Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, November 11 at 2:00 PM ET

Register Free →

This Combined Synopsis/Solicitation opportunity from International Boundary And Water Commission: Us-Mexico was posted on May 2, 2026. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

LAN HVAC Replacement

Closed
FY261222006Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 238220
New
CBP#9772 HVAC Air Handling Unit (AHU) and Ductwork Cleaning Services
Solicitation # CBP#9772
Management & Training Corporation (MTC) is soliciting bids for solicitation CBP#9772 to provide HVAC Air Handling Unit (AHU) and ductwork cleaning services at the Edison Job Corps Center in Edison, New Jersey. This fixed-price, single lump sum subcontracting opportunity has an estimated value between $100,000 and $250,000. The scope of work requires the thorough cleaning of twelve AHUs and associated coils and ductwork across the Kilmer and Edison Dormitories. Key deliverables include pre-cleaning inspections documented with photographs, the installation of permanent corrosion-resistant access panels, and a final project report. The contractor must complete all work within 90 consecutive business days following a written Notice to Proceed. Bids are due by November 17, 2026, and will be awarded based on overall best value. A mandatory physical site visit and signature on the attendance roster are required prior to bid submission. For bids equal to or greater than $25,000, a bid bond of 20% of the base bid is required, and the awarded contractor must provide performance and payment bonds from a surety company with at least an A- rating. The project is set aside for small businesses, including VOSB, SDVOSB, WOSB, and HUBZone certifications. Compliance with Davis-Bacon prevailing wage determinations for Middlesex County and various FAR clauses regarding security, privacy, and the Buy American Act is mandatory. Final acceptance is contingent upon a written confirmation from the Center following a successful inspection of the operational status of the equipment and the restoration of work areas.
Edison Job Corps

POSTED

about 5 hours ago

DEADLINE

in 19 days
NAICS: 238220
New
WOJC - Multi-Building Plumbing Leak Repair Project
Solicitation # WOJC – Multi-Building Plumbing Leak Repair Project
Education and Training Resources is seeking quotes for a subcontracting opportunity to perform multi-building plumbing leak repairs at the Westover Job Corps Center in Chicopee, Massachusetts. The scope of work includes replacing leaking shower P-trap drain pipes in Harris Hall dormitory (Rooms 123 and 213), repairing a cracked drain pipe in the pipe chase of Room 216, and replacing heat pipe sections in both the Administration Building and King Hall. All work must comply with the Massachusetts State Plumbing Code, International Plumbing Code, and OSHA safety standards, including lock-out/tag-out procedures. Contractors are responsible for providing all new commercial-quality materials and must repair any facility damage caused during performance at no additional cost. Bids are due by October 30, 2026, and must include a detailed cost breakdown on a Bid Sheet, a proposed service schedule, and proof of required Massachusetts licensing. Evaluation is based on cost, qualifications, and administrative compliance, with ETR serving as the sole judge for the award. Mandatory submission requirements include a SAM.gov UEI number, active registration, W-9, business licenses, and certificates of liability insurance. Depending on the project value, payment and performance bonds may be required for contracts exceeding 35,000 dollars. The project is subject to federal regulations, including the Davis-Bacon Act and Service Contract Act, requiring the submission of weekly certified payroll reports.
Westover Job Corps Center

POSTED

about 5 hours ago

DEADLINE

in about 13 hours
NAICS: 238220
New
MJCC EXHAUST FANS BLD. 1429
Solicitation # mjcc-exhaust-fans-bld-1429
The Muhlenberg Job Corps Center, operated by Insights Training Group LLC, is soliciting fixed price quotes from qualified HVAC and mechanical contractors to restore the exhaust fan and louver systems in Building 1429 located in Kentucky. The scope of work includes inspecting, repairing, and replacing various components across eight exhaust fans, specifically addressing failed louver actuators, motors, thermostats, blades, and guards. Contractors must ensure all equipment is fully operational and provide all necessary training and maintenance manuals. The project requires adherence to applicable building codes, manufacturer requirements, and OSHA and EPA regulations, including strict chemical management and the maintenance of Material Safety Data Sheets. This is a small business set-aside solicitation open to VOSB, SDVOSB, WOSB, and HUBZone certified entities. Award will be granted to the responsible offeror with a technically acceptable quote at the lowest price. Proposals must be submitted by October 30, 2026, and include a detailed cost breakdown, evidence of Kentucky state licensing, and proof of bonding capability. The contract is subject to the Davis-Bacon Act and FAR 22.403-1-CWRR, requiring the submission of weekly certified payroll with every invoice. Final payment is contingent upon satisfactory performance and the delivery of lien releases from all subcontractors and suppliers.
Muhlenberg Job Corps Center / Insights Training Group LLC

POSTED

about 5 hours ago

DEADLINE

in about 13 hours
NAICS: 238220
New
Centennial Dry Sprinkler System & Compressor Replacement Services
Solicitation # centennial-dry-sprinkler-system-compressor-replacement-services
Management & Training Corporation is soliciting bids for a fixed-price, single lump sum subcontract to provide dry-type sprinkler system and compressor replacement services at the Centennial Job Corps Center in Nampa, Idaho. The project scope involves the demolition and removal of existing distribution piping and air compressors in the Men's Dormitory, Women's Dormitory, and Recreation Building, followed by the installation of a new piping network and a code-approved air compressor. All work must adhere to NFPA 25 (2023 Edition) standards and local, state, and national codes. The selected contractor must complete all work within 30 consecutive business days following the written Notice to Proceed. Bids are due by December 1, 2026, and will be evaluated based on overall best value. Prospective bidders must conduct a mandatory physical site visit and sign an attendance roster to be considered. For bids equal to or greater than $25,000, a bid bond guarantee of 20% of the base bid is required at the time of submission, and performance and payment bonds from an A-rated surety will be required upon award. The solicitation is set aside for HUBZone, Woman-owned, and Service-Disabled Veteran-owned small businesses. Contractors must comply with prevailing wage rates per the Davis-Bacon Act and submit weekly certified payroll reports to receive payment. Required documentation for award includes a detailed cost breakout, proof of insurance, a UEI number, and a completed SF 1413 form. Final payment is contingent upon a successful final inspection, the submission of operation and maintenance manuals, and the delivery of a certificate of release of liens. First-tier subcontractors with awards exceeding $45,000 must also provide disclosures regarding debarment and suspension per FAR 52.209-6.
Management & Training Corporation/Centennial Job Corps Center

POSTED

about 5 hours ago

DEADLINE

in about 1 month
NAICS: 238220
New
Dorm Hot Water Tank Replacement – Glenmont Job Corps Center – S26-006
Solicitation # S26-006
Adams and Associates, Inc. is seeking qualified mechanical and plumbing contractors for a subcontracting project at the Glenmont Job Corps Center in Glenmont, New York. The scope of work involves the removal and disposal of four existing 505-gallon domestic hot water storage tanks and the installation of four new 500-gallon insulated storage tanks, with two tanks per dormitory. Additionally, the contractor must replace four heat exchangers and install one new bronze Bell and Gossett circulator pump in the North Dormitory. Comprehensive services required include piping modifications using ProPress materials, electrical disconnections and reconnections, insulation matching existing standards, rigging, and the provision of a temporary hot water heater to ensure the facility remains operational during the estimated construction period of two and a half to three weeks. Proposals are due by November 9, 2026, at 4:00 PM ET, following a pre-proposal site walkthrough on October 29, 2026. Award selection is based on a weighted evaluation of price (60 percent), quality (20 percent), past performance (10 percent), and schedule (10 percent), meaning the lowest price does not guarantee selection. Contractors must comply with New York State statutory insurance requirements, Davis-Bacon prevailing wage determinations, and strict center security and safety regulations, including a no-fraternization policy with students. Required submission documents include a completed vendor questionnaire with UEI and NAICS codes, a current W-9, and applicable New York State licenses. Payment terms are Net 30 days upon completion and receipt of invoice.
Adams and Associates, Inc.

POSTED

about 5 hours ago

DEADLINE

in 11 days
NAICS: 238220
New
MJCC HVAC BLD. 1403-04 B HALL
Solicitation # mjcc-hvac-bld-1403-04-b-hall
Insights Training Group LLC, on behalf of the Muhlenberg Job Corps Center in Kentucky, is soliciting fixed-price quotes for an HVAC project at Building 1403-04 B Hall. The scope of work requires the contractor to furnish and install two 4-ton Trane 17 SEER (minimum) twinned split systems using R-454B refrigerant, including two 95% AFUE high-efficiency gas furnaces, matching indoor evaporator coils, and one Honeywell Pro 8000 programmable thermostat with a remote sensor. The project also encompasses the installation of new refrigerant line sets, exterior line hide, and necessary condensate management systems. All work must be completed within 45 days of award and adhere to manufacturer specifications, local codes, and OSHA and EPA regulations. The contract will be awarded to the responsible offeror whose quote is technically acceptable and represents the lowest price. To be considered, bidders must provide evidence of Kentucky state licensing and registration, a minimum 90-day bid guarantee, proof of ability to secure performance and payment bonding, a completed New Vendor Profile, and a W-9. The project is subject to Davis-Bacon Act labor standards, requiring the submission of weekly certified payroll and a signed Statement of Compliance with every invoice. Final acceptance is contingent upon a substantial completion walk-through by the center director, the provision of all operating and maintenance manuals, and the verification of proper zoning and temperature control. Quotes are due by October 30, 2026, at 5:00 PM.
Muhlenberg Job Corps Center / Insights Training Group LLC

POSTED

about 5 hours ago

DEADLINE

in about 13 hours
NAICS: 238220
New
Roswell JCC – Male Dormitory Bldg. Water Source Heat Pump Replacement (20 units)
Solicitation # roswell-jcc-male-dormitory-bldg-water-source-heat-pump-replacement-20-units
The Career Systems Development Corporation is soliciting proposals for the total replacement of twenty ceiling-mounted water source heat pumps at the Roswell Job Corps Center Male Dormitory Building 558 in New Mexico. The scope of work involves the removal and off-site disposal of twenty failed units and the installation of new Bosch 1-ton units or an equivalent model. Additionally, the contractor must install smoke dampers with fusible links in all vents leading into the plenum and ensure all installed plenum materials are plenum rated. All work must comply with NFPA 101, NFPA 70, and applicable plumbing, mechanical, and building codes. This solicitation is set aside for small businesses, including VOSB, SDVOSB, WOSB, and HUBZone certified firms. The project is subject to the Davis Bacon Act Wage Determination NM20260014, requiring the submission and approval of weekly certified payroll reports prior to invoice payment. Proposals exceeding 100,000 dollars require 100 percent payment and performance bonding upon award. Submissions must include a safe work process, detailed material and labor costs, total project cost, equipment cut sheets, warranty information, and a proposed payment schedule. Final deliverables include the operation manuals provided to the Facility Manager upon completion.
Career Systems Development Corporation

POSTED

about 5 hours ago

DEADLINE

in 9 days

AI Contract Overview

Show more

This solicitation, identified as FY261222006, is a 100% Small Business Set-Aside for the replacement of the LAN HVAC system at the International Boundary and Water Commission’s El Paso Headquarters located at 4191 N. Mesa, El Paso, TX 79902. The requirement is classified under NAICS code 238220 with a small business size standard of $19.0 million in average annual receipts, and only offers from certified small businesses will be considered. The procurement follows FAR Subpart 12.6 as a combined synopsis and solicitation for commercial items, issued as a Request for Quote (RFQ) with no separate written solicitation. Bidders must submit quotes for all CLINs as a single, complete offer—accepting the requirement on an “ALL or NONE” basis—and must include an active Unique Entity Identifier (UEI). Quotes must remain valid for 90 days and be submitted via email to [email hidden] no later than 3:00 p.m. MST on May 6, 2026, with questions limited to submissions received by May 1, 2026. The government will award using the Lowest Price Technically Acceptable (LPTA) method, prioritizing technical acceptability before price evaluation. Technical proposals must include a detailed narrative covering the plan of action, equipment specifications, key personnel, and schedule, along with at least three verifiable references of similar past projects, including contact details and project descriptions. All equipment must meet a 23 kW cooling capacity requirement (corrected from an earlier erroneous 23-ton specification), utilize R-410A refrigerant, operate on 460V 3-phase power, and achieve a minimum EER of 10.0. Brand-specific equipment is not required; equivalent alternatives are acceptable provided they meet all technical specifications, integrate with existing infrastructure, and are submitted for technical review. Installation involves removing existing units, installing a motorized damper to interface with the existing Carrier HVAC, and connecting to the existing electrical system via a Triple 50A breaker on 480V, with line sets confirmed as operational but requiring flushing. The condenser resides on the third-floor roof and can only be accessed via crane from the southwest corner of the building, while the evaporator unit is in a server room on the second floor with elevator access constrained to

General Info

Small business set-aside for 23 kW LAN HVAC replacement at El Paso HQ using R-410A, 460V, EER 10+, LPTA award, all-or-nothing quote by May 6, 2026.

NAICS

238220 - Plumbing, Heating, and Air-Conditioning Contractors

Place of Performance

El Paso, TX, 79902, USA

Set-Aside

SBA

Documents

5

FY261222006 LAN HVAC System Replacement Scope of Work

PDF, High priority: read this firstsow
High

Applicable+Terms+and+Conditions.pdf

PDF

CLIN+Structure.docx

DOCX

Site+Visit+Sign-in+04.24.2026.pdf

PDF

Updated+SOW_LAN+HVAC+Replacement_updated+04.29.2026.pdf

PDF

AI Contract Breakdown

Uniform Contract Format

Sign up to view the full breakdown with detailed analysis of each section.

Timeline

8 updates
PhaseClosed
Posted

Combined Synopsis

Notice updated

The notice description changed.

Notice updated

The notice description changed.

Notice updated

The notice description changed.

Notice updated

The notice description changed.

Notice updated

The notice description changed.

Notice updated

The notice description changed.

Notice updated

The notice description changed.

Notice updated

The notice description changed.

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyInternational Boundary And Water Commission: Us-Mexico → Internat Boundary And Water Commission
Contacts2 people available
OfficeEl Paso, TX, 79902, USA
Office AddressEl Paso, TX, 79902, USA
Contacts
Angelica Baca
Seone Michael Jones

Full Description

Show more

This is a combined synopsis/solicitation for commercial items in accordance with the format in FAR Subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; quotes are being requested, and a written solicitation will not be issued separately.


The solicitation number is FY261222006. This solicitation is issued as a request for quote (RFQ) for LAN HVAC Replacement at El Paso, HQ, 4191 N. Mesa, El Paso, TX 79902.


This is a 100% Small Business Set Aside. Only offers from Small Businesses will be considered for this solicitation.


The associated North American Industry Classification System (NAICS) code is 238220 – Plumbing, Heating, and Air-Conditioning Contractors. Product of Service Code for this requirement is N041–Installation of Equipment-Refrigeration, Air Conditioning, and Air Circulating Equipment. The Small Business Administration (SBA) size standard for this sector is $19.0 Million.


Services shall be quoted ALL or NONE as per CLIN structure and SOW attached. CLIN structure needs to be returned with your quote via e-mail directly to my attention at contact@example.gov.


Quotes shall be good for 90 Days.


Offer due date/local time: May 6, 2026; 3:00 pm MST.


Only questions submitted by email to contact@example.gov will be considered. Questions received from Offerors after 3p on May 1, 2026, may not be responded to.


Active UEI (Unique Entity Identifier) must be included in your offer.


Description: The International Boundary and Water Commission, United States Section (IBWC) requires LAN HVAC Replacement for El Paso HQ, 4191 N. Mesa, El Paso, TX 79902.


COR for this request: Antonio Almaguer (please do not contact him directly if you have any questions). All questions need to be directed to my attention.


Evaluation of Offer – The Government will award a contract resulting from this solicitation to the responsible offeror whose offer conforming to the solicitation will be most advantageous to the Government, price and other factors considered. The following factors shall be used to evaluate Offers: Technical acceptability to meet IBWC requirements; Technical Approach and Past Performance.


The Government will award a contract resulting from this combined synopsis/solicitation to the lowest price technically acceptable (LPTA), responsible offeror.


Technical Approach - Quote must demonstrate the technical approach by providing a narrative addressing all the items in the scope. The narrative shall at a minimum include your plan of action, equipment, key team members, and schedule.


Past Performance – Quotes shall demonstrate successful past performance of at least 3 three (3) references for similar projects. The information shall include name of person, company, phone number, email address, and brief description of the project.


Offerors shall meet or exceed and specifications and scope of work of items being quoted.


Offerors shall include a completed copy of the provision at 52.212-3, Offeror Representations and Certifications-Commercial Items, with its offer. NOTE: The offeror shall complete only paragraph (b) of this provision if the Offeror has completed the annual representations and certification electronically via the System for Award Management (SAM) website accessed at https://www.sam.gov.


END of combined synopsis/solicitation


Attachments:


CLIN Structure


Clauses and Provisions


Scope of Work


Modification 001 - 4/20/26 -  My client will be conducting a single site visit for all interested vendors, which is scheduled for April 24th from 9:00 to 10:00 a.m. Please note that this will be the only site visit available, so I encourage your team to attend during this time. Direct POC: Sebastian Calderon contact@example.gov


Modification 002 - Q&A 4/21/26 -


Is the outdoor condensing unit on top of the roof? Yes


How many stories? 3 stories high and is the model corresponding to the Evaporative unit that we have in the Server room.


Are you using a third party such as Automated Logic for the  BMS Controls integration? The unit is controlled from the built-in console on the evaporative unit in the server room (servicing area) not part of the Building Automation System (BMS). 


Modification 003 - Q&A 4/22/26 - To include Technical Approach and Past Performance on solicitation description.


Modification 004 - Site Visit information 4/26/26:


-The server room is on the second floor accessible by elevator or stairs.


-Elevator capacity is 4000 lbs.; 4X7 ft door, Dimensions: 4ft W, 6.5ft L, 7.3ft H.


-Evaporator Unit in Server room with 3ft door access to hallway.


-Condenser on 3rd Floor Roof with Crane access only from SW corner of Bldg.


Modification 005 - Add Q&As below and attached Site visit sign in sheet - 4/28/26


  1. The Performance Specification lists the Liebert PX023UA1A809KM PDX Air-Cooled System as a 23-ton machine. However, according to the manufacturer, this model is a 23kW unit, which is approximately 6.5 tons. Could you please confirm if the requirement is for a 23-ton or a 6.5-ton machine?                                                                                    The reference to a “23‑ton” system in the Statement of Work was a clerical error. The correct requirement is 23 kW. All proposed equipment must meet the performance, environmental, and operational criteria associated with a 23 kW cooling system. This correction supersedes any earlier references in the SOW.                                                                                                                                                                                                                                                           2.    Does the client require the Liebert brand specifically, or may we propose an equivalent alternative?                   The agency does not require the Liebert brand specifically. Equivalent alternatives are acceptable; however, all proposed substitutes must:
    1. Meet or exceed all technical specifications outlined in the SOW,
    2. Demonstrate full compatibility with existing infrastructure,
    3. Include supporting documentation verifying equivalency, and
    4. Be submitted for agency technical review.                                                                                                  Please ensure that any proposed equipment aligns with the agency’s operational needs and long‑term support considerations.                                                                                                                                                                                                                                                                                                        3. The SOW in section 4. Performance Specification a “23 tons” HVAC unit but the Liebert PX023uA1A809KM model is rated at 23 kW (~6.5 tons). Please clarify are you expecting a 23 ton unit?   The reference to a “23‑ton” system in the Statement of Work was a clerical error. The correct requirement is 23 kW. All proposed equipment must meet the performance, environmental, and operational criteria associated with a 23 kW cooling system. This correction supersedes any earlier references in the SOW.                                                                                                                                4. Could you confirm the location of the electrical panel that feeds the indoor and outdoor Liebert units? The bid documents note reconnecting the new equipment to the existing electrical infrastructure, but I do not recall seeing the associated panel during the walk.                                                                            The 4x4 junction box next to the Liebert unit is labeled with “Panel H1, Circuit 20,22,24 480volts” the Breaker panel H1 is in 1st floor supply room, close to West exit door.  I do not have information on brakers to Condenser unit on the roof.
    5. The line sets specified for the new unit are the same size as the existing ones. Can you confirm whether the current lines can be reused? We understand they would still need to be properly flushed and cleaned. If replacement is required, could you provide approximate lengths from the indoor unit to the outdoor unit?                                                                                                                                                                Line sets are currently operational and in use                                                                                                                                                                                                                                                        Modification 006 - Update SOW attachment - 4/29/26                                                                                                                                                                                                                                    Modification 007 - 5/1/26 - Q&As below:                                                                                                  
    6. -Line set is currently operational and in use. Line set is currently operational and in use.


      -The server room is on the second floor accessible by elevator or stairs. The server room is on the second floor accessible by elevator or stairs.


      -Elevator capacity is 4000 lbs.; 4X7 ft door, Dimensions: 4ft W, 6.5ft L, 7.3ft H. Elevator capacity is 4000 lbs.; 4X7 ft door, Dimensions: 4ft W, 6.5ft L, 7.3ft H.


      -Evaporator Unit in Server room with 3ft door access to hallway. Evaporator Unit in Server room with 3ft door access to hallway.


      -Condenser on 3rd Floor Roof with Crane access only from SW corner of Bldg. Condenser on 3rd Floor Roof with Crane access only from SW corner of Bldg                                                                              The line sets specified for the new unit are the same size as the existing ones. Can you confirm whether the current lines can be reused? We understand they would still need to be properly flushed and cleaned. If replacement is required, could you provide approximate lengths from the indoor unit to the outdoor unit?                                                                                                                                                                Line sets are currently operational and in use                                                                                                                                                                                                                                                          Modification 008 - 5/2/26 - Q&As below:                                                                                                  

    7. Please confirm the required electrical capacity for the new Liebert unit (MCA and MOCP).
    8. Based on site observations, the existing wiring appears to be sized for approximately 60 amps (#6 conductors with 3/4" conduit).
    9. Please confirm if the existing electrical infrastructure is adequate, or if new feeders, conduit, or breaker upgrades will be required.                                                                                                                              The Unit is connected to a Triple 50A Breaker and is supplying 480 volts.  Wires and ¾ inch conduit were installed when we moved into this building somewhere around 2018/9.                                                                                                                                                                                                                                                                                                                                                                                                                                                                            









More opportunities from International Boundary And Water Commission: Us-Mexico → Internat Boundary And Water Commission

Same awarding agency

NAICS: 221320
Federal
Operations and Maintenance (O&M) Services for the SBIWTP
Solicitation # 191BWC26R0009
Solicitation 191BWC26R0009, issued by the International Boundary and Water Commission, seeks a contractor to provide Firm Fixed Price Operations and Maintenance (O&M) services for the South Bay International Wastewater Treatment Plant (SBIWTP) in San Ysidro, California. The contract is structured with a base year running from June 1, 2027, to May 31, 2028, and multiple option years extending through May 2031. A primary objective of the scope is managing plant operations, SCADA systems, and maintenance during the facility's expansion from 25 MGD to 50 MGD. The contractor must ensure 24/7 staffing, including a bilingual operator, and maintain strict compliance with the National Pollutant Discharge Elimination System (NPDES) permit and other regional water quality board regulations. Award will be based on the Highest Technically Rated with a Fair and Reasonable Price method, where non-price factors—such as plant operations, permit compliance, and staffing—are significantly more important than cost. Key requirements include the designation of a Project Manager, Superintendent, Site Safety and Health Officer, SCADA Specialist, and Asset Manager. The contractor is responsible for a wide array of deliverables, including a Phase-In Plan, Preventative Maintenance Plan, and monthly performance reports. Security is a high priority, requiring background investigations for personnel and adherence to NIST standards for protecting Controlled Unclassified Information. Performance will be monitored via a Quality Assurance Surveillance Plan focusing on regulatory compliance, uptime, and effluent quality.
Sewage Treatment Facilities

POSTED

9 days ago

DEADLINE

in 2 months
View Details

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS