estimated price range for this project is between 0 and 25,000 dollars. Bids are due by October 28, 2026, and must be submitted using the MTC Bid for Lump Sum Contract form, accompanied by a detailed cost breakout, proof of insurance, and three references. A physical site visit and signature on the attendance roster are mandatory prerequisites for bid submission. For bids equal to or greater than 25,000 dollars, a bid bond of 20 percent of the base bid is required, and the awarded contractor must provide performance and payment bonds for 100 percent of the contract price from a surety with at least an A- rating. This opportunity is set aside for small businesses under NAICS 238220. Award decisions will be based on overall best value. Compliance requirements include the Davis-Bacon Act for prevailing wages, OSHA safety standards for personal protective equipment, and various Federal Acquisition Regulations, including those regarding first-tier subcontractor information and the submission of form SF 1413. Awarded contractors must provide a Unique Entity ID (UEI) number and complete the MTC Supplier Self-Certification packet. Payment will be made via progress payments based on percentage completion, utilizing AIA Document G702 and G703 or equivalent forms.
San Diego Job Corps Center

POSTED

about 16 hours ago

DEADLINE

in 8 days
NAICS: 238220
New
MJCC EXHAUST FANS BLD. 1429
Solicitation # mjcc-exhaust-fans-bld-1429
The Muhlenberg Job Corps Center, operated by Insights Training Group LLC, is soliciting fixed-price quotes from qualified HVAC and mechanical contractors to restore the exhaust fan and louver systems in Building 1429 located in Kentucky. The scope of work includes the inspection, repair, and replacement of various components across eight exhaust fans, specifically addressing failed louver actuators, motor replacements, selector switch repairs, and the relocation of a thermostat. Contractors must provide detailed line-item pricing for each fan, separate pricing for system-wide component replacements, and detailed costs for labor and materials. This solicitation is set aside for small businesses, including VOSB, SDVOSB, WOSB, and HUBZone certified entities. Award will be granted to a single responsible offeror based on technical acceptability and the lowest price. Key requirements include compliance with the Federal Acquisition Regulation, Davis-Bacon Act labor standards, and OSHA and EPA regulations. Contractors must be registered and licensed in the State of Kentucky, provide proof of insurance, and demonstrate the ability to secure performance and payment bonding. Administrative requirements include the submission of weekly certified payroll with every invoice and the provision of Materials Safety Data Sheets for all products used on site. The project involves a substantial completion process requiring a walk-through and final acceptance inspection. Quotes must be submitted electronically to the purchasing agent by October 30, 2026, and must include a completed New Vendor Profile and W-9 for any subcontractors.
Muhlenberg Job Corps Center / Insights Training Group LLC

POSTED

about 16 hours ago

DEADLINE

in 9 days
NAICS: 238220
New
Furnace Replacement
Solicitation # 26-17
Management & Training Corporation (MTC), operator of the Tongue Point Job Corps Center in Astoria, Oregon, is soliciting bids for a fixed-price, lump sum contract to replace furnaces and thermostats in three staff houses. The project involves Quarters F (3,786 sq/ft, propane), Quarters P (1,100 sq/ft, natural gas), and Quarters Q (2,280 sq/ft, propane). Required equipment must be Carrier Comfort Series or an equivalent household good grade with at least a 96% efficiency rating, sized at approximately 80,000btu. Installations must include new transitions to existing ducting, gas regulators, electrical and condensate pump kits, and intake/exhaust venting. A lifetime warranty on the heat exchanger and a minimum 10-year warranty on parts are mandatory. The estimated price range for this solicitation is between $0 and $25,000, with bids due by October 21, 2026. This is a small business set-aside opportunity under NAICS code 238220. Award decisions will be based on overall best value. Contractors must comply with the Davis-Bacon Act and applicable prevailing wage determinations, providing certified payroll weekly. Bid and performance bonds are only required for bids equal to or exceeding $25,000. Submission requirements include a signed MTC bid form, a detailed cost breakout on company letterhead, a Unique Entity Identification number, and a completed supplier self-certification packet. Final acceptance is contingent upon functional testing, the submission of operation and maintenance manuals, and a final inspection.
Tongue Point Job Corps

POSTED

about 16 hours ago

DEADLINE

in about 13 hours
NAICS: 238220
New
Centennial Dry Sprinkler System & Compressor Replacement Services
Solicitation # centennial-dry-sprinkler-system-compressor-replacement-services
Management & Training Corporation (MTC) is soliciting bids for a fixed-price, single lump sum subcontract to provide dry-type sprinkler system and compressor replacement services at the Centennial Job Corps Center in Nampa, Idaho. The project scope involves the demolition and removal of the existing dry system distribution piping network and failing air compressor across the Men's Dormitory (Building CM), Women's Dormitory (Building CW), and Recreation Building (Building D). The selected licensed fire sprinkler contractor must eliminate system leaks and install a new compressor sized according to NFPA standards to prevent equipment short-cycling. All work must adhere to NFPA 25 (2023 Edition) and local, state, and national codes, with a required performance period of 30 consecutive business days following the Notice to Proceed. Bids are due by December 1, 2026, and must be based on a mandatory site visit. Evaluation is based on overall best value and bidder responsiveness. For bids totaling $25,000 or more, a bid bond of 20% of the base bid is required at submission, and the awarded contractor must provide performance and payment bonds from an A-rated surety within five business days of the Intent to Award. Compliance requirements include adhering to Davis-Bacon prevailing wage rates for Idaho, submitting weekly certified payroll reports, and providing a 12-digit UEI number. Additionally, first-tier subcontractors with awards exceeding $45,000 must disclose debarment status per FAR 52.209-6, and contracts valued at $40,000 or more are subject to FFATA reporting.
Management & Training Corporation/Centennial Job Corps Center

POSTED

about 16 hours ago

DEADLINE

in about 1 month
NAICS: 238220
New
MJCC HVAC BLD. 1403-04 B HALL
Solicitation # mjcc-hvac-bld-1403-04-b-hall
Insights Training Group LLC, on behalf of the Muhlenberg Job Corps Center, is soliciting fixed-price quotes for an HVAC project at Building 1403-04 B Hall in Kentucky. The scope of work requires the contractor to furnish and install two 4-ton Trane split systems with a minimum 17 SEER rating, two 95% AFUE high-efficiency gas furnaces, and matching indoor evaporator coils using R-454B refrigerant. Additional requirements include the installation of a Honeywell Pro 8000 programmable thermostat, new refrigerant line sets, condensate drain piping, and pumps. The project must be completed within 45 days of award, and the contractor is responsible for all inspections, testing, and providing necessary operating and maintenance manuals. The contract will be awarded to the responsible offeror who is technically acceptable and provides the lowest price. To be considered, bidders must be registered and licensed in the State of Kentucky, verified through the SAM portal, and provide a minimum 90-day bid guarantee along with proof of ability to secure performance and payment bonding. Compliance with the Davis-Bacon Act and Certified Payroll Wage Rate requirements is mandatory, with weekly certified payroll and a signed Statement of Compliance required for invoice acceptance. All work must adhere to local codes, manufacturer specifications, OSHA, and EPA regulations. Quotes are due by October 30, 2026, and must include detailed labor and materials costs, a W-9, and a New Vendor Profile.
Muhlenberg Job Corps Center / Insights Training Group LLC

POSTED

about 16 hours ago

DEADLINE

in 9 days
NAICS: 238220
New
Roswell JCC – Male Dormitory Bldg. Water Source Heat Pump Replacement (20 units)
Solicitation # roswell-jcc-male-dormitory-bldg-water-source-heat-pump-replacement-20-units
Career Systems Development Corporation is soliciting proposals for the total replacement of twenty ceiling-mounted water source heat pumps at the Roswell Job Corps Center Male Dormitory Building 558 in New Mexico. The scope of work includes the removal and off-site disposal of twenty failed units and the installation of new Bosch 1-ton units or equivalent, including all necessary ducting, electrical, gas, thermostat wiring, flexible hoses, and pressure valves. Additionally, the contractor must install smoke dampers with fusible links in all vents leading into the plenum and ensure all materials used in the plenum are plenum-rated. All work must comply with NFPA 101, NFPA 70, and applicable plumbing, mechanical, and building codes, with performance scheduled between 7:00 am and 4:00 pm, Monday through Friday. This solicitation is set aside for small businesses, including VOSB, SDVOSB, WOSB, and HUBZone certified firms. The project is subject to the Davis Bacon Act Wage Determination NM20260014, requiring the submission and approval of weekly certified payroll reports prior to invoice payment. Proposals exceeding $100,000.00 require payment and performance bonding for 100% of the contract value. Submissions must include a safe work process, detailed costs for labor and materials, equipment cut sheets, warranty information, and a requested payment schedule. Final deliverables include the provision of operation manuals to the Facility Manager upon project completion.
Career Systems Development Corporation

POSTED

about 16 hours ago

DEADLINE

in 17 days

General Info

NAICS

238220 - Plumbing, Heating, and Air-Conditioning Contractors

Place of Performance

TN

Set-Aside

NONE

Documents

1

RFI - Boiler Maintenance at York Campus (36C24924Q0332)

DOCX, Low priorityrfi
Low

AI Contract Breakdown

Uniform Contract Format

Contract not broken down yet

CLEATUS splits the solicitation into Uniform Contract Format (UCF) sections: scope, pricing, deliverables, and evaluation criteria.

Timeline

PhaseClosed
Posted

Sources Sought

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Start your free trial to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Veterans Affairs → 249-NETWORK Contract Office 9 (36C249)
Contacts1 person available
OfficeMURFREESBORO, TN, 37129, USA
Office AddressMURFREESBORO, TN, 37129, USA
Contacts
Michael EdwardsContract Specialist

Full Description

Show more
Request for Information 36C24924Q0332 On behalf of the Tennessee Valley Healthcare System, Network Contracting Office (NCO) 9 is issuing this Request for Information (RFI) as a means of conducting market research to identify parties having an interest in and the resources to support this requirement for a firm-fixed priced contract for preventive maintenance and repair service on the boilers, boiler controls, boiler plant ancillary systems and controls in accordance with references below at the VAMC, Alvin C. York Campus, 3400 Lebanon Pike, Murfreesboro TN, 37129. The applicable North American industry services Classification System (NAICS) code assigned to this procurement is 238220. THERE IS NO SOLICITATION AT THIS TIME. This request for capability information does not constitute a request for proposals or quotes; submission of any information in response to this market survey is purely voluntary; and the government assumes no financial responsibility for any costs incurred. If your organization has the potential capacity to perform these services, please provide the following information: Organization name, address, point of contact, email address, Web site address, and telephone number. Business size: small, small disadvantaged, woman-owned, Hub Zone, serviced-disabled veteran-owned small business, large business, etc. Business type under North American Industry Classification System (NAICS) 238220, which contains a size standard of $19.0 Million, CAGE Code and DUNS Number. Under which NAICS code does your company usually provide the requirements described in the Performance Work Statement - Please provide rationale for your answer if different from NAICS 238220. Tailored capability statements addressing the particulars of this effort, with appropriate documentation supporting claims of organizational, and staff capability. Response to this Request for Information shall not exceed 25 pages and should include all the foremost mentioned information. In addition, all submissions should be provided electronically in a Microsoft Word or Adobe PDF format. The government will evaluate market information to ascertain potential market capacity to: Provide services consistent in scope and scale with those described in this notice and otherwise anticipated. Secure and apply the full range of corporate financial, human capital, and technical resources required to successfully perform similar requirements. Implement a successful plan that includes compliance with program schedules; cost containment; meeting and tracking performance. Provide services under a firm-fixed price contract. If the contractor is planning to use a subcontractor, please provide their name, address, location and credentials. NOTE: Respondent claiming SDVOSB and VOSB status shall be registered, and Center for Veteran Small Business Certification (VetCert) in the VetCert Registry veterans.certify.sba.gov BASED ON THE RESPONSES TO THIS REQUEST FOR INFORMATION NOTICE/MARKET RESEARCH, THIS REQUIREMENT MAY BE SET-ASIDE FOR SDVOSB, VOSB, SMALL BUSINESSES OR PROCURED THROUGH FULL AND OPEN COMPETITION. Submission Instructions: Interested parties who consider themselves qualified to perform the services are invited to submit a response to this RFI by 9:00am CT, July 8, 2024. All responses under this RFI must be emailed to Michael Edwards2@va.gov. Telephone inquiries will not be accepted or acknowledged, and no feedback or evaluations will be provided to companies regarding their submissions. SAM: Interested parties shall be register in the System for Award Management (SAM) in accordance with FAR 52.204-7. SAM information can be obtained by accessing the following link: https://sam.gov/content/about/contact or by calling 1-866-606-8220. Disclaimer and Important Notes. This notice does not obligate the government to award a contract or otherwise pay for the information provided in response. The government reserves the right to use information provided by respondents for any purpose deemed necessary and legally appropriate. Any organization responding to this notice should ensure that its response is complete and sufficiently detailed to allow the government to determine the organization s qualifications to perform the work. Respondents are advised that the government is under no obligation to acknowledge receipt of the information received or provide feedback to respondents with respect to any information submitted. After a review of the responses received, a pre-solicitation synopsis and solicitation may be published in Contract Opportunities. However, responses to this notice shall not be considered adequate responses to a solicitation. PERFORMANCE WORK STATEMENT FULL MAINTENANCE ON BOILERS AND CONTROLS Alvin C. York Campus. INTRODUCTION This requirement is to provide a base year plus 4 option years for full maintenance, (contractor will supply all parts replacement and repairs) preventive maintenance (PM) and repair service on the boilers, boiler controls, boiler plant ancillary systems and controls in accordance with references below at the VAMC, Alvin C. York Campus, 3400 Lebanon Pike, Murfreesboro TN, 37129. SCOPE OF WORK Offeror (aka Contractor) shall furnish all transportation, labor, parts, and materials (for all general maintenance), tools and equipment necessary to inspect, calibrate, adjust, repair and maintain in first class operating condition the boilers, boiler combustion controls, associated recording instrumentation (boiler computer system) burner management, flame failure controls, De-aerating Feed Tank (DA Tank), feedwater controls, condensate return controls, pressure reducing valves (PRV), and safety devices, on all boilers listed below in the boiler plant and in the manner and frequency as stipulated in the VHA Boiler Safety Manual current edition. See requirements (section C) for list of equipment needed. Service visits shall include operator training for the annual boiler inspections outlined in Appendix A scheduled and safety device training during the monthly device training for boiler operators as required by VHA 1810. All work shall be coordinated with the Utility Systems Operations Supervisor (USO Sup.) and or Contract Officer Representative (COR) Usually the same person at the ACY Campus and done with boiler operators for training purposes. Safety checks and fuel/air settings must be in accordance with excess air requirements as set by the manufacturer (Cleaver Brooks) for the specific boiler type and by the VA VHA Boiler Plant Safety Devices Testing Manual, current edition and VHA Directive 1810, described in Appendix A. Combustion calibration of oil and gas must be made from 0% to 100% in 5% increments. Check pilot light ignition on natural gas and propane. Test and calibrate boiler water level control system to include high and low water alarm systems. Complete all boiler safety checks in Boiler Plant as listed in the safety manual, test conducted and at a time frequency described in the VHA Boiler Safety Manual Current edition per reference. Any device, system, or part failure should be reported immediately to the USO Supervisor. It is expected that upon the completion of the required service, inspection, and repairs, that all boilers shall be returned to normal operating condition by the Contractor. Site work shall commence with a meeting with the Contractor and the USO Supervisor. The purpose of this meeting is to address the following items as may be appropriate: Review Boiler Plant safety regulations and lockout/tagout procedures Discuss the nature of the planned activities. Coordinate activities with other outage events. Must have service/repair to include a minimum of 8 (eight) hours per week. If repairs take longer, the time will be included in this contract until the boilers are up to par. This is a FULL MAINTENANCE AND REPAIR CONTRACT, Contractor is to provide manufacture s authorized/certified service technicians, transportation, equipment, maintenance, and all repair parts, material, tools (to include specialty tools) supervision, and administration to complete all required repairs, Preventive Maintenance (PM), calibration and replacement for the mechanical and or electric components needed to maintain Boilers at full and safe operations. As provision for this contract, the Contractor shall fully supply and continually maintain ALL parts on hand to repair, maintain and perform routine maintenance and PM to the boilers at no extra cost to the Government. REQUIREMENTS All work must be performed by a certified and experienced service technician during normal working hours from 8:00 am 4:30 pm Central Time, Monday through Friday including ALL Federal and local Holidays. Boiler Plant equipment: There are three Cleaver Brooks high pressure gas and oil-fired fire tube boilers with Hawk 4000® controls, Model 4WI-200-600-200. The boilers are 600 HP and operate at approximately 100 psi, one Superior waste heat boiler, an assembly of the Co-generation plant, utilizing the engine exhaust and produces 3000 pounds of steam per hour at approximately 110psi. This Contract is responsible for the boiler portion of the Co-Generation plant and any interconnection safety controls and wiring connections of the boiler. The Engine and power generation portion of the Co-Generation plant is maintained under a separate service contract (by others). (1) Three Cleaver Brooks fire tube boilers and associated safety devices (2) Three Hawk 4000 Control Panels (3) Three Operating Steam Pressure Limit (4) Six Steam Pressure Limit switches, one recycles and one reset (Mercoid Switch) (5) Nine Safety Relief Valve testing (3 on each boiler) (Kunkle 125, 130, 135 psi) (6) Three Antunes Purge Air Flow Switches (7) Three High furnace pressure switch (8) Three Primary Low water Cleaver Brooks (9) Three Warrick dual probe for water level and high and low water alarms (10) Three Fire-eye self-check UV scanner flame scanner (11) Three Combustion air pressure switch (12) Three ignition timing and flame confirmation (IR Fire eye) (13) Three System failure Response time (14) Three Low Gas Pressure (15) Three Low gas Pressure Antunes (16) Three High Gas Pressure Antunes (17) Three Low Gas Pressure Antunes (18) Six Main gas valve POC and leak test (19) Six Main oil valve POC and leak test (20) Three Low atomizing air pressure switch Mercoid (21) Three Low oil pressure switch Mercoid (22) Three High oil pressure switch Mercoid (23) Three Low oxygen sensors (24) Master Lead/Lag Controller Cleaver Brooks (25) De-Aerator Feed Tank Controls ADAC (26) Combustion controls shall be adjusted to maintain proper fuel/air ratio for most efficient and safe operation throughout the firing range at a maximum of 5% intervals. (27) Calibration of all transmitters and meters to ensure accurate reading. (28) Testing of PRV s, steam stations, and accumulation test per VA Safety Manual. (29) Testing of all safety devices on DA Tank (30) Calibration of gas sensors and alarms in boiler plant. (31) Boiler computer monitoring network. (32) Three high water alarm conductivity probes (Warrick) (33) Calibrate all flow transmitters (Steam, Gas, Oil, Water) (34) Any Boiler safety or Plant safety items in VHA Boiler Safety Manual not listed above. General requirements Boilers excess air and oxygen shall be maintained throughout the firing range on gas and oil in accordance with burner manufacturer s burner recommendations (Cleaver-Brooks) Exhaust gas test is conducted using Yokogawa® EGA system or Equivalent. System should be checked for calibration and proper operation per manufacturer recommendations. Equipment calibration records shall be provided to the Government (see Section G.b). All Boilers must be tuned on gas and oil every Quarter; Preventive Maintenance to include the normal boiler inspections, gauge calibration, opening the boilers and DA tanks for inspection. Each Boiler and DA tank are opened once per year. Specific dates for opening the Boiler and DA tank shall be coordinated with the Government to minimize impact to the Medical Center campuses normal day-to-day operations. Contractor must have full and complete test equipment and tools of the trade required for testing and calibrating Cleaver-Brooks boilers with Hawk 4000 and Autoflame controls including combustion software (latest version), laptop, connection cord to connect laptop to Hawk 4000 and Autoflame, Digital Manometer (calibrated annually, proof of calibration is required as part of deliverable report in Section G.b), nitrogen pressure tank and connection fittings/assembly to test boiler safeties as required in the VHA Boiler Safety Manual (most recent) Edition, digital device to calibrate flow transmitters (such as a Yokagowa), and test gas and device to test gas detection system for the boiler plant. Contractor to supply their own various handheld tools including electrical meters, jumpers, wrenches, screw drivers, etc., typical and standard for the execution of this work. The Contractor is required to provide all their own tools and equipment; none shall be provided by the VA. VA equipment may be used when training VA boiler operators if VA equipment differs in operation from vendor. COMPETENCY OF CONTRACT PERSONNEL (Qualifications): An experienced and certified industrial boiler service representative is required. Minimum 3 years of proof of experience and training of Contractor personnel must be provided to the Government for review and concurrence of adequacy. No welded repairs are permitted except by certified welders using code-approved procedures, welding certification must be provided, and hot work permit acquired for enclosed locations from VA Safety department prior to welding work repairs. Contractors should be trained in Hawk 4000 boiler control systems and the Auto Flame boiler control systems and have a minimum of three years of boiler calibration and safety checks on all standard type of boiler devices and switches and testing in manner and frequency of VHA Boiler and Associated Plant Safety Device Testing Manual, Current Edition. Detailed maintenance plan for the equipment weekly, monthly, quarterly, bi-annual, and annual checks to be setup with the Utility Systems Supervisor. Schedule: The Contractor shall schedule with the Contract s Contracting Officer Representative (COR) and/or the Utility System Supervisor. The Contractor shall perform PM and normal maintenance during normal business hours, (unless other times are stipulated by the COR (typically the Utility Systems Supervisor). Special Considerations: Emergency call responses are a requirement of this contract. Emergency calls on all down, damaged, or inoperable Boilers and Other Equipment for the Boiler plants equipment, as detailed in this Contract, can be executed at any time (24 hours per day, 7 days per week) with a maximum Contractor response time of two-hour emergency response time to arrive at the VA facility in need of troubleshooting, repairs, and/or maintenance. DELIVERY Work: All work must be performed by a certified and experienced service technician during normal working hours, 8:00 a.m. to 4:30 p.m. Central Time, Monday through Friday. Weekly services shall be coordinated with the facility COR and shall include a minimum of 8 working hours. Monthly visits will include safety device test, these visits will last until the tests are completed (usually one or two days) these visits are in addition to the weekly visit. Each service visit during the months of October, January, April, and July shall consist of a minimum of five (5) days or longer, until all schedule maintenance is completed. Repairs not completed during the weekly visits that are deemed necessary for boiler plant operations will require the contractor to work additional time until the repairs are completed and to MAINTAIN MINIMUM N+1 REDUNDANCY. Rescheduling Process: If selected offeror cannot meet this required schedule, a three-week written notice is required and shall include the proposed new dates for subject visit. This written notification shall be provided to the VA Contracting Officer and COR for agreement if conditions don t permit a visit during the designated month. During preventative maintenance (PM) inspections and emergency service calls the service technician will be accompanied by the Utility Systems Operator Supervisor or a designee thereof. Service visit shall include training of Boiler Plant Operators on operation and testing of safety devices. Contractor should work closely with VA boiler operators during all phases of calibration and testing. PROGRESS AND COMPLIANCE After each scheduled PM or emergency maintenance call is complete, the qualified service technician shall leave a signed service ticket with the Utility Systems Operator Supervisor or his designee detailing work completed at each location, failure of any device, and recommended remedial action (to include parts replaced by Contractor). Deliverables: The Contractor shall provide the CORs professional, accurate, complete, and consistent reports in electronic PDF files. Reports shall include any pertinent information necessary to ensure the Boilers are performing at manufacturer s design specifications. Reports are due to the CORs within ten (10) working days upon completion of all calibrations and PM s. Qualifications of Key Personnel: Contractor s employees should be knowledgeable of and trained in methods and standards generally associated with this type of work. Quality Assurance: The COR is responsible for the inspection of the work called for in this job. The Government shall identify the COR assigned to this Contract by name, telephone number, and location. Quality Assurance inspections made by the COR are for the sole benefit of the Government and do not relieve the Contractor of any Quality Control responsibilities. OTHER INFORMATION Security Requirements: Contractor shall identify which employees will be working under the awarded contract. Contractor personnel shall include employees, sub-contractors, subcontractor employees, suppliers and delivery personnel entering the Medical Center. This does not apply to suppliers and delivery personnel making deliveries to the VA warehouse dock only. Those employees identified shall bring photo ID to obtain a VA Contractor identification badge and that badge shall be worn visibly by Contractor personnel above the belt always while on Medical Center property. Contractor's employees shall return all I.D. badges to designated personnel at time designated in the task order. Smoking Policy: The Contractor shall not allow smoking at any TVHS property. Site Cleanup: The Contractor shall always keep the work area, including storage areas, free from accumulations of waste materials. Licensures and Permitting: The Contractor shall, without additional expense to the Government, be responsible for obtaining any necessary licenses and permits, and for complying with any Federal, State, and municipal laws, codes, and regulations applicable to the performance of the work. The Contractor shall also be responsible for all damages to persons or property that occur because of the Contractor s fault or negligence. Parking/Traffic Regulations: The Contractor shall not park on grassy areas unless approved by the COR and the Contractor agrees to restore areas back to VA standards. Drivers should be particularly concerned with pedestrian traffic. Yield to pedestrians in crosswalks. Posted speed limits and all other traffic controls are always to be observed by operators. Seat belt use is mandatory on the VA grounds. Site Visit: The Contractor shall visit the job site to thoroughly familiarize himself with all the details of the work and working conditions. The Contractor shall be specifically responsible for the coordination and proper relation of his work and ensure the safety of employees and workmen. Contractor Required Visit Inspections Frequency and Test Schedule and Operational Test: Every October is the month for yearly test and inspection, and April is the 6-month inspection. Per VHA Directive 1810 (MOST RECENT) and VHA Boiler and Associated Plant Safety Device Testing Manual (MOST RECENT) Key to Frequency Abbreviations Term Abbreviation High Pressure Steam Boiler HP Low Pressure Steam Boiler LPSB Hot Water Boiler HWB Electric Hot Water Boiler EHWB Electric Steam Boiler ESB Once per month M Once every 6 months. 6M Once per year Y Once every 6 years 6Y Frequency Chart SAFETY DEVICE TESTING AND INSPECTION FREQUENCY REQUIREMENTS 1 Inspect furnace and other internal surfaces, closures, and accessories. Y 2 Inspect exterior of Unit, casing, supports, closures, accessories, valves, controls. Y 3 Check all Boilers for fouling and combustion gas flow. Y 4 Tube leak check on all boiler types. Y 5 Deaerator: interior cleaning and visual inspection. Y 6 Condensate Tank: interior cleaning and visual inspection. Y 7 Adjust burner combustion settings and calibrate oxygen trim. 6M 8 Check vibration of burner fans. 6M 9 Calibrate instrumentation, monitoring, and control systems. 6M 10 Calibrate pressure gages and thermometers. Y 11 Test functionality of UPS systems. Y 12 Boiler chimneys and stacks, by a qualified inspector. 6Y 13 Emission control system inspection and testing (SCRs etc.). Y 14 Check furnace pressure. 6M 15 Check combustion gas leaks into boiler room. 6M 16 Clean waterside of boilers. Y 17 Clean fireside and repair refractory. Y 18 Review written procedures. Y 19 High Water Alarm on Condensate Tank (HWACT) 6M 20 Low Water Alarm on Condensate Tank (LWACT) 6M 21 High Water Alarm on Deaerator Tank (HWADT) 6M 22 Low Water Alarm on Deaerator Tank (LWADT) 6M 23 Deaerator Overflow Drain System (DAODS) 6M 24 Deaerator Safety Valve (DASV) 6M 25 Steam Safety Valve Following PRV (SVFPRV)-Deaerator 6M 26 Steam Safety Valve Following PRV (SVFPRV) 6M 27 Liquid Relief Valve on Oil Pump Set (LRVOPS) 6M 28 Liquid Relief Valve on Economizer (LRVE) 6M 29 Control Air Pressure Alarm (CAPA) 6M 30 Carbon Monoxide and Combustible Gas Alarms in the Boiler Plant (CMCGABP) 6M 31 Emergency Stop/Panic Buttons (ESPB) Y 32 High Fuel Gas Pressure Alarm on Main Gas Line (HFGPAMG) 6M 33 Low-water cutoff (slow drain) (LWCO) M 34 Fire each boiler and the pilot on the alternate fuel for 1 hour M 35 Auxiliary low-water cut-off (slow drain) (ALWCO) M 36 High-water alarm on Boiler (HWAB) M 37 Low-water alarm (LWA) M 38 High Boiler Steam Pressure Limit Switch (HBSPLS) 6M 39 High High Boiler Steam Pressure Limit Switch (HHBSPLS) 6M 40 Steam safety valves lift test (SVB) 6M 41 Steam safety valves (accumulation test at high fire) Y 42 Low Fuel Gas Pressure Cutoff Switch (LFGPCS) 6M 43 High Fuel Gas Pressure Cutoff Switch (HFGPCS) 6M 44 Automatic Fuel Gas Shutoff Valves and Solenoid Vent Valve Seat Leakage (AFGSOV & AFGSVV) Main Gas Line 6M 45 Automatic Pilot Fuel Gas Shutoff Valves and Automatic Pilot Fuel Gas Solenoid Vent Valve Seat Leakage (APFGSOV & APFGSVV) Pilot Line 6M 46 Proof of Closure on Automatic Fuel Shutoff Valves (POC-AFGSOV) Natural Gas 6M 47 Flame Scanner-for main flame out (FSMFO) M 48 Flame Scanner Not Sensing Igniter Spark (FSNSIS) 6M 49 Igniter Timing (IT) 6M 50 Main Flame Ignition Timing (MFIT) 6M 51 Pre-Purge and Post-Purge Timing (PPT) 6M 52 Low-Fire Proving Switch (LFPS) 6M 53 Forced Draft Damper Wide-Open Pre-Purge Proving Switch (FDDWOPS) 6M 54 Combustion Air Pressure Switch (CAPS) 6M 55 Purge Airflow Proving Switch (PAPS) 6M 56 Forced Draft Motor Interlock Switches (FDMIS) 6M 57 Outlet Stack Damper Position Interlock Switch (OSDPI) 6M 58 Furnace Pressure Interlock (FPI) 6M 59 Low Pilot Fuel Gas Pressure Cutoff Switch (LPFGPCS) 6M 60 Flue Gas Recirculation Damper Interlock (FGRDI) 6M 61 Low Flue Gas Oxygen Level Interlock (LFGOLI) 6M 62 Low Fuel Oil Pressure Cutoff Switch (LFOPCS) 6M 63 High Fuel Oil Pressure Cutoff Switch (HFOPCS) 6M 64 Low Atomizing Media Pressure Switch (LAMPS) 6M 65 Low Atomizing Media Differential Pressure Switch (LAMDPS) 6M 66 Secondary Low Atomizing Media Pressure Switch (SLAMPS) 6M 67 Automatic Fuel Oil Shutoff Valves (AFOSV) - for Seat Leakage 6M 68 Proof of Closure on Automatic Fuel Oil Shutoff Valves (POC-AFOSV) Oil 6M 69 Oil Burner Position Switch (OBPS) 6M Note: Boiler Efficiency Institute (BEI) testing sheets should be used for each test and include the make, model, setting, trip point, whether the test passed or failed, and if failed recommended repair. Complete report should be given to the Utility System Supervisor prior to leaving the boiler plant on the 5th day of scheduled visit detailing all Contractor work including the testing of safety devices listed above, and all combustion and emission data at 5% intervals.

More opportunities from Department Of Veterans Affairs → 249-NETWORK Contract Office 9 (36C249)

Same awarding agency

NAICS: 238220
New
Federal
TVHS AC VRF System Installation
Solicitation # 36C24927Q0016
Solicitation 36C24927Q0016 is a request for a single-award, firm-fixed-price purchase order from the Department of Veterans Affairs to provide HVAC services at the Tennessee Valley Healthcare System Nashville Campus. The project involves the removal of an existing condenser and three air handling units and the installation of a new Variable Refrigerant Flow (VRF) system for five office spaces near the boiler office. The scope includes system start-up, testing, commissioning, and balancing of airflow and temperature control. The period of performance is scheduled from November 1, 2026, through December 31, 2026, with specific work hours designated for Friday through Sunday between 1800 and 2400 hours. This requirement is 100% set-aside for certified Service-Disabled Veteran-Owned Small Businesses (SDVOSB) under NAICS code 238220. Award decisions will be based on a Best Value comparative evaluation considering technical capability, past performance, and price. The contractor is required to adhere to industry standards, OSHA 29 CFR 1910, and NFPA 70E safety guidelines. Key deliverables include operational verification documentation, daily field inspection reports, and a final written report submitted within ten working days of completion. Invoices must be submitted electronically, and payments will be processed via Electronic Funds Transfer.
Plumbing, Heating, and Air-Conditioning Contractors

POSTED

5 days ago

DEADLINE

in 2 days
View Details

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS