K--Filter Weighing Room Control Modification

Awarded
PR-CI-04-10739Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

AI Contract Overview

Show more

The Environmental Protection Agency is seeking a small business vendor to modify the air conditioning and air handling system for a weigh-room at the National Vehicle and Fuels Emissions Laboratory in Ann Arbor, Michigan. The project aims to bring the facility into compliance with 2007 heavy-duty diesel fueled vehicle regulations. Key technical requirements include upgrading to ULPA filter media to maintain a Class 1000 rating, implementing a water-cooled HVAC system with PID control for precise temperature and dew point management, and providing optional air scrubbing for volatile organic compounds. The selected contractor must ensure the new Filter Room Control System interfaces with the existing EPA monitoring hardware via RS232 or analog signals and provides necessary software for data tracking. The contract will be awarded as a firm fixed price based on best value, evaluating technical experience, managerial ability, and schedule alongside price. This acquisition is set aside for small businesses under NAICS code 333415.

General Info

Contract Value

$95,600

NAICS

333415 - Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment Manufacturing

Place of Performance

OH, USA

Set-Aside

SBA

Award Issued Date

Documents

0

No documents available

Documents will appear here when they are available.

AI Contract Breakdown

Uniform Contract Format

No documents to break down

The breakdown needs solicitation documents. None were found from this contract's source.

Timeline

PhaseAwarded
Posted

Presolicitation

Awarded

Contract was awarded

Ready to pursue this opportunity?

Get full access to track this contract, build proposals with AI assistance, and manage your pipeline.

Organization & Contact Information

Show more
AgencyEnvironmental Protection Agency → Cincinnati Acquisition Division (cad)
Contacts1 person available
OfficeCINCINNATI, OH, 45268, USA
Office AddressCINCINNATI, OH, 45268, USA
Contacts
Matthew A GrowneyContracting Officer

Full Description

Show more
This synopsis is being provided to publish a requirement for the National Vehicle and Fuels Emissions Laboratory (NVFEL) of the Environmental Protection Agency (EPA) in Ann Arbor, Michigan which is seeking an experienced vendor to modify the air conditioning and air handling system for an existing weigh-room to meet requirements of the 2007 regulations for heavy-duty diesel fueled vehicles (40 CFR ?86.1312-2007). The present HVAC is a 5 ton CoolAir unit employing condenser/compressor cooling and flash vaporization humidification. Technical Specifications: 2.1 Structure The existing structure shall be used with only nominal modifications for ducting alterations. Existing suspended HVAC mechanical area shall be used for the new hardware. Existing ducting shall be reused as feasible or newly supplied as necessary for the upgrade equipment. 2.2 Filtration Existing HEPA room filtration media shall be replaced by ULPA filter media (ultra low particulate air filtration system; removal of 99.999% of particulates of size 0.12 microns or greater). The Weigh room shall maintain its Class 1000 rating (1000 particulates of size > 0.3 microns; 350 particulates of size > 0.5 microns; and 0 particulates of size > 5 microns are the maximum numbers permitted per cubic meter of air). The room must be maintained at a minimum of 15 Pa higher air pressure within the Class 1000 room as compared to the adjoining unclassified area. As a required option, the filtration system shall provide for air scrubbing for volatile organic compounds (VOCs), especially compounds in gasoline mixtures. For dry-scrubbing of (VOCs), the air filter system shall contain chemically impregnated media with the ability to reduce organic gases and odors in the intake and recycled air to a level < 1 ppm before it is introduced to the weigh-room. Filtration system must be designed so that filter media is easily replaceable. Filter media must have color change indicator or some other indicator to signal when the media needs to be changed. 2.3 HVAC and Filter Room Control System (FRCS) The control of the new HVAC System shall be based upon an advanced Proportional/Integral/ Differential controller (PID). The system shall cool constantly with PID controlled reheat/preheat and constantly dehumidify with PID controlled humidification. The following are considerations for determining what HVAC Hardware shall be supplied: The HVAC shall be a water-cooled system per facility management choice The HVAC shall incorporate continuous, proportional control for temperature and humidification employing a (PID) controller. This shall be implemented using either a separate Programable Logic Controller (PLC) supplied by the contractor, a separate program module incorporated into the existing EPA weighroom computer system, or a separate computer system supplied by the contractor. Electrical service and plumbing sources/drains are to be brought to the immediate HVAC area by EPA building maintenance or another contractor. The HVAC system shall not emit noise greater than 70 decibels in any direction at a nominal distance of 10 feet from the unit. The HVAC shall be installed in the large soak area that is maintained at a temperature range of 68 to 86 F with an absolute humidity of 50-75 grains per cubic ft. of dry air. The HVAC shall reject heat to the provided chilled water which is supplied at a temperature of 42 to 55 F at a pressure of 10 to 20 psi. For reheat, building hot water may be used. This is supplied at 125 to 170 F and has a hardness of 45 grains with PH over 9.2. Target control parameters are as follows: Temperature Monitor Resolution = 0.01 ?C Accuracy = ?0.2 ?C (with k = 2 at a 95% confidence interval) Dew point Monitor Resolution = 0.01 ?C Accuracy = 0.25 ?C (with k = 2 at a 95% confidence interval) Recovery response time to a temperature or dewpoint excursion of 5 ?C shall be a maximum of 2 minutes. Heat load in the room will consist of 4 technicians and 2 computers plus environmental monitors and controllers. The people will be moving in and out the filter room for any duration of time over a 24 hour period. Contractor Supplied Environmental Control System - The filter room environmental control system, FRCS, shall be selected by the contractor but must meet EPA performance criteria listed in sections 2.3.2.1 through 2.3.2.3. If a computer system is selected by the contractor, the system must meet EPA's interfacing requirements with the existing Filter Room Monitoring System (FRMS). 2.4 Environmental Control Room and Balance Temperature The environment shall be maintained at 22 ?C ? 1 ?C. Temperature shall be sampled 1 per second and an unweighted 5 minute moving average of this data shall be graphically recorded. The monitoring and control device shall be NIST traceable and accurate to at least ?0.2 ?C (k=2, 95% confidence). Room Balance Dew point The environment shall be maintained at a dew point of 9.5 ?C ? 1 ?C. The dew point shall be sampled 1 per second and an unweighted 5 minute moving average of this data shall be graphically recorded. The monitoring and control device shall be NIST traceable and accurate to at least ?0.25 ?C (k=2, 95% confidence). A Barometer with serial data output will be provided by EPA for incorporation into the environmental control. Compatibility with existing Filter Room Monitoring System (FRMS). The Filter Room Control System (FRCS) shall monitor at a frequency that will enable it to control temperatures and humidity per the performance criteria listed in sections 2.3.2.1 through 2.3.2.3. The following interface requirements must be met by the FRCS. The EPA Filter Room Monitor System (FRMS) computer will perform any required data averaging for purposes of reporting. An RS232 output of environmental parameters from the FRCS shall be available for the EPA's FRMS at a minimum data rate frequency of 2 Hertz. The existing software receives Dry Bulb, Dew Point and Humidity at 2 Hz through one serial port and Pressure through a second serial port. Use of the RS232 port or Analog signals by the EPA filter room monitor computer shall have no adverse effects on the Control System. 2.5 Fire Suppression ? Existing system to be used. No modification required. 2.6 Software - The vender shall specify and provide software for the FRCS if required. Software, if required by the FRCS, shall be developed using commercially available programs such as Labview or Visual Basic. A copy of all code developed for this project shall provided by the contractor. Supplied software should allow Visual Basic or an Oracle database to query for most recent 5 min. average values for the parameters listed in section 2.3.2. 2.7 - Interface Requirements for the FRMS Hardware requirements for data supplied to the FRMS. For an optional analog interface: The dewpoint and temperature monitors shall be equipped with three 4 to 20 mA current outputs. These 2-wire channels must be powered with 12 to 28 VDC external power supplies (not provided). The analog outputs are galvanically isolated from electronics but they are not isolated from each other. A separate (isolated) power supply is required for each analog channel. Analog output signals for access to ambient temperatures and humidity shall be optically isolated so that FCMS access shall not have any adverse impacts on the FRCS. For the required serial interface: The dewpoint and temperature monitors shall provide serial data at the required frequency using a serial cable. Data values shall be delimited or labeled in the communication stream so that values may be parsed from the communication string by FCMS computer software. 2.8 - Acceptance Test Requirements Data logged by the EPA supplied FRMS shall be evaluated for a period of one week to verify FRCS functionality per the performance criteria listed in sections 2.3.2.1 through 2.3.2.3 and section 2.4. THE EPA HAS SET THIS ACQUISITION ASIDE FOR SMALL BUSINESS. The North American Industry Classification Code is 333415 with a small business size standard of 750 employees. A written solicitation, PR-CI-04-10739, is anticipated to be issued on Wednesday 5/26/04. It is anticipated the solicitation will be issued as a request for proposals (RFP). All responsible small business sources may submit a quotation in response to the solicitation which shall be considered by the Agency. This procurement will be pursued using FAR Part 12 Commercial Acquisition methods and procedures. This notice of intent is not a request for competitive quotations. A site visit opportunity will be announced in the solicitation it will take place on a date to be determined at the installation site: US EPA, National Fuel and Vehicle Emission Laboratory, 2565 Plymouth Road, Ann Arbor, Michigan 48105. The Agency intends for this event to constitute the sole site visit opportunity for prospective offerors. The Agency is under no obligation to make accommodations for those unable to attend the site visit event as scheduled. Additional specifications, descriptions of the area and general layout, will be made available along with the solicitation. The Government will award a contract resulting from this solicitation to the responsible offeror whose offer conforming to the solicitation will be most advantageous to the Government, price and other factors considered. An offer must include the minimum requirements of the Performance Work Statement (PWS). In addition to price, the following factors will be used to evaluate the offeror's technical proposal: responsiveness to the PWS, previous technical experience, managerial ability, schedule and delivery. These factors shall be evaluated on a Best Value basis. Contract type will be firm fixed price.

Similar Contracts

Same NAICS industry code

NAICS: 333415
New
DIBBS
AIR CONDITIONER
Solicitation # SPE8E8-27-T-0208
Solicitation SPE8E8-27-T-0208 is a request for quotations issued by DLA Troop Support Construction and Equipment for the procurement of three air conditioner units. The required hardware is identified by part number 640315CXX1C0 from Dometic Environmental Corp (DBA 4XB81) and NSN 4120017018393. The need ship date is April 12, 2027, with an original required delivery date of May 25, 2027. Delivery is set as FOB Origin, with inspection and acceptance occurring at the destination, specifically the DLA Distribution DDSP New Cumberland Facility in Pennsylvania. The contractor must adhere to strict packaging and marking standards, including MIL-STD-129 and ASTM D3951, with palletization following DLA requirement RP001. Technical and quality requirements are governed by the DLA Master List, including specific mandates for the removal of government identification from non-accepted supplies and source approval documentation. Payment and invoicing must be processed electronically through the Wide Area WorkFlow system. Compliance requirements include adherence to the Buy American Act, the Berry Amendment, and various DFARS regulations regarding cybersecurity, safeguarding covered defense information, and the prohibition of covered defense telecommunications equipment. Offerors must submit their quotes via the DLA Internet Bid Board System (DIBBS) under NAICS code 333415.
DDSP NEW CUMBERLAND FACILITY

POSTED

about 12 hours ago

DEADLINE

in 5 days
View Details
NAICS: 333415
New
Federal
NSWCCD York Chill Pump Replacement
Solicitation # N0016727Q1002
The Naval Surface Warfare Center, Carderock Division (NSWCCD) is soliciting quotes for the procurement, delivery, and turn-key installation of a replacement pump (Pump No. 1) for York Chiller No. 1 in Building 157. This equipment is critical for providing chilled-water cooling to the Building 13 Server Rooms. The project requires the removal of the damaged pump and the installation of a York Chill Pump, Model YLAA0080SJ46X, Serial SEMM-609950. Due to the proprietary nature of the equipment, the contractor must utilize certified Johnson Controls technicians or representatives. The installation must be completed on or before December 18, 2026, at the NSWCCD facility in Bethesda, Maryland. This is a brand-name restricted procurement under full and open competition and is not set aside for small businesses. The government intends to award a single firm-fixed-price purchase order based on the lowest price technically acceptable method, evaluating quotations on a pass/fail basis for technical requirements and considering past performance via the Supplier Performance Risk System. All quotes must be submitted on official company letterhead, including all-inclusive pricing and business size, and sent via email to the contract specialist and contracting officer by 09:00 AM EDT on November 06, 2026. The contract includes specific requirements for item unique identification per MIL-STD-130 and electronic invoicing through the Wide Area WorkFlow system.
Nswc Carderock

POSTED

about 17 hours ago

DEADLINE

in 17 days
View Details

More opportunities from Environmental Protection Agency → Cincinnati Acquisition Division (cad)

Same awarding agency

Earlier notices in this NAICS code

Posted before this notice, open and closed

Ready to Pursue This Opportunity?

Get AI-powered intelligence on this solicitation and the ones like it

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS