J049--Sources Sought Notice Need a contractor for Generator Testing Services Louis A Johnson VA Medical Center 36C24526Q0352

Closed
36C24526Q0352Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 811310
New
Kubota M8200 Clutch Replacement
Solicitation # kubota-m8200-clutch-replacement
Management and Training Corporation is soliciting lump sum fee proposals for the clutch replacement of a Kubota M8200 tractor with front wheel assist, located at the Earle C. Clements Job Corps Center in Morganfield, Kentucky. The scope of work requires a qualified contractor to provide all transportation, labor, materials, and equipment to diagnose and repair the clutch assembly and power take-off system. Key technical requirements include replacing friction discs, bearings, oil seals, and O-rings, resurfacing the flywheel, and replacing hydraulic pipes and filters as needed. The contractor must perform all work according to manufacturer specifications and provide a final summary of diagnostic findings, an itemized list of replaced parts, and warranty documentation upon completion. This solicitation is set aside for small businesses, including VOSB, SDVOSB, WOSB, and HUBZone certified entities. Bids must be submitted via email to Angie Mahoney by 3:00 PM CST on November 3, 2026, and must include a bid sheet, proof of insurance, a completed supplier packet with a W-9, and applicable SBA certification letters. Award decisions will be based on best value, with a focus on administrative compliance and technical qualifications. The contract is subject to various Federal Acquisition Regulations, including standards for combating trafficking in persons, Buy American restrictions, and Service Contract Labor Standards per Wage Determination 2015-4687 Revision 31 for Kentucky.
Earle C. Clements Job Corps Center

POSTED

about 1 hour ago

DEADLINE

in 5 days
NAICS: 811310
New
SLED
RFP 07-135 Roseville Electric Utility – Air Compressor Maintenance
Solicitation # 07-135
The City of Roseville is soliciting proposals under RFP 07-135 for a consultant to provide comprehensive scheduled preventive and corrective maintenance for air compressors and auxiliary systems, including Ingersoll Rand equipment. The services will be performed at the Roseville Energy Park and Sunset Energy Center in California. The selected consultant will be responsible for providing all necessary labor, technical expertise, specialized tooling, and materials. This is a prevailing wage project with an initial contract duration of five years, estimated to commence in April or May. Proposals must be submitted by December 16, 2026, via email to the City Clerk or through physical delivery in a sealed container with the required Attachment H label. The award will be based on a formal evaluation panel process considering the firm's experience and qualifications (25 points), the proposed project plan (35 points), and cost (40 points), with potential interviews for top candidates. Requirements for the successful bidder include obtaining a City of Roseville business license, providing 100% faithful performance and labor and materials bonds, and maintaining specific insurance policies. Consultants must also disclose any conflicts of interest and adhere to the Levine Act regarding political contributions.
City of Roseville

POSTED

about 7 hours ago

DEADLINE

in about 2 months
NAICS: 811310
New
SLED
Roseville Electric Utility – Gas Compressor Maintenance
Solicitation # 07-137
The City of Roseville is soliciting proposals for Gas Compressor Maintenance Services to support the Roseville Energy Park and the Roseville Energy Center and RPEAK. The selected contractor will provide all labor, supervision, technical expertise, specialized tooling, equipment, and materials necessary for both scheduled preventive and corrective maintenance on natural gas compressors, specifically Gas Packagers and Ariel models, and their associated auxiliary systems. The contract is intended to run for an initial term of five years, with services estimated to commence in April or May. This is a prevailing wage project requiring adherence to all fair employment laws, with certified payroll required for contracts exceeding 25,000 dollars. The successful proposer must provide a 100 percent Faithful Performance Bond and a 100 percent Labor and Materials Bond. Proposals are due by December 17, 2026, and must include a Proposer’s Certification, a Non-collusion Declaration, a Levine Act Disclosure Statement, and proof of active registration with the California Secretary of State. Award will be made to the responsible proposer determined to be the most advantageous to the City through a formal evaluation panel process. Invoicing is to be submitted monthly, delineated by task and personnel, with payment terms set at 30 days following receipt of satisfactory services.
City of Roseville

POSTED

about 7 hours ago

DEADLINE

in about 2 months

General Info

NAICS

811310 - Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance

Place of Performance

Department of Veterans Affairs Louis A. Johnson VA Medical Center, Clarksburg, WV, 26301, USA

Set-Aside

NONE

Documents

2

Sources Sought Notice for Generator Testing Services 36C24526Q0352

PDF, High priority: read this first6 pages · sources-sought
High

Sources Sought Notice for Generator Testing Services 36C24526Q0352

DOCX, High priority: read this first8 pages · sources-sought
High

AI Contract Breakdown

Uniform Contract Format

Sign up to view the full breakdown with detailed analysis of each section.

Timeline

PhaseClosed
Posted

Sources Sought

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Veterans Affairs → 245-NETWORK Contract Office 5 (36C245)
Contacts1 person available
OfficeLINTHICUM, MD, 21090, USA
Office AddressLINTHICUM, MD, 21090, USA
Contacts
Bill PrattContracting Officer

Full Description

Show more
Summary:
Department of Veterans Affairs, Veterans Health Administration, Network Contracting Office 5, is issuing this request for sources sought notice in order to identify vendors that are interested in and capable of providing contractor services. For a contractor to provide Generator Testing Services for the Louis A Johnson VA Medical Center. Review last page for details on how to respond to this Sources Sought notice.
Scope of work: Location of work: Louis A Johnson VA Medical Center 1 Medical Ctr Dr, Clarksburg, WV 26301 Base plus Four (4) Option Year contract. This ensures the Louis A. Johnson VAMC maintains continuous compliance with the most recent VHA-adopted NFPA 110 and is fully prepared for The Joint Commission (TJC) and OIG inspections. 1.0 Contract Structure Base Year: [Dates] Option Years 1-4: To be exercised annually. Emergency Coverage: 24/7/365 On-call availability. 2.0 Scope of Work The contractor shall provide all labor, materials, and equipment to perform monthly, annual, and triennial testing, as well as emergency repair services. Monthly Operational Test Duration: Minimum 30 continuous minutes under facility load. Time-to-Transfer: Must reach operating voltage/frequency and transfer load within 10 seconds. ATS Rotation: Contractor shall rotate the initiating Automatic Transfer Switch (ATS) monthly to ensure all switches are cycled annually. Supplemental Load Bank Testing (As Required) In accordance with the most recent NFPA 110, Section 8.4.2, if a generator fails to reach the required 30% of the nameplate kW rating or the manufacturer s recommended exhaust gas temperature during the monthly run: Requirement: The contractor shall provide a portable load bank. Procedure: The unit shall be exercised for 2 hours annually at a load increasing to at least 75% of the nameplate rating. Triennial (36-Month) 4-Hour Run Once every 36 months, the contractor shall conduct a continuous 4-hour load test: First 3 Hours: Minimum 30% of nameplate kW. Final Hour: Minimum 75% of nameplate kW (utilizing a load bank if facility load is insufficient). 3.0 Emergency Response & Repair
Response Time: The contractor shall provide emergency repair services with a maximum 2-hour on-site response time from the initial call by the M&O Supervisor or Engineering Staff. Availability: This requirement applies 24 hours a day, 7 days a week, including holidays. Reporting: Any emergency repair must result in a "Return to Service" report documenting the FboNotice cause and the speci c NFPA 110 re-test performed to verify system readiness. 4.0 TJC & OIG Documentation Standards All reports must be "Audit-Ready" and submitted to the Facilities Management Service (FMS) within 72 hours. Speci c Data: Reports must include exact kW/Amperage, Hz, and exhaust temperatures. Battery Diagnostics: Conductance or speci c gravity readings are mandatory for each battery cell/unit. Certi cation: A signed attestation that the test met the most recent VHA/NFPA 110 performance criteria. 5.0 Contractor Quali cations & Safety Certi cation: Technicians must be EGSA-certi ed or factory-trained on VAMC-speci c assets. Safety: All work must comply with the most recent NFPA 70E standards. The contractor is responsible for all Arc Flash PPE and for establishing a safe working perimeter. Record Management. . Documentation Requirements: Date of test Start and end time. Total run duration. Generator identi cation number/location. Load percentage or kW output. Voltage and frequency readings.
Oil pressure and coolant temperature readings. Fuel level. Battery condition. Following NFPA 110.
7.0 Record Retention. Generator test records shall be maintained for a minimum of three (3) years. Records may be maintained electronically or in hard copy available to the facility when requested. 8.0 Generator Description.
GENSET #1 GENSET #2 GENSET #3 Manufacturer/Make/Year: Caterpillar Caterpillar Kato Model No: SR-4 C32 500SS9D Serial/Order No: 6NA01031 G1G00044 7319 Load Rating: (Emergency/Standby/Prime) 1000 kva 1250 kva 625KVA Power Factor: .8 .8 .8 Frequency: 60 Hertz 60 Hertz 60 hertz Load in Amperage: 1000 amps 1000 amps 87 Output Voltage: 480 480 volts 4160 volts Phase: 3-phase 3-phase 3-phase Building: Bld 17 Bld 17 Bld 17 Location (Area/Room): Generator room Generator Rm Generator Rm
GENSET #4 GENSET #5 (portable) Manufacturer/Make/Year: Kohler Baldor Model No: 100RE0ZJF TS225-3J
Serial/Order No: 3346GMJL0001 P1205240012
Load Rating: (Emergency/Standby/Prime) 128 kva 225 kva Power Factor: .8 .8 Frequency: 60 Hertz 60 Hertz Load in Amperage: 153 amps 625 amps
Output Voltage: 480 480 volts Phase: 3-phase 3-phase Building: Parking Garage Grounds Location (Area/Room): Parking Garage Grounds (portable)










