Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, September 16 at 2:00 PM EDT

Register Free →

This Combined Synopsis/Solicitation opportunity from International Boundary And Water Commission: Us-Mexico was posted on May 2, 2026. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

LAN HVAC Replacement

Closed
FY261222006Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 238220
New
SLED
ICE 8A - Ft Benning Improvements
Solicitation # 70CMSW25R00000011
Solicitation 70CMSW25R00000011 is a firm-fixed-price task order issued under an 8(a) Multiple Award Construction Contract (MACC) for design-build services to support the Immigration and Customs Enforcement (ICE) Office of Firearms and Tactical Programs at Fort Benning, Georgia. The project, valued between 4.0 million and 4.5 million dollars, focuses on life, safety, and operational improvements. The scope of work includes the installation of two aluminum awnings at the shipping and receiving dock and Fiske Range Lane 2, turf replacement at Fiske Range, the demolition of Building 2294, gutter and drainage improvements for Building 234, commercial HVAC services and replacements, and general facility improvements for Building 301 and the DAGr Team facility. The period of performance is 365 days from the date of award. Award will be based solely on the lowest total evaluated price, provided the offeror demonstrates a sound technical approach, appropriate design resources, and a comprehensive quality control and safety program. The contract is subject to the Davis-Bacon Act, requiring prevailing wage rates and specific paid sick leave for workers. Performance and payment bonds are required per FAR 52.228-15. Proposals must be submitted in two volumes: a technical and safety volume and a pricing volume using the provided template. All payment requests must be processed electronically via the Invoice Processing Platform and accompanied by certified payroll.
Bristol Alliance of Companies

POSTED

about 13 hours ago

DEADLINE

in 6 days
NAICS: 238220
New
SLED
PIDC Project 3 - Dorm RTU Replacement and SCADA
Solicitation # 872287
This firm-fixed-price task order, issued under an 8(a) MACC IDIQ, involves the replacement and upgrade of Rooftop HVAC Units (RTUs) for the Alpha, Bravo, Charlie, and Delta dorms, as well as a SCADA system upgrade at the Port Isabel Detention Center in Los Fresnos, Texas. The project objective is to replace corroded and obsolete equipment with high-quality, coastal weather-resistant, and durable systems that exceed commercial standards. The scope includes removing existing RTUs, replacing necessary piping, electrical, and ducting, and installing new SCADA software and two chemical feed pumps in compliance with Texas Commission of Environmental Quality standards. The estimated magnitude of the project is between 1.2 million and 1.5 million dollars, with a period of performance of 365 days from the date of award. Award will be based solely on the lowest total evaluated price, provided the offeror demonstrates a sound technical approach, appropriate design resources, and a comprehensive quality control and safety program. Key requirements include the submission of a Quality Control Plan, a safety plan, and the designation of a Project Manager with at least five years of relevant federal contracting experience. The contractor must also provide a one-year warranty for installation and craftsmanship and ensure all personnel pass required background checks for site access. Compliance with the Davis-Bacon Act and associated executive orders regarding wages and sick leave is mandatory. All payment requests must be submitted electronically via the Invoice Processing Platform and accompanied by certified payroll.
Bristol Alliance of Companies

POSTED

about 13 hours ago

DEADLINE

in 13 days
NAICS: 238220
New
RFQ7593 Smoke Detector Installation
Solicitation # RFQ7593
Management & Training Corporation (MTC) is soliciting bids for a fee-for-service subcontracting opportunity to provide smoke detector installation and fire system services at the Sierra Nevada Job Corps Center in Reno, Nevada. The scope of work requires the replacement of 43 smoke detectors across specific dormitory rooms, including 12 detectors in rooms 11, 15, and 18, 12 detectors in room 19, and 19 detectors in rooms 20 and 21. The contractor must ensure all installed detectors communicate with the fire panel and that all work adheres to NFPA standards and local Authority Having Jurisdiction requirements. Bids must be submitted via email to Tom Williams by 3:00 PM PST on September 18, 2026. To be considered, applicants must provide a completed bid sheet, proof of insurance, and a supplier packet containing a W-9, self-certification form, and acceptance of terms and conditions. This opportunity is open to various small business set-asides, including SDB, WOSB, HUBZone, and Veteran-Owned businesses, under NAICS code 238220. Award decisions will be based on the best value as determined by MTC. The contract mandates compliance with Service Contract Labor Standards and Wage Determination No. 2015-5595 Revision 28 for labor rates in Washoe and Storey counties. Additionally, subcontractors must provide a 12-digit Unique Entity ID and certify their debarment status under FAR 52.209-6 if the subcontract exceeds 30,000 dollars. Strict adherence to government and Department of Labor guidance regarding the protection of sensitive and proprietary information is required.
Sierra Nevada Job Corps Center

POSTED

about 13 hours ago

DEADLINE

in 7 days
NAICS: 238220
New
2026-Clearfield-Bldg E8 Welding HVAC
Solicitation # 2026- Clearfield- Welding Bldg. E8 HVAC Replacement
Management & Training Corporation is seeking fixed-price lump sum bids for a subcontracting opportunity to replace the HVAC system at Building E8 Welding within the Clearfield Job Corps Center in Clearfield, Utah. The scope of work includes the complete change-out of the existing motor, installation of wiring, conduit, disconnects, breakers, fuses, and starters, and the subsequent validation of voltage, phase, and grounding. Deliverables include startup and testing documentation, onsite training for maintenance personnel, and the provision of manufacturer O&M manuals. All work must adhere to OSHA requirements, federal, state, and local codes, and site safety procedures. Bids must be submitted via email to nelson.dar@jobcorps.org and patricia.willover@mtctrains.com by September 19, 2026, at 3:00 PM MST. To be considered for award based on overall best value, offerors must complete a physical site visit, provide a detailed bid breakout on company letterhead, and submit a bid bond guarantee. The project is a small business set-aside under NAICS 238220 and requires compliance with Davis-Bacon prevailing wage determinations for Davis County. Awardees must provide a UEI number, submit a Schedule of Values for invoicing via AIA G702/G703 forms, and provide original payment and performance bonds from a surety with at least an A- rating within five business days of an Intent to Award letter. Performance dates will be established upon the signing of a Notice to Proceed.
Management & Training Corporation

POSTED

about 13 hours ago

DEADLINE

in 8 days
NAICS: 238220
New
CBP7664 Wellness HVAC Compressor Replacement
Solicitation # CBP7664
Management & Training Corporation is seeking bids for a subcontracting opportunity to replace a failed HVAC/refrigeration compressor at the Wellness facility of the Sierra Nevada Job Corps Center in Reno, Nevada. This fixed-price, single lump sum contract requires the contractor to provide all labor, materials, and equipment to execute a five-phase process including preparation, demolition, installation of an OEM-specified compressor, system testing and commissioning, and final closeout. The project must restore full cooling capacity and operational efficiency while adhering to EPA Section 608 regulations for refrigerant recovery. The work must be completed within thirty consecutive business days following the receipt of a written Notice to Proceed. Bids will be evaluated based on overall best value, considering price, quality, and delivery schedule. The estimated price range is between 0 and 25,000 dollars, though bids equal to or greater than 25,000 dollars require a 20 percent bid bond guarantee and subsequent performance and payment bonds from an A-rated surety company. Submission requirements include a bid sheet, proof of insurance, three comparable project references, and a completed supplier packet containing a W-9 and self-certification of business size under FAR 52.219-8. Contractors must comply with Davis-Bacon Act prevailing wage rates for Washoe County and adhere to FAR 52.204-10 reporting if the award reaches 40,000 dollars. Final payment is contingent upon a successful final inspection and the submission of a notice of final completion, certified payroll reports, and operation and maintenance manuals.
Sierra Nevada Job Corps Center

POSTED

about 13 hours ago

DEADLINE

in 12 days
NAICS: 238220
New
This is a subcontracting opportunity to replace a chiller in McKinney, TX.
Solicitation # subcontracting-opportunity-replace-chiller-mckinney-tx
Serrato Corporation is seeking bids for a subcontracting opportunity to replace a failing air-cooled chiller at the North Texas Job Corps Center, specifically within Building 214/215 in McKinney, Texas. The scope of work includes the demolition and disposal of the existing chiller, the installation and startup of a new air-cooled chiller, and the integration of building automation controls using a JACE 9000 central integration point. Additionally, the contractor is responsible for installing three-way control valves at four air handling units, replacing VFDs, performing AHU cleaning and inspection, and ensuring all wiring is plenum-rated. Bids must be submitted by September 18, 2026, and quotes must remain valid for 90 days. Required submission documentation includes manufacturer equipment specifications, a Certificate of Liability Insurance naming Serrato Corporation as the holder, and Form 1413 for Davis-Bacon Act certified payroll compliance for work exceeding 2,000 dollars. Insurance requirements include a minimum of 500,000 dollars for Employers Liability and 1,000,000 dollars per occurrence for Commercial General Liability. The project is set aside for various small business categories, including SDB, WOSB, HUBZone, VOSB, and SDVOSB. Primary points of contact for this solicitation are Stacy Smith and Roy Henderson.
Serrato Corporation DBA North Texas Job Corps

POSTED

about 13 hours ago

DEADLINE

in 7 days
NAICS: 238220
New
Main Building 1 Wing 5 – Six Rooftop HVAC Unit Replacement – Glenmont Job Corps Center
Solicitation # S26-010
The Glenmont Job Corps Center is soliciting proposals from qualified, New York State licensed contractors for the replacement and installation of HVAC equipment within Main Building No. 1, Wing 5 (Education Building) in Glenmont, New York. The project involves replacing two 7.5-ton split-system units for the auditorium, one 6-ton rooftop unit for the library and computer lab, and one 12.5-ton rooftop unit for the north and east wing classrooms. Additionally, the scope includes installing four 2-ton ductless mini-split heat pump systems, removing a window air-conditioning unit, and abandoning two 5-ton rooftop units in place. Comprehensive associated work encompasses demolition, roof curbs and penetrations, ductwork, refrigerant and condensate piping, electrical work, controls, structural roof evaluations, and fire alarm and duct smoke detector installations, concluding with testing, balancing, and commissioning. This solicitation is set aside for various small business categories, including SDB, WOSB, HUBZone, and Veteran-Owned Small Businesses. The project must be completed within 210 calendar days following the written Notice to Proceed, and the facility will remain operational throughout the construction period. Key deadlines include a pre-proposal site walkthrough on September 10, 2026, with vendor questions due by September 14, 2026. Final proposals must be submitted by September 21, 2026, at 4:00 PM ET. All work must comply with applicable New York State codes, safety regulations, and environmental requirements.
Adams and Associates, Inc.

POSTED

about 13 hours ago

DEADLINE

in 10 days
NAICS: 238220
New
Replace HVAC Systems in the following buildings on our campus –1.) ABL Dormitory
Solicitation # 26-141
This subcontracting opportunity, managed by Adams & Associates, Inc. for the U.S. Department of Labor, involves the replacement of HVAC systems at the Atterbury Job Corps Center ABL Dormitory in Indiana. The project requires replacing existing R-22 Bryant condensing units and coils serving common areas and dormitory wings A, B, C, and D with new 12.5 SEER packaged units utilizing non-R22 refrigerants such as R-410A or R-454B. The contractor is expected to reuse existing electrical disconnects, ductwork, and thermostat wiring, and must label and leave all recovered refrigerant on-site. Bidders must attend a mandatory site visit on September 23, 2026, and submit a single lump sum proposal by October 5, 2026. Award will be based on best value, evaluating price (60 points), quality (20 points), past performance (10 points), and schedule (10 points). Eligible vendors must maintain an active SAM.gov registration and a Unique Entity ID, hold a valid Indiana Contractor's License, and provide proof of specific automobile and workers' compensation insurance. Compliance with EPA, OSHA, and Davis-Bacon Act wage determinations is mandatory. Final payment is subject to Net 30 terms and is contingent upon the submission of a completed SF 1413, certified payroll records, and the release of liens from all subcontractors and material suppliers.
Adams & Associates, Inc.

POSTED

about 13 hours ago

DEADLINE

in 23 days

AI Contract Overview

Show more

This solicitation, identified as FY261222006, is a 100% Small Business Set-Aside for the replacement of the LAN HVAC system at the International Boundary and Water Commission’s El Paso Headquarters located at 4191 N. Mesa, El Paso, TX 79902. The requirement is classified under NAICS code 238220 with a small business size standard of $19.0 million in average annual receipts, and only offers from certified small businesses will be considered. The procurement follows FAR Subpart 12.6 as a combined synopsis and solicitation for commercial items, issued as a Request for Quote (RFQ) with no separate written solicitation. Bidders must submit quotes for all CLINs as a single, complete offer—accepting the requirement on an “ALL or NONE” basis—and must include an active Unique Entity Identifier (UEI). Quotes must remain valid for 90 days and be submitted via email to angelica.baca@ibwc.gov no later than 3:00 p.m. MST on May 6, 2026, with questions limited to submissions received by May 1, 2026. The government will award using the Lowest Price Technically Acceptable (LPTA) method, prioritizing technical acceptability before price evaluation. Technical proposals must include a detailed narrative covering the plan of action, equipment specifications, key personnel, and schedule, along with at least three verifiable references of similar past projects, including contact details and project descriptions. All equipment must meet a 23 kW cooling capacity requirement (corrected from an earlier erroneous 23-ton specification), utilize R-410A refrigerant, operate on 460V 3-phase power, and achieve a minimum EER of 10.0. Brand-specific equipment is not required; equivalent alternatives are acceptable provided they meet all technical specifications, integrate with existing infrastructure, and are submitted for technical review. Installation involves removing existing units, installing a motorized damper to interface with the existing Carrier HVAC, and connecting to the existing electrical system via a Triple 50A breaker on 480V, with line sets confirmed as operational but requiring flushing. The condenser resides on the third-floor roof and can only be accessed via crane from the southwest corner of the building, while the evaporator unit is in a server room on the second floor with elevator access constrained to

General Info

Small business set-aside for 23 kW LAN HVAC replacement at El Paso HQ using R-410A, 460V, EER 10+, LPTA award, all-or-nothing quote by May 6, 2026.

Agency

International Boundary And Water Commission: Us-Mexico → Internat Boundary And Water CommissionView Agency

NAICS

238220 - Plumbing, Heating, and Air-Conditioning ContractorsView NAICS

Place of Performance

El Paso, TX, 79902, USA

Set-Aside

SBA

Documents

(5)

Applicable+Terms+and+Conditions.pdf

PDF

CLIN+Structure.docx

DOCX

FY261222006 LAN HVAC System Replacement Scope of Work

PDFsow

Updated+SOW_LAN+HVAC+Replacement_updated+04.29.2026.pdf

PDF

Site+Visit+Sign-in+04.24.2026.pdf

PDF

AI Contract Breakdown

Uniform Contract Format

Sign up to view the full breakdown with detailed analysis of each section.

Timeline

8 updates
PhaseClosed
Posted

Combined Synopsis

Amendment 1

Contract was updated

Amendment 2

Contract was updated

Amendment 3

Contract was updated

Amendment 4

Contract was updated

Amendment 5

Contract was updated

Amendment 6

Contract was updated

Amendment 7

Contract was updated

Amendment 8

Contract was updated

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Start your free trial to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyInternational Boundary And Water Commission: Us-Mexico → Internat Boundary And Water Commission
Contacts2 people available
OfficeEl Paso, TX, 79902, USA
Organization / Agency
International Boundary And Water Commission: Us-Mexico → Internat Boundary And Water Commission
View Agency Profile
Office AddressEl Paso, TX, 79902, USA
Contacts
Angelica Baca
Seone Michael Jones

Full Description

Show more

This is a combined synopsis/solicitation for commercial items in accordance with the format in FAR Subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; quotes are being requested, and a written solicitation will not be issued separately.


The solicitation number is FY261222006. This solicitation is issued as a request for quote (RFQ) for LAN HVAC Replacement at El Paso, HQ, 4191 N. Mesa, El Paso, TX 79902.


This is a 100% Small Business Set Aside. Only offers from Small Businesses will be considered for this solicitation.


The associated North American Industry Classification System (NAICS) code is 238220 – Plumbing, Heating, and Air-Conditioning Contractors. Product of Service Code for this requirement is N041–Installation of Equipment-Refrigeration, Air Conditioning, and Air Circulating Equipment. The Small Business Administration (SBA) size standard for this sector is $19.0 Million.


Services shall be quoted ALL or NONE as per CLIN structure and SOW attached. CLIN structure needs to be returned with your quote via e-mail directly to my attention at angelica.baca@ibwc.gov.


Quotes shall be good for 90 Days.


Offer due date/local time: May 6, 2026; 3:00 pm MST.


Only questions submitted by email to angelica.baca@ibwc.gov will be considered. Questions received from Offerors after 3p on May 1, 2026, may not be responded to.


Active UEI (Unique Entity Identifier) must be included in your offer.


Description: The International Boundary and Water Commission, United States Section (IBWC) requires LAN HVAC Replacement for El Paso HQ, 4191 N. Mesa, El Paso, TX 79902.


COR for this request: Antonio Almaguer (please do not contact him directly if you have any questions). All questions need to be directed to my attention.


Evaluation of Offer – The Government will award a contract resulting from this solicitation to the responsible offeror whose offer conforming to the solicitation will be most advantageous to the Government, price and other factors considered. The following factors shall be used to evaluate Offers: Technical acceptability to meet IBWC requirements; Technical Approach and Past Performance.


The Government will award a contract resulting from this combined synopsis/solicitation to the lowest price technically acceptable (LPTA), responsible offeror.


Technical Approach - Quote must demonstrate the technical approach by providing a narrative addressing all the items in the scope. The narrative shall at a minimum include your plan of action, equipment, key team members, and schedule.


Past Performance – Quotes shall demonstrate successful past performance of at least 3 three (3) references for similar projects. The information shall include name of person, company, phone number, email address, and brief description of the project.


Offerors shall meet or exceed and specifications and scope of work of items being quoted.


Offerors shall include a completed copy of the provision at 52.212-3, Offeror Representations and Certifications-Commercial Items, with its offer. NOTE: The offeror shall complete only paragraph (b) of this provision if the Offeror has completed the annual representations and certification electronically via the System for Award Management (SAM) website accessed at https://www.sam.gov.


END of combined synopsis/solicitation


Attachments:


CLIN Structure


Clauses and Provisions


Scope of Work


Modification 001 - 4/20/26 -  My client will be conducting a single site visit for all interested vendors, which is scheduled for April 24th from 9:00 to 10:00 a.m. Please note that this will be the only site visit available, so I encourage your team to attend during this time. Direct POC: Sebastian Calderon sebastian.calderon@ibwc.gov


Modification 002 - Q&A 4/21/26 -


Is the outdoor condensing unit on top of the roof? Yes


How many stories? 3 stories high and is the model corresponding to the Evaporative unit that we have in the Server room.


Are you using a third party such as Automated Logic for the  BMS Controls integration? The unit is controlled from the built-in console on the evaporative unit in the server room (servicing area) not part of the Building Automation System (BMS). 


Modification 003 - Q&A 4/22/26 - To include Technical Approach and Past Performance on solicitation description.


Modification 004 - Site Visit information 4/26/26:


-The server room is on the second floor accessible by elevator or stairs.


-Elevator capacity is 4000 lbs.; 4X7 ft door, Dimensions: 4ft W, 6.5ft L, 7.3ft H.


-Evaporator Unit in Server room with 3ft door access to hallway.


-Condenser on 3rd Floor Roof with Crane access only from SW corner of Bldg.


Modification 005 - Add Q&As below and attached Site visit sign in sheet - 4/28/26


  1. The Performance Specification lists the Liebert PX023UA1A809KM PDX Air-Cooled System as a 23-ton machine. However, according to the manufacturer, this model is a 23kW unit, which is approximately 6.5 tons. Could you please confirm if the requirement is for a 23-ton or a 6.5-ton machine?                                                                                    The reference to a “23‑ton” system in the Statement of Work was a clerical error. The correct requirement is 23 kW. All proposed equipment must meet the performance, environmental, and operational criteria associated with a 23 kW cooling system. This correction supersedes any earlier references in the SOW.                                                                                                                                                                                                                                                           2.    Does the client require the Liebert brand specifically, or may we propose an equivalent alternative?                   The agency does not require the Liebert brand specifically. Equivalent alternatives are acceptable; however, all proposed substitutes must:
    1. Meet or exceed all technical specifications outlined in the SOW,
    2. Demonstrate full compatibility with existing infrastructure,
    3. Include supporting documentation verifying equivalency, and
    4. Be submitted for agency technical review.                                                                                                  Please ensure that any proposed equipment aligns with the agency’s operational needs and long‑term support considerations.                                                                                                                                                                                                                                                                                                        3. The SOW in section 4. Performance Specification a “23 tons” HVAC unit but the Liebert PX023uA1A809KM model is rated at 23 kW (~6.5 tons). Please clarify are you expecting a 23 ton unit?   The reference to a “23‑ton” system in the Statement of Work was a clerical error. The correct requirement is 23 kW. All proposed equipment must meet the performance, environmental, and operational criteria associated with a 23 kW cooling system. This correction supersedes any earlier references in the SOW.                                                                                                                                4. Could you confirm the location of the electrical panel that feeds the indoor and outdoor Liebert units? The bid documents note reconnecting the new equipment to the existing electrical infrastructure, but I do not recall seeing the associated panel during the walk.                                                                            The 4x4 junction box next to the Liebert unit is labeled with “Panel H1, Circuit 20,22,24 480volts” the Breaker panel H1 is in 1st floor supply room, close to West exit door.  I do not have information on brakers to Condenser unit on the roof.
    5. The line sets specified for the new unit are the same size as the existing ones. Can you confirm whether the current lines can be reused? We understand they would still need to be properly flushed and cleaned. If replacement is required, could you provide approximate lengths from the indoor unit to the outdoor unit?                                                                                                                                                                Line sets are currently operational and in use                                                                                                                                                                                                                                                        Modification 006 - Update SOW attachment - 4/29/26                                                                                                                                                                                                                                    Modification 007 - 5/1/26 - Q&As below:                                                                                                  
    6. -Line set is currently operational and in use. Line set is currently operational and in use.


      -The server room is on the second floor accessible by elevator or stairs. The server room is on the second floor accessible by elevator or stairs.


      -Elevator capacity is 4000 lbs.; 4X7 ft door, Dimensions: 4ft W, 6.5ft L, 7.3ft H. Elevator capacity is 4000 lbs.; 4X7 ft door, Dimensions: 4ft W, 6.5ft L, 7.3ft H.


      -Evaporator Unit in Server room with 3ft door access to hallway. Evaporator Unit in Server room with 3ft door access to hallway.


      -Condenser on 3rd Floor Roof with Crane access only from SW corner of Bldg. Condenser on 3rd Floor Roof with Crane access only from SW corner of Bldg                                                                              The line sets specified for the new unit are the same size as the existing ones. Can you confirm whether the current lines can be reused? We understand they would still need to be properly flushed and cleaned. If replacement is required, could you provide approximate lengths from the indoor unit to the outdoor unit?                                                                                                                                                                Line sets are currently operational and in use                                                                                                                                                                                                                                                          Modification 008 - 5/2/26 - Q&As below:                                                                                                  

    7. Please confirm the required electrical capacity for the new Liebert unit (MCA and MOCP).
    8. Based on site observations, the existing wiring appears to be sized for approximately 60 amps (#6 conductors with 3/4" conduit).
    9. Please confirm if the existing electrical infrastructure is adequate, or if new feeders, conduit, or breaker upgrades will be required.                                                                                                                              The Unit is connected to a Triple 50A Breaker and is supplying 480 volts.  Wires and ¾ inch conduit were installed when we moved into this building somewhere around 2018/9.                                                                                                                                                                                                                                                                                                                                                                                                                                                                            









More opportunities from International Boundary And Water Commission: Us-Mexico → Internat Boundary And Water Commission

Same awarding agency

NAICS: 562119
New
Federal
Las Cruces Facility Sediment Disposal in the Rio Grande Canalization Project
Solicitation # 191BWC26R0011
Solicitation 191BWC26R0011 is a request for proposals for a firm-fixed-price contract to perform sediment disposal for the International Boundary and Water Commission at the Las Cruces Facility within the Rio Grande Canalization Project in Dona Ana County, New Mexico. The scope of work involves the loading, hauling, and spreading of stockpiled sediment from the Rio Grande channel banks to the Angostura Gravel Pit. This is a 100 percent small business set-aside under NAICS code 562119, requiring that the winning firm perform at least 51 percent of the volume removed with its own equipment. The period of performance is up to six months, with work typically aligned to the non-irrigational season between October and February. The government will award the contract based on the Lowest Price Technically Acceptable (LPTA) method, evaluating technical approach, valid experience via IBWC Forms 245 and 245B, and past performance. Key requirements for offerors include a two to three page technical narrative, three project references, and the provision of performance and payment bonds totaling 100 percent of the original contract price. Proposals must be submitted by September 14, 2026, at 3:00 PM Mountain Time. The contractor is responsible for all mobilization, including pre- and post-work topographic surveys and videos, and must adhere to environmental regulations, including the migratory bird season from March 1 to August 31. Payment will be processed electronically through the Invoice Processing Platform.
Other Waste Collection

POSTED

1 day ago

DEADLINE

in 3 days
View Details
NAICS: 334513
New
Federal
Nogales Instrumentation
Solicitation # 191BWC26R0018
The International Boundary and Water Commission is soliciting a firm fixed price turnkey contract for the procurement and installation of a complete Hach wastewater process instrumentation package at the Nogales International Wastewater Treatment Plant in Arizona. This unrestricted, brand name commercial acquisition requires the contractor to furnish genuine Hach sensors, SC4500 controllers, accessories, and one-year WarrantyPlus service coverage. The scope of work encompasses the entire lifecycle of the project, including equipment supply, installation, integration with the SCADA system, manufacturer startup, calibration, testing, training, and final turnover. The project covers several key plant areas, including the headworks, aeration basin, UV building, clarifiers, and the RAS line. Award will be determined using the Lowest Price Technically Acceptable (LPTA) evaluation method. Technical proposals will be rated as either Acceptable or Unacceptable based on factors such as the ability to provide genuine Hach products, the installation and integration approach, personnel qualifications, and the performance schedule. No tradeoffs between price and technical merit will be made, and exceeding minimum requirements will not provide additional value. All offers must be submitted via the secure Microsoft SharePoint portal by September 18, 2026, at 3:00 PM Mountain Time. The contractor is responsible for all labor, materials, and safety coordination, with invoicing processed through the Invoice Processing Platform.
Instruments and Related Products Manufacturing for Measuring, Displaying, and Controlling Industrial Process Variables

POSTED

3 days ago

DEADLINE

in 7 days
View Details
NAICS: 237990
New
Federal
Retamal Dam Buoy System
Solicitation # 191BWC26R0006
The International Boundary and Water Commission (IBWC) is soliciting a firm-fixed-price design-build contract for the Retamal Dam Buoy System in Hidalgo County, Texas. The project aims to establish a new waterway barrier line featuring anchors, an alert system, and warning signs to prevent public access to dangerous hydraulics and reduce structural impacts from debris. The scope is divided into two phases: the preparation of design documents and the subsequent construction and commissioning of the system. The estimated project magnitude is between 5 million and 10 million dollars, with a total performance period of 485 calendar days from the notice to proceed. The procurement follows a two-phase design-build selection procedure under FAR Subpart 36.3, where award is based on a rational tradeoff between cost and non-price evaluation factors, including technical plans, past performance, and financial condition. Bidders must meet strict qualification requirements, including the submission of IBWC Form 245 and evidence of professional licensure for design engineers. Site access is restricted to specific working hours, and contractors must coordinate with Border Patrol and avoid US Fish and Wildlife property. Proposals must be submitted exclusively via a secure SharePoint portal by the extended deadline of September 16, 2026.
Other Heavy and Civil Engineering Construction

POSTED

3 days ago

DEADLINE

in 5 days
View Details

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 650+ contractors already using CLEATUS