Mojave Fish Hatchery - Water Well and Booster Station Equipment Upgrade

Active
State & Local

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

AI Contract Overview

Show more

The Mojave Fish Hatchery Water Well and Booster Station Equipment Upgrade project in Victorville, California, focuses on replacing end-of-life infrastructure to maintain operational efficiency. The scope of work includes the removal of an existing propane tank and concrete pad, the replacement of a 70-foot gravel road and 72-foot section of asphalt pavement, and the installation of four new bollards. Additionally, the project involves excavating for a new concrete pad and digging a 372-foot utility trench to replace the natural gas line with new electrical lines. Key equipment upgrades include the installation of a new G-W9 450KW generator and a master control panel. The project also requires the replacement of seven turbine pumps along with their associated mechanical and electrical components. This initiative is managed by the California Fish and Wildlife Headquarters, Wildlife and Fisheries Division.

General Info

Infrastructure upgrades at Mojave Fish Hatchery including generator, pumps, and electrical line installation.

Agency

California → Fish and Wildlife (Headquarters), Wildlife and Fisheries Division – Sacramento

NAICS

237130 - Power and Communication Line and Related Structures ConstructionView NAICS

Place of Performance

Jacaranda Ave and Mojave Fish Hatchery Rd, Victorville, CA, 92395

Set-Aside

NONE

Documents

(0)

No documents available

AI Contract Breakdown

Uniform Contract Format

No contract breakdown available.

Cannot generate Contract Breakdown because no documents were found from this contract's source.

Timeline

Posted

forecast

Ready to pursue this opportunity?

Start your free trial to track this contract, build proposals with AI assistance, and manage your pipeline.

Organization & Contact Information

Show more
AgencyCalifornia → Fish and Wildlife (Headquarters), Wildlife and Fisheries Division – Sacramento
Contacts2 people available
OfficeN/A
Organization / Agency
California → Fish and Wildlife (Headquarters), Wildlife and Fisheries Division – Sacramento
Office AddressN/A
Contacts
Stephanie ColemanSenior Environmental Planner
Russel BlackEnvironmental Program Manager

Full Description

Show more
The Water Well and Booster Station Equipment upgrade will replace equipment that has reached the end of it useful life at the Mojave Fish Hatchery in Victorville, CA. The project will: •Remove the existing propane tank and associated concrete pad; •remove, grade to existing, and replace the 2’ wide by 70’ long gravel road; •remove, grading to existing, and replace 2’ wide by 72’ asphalt pavement •remove existing bollards •Excavate approximately 20’ by 8’-2” by 24” to construct a new concrete pad, •Excavate utility trench to remove the existing natural gas line and install new electrical lines, then backfill the approximately 372’ long and 3’ deep and install 4 new bollards. •Install new G-W9, 450KW generator. •Install new master control panel. •Replace 7 turbine pumps and the associated electrical and mechanical components

Similar Contracts

Same NAICS industry code

NAICS: 237130
New
Federal
Z--Sand Island Photovoltaic System Renovation
Solicitation # 140L5726Q0029
The Bureau of Land Management Utah State Office is soliciting quotes for the Sand Island Photovoltaic System Renovation at the Sand Island Ranger Station near Bluff, Utah. This firm-fixed-price construction contract is a total small business set-aside under NAICS 237130, with an estimated value between 25,000 and 100,000 dollars. The project requires a complete renovation of the existing photovoltaic system, including the replacement of the battery bank, inverters, and controls, as well as the installation of a minimum 4800W bifacial PV array. Additionally, the contractor must provide a written assessment and recommendations for restoring the backup power capacity of the existing fossil fuel generator. All work must be completed within a 30-day performance period following the Notice to Proceed. Award will be determined using a best-value trade-off approach, where technical factors—including past performance, technical ability, and project schedule—are collectively considered more important than price. Proposals must be submitted via email by August 25, 2026, and must be divided into separate price and technical volumes. The contractor is required to maintain active SAM registration, comply with Buy American requirements, and adhere to Davis-Bacon Act wage rates. All payment requests must be processed electronically through the Invoice Processing Platform. Key technical requirements include the use of UL-certified batteries and Victron 5kW charge controllers or approved equals, with all systems carrying full manufacturer warranties.
Utah State Office

POSTED

about 21 hours ago

DEADLINE

in 3 days
View Details