Please respond to this RFI/Sources Sought 36C24526Q0352 with your: 1. Business name (including Unique Entity ID (SAM.gov) 2. Business type, socio-economic status (e.g., Veteran-Owned, Woman-Owned, Disadvantaged Small Business, 8(a), etc.), and 3. Person of contact (including telephone number & email address). 4. Capability statement and summary of previous experience providing these types of services for the Veterans Health Administration or other similar facilities. 5. Available contract vehicles (GSA FSS, etc.) for use by Department of VA (include applicable NAICS) 6. Brief Summary of categories of services that your company can/cannot provide. 7. Certification(s) / Licenses for meeting the local requirements to provide these services at the DC VAMC (if applicable) 8. Confirmation that your organization has the capability & expertise to meet the performance requirements while complying with applicable limitations in subcontracting by responding to the questions below with your response: a. Do you intend to self-perform this effort? b. If you are located outside the immediate area, how will you self-perform? c. Or do you intend to subcontract work under this contract? d. If you intend to subcontract work under this contract, how will you ensure compliance with the limitations on subcontracting? Response Instructions:
Responses must be submitted NLT 10:00 AM (ET) 03-20-2026, Responses to the information requested above must be submitted via email to Bill Pratt at contact@example.gov. Respond: 36C24526Q0352 Sources Sought Notice | Company Name
This request for information/sources sought notice is for planning purposes ONLY and does not constitute a solicitation, responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. The results of this market research will assist in the development of (1) the requirement, and (2) the acquisition strategy (e.g., SDVOSB/SDVOSB set-aside, small business set-aside, full and open.

More opportunities from Department Of Veterans Affairs → 245-NETWORK Contract Office 5 (36C245)

Same awarding agency

NAICS: 561210
New
Federal
J044--NOTICE OF INTENT TO SOLE SOURCE Baltimore VAMC Steam System Preventive Maintenance from Vicinity Energy Baltimore Corporation
Solicitation # 36C24527Q0048
The Department of Veterans Affairs is issuing a Notice of Intent to Sole Source for an open market award to Vicinity Energy Baltimore Corporation to provide annual steam system preventive maintenance at the Baltimore VA Medical Center. This requirement, classified under NAICS code 561210 and PSC J044, is driven by the fact that the facility's steam equipment is directly connected to the district steam distribution system owned and operated by Vicinity Energy. Due to this interconnected configuration and the proprietary operational data involved, the government identifies Vicinity Energy as the sole source capable of ensuring the reliable operation of the system without risking the broader distribution network. The scope of work requires a two-person crew to provide eight hours of service every two weeks, totaling 416 labor hours per year. Key responsibilities include steam trap surveys, cleaning pressure-reducing valves, inspecting heat exchangers, and ensuring proper water chemistry and meter operation. The contractor must supply all necessary parts meeting original manufacturer specifications and provide emergency call-back services with a technician on-site within five hours of notification. The anticipated period of performance is one year from the award date, with the possibility of option-year extensions. Interested vendors may submit capability statements to Contract Specialist Patricia Thai by 11:00 AM EST on November 10, 2026, referencing announcement number 36C24527Q0048. These submissions will be used solely to determine if the procurement will be conducted on a competitive basis. All work will be performed at the Baltimore VAMC, adhering to strict VA security, safety, and infection control requirements.
Facilities Support Services

POSTED

1 day ago

DEADLINE

in 12 days
View Details
NAICS: 423440
New
Federal
J072--JR/BP POTS AND PANS ROOM | WASHINGTON DC VAMC
Solicitation # 36C24527Q0043
The Department of Veterans Affairs is seeking a contractor for the emergency procurement, delivery, and factory assembly of commercial-grade kitchen equipment for the Nutrition and Food Services Pot and Pan Washing Room at the Washington DC VA Medical Center. This firm-fixed-price acquisition is driven by critical infection control and physical environment deficiencies identified during a June 2026 Joint Commission survey. The required equipment includes a custom Aerowerks two-compartment sink system with a drainboard, a Salvajor food waste disposer, and a Hobart TurboWash II pot scrubber. All equipment must be NSF listed, commercial grade, and compliant with Joint Commission, CMS Conditions of Participation, and FDA Food Code standards. The contractor is responsible for freight, uncrating, and delivery to the facility within 60 calendar days of award. A qualified Aerowerks technician must perform the on-site assembly within 14 days of delivery to preserve the manufacturer warranty. Strict safety and cleanliness protocols are in effect, including the requirement for hot work permits for welding and the immediate removal of all packaging and metal debris to prevent food service contamination. Payment will be issued via a single electronic invoice on a Net 30 basis following the COR's written acceptance of the installed and inspected equipment.
Other Commercial Equipment Merchant Wholesalers

POSTED

3 days ago

DEADLINE

in 6 days
View Details
NAICS: 238210
New
Federal
J061--INTENT TO SOLE SOURCE AWARD TO EATON CORP - BASE YEAR MAINTENANCE AND SERVICE CONTRACT FOR 8 UPS HERSHEL WOODY WILLIAMS VAMC
Solicitation # 36C24527Q0046
The Department of Veterans Affairs intends to award an open market sole source contract to Eaton Corporation (UEI: NP3NSFVMNUM3) for a one-year service and preventative maintenance agreement. The contract covers eight specific Eaton UPS systems located at the Hershel Woody Williams VA Medical Center in Huntington, West Virginia. The scope of work includes a Flex Plan consisting of two UPS and two battery preventive maintenance checks for all eight systems. This procurement is classified under NAICS code 238210 for Electrical Contractors and Other Wiring Installation Contractors and PSC J061 for the maintenance and repair of electric wire and power distribution equipment. The government is pursuing a sole source award because Eaton Corporation is the original equipment manufacturer and the only authorized provider of the proprietary service software, repair documentation, and materials required for 3-phase Eaton UPS products. As an ISO9001 certified supplier, Eaton does not certify or support third-party providers for these specific products. This notice is published in accordance with FAR 5.101(a) and FAR 12.102. Interested vendors may submit capability statements to Contracting Officer William Pratt by November 12, 2026, at 10:00 AM ET, referencing announcement number 36C24527Q0046 to determine if the requirement will be competed.
Electrical Contractors and Other Wiring Installation Contractors

POSTED

3 days ago

DEADLINE

in 14 days
View Details

Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS