MARTINEZ REFINING COMPANY, LLC – Issuance of an Authority to Construct and PTO to alter S-1426 CCU, S-1427 CCU, Carbon Monoxide Boilers S-1507, S-1509, and S-15

Active
State & Local

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

General Info

Agency

California → Bay Area Air Quality Management District

NAICS

324110 - Petroleum RefineriesView NAICS

Place of Performance

Shell Avenue, Martinez, CA, 94553

Set-Aside

NONE

Documents

(1)

CEQA Notice of Exemption for Martinez Refining Company Permit Alterations

PDFnotice-of-exemption

AI Contract Breakdown

Uniform Contract Format

Sign up to view the full breakdown with detailed analysis of each section.

Timeline

Posted

forecast

Ready to pursue this opportunity?

Start your free trial to track this contract, build proposals with AI assistance, and manage your pipeline.

Organization & Contact Information

Show more
AgencyCalifornia → Bay Area Air Quality Management District
Contacts2 people available
OfficeN/A
Organization / Agency
California → Bay Area Air Quality Management District
Office AddressN/A
Contacts
Samuel DennisSenior Air Quality Engineer

Full Description

Show more
This permit action was to issue an Authority to Construct and Permit to Operate for the alteration of the following equipment to improve the overall reliability and reduce emissions due to maintenance and operational improvements: S-1426 CP Catalytic Cracking Unit (CCU) 79,500 barrels of gross feed per day; 25,421,700 barrels of gross feed per year Gross feed is the sum total of gas oil feed + rerun feed + slurry recycle CCU Regenerator CO emissions abated by CO boilers S-1507, 1509, 1512 S-1427 CP Catalytic Gas Plant (CGP) Located downstream of CCU and constrained by capacity of downstream relief valve S-1507 UTIL Carbon Monoxide (CO) Boiler 1 Maximum Operating Rate listed in Title V permit: 6,125 MMBtu/day (HHV); 2,235,625 MMBtu/year (HHV) Located downstream of CCU and abates CCU Regenerator CO emissions abated by A-12 Electrostatic Precipitator #1 Research Cottrell, GO-3101, 317,000 ACFM Located downstream of CCU and COB 1 and venting to atmosphere from emission point P-26 S-1509 UTIL Carbon Monoxide (CO) Boiler 2 Maximum Operating Rate listed in Title V permit: 6,125 MMBtu/day (HHV); 2,235,625 MMBtu/year (HHV) Located downstream of CCU and abates CCU Regenerator CO emissions abated by A-13 Electrostatic Precipitator #2 Research Cottrell, GO-3101, 317,000 ACFM Located downstream of CCU and COB 2 and venting to atmosphere from emission point P-27 S-1510 CP F-66 CCU Preheater Maximum Operating Rate: 4,286 MMBtu/day (HHV); 1,077,600 MMBtu/year (HHV) Located upstream of and preheats feed for CCU S-1512 UTIL Carbon Monoxide (CO) Boiler 3 Maximum Operating Rate listed in Title V permit: 6,125 MMBtu/day (HHV); 2,235,625 MMBtu/year (HHV) Located downstream of CCU and abates CCU Regenerator CO emissions abated by A-14 Electrostatic Precipitator #3 Research Cottrell, GO-3101, 317,000 ACFM Located downstream of CCU and COB 3 and venting to atmosphere from emission point P-28 MRC has proposed the following maintenance and operational improvements to the CCU (S-1426), CGP (S-1427), and COBs (S-1507, S-1509, and S-1512) under Application 698127: 1. CCU Regenerator Upgrades: Replacement of the regenerator column’s air grid and cyclones, as well as the addition of a steam quench system. 2. CGP Wet Gas Compressor Upgrades: Replacement of couplings, diaphragms, and rotor for compressor J-125, along with a replacement of the TB-152 steam turbine which drives the compressor, and new fugitive components in non-urea service. 3. Improvements to the CO Boiler Urea Injection system: Installation of a new pump for the system, moving the point of urea injection, and new fugitive components in urea service. Emissions from S-1426 are routed to the carbon monoxide boilers (COBs) S-1507, S-1509, and S-1512, which are abated by the electrostatic precipitators A-12, A-13, and A-14, respectively.

Similar Contracts

Same NAICS industry code

Ready to Pursue This Opportunity?

Get AI-powered intelligence on this solicitation and the ones like it

Every page of the solicitation package shredded into a compliance breakdown