Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, September 16 at 2:00 PM EDT

Register Free →

This Sources Sought opportunity from Department Of The Interior was posted on June 22, 2026. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

N--Request for Information/Sources Sought Synopsis for Market Research Purposes On

Closed
DOIGFBO260022Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 333415
New
Federal
49 FSS Dining Facility Commercial Freezer
Solicitation # F2E3RM6153A001
The 49th Force Support Squadron at Holloman Air Force Base, New Mexico, is soliciting the purchase and installation of a commercial walk-in freezer for the Shifting Sands Dining Facility. The required unit must have interior dimensions of 10 by 16 by 8 feet 6 inches, a holding temperature of -10 degrees Fahrenheit, and a 26GA G90 galvanized steel finish. Key technical specifications include a three-phase electrical system, remote preassembled refrigeration with a condensing unit located at least 60 feet from the freezer, and aluminum diamond treadplate on the floor, lower walls, and door interior. The unit must also include an integrated temperature monitoring device and an exterior door ramp. The contractor is responsible for the full scope of work, including site preparation through the construction of a concrete slab foundation, on-site assembly, refrigeration piping, and final commissioning. While base Civil Engineering will handle the final electrical hookup, the vendor must provide all unloading support as no forklifts or cranes are available at the delivery site. This is a total small business set-aside under NAICS code 333415. Interested vendors must provide separate costs for freight, shipping, delivery, and setup. Delivery is requested as soon as possible during normal business hours, and personnel must be eligible for base access with visitor requests submitted 24 hours in advance.
FA4801 49 Cons Pk

POSTED

1 day ago

DEADLINE

in 2 days
NAICS: 333415
New
Federal
Prop Air Cooled Condensing Unit P: 208/230V - 1Ph 3 EA - 60Hz Brand Name Liebert Model PFH014CPLN or Equal
Solicitation # 1232SA26Q0934
Solicitation 1232SA26Q0934 is a combined synopsis and request for quotation issued by the USDA Agricultural Research Service for the procurement, removal, and installation of three Prop Air Cooled Condensing Units for the Sugarcane Research Unit in Schriever, Louisiana. The requirement specifies Liebert Model PFH014CPLN units or an approved equal that meets the same salient physical and functional characteristics, including compatibility with DataMate systems, 208/230V 1Ph 60Hz power specifications, and the ability to operate in temperatures as low as -30°F. The scope of work includes the removal and disposal of existing units and the installation of new units field-charged with R-407C refrigerant. This is an unrestricted acquisition under NAICS code 333415, and award will be made to the lowest price technically acceptable offeror. Technical acceptability is based on the ability to provide the specified equipment, a Certificate of Conformance per FAR 52.246-15, and documented OEM traceability. All items must be delivered FOB destination within 60 days of the order receipt. Offerors must hold their pricing firm for 90 calendar days. The contract incorporates standard federal clauses including Buy American preferences, Service Contract Act wage determinations for Louisiana, and strict compliance with federal anti-discrimination and ethics regulations. Invoices must be submitted electronically through the Invoice Processing Platform.
USDA Ars Afm Apd

POSTED

1 day ago

DEADLINE

in 5 days

AI Contract Overview

Show more

The U.S. Department of the Interior, via the U.S. Geological Survey, is conducting market research through a Request for Information to identify qualified contractors capable of designing, constructing, and commissioning a new air-cooled chiller system at the Upper Midwest Environmental Sciences Center in La Crosse, Wisconsin. The project aims to replace two existing water-cooled chillers—one active and one discontinued—with a dual-unit air-cooled system featuring remote evaporators installed indoors in Room C-111m, while the outdoor units are to be ground-mounted on the east side of Segment B. Each chiller must deliver 160 to 180 tons of cooling capacity using scroll compressors, and the entire system must be manufactured as an integrated unit with matched components, eliminating the need to drain chilled water lines for winterization. Noise levels must comply with ANSI/AHRI Standard 370-2025, operating within a 60–80 dBA range, and all chilled water piping must be reconfigured to connect to the new remote evaporators while respecting existing electrical infrastructure and site constraints related to proximity to the building, parking, and loading zone. The estimated project value ranges between $750,000 and $1.5 million, and contractors are expected to manage full design, construction, and commissioning including mechanical, electrical, and controls work, while adhering to Wisconsin licensing requirements for electricians and plumbers. Vendors must submit organizational details, tailored capability statements, estimated schedules, rough order of magnitude costs, and verifiable examples of comparable past projects including customer references. All responses are voluntary, non-binding, and will not be reimbursed or acknowledged, serving only as input for future procurement planning. No solicitation currently exists, and any subsequent RFP will be posted exclusively on SAM.gov. Submissions are due by July 17, 2026, and must be sent via email to the designated contract specialist. The RFI, issued under FAR 52.215-3, explicitly states that responses do not obligate the government to award a contract and do not affect eligibility for future opportunities.

General Info

U.S. Geological Survey seeks vendors for air-cooled chiller system replacement at La Crosse, WI, costing $750K–$1.5M.

Agency

Department Of The Interior → Ofc Of Acquisition Grants-DenverView Agency

NAICS

333415 - Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment ManufacturingView NAICS

Place of Performance

CO

Set-Aside

NONE

Documents

(1)

UMESC Cooling Systems RFI for Market Research

PDFrfi

AI Contract Breakdown

Uniform Contract Format

Sign up to view the full breakdown with detailed analysis of each section.

Timeline

PhaseClosed
Posted

Sources Sought

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Start your free trial to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of The Interior → Ofc Of Acquisition Grants-Denver
Contacts1 person available
OfficeDENVER, CO, 80225, USA
Organization / Agency
Department Of The Interior → Ofc Of Acquisition Grants-Denver
View Agency Profile
Office AddressDENVER, CO, 80225, USA

Full Description

Show more
This amendment attaches the RFI that was inadvertently left out.

Request for Information/Sources Sought Synopsis for Market Research Purposes Only for Cooling Systems

The U.S. Department of Interior (DOI), US Geological Survey (USGS) is issuing this Request for Information (RFI) as a means of conducting market research to identify parties having an interest in, experience, and the resources to support this requirement for the potential need for services.

In accordance with Federal Acquisition Regulation (FAR) 52.215-3, Request for Information for Solicitation and Planning Purposes (October 1997), this notice is issued solely for information and planning purposes only. It does not constitute a Request for Proposal (RFP). The DOI, USGS intends to assess the responses to include in its decision-making. This notice is not to be construed as a commitment by the government to contract for services. The government will not pay for any information provided as a result of this notice and will not recognize or reimburse any cost associated with RFI submission. Responses to this RFI will not affect a potential offeror's ability to respond to any RFP that might follow. Please ensure that any sensitive or protected information is marked as such, as this information will be kept confidential except as provided by law.

The purpose of this RFI is to identify potential sources and gather information that will help in forming the solicitation to maximize competition and secure the best value outcome for the American taxpayer. Interested prospective contractors are invited to reply to any or all the following.

Background:
As part of an ongoing process to reduce facility water consumption, the Upper Midwest Environmental Sciences Center (UMESC) is planning on replacing multiple water-cooled chillers serving Segments A, B and C of the main building Heating, Ventilation, and Air Conditioning (HVAC) systems with air-cooled units.

Segments A, B and C chilled water is currently provided by a Multistack Maglev water cooled chiller (Model MS0292FC1M2W2H1CC66FL-R134A) in Room C-111m. An additional Dedicated Heat Recovery Chiller (DHRC) chiller (Model MS030XC2H2H2AAC-R410A) located in the same room is no longer used.

This project would involve removing both the Maglev unit and the DHRC unit and installing a new outdoor chiller system capable of providing sufficient cooling capacity to make up for any losses in system efficiency.

Due to risks of freezing weather, and because temperatures in transition months are highly variable, it is intended that the new system be configured to not require draining of the chilled water lines as a means of winterizing the chilled water loop to prevent damage to the new chiller or its primary piping circuit.

Scope of Services:
The estimated magnitude of this construction project is between $.75M and $1.5M.

To eliminate the need for draining the chilled water lines as part of winterizing the new system, interested parties may propose a new chiller system having the following salient characteristics: No alternatives shall be provided.

1. Air-cooled chillers with remote evaporators installed in C-111m mechanical space.
2. Chiller capacity to be split between 2 chiller units, each with 160-180 tons cooling capacity.
3. Chiller units to use scroll compressors.
4. Chiller and remote evaporator system shall be by the same manufacturer and intended by the manufacturer to be installed as one complete system.
5. All chilled water piping to be reconfigured and piped to new remote evaporators.
6. The existing chiller units are each served by separate 460v 400A disconnects.
7. There are no cooling components on the roof. It is expected that the outdoor units will be mounted on the ground on the east side of Segment B.
8. Noise limitations: 60-80dBa range as tested per ANSI/AHRI Standard 370-2025(SI/I-P)
9. Main space constraints: Distance from the building, parking lot and loading dock area and allowable distance of refrigerant lines (determined by chiller manufacturer).


It is the intent of the Government that the interested parties shall be responsible for the entire design, construction and commissioning of the requirement, including site preparation, general construction, mechanical, electrical, controls and systems commissioning. As such, interested parties shall include capabilities as pertaining to design and layout of refrigeration and chilled water systems, and any specific partnerships with architect/engineering firms and manufacturers in addressing specific issues related to refrigerant piping layout, system sizing and sitting of remote evaporator chiller equipment.

Vendors shall include references to systems where the vendor's proposed configuration was successfully implemented, including location, size of the system, chiller manufacturer, installation year, and customer contact information.

Please provide a rough estimate of the cost, consisting of engineering costs; capital equipment cost, including installation; and operating cost.

To ensure quality work and maximize employee safety, we intend to follow all State of Wisconsin contractor licensing/registration requirements. For example, Wisconsin statute 101.862 requires licensed electricians and 145.06 requires licensed plumbers. Please identify any other trade licensing requirements or general contractor licensing requirements we should be aware of.

Location:
Upper Midwest Environmental Sciences Center
2630 Fanta Reed Road
La Crosse, WI 54603

Point of Contact:
Beth Wilson, Contract Specialist, beth_wilson@ios.doi.gov.

THERE IS NO SOLICITATION AT THIS TIME; therefore, do not request a copy of the solicitation. If a solicitation is released it shall be synopsized in the Government's SAM website (https://sam.gov). It is the potential offerors' responsibility to monitor these sites for the release of any solicitation or synopsis.

Submission of any information in response to this RFI is purely voluntary. Respondents will not be notified of the results of the evaluation. The result of this market research will contribute to determining the method of procurement.

Submittals:
If your organization can meet this requirement, please provide:
1. Organization name, address, email address, Web site address, telephone number, and size and type of ownership for the organization.
2. Tailored capability statements addressing the particulars of this effort, with appropriate documentation supporting claims of organizational and staff capability. If significant subcontracting or teaming is anticipated in order to deliver technical capability, organizations should address the administrative and management structure of such arrangements.
3. Scope of services.
4. Estimated project schedule.
5. Rough order of magnitude cost separately for each of the proposed services. (Any expenses including travel, lodging and other reimbursable expenses shall be included in the fee for the proposed services.
6. Examples of your team's previous successful project (if available)

More opportunities from Department Of The Interior → Ofc Of Acquisition Grants-Denver

Same awarding agency

NAICS: 811121
New
Federal
CUSTOM MOBILE FIELD LABORATORY VAN BUILD
Solicitation # 140G0226Q0173
The Department of the Interior, through the USGS OAG Denver Acquisition Branch, is soliciting a firm fixed price contract for the custom build-out of a mobile field laboratory van to support the Colorado Water Science Center - Pueblo. This total small business set-aside requires the contractor to provide all non-personal commercial services, including labor, materials, equipment, and supervision, to deliver a fully operational mobile lab by March 31, 2027. The scope of work involves a comprehensive build-out featuring specific installations such as RV-standard sinks, CODT-standard flashing LED marker lights, and various electrical and water tank components as detailed in the technical exhibits. The final product must be delivered FOB Destination to the Colorado Water Science Center in Pueblo, Colorado. Award will be granted based on the lowest priced technically acceptable offer. To be considered technically acceptable, offerors must submit technical brochures and specifications proving that all proposed equipment meets the minimum required characteristics. All components must be authentic, manufacturer-certified, and delivered in original packaging, with a strict prohibition on gray market or counterfeit items. Payment will be processed electronically via the Invoice Processing Platform. The procurement is managed by Contracting Officer Jennifer Rollin, and final acceptance is contingent upon inspection by the Administrative Point of Contact to ensure the build meets all specified technical requirements.
Automotive Body, Paint, and Interior Repair and Maintenance

POSTED

1 day ago

DEADLINE

in 6 days
View Details
NAICS: 238220
New
Federal
N--NEIC REPLACEMENT CRAC
Solicitation # 140G0226Q0098
Solicitation 140G0226Q0098 is a firm-fixed-price construction contract issued by the USGS Denver Acquisition Branch for the replacement of a faulty Computer Room Air Conditioner (CRAC) unit at the GHSC Data Center in Denver, Colorado. This total small business set-aside under NAICS 238220 requires the contractor to decommission and dispose of the existing unit and install a new system, including integration with electrical and chilled water or direct expansion infrastructure. The project must adhere to ASHRAE TC 9.9.12 environmental guidelines, and the contractor is permitted to use factory-certified refurbished units provided the refrigerant has a global warming potential below 700. The period of performance is scheduled from September 28, 2026, to November 29, 2026, though this may be adjusted for equipment lead times. Award will be based on the Lowest Price Technically Acceptable (LPTA) process, with technical acceptability evaluated on a pass/fail basis. Key evaluation factors include the installation plan for an active computer room, a Testing, Adjusting, and Balancing (TAB) plan, and a demonstrated history of HVAC installations in mission-critical environments. The contractor must comply with Davis-Bacon Act wage determinations for Jefferson County and provide performance and payment bonds within ten days of award. Proposals are due by September 17, 2026, and must include a technical response limited to five pages and a detailed price proposal. Invoicing is managed through the IPP website on a monthly basis.
Plumbing, Heating, and Air-Conditioning Contractors

POSTED

2 days ago

DEADLINE

in 5 days
View Details

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 650+ contractors already using CLEATUS