Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, November 11 at 2:00 PM ET

Register Free →

This Sources Sought opportunity from Department Of Veterans Affairs was posted on October 26, 2023. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

J059-- Emergency Generator/ Switchgear Maintenance and Repair Base Plus Four (4) Option Year

Closed
36C26024Q0051Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 811310
New
Kubota M8200 Clutch Replacement
Solicitation # kubota-m8200-clutch-replacement
Management & Training Corporation (MTC) is soliciting bids for the clutch replacement of a Kubota M8200 tractor with front wheel assist, no cab or loader, located at the Earle C. Clements Job Corps Center in Morganfield, Kentucky. The scope of work requires the contractor to provide all transportation, labor, supervision, tools, and new manufacturer-specified parts to diagnose and repair the clutch assembly and power take-off (PTO) system. Key technical requirements include disassembling tractor components, replacing friction discs, bearings, oil seals, and O-rings, resurfacing the flywheel, and replacing hydraulic pipes and filters as necessary. The project is complete once the Facility Maintenance Department verifies proper clutch engagement and PTO operation under load. This is a small business set-aside opportunity under NAICS code 811310, open to various SBA-certified categories including VOSB, SDVOSB, WOSB, and HUBZone businesses. Proposals must be submitted via email to Angie Mahoney by November 3, 2026, and must include a lump sum bid sheet, a completed supplier packet with a W-9 and self-certification form, and proof of insurance. Award will be based on best value, considering the contractor's qualifications, experience, and the itemized cost breakdown. The contract is subject to Federal Acquisition Regulation (FAR) clauses regarding the Buy American Act, combating trafficking in persons, and Service Contract Labor Standards per Wage Determination No. 2015-4687 Revision 31 for Kentucky.
Earle C. Clements Job Corps Center

POSTED

about 8 hours ago

DEADLINE

in 5 days
NAICS: 811310
New
SLED
**Certified SB/DVBE Only** IFPQ Boiler Inspection, Maintenance, Repair, Testing, and Reporting in Los Angeles County
Solicitation # 07A6539
The California Department of Transportation (Caltrans) is soliciting price quotes for an Invitation for Price Quote (IFPQ 07A6539) to provide comprehensive boiler inspection, maintenance, repair, testing, and reporting services at the District 7 Office facility in Los Angeles, California. The scope of work includes annual and quarterly preventative maintenance for three Unilux water tube boilers and six boiler pumps, ensuring compliance with manufacturer standards, ASME Code, OSHA requirements, and South Coast Air Quality Management District standards. This is a set-aside solicitation exclusively for certified Small Business (SB), Microbusiness (MB), or Disabled Veteran Business Enterprise (DVBE) entities. The contract will be awarded to the responsible bidder offering the lowest price quote who meets all specifications. Key operational requirements include a 48-hour response time for routine service requests and a strict prohibition on subcontracting any portion of the work. The contractor must adhere to State General Prevailing Wage Rates for Los Angeles County and provide a payment bond for any service request exceeding 25,000 dollars. Required submission documents include a Price Quote Proposal, Bidder Certification Sheet, Non-Collusion Declaration, and certifications for California Civil Rights Laws and the Darfur Contracting Act. Invoicing is conducted monthly in arrears and must be accompanied by certified payroll records and DVBE utilization reports. The agreement is subject to a budget contingency clause, meaning it is enforceable only if sufficient funds are provided by the California State Legislature or the United States Government.
California Department of Transportation

POSTED

about 9 hours ago

DEADLINE

in 15 days
NAICS: 811310
New
SLED
RFP 07-135 Roseville Electric Utility – Air Compressor Maintenance
Solicitation # 07-135
The City of Roseville is soliciting proposals under RFP 07-135 for a consultant to provide comprehensive scheduled preventive and corrective maintenance for air compressors and auxiliary systems, including Ingersoll Rand equipment. The services will be performed at the Roseville Energy Park and Sunset Energy Center in California. The selected consultant will be responsible for providing all necessary labor, technical expertise, specialized tooling, and materials. This is a prevailing wage project with an initial contract duration of five years, estimated to commence in April or May. Proposals must be submitted by December 16, 2026, via email to the City Clerk or through physical delivery in a sealed container with the required Attachment H label. The award will be based on a formal evaluation panel process considering the firm's experience and qualifications (25 points), the proposed project plan (35 points), and cost (40 points), with potential interviews for top candidates. Requirements for the successful bidder include obtaining a City of Roseville business license, providing 100% faithful performance and labor and materials bonds, and maintaining specific insurance policies. Consultants must also disclose any conflicts of interest and adhere to the Levine Act regarding political contributions.
City of Roseville

POSTED

about 14 hours ago

DEADLINE

in about 2 months

General Info

NAICS

811310 - Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance

Place of Performance

Mann-Grandstaff VA Medical Center 4815 N. Assembly Street, Spokane, WA, 99205, USA

Set-Aside

NONE

Documents

1

36C26024Q0051 - Emergency Generator/Switchgear Maintenance and Repair

DOCX, Low prioritysources-sought
Low

AI Contract Breakdown

Uniform Contract Format

Contract not broken down yet

CLEATUS splits the solicitation into Uniform Contract Format (UCF) sections: scope, pricing, deliverables, and evaluation criteria.

Timeline

PhaseClosed
Posted

Sources Sought

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Veterans Affairs → 260-NETWORK Contract Office 20 (36C260)
Contacts1 person available
OfficeVANCOUVER, WA, 98661, USA
Office AddressVANCOUVER, WA, 98661, USA
Contacts
Quyen MaiContract Specialist

Full Description

Show more
THIS IS A SOURCES SOUGHT NOTICE ONLY. This is not a solicitation for bids, proposals, proposal abstracts, or quotations. The purpose of this Sources Sought Notice is to obtain information regarding the availability and capability of all qualified sources to perform a potential requirement. The responses received from interested contractors will assist the Government in determining the appropriate acquisition method. The Department of Veterans Affairs (VA), Network Contracting Office (NCO) 20, is conducting market research to identify potential sources which can provide the following services: Emergency Generator Maintenance in support of the Mann-Grandstaff VA Medical Center at the Spokane, WA Campus. The Contractor shall furnish all necessary parts, materials, labor, tools and equipment, and travel as necessary to VAMC Spokane hospital campus (travel to and from VAMC Spokane for all service visits shall be at no additional charge to VAMC Spokane) to provide on-site annual maintenance, three-year maintenance, maintenance repair, emergency repairs, Fuel Polisher and Day Tank maintenance, Switchgear testing along with testing and reporting. All replacement parts must be OEM Caterpillar parts, and all work is performed ONLY by Caterpillar, Schweitzer, and Eaton certified technicians with current certifications. The Contractor upon receiving notification of repairs needed to be done must respond within 48 hours to site needing the work and have equipment repaired unless a part is needed to be ordered. The emergency generators and switchgear equipment are specialized components that require OEM specialized personnel that have the proper programming access with highly technical skillset to conduct maintenance and repairs needed. This requirement is a Base year plus four (4) Option Years contract. 52.217-8 will be incorporated into the procurement for a six-month additional option (if necessary). All services and repair work must be conducted by OEM specialized personnel and Caterpillar, Schweitzer, and Eaton certified technicians. In response to this Sources Sought please submit validation of OEM Caterpillar, Schweitzer, and Eaton-certified technicians. Government will consider a single source procurement if this sources sought shows only one vendor is capable to provide the OEM Caterpillar, Schweitzer, and Eaton-certified technicians. Project Location This service needed is located at the Spokane, WA of the Mann-Grandstaff VA Medical Center. The address is: Mann-Grandstaff Veteran Affairs Medical Center 4815 N. Assembly Street Spokane, Washington 99205 Contract Specifications (Draft Version) Generator Equipment: MANUFACTURE Model Serial # Site Name QTY Caterpillar 3512C SBG00862 VA Gen#26599 1 Caterpillar 3512C SBG00880 VA Gen#26600 1 Caterpillar 3512C SBG00881 VA Gen#26601 1 Associated Switchgear: Make Model Serial # Voltage Site Name ISO Switchgear SWG36310 480 VA Gen#26599 ISO Switchgear SWG36310 480 VA Gen#26600 ISO Switchgear SWG36310 480 VA Gen#26601 MANUFACTURE Model Part Number Site Name QTY SCHWEITZER 547 GEN INTERCONNECTION RELAY 05470X155XXX2XX Generator Control Section Bldg. 38& 39 3 SCHWEITZER 700G GEN PROTECTIVE RELAY 0700G11A0X0X76850200 Generator Control Section Bldg. 38& 39 3 SCHWEITZER 751A FEEDER PROTECTION RELAY 751A01ABB0X0X850200 Generator Control Section Bldg. 38& 39 3 SCHWEITZER 751A FEEDER PROTECTION RELAY 751A01ABB0X0X850200 Generator Control Section Bldg. 38& 39 1 On-site Annual Generator Maintenance The Contractor shall provide only by Caterpillar, Schweitzer, and Eaton certified technicians with current certifications are to work on said equipment. Technicians of skilled personnel with the technical qualifications to perform maintenance, repair services and testing on the highly sophisticated all VA Spokane generators, Switchgear and associated equipment listed below. The Contractor shall ensure service is provided by a Caterpillar, Schweitzer, and Eaton Power certified technicians. Certified means that they are trained in all aspects of the systems with the required access to the Eaton power program access and privileges to effect program changes and troubleshooting from electrical specification and performance to fault-finding and health and safety practices. Certified Technician shall be a certified and approved by the Caterpillar generator manufacturer. The Contractor shall perform a load bank test event for each unit for a duration of 1 hour under 100 percent load, to include a 15-minute warm-up period and a 15-minute cool down period. Maintenance shall be performed once a year at internals of approximately twelve (12) months; exact date shall be determined by VAMC Spokane Engineering Service (ES). Switchgear Service: The baseline level of maintenance that shall be performed on the three switchgear assemblies and controls shall comply with the 2016 edition of NFPA 70B. VA recognizes that NFPA 70B covers all facets of electrical maintenance for clarification purposes, the contractor is responsible to perform maintenance on the following items within the switchgear and its controls: Circuit breakers and trip units, Busing, Generator and switchgear controls, Enclosure housings, Filters, Current transformers, potential transformers, control power transformers, Protective relays and Lighting internal of the switchgear housing. Switchgear Service Schweitzer components. Contractor shall be responsible to ensure the proper operation of all switchgear actions necessary to support proper operation of the generators and load bank. Contractor shall ensure a Schweitzer Factory Authorized representative completes all periodic testing, maintenance, and calibration of Schweitzer components. Bench testing of circuit breakers is not required as part of this service, however, testing of Schweitzer protective relays and trip units is required. Schweitzer components include SEL-351A, SEL-547, SEL-700G, SEL-751A, and these shall be tested, calibrated, and maintained on an annual schedule. The VA recognizes that NFPA 70B is a minimum standard developed by NFPA and that to support the site s critical mission the level of maintenance required to support the equipment needs to be increased. The contractor shall conduct the following additional services to provide an increase service level for the generator sets: The Contractor shall annually demonstrate the switchgears ability to perform all the designed sequences of operation, excluding Programmable Logic Controllers (PLC) failures. The Contractor shall replace control indicator lights on an as needed basis without need for cost approval from VA. After completing repair-oriented and repair-preventative services under this contract, the Contractor shall provide a detailed written report containing information on the work performed, parts utilized, suspected causes of component failures, and further recommendations to enhance equipment readiness status to the Facility Manager. The Contractor shall send a copy of this report the facility manager NLT 10 days from repair of system. A report provided by the Schweitzer Factory Authorized representative shall be included as an addendum to this report. Work sequencing: The Contractor shall perform generator inspections and or maintenance one generator at time. Two generators shall remain fully functional and capable of operating in case of emergency always. Generator Maintenance shall be done during regular working hours of 6:30 am through 4:00pm, Monday Friday, except weekends and Federal Holidays. All repairs are performed during these hours of coverage unless requested or approved by the VA Point of Contact (POC) designee as outlined in emergency work. Upon notification of work, required Contractor shall respond by 48 hours to perform scheduled annual maintenance or repair equipment, except as noted in the emergency call back. Three-Year Maintenance and Inspection Services: The Contractor shall provide Caterpillar, Schweitzer and Eaton certified skilled personnel with the technical qualifications to perform maintenance, repair services, testing, and inspections on all VA Spokane generators and associated equipment listed below. All replacement parts are OEM Caterpillar parts, and all work is performed by Caterpillar, Schweitzer, and Eaton certified technicians. Perform and complete On-site Annual Generator Maintenance (6. Specific Tasks), to include all items described in the VAMC Spokane Annual Generator Requirement checklist. Generator Check for moisture, dust, oils, greases, and debris on main stator windings, exciter, and PMG. Clean as needed. Cooling System - Drain, clean and flush. Replace thermostat(s). Refill with coolant solution and conditioner. Hoses and Belts Replace all heater hoses coolant pipe seals and fan and alternator belts Batteries - Battery replacement, replace the 4 engine starting batteries with Caterpillar maintenance free batteries. Fuel Sample- Fuel sample, required by health care facilities. Take fuel oil samples and analyze. Turbocharger - Inspect/Check; Inspect for proper operation. Check the end play and radial clearance on the turbine wheel and shaft. Document readings. Engine - Perform a complete engine adjustment and tune-up; Refer to the Service Manual. Generator Bearing Inspect generator bearing and bracket. Lubricate generator bearing; refer to Generator Service Manual. Load bank test, includes performing a 4-hour load bank test using the hospitals on site load bank and documenting the engine vitals every 15 minutes. Oil Change, replace the engine lube oil filters, primary and secondary fuel filters, and obtain lube oil sample. On-Site Maintenance Repairs: The Contractor shall respond to an equipment failure within four (4) hours or less of a call by VAMC Spokane for unscheduled or emergency on-site service. Unscheduled service calls shall be invoiced on hourly basses in accordance with the Quotation Form. The Contractor acknowledges that failure to respond to an emergency call could affect patient care and hospital operations. The Contractor shall agree to make his best effort to respond to emergency calls for Generator service as quickly as possible. VAMC Spokane shall be provided with unlimited telephone support, 24 hours a day, 7 days a week, including weekends and holidays. Any non-consumable or non-warranty parts used during a service visit shall be pre-approved by the VA POC and billed using the Contractor s current price list at the time of usage. The cost to the VAMC Spokane of new material shall be that actual charge the Contractor as substantiated by vendor s invoices plus the percentage bid. The Contractor shall maintain sufficient parts and supplies to service and repair the VAMC Spokane Generators. Travel to and from VAMC Spokane for all service visits shall be at no additional charge to VAMC Spokane. Expenses incurred to repair items that have been warn in a manner consistent with their normal usage shall be repaired at no additional charge. Service reports for each scheduled and un-scheduled site visit shall be prepared by the service engineer and provided to VAMC Spokane on the same day as the service visit. The service report shall describe all work performed during the site visit and any parts used during the preventative and/or emergency maintenance service. Submit a written report to VAMC, and advice of any further work required. Annual Service & Maintenance Simplex Fuel Polisher & Day Tank Maintenance: The Contractor shall provide all parts and labor to replace the filters on the Generator Fuel Polisher Simplex Smart Filter units once a year. Conduct an operational check after all filters elements are replaced. Before departing ensure fuel polisher system is restored to normal operations run at least 800 gallons through the filter system to ensure operations is 100 percent satisfactory. OEM Parts required: 1 EA - P/N 211338 - - - - - Filter 1 EA - P/N None - - - - - - - Pre-Filter RVFS-1 Separator Element 10 micron(SP-15405) 1 EA - P/N 27000406 - - - RVFS-1 Separator Element 05 micron 1 EA - P/N 27000404 - - - RVFS-1 Coalesce Element 05 micron 1 EA P/N None - - - - - - - - Final Filter RVFS-1, Separator Element 01 micron (FP-14601) Day Tanks / Three (3) Total: Drain water and sediment from each tank. Remove and inspect port cover from the Day Tank. Examine the interior of the Day Tank. Using and inspection lamp examine all Day Tank components. With the tank drained test all sending units for proper operation. Install a new inspection port gasket and replace the inspection port cover. Press the test fill push button and observe pump and motor performance. Inspect pump/motor alignment and wear. Inspect pump for leaks. Retighten hose clamps at pump/hose connections. Retighten the pump bracket, motor bracket, and pump/motor coupler hardware. Inspect all plumbing connections for leaks. Test all options and fuel level alarms for proper operation. Retighten all electrical connections. Items of Work: For the unit prices bid, the Contractor shall provide all necessary labor, material, and equipment to provide VAMC Spokane with competent service and preventative maintenance program, testing support and consulting services to maintain the Generators. Routine Service & Maintenance Annual Site Visits: The Contractor shall provide one (1) visit to each generator to provide yearly service and preventative maintenance, testing support and consulting services to maintain the VAMC Spokane Generators. Three (3) Year Service, Maintenance & Inspections: The Contractor shall provide one (1) visit to each generator to provide 3 yearly service and preventative maintenance, testing support and consulting services to maintain the VAMC Spokane Generators. Servicing of Corrective Maintenance of Generators: The Contractor shall provide at least one (1) man and one (1) fully equipped vehicle to replace or repair defective components of the Generators. Servicing for Emergency Corrective Maintenance of Generators: The Contractor shall provide one (1) man and one (1) fully equipped vehicle to respond to emergency calls from the VAMC Spokane to trouble shoot and/or replace or repair defective components of the Generators. This shall be based upon daily overtime hours and shall be based upon Saturday, Sunday and Holiday overtime working hours. The Contractor shall provide additional manpower as required to trouble shoot and / or replace or repair defective components of the Generators. In general, this item will be paid for when one (1) man working alone cannot safely or adequately perform the required emergency work. This shall be based upon regular working hours, overtime hours and Saturday, Sunday and Holiday overtime working hours. Materials: The Contractor shall provide materials required to replace and / or repair material found to be defective. The cost to VAMC Spokane of new material shall be that charged the Contractor as substantiated by vendors invoices. Non-Consumable Replacement Parts: Non-consumable replacement parts furnished shall be essentially the standard product of the original generator manufacturer. Any substitution for original replacement parts shall be with an equivalent or a better product. The replacement part may be acceptable if it meets or exceeds all the requirements of the original part and that such substitute will not materially alter the original basic design. Changes in Design and /or Substitution of Replacement Parts: If, during replacement and/or repair of defective parts, it is found expedient by the Contractor to modify or change the design of any part of the generators, including the equipment or any part thereof, completely detailed and checked working drawings showing the proposed changes are to be submitted to the Owner for review and approval. Any permitted modification or change of design as set forth above is to be at the sole discretion of the Owner. Approval of such changes does not release the Contractor from his obligation or guarantees, nor are any of the conditions of the Agreement abrogated thereby. Any additional costs, including redesign costs to this Contract resulting from these changes, are to be borne by the Contractor. Replacement Parts Guarantee: All replacement parts, materials, and workmanship furnished shall be guaranteed by the Contractor to perform the services required of them, to the full expectations and/or satisfaction of the Owner in accordance with recommendations from original equipment manufacturer, for a period of one (1) year from the date of installation and acceptance. The Contractor service shall ensure that the equipment functions in conformance with the manufacturer s specifications. Maintenance and repair procedures shall be in accordance with the manufacturer s specifications. Reporting Requirements The Contractor upon receiving notification of repairs needed to be done must respond within 48 hours to site needing the work and have equipment repaired unless a part is needed to be order. The Contractor MUST report to Engineering Service Boiler Plant Bldg. 2 to log in, this check-in is mandatory. When the service is completed, the Field Service Engineer (FSE) must document services rendered on a legible Equipment Service Report(s) (ESR). The FSE must be required to log out with Engineering Service Boiler Plant and submit the ESR(s) to the VA POC. All ESRs must be submitted to the VA POC for an authorization/acceptance signature. If the VA POC is unavailable, a signed, authorized copy of the ESR will be sent to the VA POC or VA Budget Technician after the work can be reviewed (if requested or noted on the ESR). Potential candidates having the capabilities necessary to provide the above stated services are invited to respond to this Sources Sought Notice via e-mail to Quyen Mai at contact@example.gov no later than 09 November 2023 by 12:00 PM Eastern Time. No telephone inquiries will be accepted. RESPONSES SHOULD INCLUDE THE FOLLOWING INFORMATION: company name, address, business size; SAM UEI, point of contact name, phone number, and e-mail address; capability statement and if the services are available on a current GSA Federal Supply Schedule contract. All services and repair work must be conducted by OEM Caterpillar, Schweitzer, and Eaton Power-certified technicians. - In response to this Sources Sought, submit validation OEM Caterpillar, Schweitzer, and Eaton Power-certified technicians and the required response time within 48 hours upon receiving notification to site needing the work and have equipment repaired. NAICS Code 811310 is applicable to determine business size standard of $12.5 Million. Any questions or concerns may also be directed to Quyen Mai via e-mail. Disclaimer and Important Notes: This Sources Sought Notice does not obligate the Government to award a contract or otherwise pay for the information provided in response. The Government reserves the right to use information provided by respondents for any purpose deemed necessary and legally appropriate. The Government will treat any information received as proprietary and will not share such information with other companies. Any organization responding to this Sources Sought Notice should ensure that its response is complete and sufficiently detailed to allow the Government to determine the organization's qualifications to perform the work. Respondents are advised that the Government is under no obligation to acknowledge receipt of the information received or provide feedback to respondents with respect to any information submitted. The Government may or may not issue a solicitation as a result of this announcement. There is no solicitation available at this time. Government may conduct a single source procurement if only one vendor is identified to meet the requirement.

More opportunities from Department Of Veterans Affairs → 260-NETWORK Contract Office 20 (36C260)

Same awarding agency

NAICS: 238220
New
Federal
J041--White City B249 SE HVAC Repair
Solicitation # 36C26027Q0102
Solicitation 36C26027Q0102 is a total set-aside for certified Service-Disabled Veteran-Owned Small Businesses (SDVOSB) issued by the Department of Veterans Affairs. The contract requires the repair of a Mitsubishi R-410A comfort-cooling system (Serial 07W0090) located on the southeast side of Building B249 at the VA Southern Oregon Rehabilitation Center and Clinics in White City, Oregon. The scope of work includes leak detection, brazing repairs with nitrogen purge, refrigerant recovery, evacuation to less than 500 microns, and recharging the system to nameplate requirements. The contractor must provide a detailed service report documenting the root cause, repair actions, and compliance with EPA Section 608 and VHA ICRA/PCRA controls for occupied healthcare facilities. The period of performance is 30 calendar days from the Notice to Proceed. Award will be granted to the responsible offeror whose proposal is most advantageous to the government, considering price and other specified factors. Key regulatory requirements include adherence to OSHA 29 CFR 1910.147 for lockout/tagout and 29 CFR 1910.333 for electrical safety. Payments will be processed via Electronic Funds Transfer, and invoices must be submitted electronically through the Tungsten Network. Offerors must provide their Unique Entity Identifier and maintain firm pricing for 60 calendar days from the response deadline of November 10, 2026.
Plumbing, Heating, and Air-Conditioning Contractors

POSTED

1 day ago

DEADLINE

in 12 days
View Details
NAICS: 334513
New
Federal
Boiler Plant O2 Sensor Replacement
Solicitation # 36C26027Q0101
The Department of Veterans Affairs, through the Network Contract Office 20, is conducting market research via a Sources Sought Notice for a firm-fixed price service contract to perform inspection, testing, maintenance, and repair of three model 6888 Rosemount flue gas analyzers. The work will be performed at the VA Southern Oregon Rehabilitation Center and Clinics in White City, Oregon. The primary scope involves replacing internal O2 analyzer components using original equipment manufacturer parts, specifically 18 inch standard cells, 18 inch heater strut assemblies, Hastelloy with Vee Deflectors for service up to 1300 degrees Fahrenheit, and new flange gaskets. The period of performance is six months, with on-site work required during core hours of 7:00 AM to 4:00 PM, Monday through Friday. This opportunity is designated as a total Small Business Set Aside under NAICS code 334513, with a size standard of no more than 750 employees. Qualified sources, including SDVOSB and VOSB entities, must provide company details, SAM.gov UEI numbers, and proof of manufacturer authorization if they are not the OEM. Contractors must employ qualified personnel, maintain general third-party liability insurance per FAR 52.228-5, and adhere to NEC, OSHA, and JCAHO standards. Deliverables include written daily reports to the Deputy Chief Facilities Management and testing documentation provided to the Contracting Officer's Representative. Interested parties are requested to provide a courtesy quote and capability statement to assist the government in evaluating price reasonableness and market availability.
Instruments and Related Products Manufacturing for Measuring, Displaying, and Controlling Industrial Process Variables

POSTED

3 days ago

DEADLINE

in 4 days
View Details
NAICS: 325998
New
Federal
Microbiological media purchase order for Clinical Microbiology laboratory.
Solicitation # 36C26027Q0104
The Department of Veterans Affairs Network Contracting Office 20 is seeking sources for a microbiology testing media purchase order to support the Seattle Division of the VA Puget Sound Medical Center. This requirement covers a wide range of critical supplies for identifying pathogenic organisms in veteran patients, including long shelf-life products like Oxidase and Indole, perishable selective agar, biochemical test kits, and ATCC organisms mandated by the College of American Pathologists for quality control. The contract is structured with a base year running from February 1, 2027, to January 31, 2028, followed by four subsequent one-year option periods ending January 31, 2032. Deliveries are to be made to the Microbiology Lab in Seattle, with weekly shipments typically scheduled for Tuesdays and individual requests fulfilled as available. Due to the perishable nature of many items, the vendor must provide tracking information, and the cost of next-day delivery for all perishable goods must be included in the individual item price. All temperature-liable products require immediate refrigeration upon delivery. Invoicing is processed through the Austin Automated Payment System in Texas, and the vendor must provide SDS sheets for all media upon request. This sources-sought notice specifically looks for capable sources, including qualified SDVOSB/VOSB entities, with a response deadline of November 10, 2026.
All Other Miscellaneous Chemical Product and Preparation Manufacturing

POSTED

3 days ago

DEADLINE

in 12 days
View Details
NAICS: 238220
New
Federal
Z1DA--CON-NRM-668-22-106 Correct Domestic Water System
Solicitation # 36C26027R0014
Solicitation 36C26027R0014 is a negotiated request for proposals for the Department of Veterans Affairs to correct domestic water system deficiencies in Buildings 1 and 12 at the Mann-Grandstaff VA Medical Center in Spokane, Washington. The project is 100% set aside for Service-Disabled Veteran-Owned Small Businesses under NAICS 238220, with an estimated contract magnitude between $1 million and $2 million. The primary objective is to modify hot and cold potable water distribution systems to comply with VHA Directive 1061 for the prevention of scald injuries and Health Care-Associated Legionella Disease. The scope includes all labor, materials, and equipment, with a specific requirement to flush potable water dispensing fixtures twice weekly from installation until final acceptance. The period of performance is 275 calendar days from the Notice to Proceed. The government will utilize a Best Value tradeoff process for award, prioritizing technical experience and past performance over cost. Technical evaluations will favor offerors with demonstrated experience in phasing and Infection Control Risk Assessment (ICRA) within 24-hour operational emergency rooms. Proposals must be submitted in three separate volumes—Technical, Past Performance, and Price—by November 23, 2026. Awardees must provide performance and payment bonds, adhere to Davis-Bacon Act wage determinations, and comply with Buy American requirements. Additionally, the contractor must maintain strict confidentiality regarding sensitive information and provide a one-year warranty on all materials and installation.
Plumbing, Heating, and Air-Conditioning Contractors

POSTED

3 days ago

DEADLINE

in about 1 month
View Details

Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS