J061--Emergency Generator Service

Active
36C24121Q0718Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

AI Contract Overview

Show more

The Department of Veterans Affairs’ Networking Contracting Office in Newington, CT, plans to enter into a sole source contract with Milton CAT Corporation for the inspection, preventative maintenance, and repair of emergency generators at the VA Medical Center in Augusta, Maine. This contract, effective for one year with four optional annual renewals, encompasses semi-annual and annual maintenance checks, 24-hour emergency callback services, and necessary repairs to ensure the generators’ reliability. The scope includes providing all equipment, fluids, tools, and skilled labor to maintain various emergency generator models, primarily Caterpillar units, which are critical for hospital operations and must be maintained by factory-certified technicians to preserve warranties and ensure operational integrity. The contract requires rigorous adherence to manufacturer specifications, safety regulations, and applicable codes such as the National Electrical Code and NFPA standards. Preventative maintenance tasks involve detailed inspections and servicing of engine components, batteries, fuel systems, and exhausts with documented reports submitted promptly after each service. Emergency repairs must be responded to within a specified timeframe and completed as quickly as possible. The contractor is responsible for supplying all materials and maintaining a local inventory of parts for normal maintenance and emergencies, while the VA funds parts over $500, with the contractor providing labor free of charge. All work must be coordinated with the VA’s staff, comply with safety protocols, and maintain continuous generator readiness to support the medical center’s critical infrastructure.

General Info

One-year sole source contract with Milton CAT for emergency generator maintenance and repairs at VA Maine.

NAICS

811310 - Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance

Place of Performance

ME

Set-Aside

NONE

Documents

1

Emergency Generator Service - 36C24121Q0718

DOCX, High priority: read this first7 pages · sow
High

AI Contract Breakdown

Uniform Contract Format

Contract not broken down yet

CLEATUS splits the solicitation into Uniform Contract Format (UCF) sections: scope, pricing, deliverables, and evaluation criteria.

Timeline

1 update
Posted

special-notice

Notice updated

Notice type changed from Contract Update to Special Notice. The notice description changed.

Ready to pursue this opportunity?

Get full access to track this contract, build proposals with AI assistance, and manage your pipeline.

Organization & Contact Information

Show more
AgencyDepartment Of Veterans Affairs → 241-NETWORK Contract Office 01 (36C241)
Contacts1 person available
OfficeTOGUS, ME, 04330, USA
Office AddressTOGUS, ME, 04330, USA
Contacts
Kenya MitchellContract Specialist

Full Description

Show more
The Department of Veterans Affairs, Networking Contracting Office (NCO 01) located in Newington, CT intends to enter into a sole source procurement, pursuant to the authority of FAR 6.302-1, with Milton CAT Corporation, for the following requirement: STATEMENT OF WORK (SOW) Inspection, Preventative Maintenance, and Repair of Emergency Generators INTRODUCTION The work includes but is not limited to: provide all equipment, fluids, tools, labor, and to perform regular and periodic examination as stated below, semi-annual and annual preventative, 24 hour emergency call back diagnosis and repair of the emergency generator systems at the VA Medical Center in Augusta, ME located at 1 VA Center. The proposed term of the service is one year from the date of the award. There will be four additional renewal option years to be re-evaluated and awarded annually. DEFINITIONS/ACRONYMS Engineer (ing) - Supervisor or designee. CO - Contracting Officer COR - Contracting Officer's Representative. WHEN Hours- Weekends, Holidays, Evenings, and Nights. Anytime outside of Normal Business Hours (Monday-Friday 7:00am-4:30pm) ESR - Engineering Service Report. A documentation of the services rendered for each incidence of work performance under the terms and conditions of the contract. Authorization Signature - COR signature; indicates work status is accepted as stated in ESR. VAMC - Department of Veterans Affairs Medical Center. PM- Preventive Maintenance EQUIPMENT TABLE Make: Model: S/N: Location: Magnum Power XQ570 XQ570HME500131 Bangor Magnum Power MMG330 1409605 Bldg 244 Generac MDG250 3002791927 Bldg 202-200 Generac MDG150 3002791925 Bldg 202-200 Generac MDG100 3002876808 Bldg 202-200 Ingersoll Rand G40 4FVCBAA78440089 Bldg 229 Caterpillar C9 C9E01997 Bldg 244 (*) Caterpillar 3459 CCB00984 Bldg 200-195 (*) Caterpillar 3412 81z08706 Bldg 200-195 (*) Caterpillar XQ570 XQ570LME500127 Lewiston Caterpillar MMG330 3002791927 Bldg 249 Caterpillar C13 T3200659 Bldg 210 (*) Caterpillar C27 2A300654 Bldg 244 (*) Caterpillar 3406 4ZR01263 Bldg 238 (*) (*) - Critical Joint Commission Generators that include 2 replacement batteries/unit in Second Yr Check Mobile Generators are subject to change location SCOPE This project includes the following tasks: 4.1 Task 1 Scheduled preventative maintenance: Provide regularly scheduled annual and semi-annual preventative maintenance services for all the emergency generator systems at the Medical Center noted in the equipment table. Service includes the following at the minimum or Manufacture requirements whichever is greater. SEMI-ANNUAL CHECK (ENGINE NOT RUNNING) Conduct visual check around the generator. Check the battery s liquids specific gravity, do battery load test, top up\fill if necessary. Clean battery terminals and lugs. Check all V and fan belts to make sure there are no hair line cracks on the belts, replace if cracked or worn. Check and adjust tension on all V and fan belts. Check coolant level and top up\fill if necessary. Check specific gravity of coolant. Replenish as necessary to maintain manufacturers recommended level and specific gravity of coolant additive. Check operation and components of water jacket heating system. Test fuel day tanks for water. Record water levels in tanks. Drain condensate from exhaust condensate trap. Clean air filter element. Inspect all fuel, oil, and water piping for secure mounting. Inspect exhaust piping and muffler insulation. Inspect crankcase breather tube. Check all control panel indication LED s. SEMI-ANNUAL CHECK (ENGINE RUNNING) Turn off the generator circuit breaker and run the generator unloaded for 15 minutes. Check the generator for unusual conditions, such as: excessive vibration, excessive black or white smoke. The following indicators on the control panel also need to be checked and verified while the generator is running: fuel level, oil pressure, water temperature, rpm, voltage, and frequency. With the engine running and the generator circuit breaker open: Jumper water temperature switch Jumper oil pressure switch Jumper coolant low-level switch Press emergency stop push button. Each time the switch is jumped or the emergency stop button is pressed the engine should stop and the corresponding failure lamp should illuminate. Reset the shut-down mechanisms after each test. Read and record verify all engine and alternator indicators. Check exhaust for excessive black or white smoke. (See manufacture s manual) Check turbocharger for vibrations, check for any abnormal noise during operation. Check generator bearing for noise and overheating. Check exhaust manifold, muffler, and piping for leaks and secure mountings. Check fuel day tank for overheating. Check exhaust backpressure at the Diesel particle filter (Dpf.), if above 24 Inches H20 / 6 kPa, Dpf filters to be removed and cleaned. Or in accordance with the manufacturer s recommendations. SEMI-ANNUAL CHECK (ENGINE STOPPED AFTER RUNNING) Inspect engine water, fuel, and oil systems for leaks while engine is hot. Fill out maintenance checklist and report deficiencies. Confirm that circuit breaker is in closed position, and generator is set in automatic. SEMI-ANNUAL CHECK (ENGINE NOT RUNNING) Change fuel and air filters every 250hrs or once a year whichever is sooner Change coolant filters every 250hrs or once a year whichever is sooner Inspect battery charging Alternator and V belt. Inspect engine and generator wiring harness for wear and damages. Inspect supports and spring isolators for soundness and stability. Inspect unit thoroughly for loose fasteners. Clean radiator air passages and exhaust air ducts. Clean intake louvers and ducts. Inspect unit for corrosion. Remove any corrosion, prime and paint. Inspect fan drive idler pivot arm assembly and shock absorber. Inspect Belt driven fan hub. Take fuel oil samples, analyze and report composition and cleanliness. ANNUAL CHECK (ENGINE RUNNING) Perform complete semi-annual Engine running schedule (Section 2). ANNUAL CHECK (ENGINE STOPPED AFTER RUNNING). Perform complete semi-annual Engine stopped after running schedule. (Section 3). Change crankcase oil and filters every 250 hours or once a year, whichever is sooner. Fill out maintenance checklist and report deficiencies. Confirm that circuit breaker is in closed position, and generator is set in automatic. OUT YEAR CHECKS Second Year Checks: Inspect Turbocharger: Inspection to include bearings, seals, exhausts, and air impellers. Change all gasket and seals. Inspect Rotating rectifier: Inspect and clean rotating rectifier per manufacturer s recommendations. If replacement is warranted, provide a written recommendation to the COR for action to include all material and labor. Replace batteries: Replace batteries with minimum Caterpillar Deep Cell batteries per manufacturer s recommendations. Provide two (2) batteries for each generator. Replace cooling system temperature regulators with seals. Task 2 Repairs and Emergency Call Back Service: Contractor shall have technician on site within two (2) hour, during normal business hours and three (3) hours, during WHEN hours of request by telephone or otherwise from contacting officer, Chief Engineer and/or designees for emergency services. Response will be in the event of a shut down or emergency trouble developed between regularly scheduled maintenance services. Overtime emergency call back service shall be limited to minor adjustments and repairs required to protect and provide immediate safety of the equipment and persons in and about the generators. The contractor shall be responsible to make all repairs and adjustments necessary. Repairs are defined as unscheduled work required to (1) prevent a breakdown or malfunction of an item of equipment; (2) put a system or a subsystem back in service after a breakdown or malfunction. The emergency generator systems of the medical center must remain operational 24/7. Alternative measures for providing equivalent emergency power during repairs are the responsibility of the VA. Repairs shall be completed within 24 hours after the need for repair has been identified by the contractor or by the Government. All repairs shall be in accordance with the equipment manufacturer s requirements and\or applicable laws, regulations, codes, etc. An extension may be granted at the discretion of the COR on a case by case basis. Each request for an extension must include and explanation for the delay, and estimated time of completion, and evidence to clearly show that the contractor has made every effort to repair the system as timely as possible. The Contractor shall furnish all supplies, materials, and equipment to perform regularly scheduled service, emergent service, and repairs. All parts and materials shall be of the original manufacturer s design and specification, or equal thereto. The Contractor shall have and maintain on hand locally a supply of spare parts enough for normal maintenance and expedient emergency repairs of the generators. Parts greater than $500 to be VA funded but installation provided free of charge by contractor. Space is not available for storage of equipment or materials. If needed the Contractor should make arrangements for storage as part of this contract. PERFORMANCE REQUIREMENTS The Contractor, under this Scope of Work (SOW), will be responsible for all supervision, labor, tools, lubricants, cleaning products, and manufacturer replacement parts and equipment required to carry out all services as outlined in this SOW. The medical center is considered a critical facility; therefore, all emergency generator equipment shall be kept in first class condition and proper working order 24/7. The Contractor will be required to evaluate the existing equipment and provide the COR with a proposed maintenance schedule in advance of service. Contractor must submit to the COR for review, work sheet/checklist that will be used for performing and documenting maintenance service. All personnel working in the vicinity shall wear and /or use safety protection equipment and exercise the appropriate cautions while all work is performed. Any questions or injuries shall be brought to the attention of the COR, and Safety Manager or Safety Officer. Material data sheets (MDS)shall be provided by the contactor for all HAZMAT materials. Copies will be provided to the COR for approval. No materials will be allowed to be brought on site until they have been submitted and approved by the COR in advance. Preventive maintenance for Standby generator sets to be performed by a technician or mechanic, who is manufacturer certified to work on Caterpillar and other Diesel manufactured emergency generators as listed above. All off site calibration of generator components to be performed by an authorized Caterpillar repair location, a calibration certificate for each calibrated component must be issued. Perform all annual preventive maintenance procedures prior to beginning out-year cycles. COR must immediately be made aware of any condition discovered that could result in equipment failure. Testing and inspection summary report shall be submitted to the COR within three days of completing all work. If any discrepancies are found with the generator system that are not covered under this scope of work, then the contractor must provide the following: Detailed report noting the discrepancy found. Bill of Materials (BOM) to include component name, quantity, part #, and assumption of price for any repair material required and material lead time. All work shall be completed during normal business hours in conjunction with the medical center regularly scheduled monthly generator testing, unless called back for emergency service outside of normal business hours. Emergency call back services shall be assumed to be completed during WHEN hours. All travel costs associated with performance of this contract are the responsibility of the Contractor and are provided at no additional cost to the government as part of this contract. Travel costs are defined but not limited to time and vehicle costs for personnel in travel to and from job site for all duties outlined in this specification, normal shipping charges on any parts or materials covered by this contract, costs associated with the normal shipping of parts or equipment out for repair that are covered under this contract, etc. The services shall be completed in accordance with the latest National Electrical Code (NEC), and National Fire Protection Association (NFPA) standard, VA Standards and policies, and local and city codes. In the event there is conflict between any of the standards/codes, the more stringent standard/code shall apply. Clarification for conflicts must be requested in advance of the service rendered. Contractor shall comply in accordance with all OSHA Safety Guidelines. Upon arrival at the medical center, the Contractor shall check in with the maintenance scheduler, COR or designee. Contractor shall sign in and out in engineering during normal business hours. During WHEN hours the Contractor shall sign in and out at the Boiler Plant. While on property the contractor shall always display an appropriate contractor badge . DELIVERABLES Submittal of proposed maintenance schedule of activities for review and approval by the COR. Submittal of proposed equipment and materials to be used on site for review and approval by the COR. Submittal of Contractor safety plan and lock\out tag\out plan. Submittal of material Data Sheets (MDS) shall be provided by the contactor for all chemicals proposed to be brought to the medical center. Chemicals must be approved before they can be located on property. Submittal of all maintenance reports. Must be submitted within 3 days of service completion date. Reports should include at a minimum: Name and contact information for contractor. Name of employee performing the work. Date of work performed, and hours spent. Description of the work performed including PMI s and equipment worked on. Detailed report noting any deficiencies found. Signature of employee that performed work as well as the COR. Bill of Materials (BOM) to include component name, quantity, part #, and assumption of price for any repair material required and material lead time. The NAICS code for this requirement is 811310 with a small business size standard of $8 million. VA Maine currently has 11 diesel powered Caterpillar Generators for purposes of emergency power generation. These generators are an essential component of the hospitals building infrastructure system and are the single most important piece of equipment that will allow the hospital to remain operational in the event of a power loss. Emergency power equipment is both a major hospital system and requires highly specialized factory trained Caterpiller mechanics to perform their preventative maintenance. Hiring anyone else other than Caterpillar to work on this equipment could jeopardize the reliability and function of the generators. Further, many of the existing Caterpillar generators are still under factory warranty and require that preventative maintenance be performed by the equipment manufacturer; or the warranty will be voided. Milton CAT is the only contractor capable of performing the required work because this Emergency Generator System is proprietary to Caterpillar Corporation and will only have true full compatibility with other Caterpillar Corporation components and software. This notice of intent is not a solicitation nor is it a request for proposal. However, interested parties that believe they can satisfy the requirement listed above must clearly identify their capability to do so in writing by Monday, August 9, 2021 at 9 am EST time. Responses should be sent to Kenya Mitchell at contact@example.gov. Information submitted in response to this notice will be used solely to determine whether competitive procedures could be used for this acquisition. A determination not to open the requirement to competition based upon responses to this notice is solely within the discretion of the Government.

Similar Contracts

Same NAICS industry code

NAICS: 811310
New
Kubota M8200 Clutch Replacement
Solicitation # kubota-m8200-clutch-replacement
Management and Training Corporation is soliciting lump sum fee proposals for the clutch replacement of a Kubota M8200 tractor with front wheel assist, located at the Earle C. Clements Job Corps Center in Morganfield, Kentucky. The scope of work requires a qualified contractor to provide all transportation, labor, materials, and equipment to diagnose and repair the clutch assembly and power take-off system. Key technical requirements include replacing friction discs, bearings, oil seals, and O-rings, resurfacing the flywheel, and replacing hydraulic pipes and filters as needed. The contractor must perform all work according to manufacturer specifications and provide a final summary of diagnostic findings, an itemized list of replaced parts, and warranty documentation upon completion. This solicitation is set aside for small businesses, including VOSB, SDVOSB, WOSB, and HUBZone certified entities. Bids must be submitted via email to Angie Mahoney by 3:00 PM CST on November 3, 2026, and must include a bid sheet, proof of insurance, a completed supplier packet with a W-9, and applicable SBA certification letters. Award decisions will be based on best value, with a focus on administrative compliance and technical qualifications. The contract is subject to various Federal Acquisition Regulations, including standards for combating trafficking in persons, Buy American restrictions, and Service Contract Labor Standards per Wage Determination 2015-4687 Revision 31 for Kentucky.
Earle C. Clements Job Corps Center

POSTED

about 3 hours ago

DEADLINE

in 5 days
View Details
NAICS: 811310
New
SLED
ANNUAL ROTATING EQUIPMENT INSPECTION, TESTING, REPAIR, RECONDITIONING AND STORAGE SERVICES
Solicitation # 2026-RFP-130
Solicitation 2026-RFP-130, issued by the City of Lakeland, seeks qualified contractors to provide annual inspection, testing, repair, reconditioning, and storage services for critical rotating equipment at the McIntosh and Larsen Power Plants. The scope of work covers a wide range of industrial machinery, including low- and medium-voltage AC and DC electric motors, as well as circulating water and condensate pumps. Required services include clean inspect test (CIT) procedures, troubleshooting, motor rewinding, machining, welding, and dynamic field balancing. The contractor is also responsible for the pickup, transportation, and secure indoor storage of equipment, ensuring strict preservation measures such as periodic shaft rotation and moisture control to prevent corrosion and damage. The selection process is based on a points-based criteria to identify the vendor most responsive to the city's needs. Proposers must submit their responses via the OpenGov portal by October 30, 2026, and provide essential documentation including a signed W-9, Sunbiz registration, a notarized indemnification agreement, and a human trafficking affidavit. Contractors must adhere to strict safety standards, including OSHA compliance and specific certification for crane operations and critical lifts. Furthermore, vendors are required to maintain insurance policies with AM Best ratings of no less than A and must undergo a safety audit covering EMR and employee training records to ensure compliance with city risk management standards.
LE - Production - MPP

POSTED

about 7 hours ago

DEADLINE

in 8 days
View Details

More opportunities from Department Of Veterans Affairs → 241-NETWORK Contract Office 01 (36C241)

Same awarding agency

NAICS: 238990
New
Federal
Replacement-in-Kind Repair of Existing Perimeter Security Fence (Ameristar Impasse Trident) Brand Name or Equal
Solicitation # 36C24127Q0041
The Department of Veterans Affairs VA Boston Healthcare System is soliciting a contract for a localized replacement-in-kind repair of the perimeter security fence at the Brockton VA Campus in Massachusetts. The project focuses on restoring five affected fence bays and six associated post locations that were damaged by winter snow-removal activities. The objective is to return the damaged sections to their original alignment, configuration, appearance, structural stability, and security function. The benchmark product is the Ameristar Impasse Trident system, and while genuine components are preferred, equal alternatives may be proposed if they meet all salient characteristics, including the use of corrosion-resistant tamper-resistant hardware and the maintenance of a continuous security boundary. This procurement is a total set-aside for certified Service-Disabled Veteran-Owned Small Businesses (SDVOSB) under NAICS code 238990. The period of performance is scheduled from December 1, 2026, to January 31, 2027. Award decisions will be based on the most advantageous offer, considering price, technical capability, and past performance, with a requirement for three relevant references. Proposals must be submitted in three separate PDF volumes (Technical, Past Performance, and Price) to the contract specialist by November 5, 2026. Final acceptance is contingent upon a satisfactory installation inspection, which may include a review by VA Police to ensure operational security.
All Other Specialty Trade Contractors

POSTED

1 day ago

DEADLINE

in 7 days
View Details

Earlier notices in this NAICS code

Posted before this notice, open and closed

Ready to Pursue This Opportunity?

Get AI-powered intelligence on this solicitation and the ones like it

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS