THIS IS A SOURCES SOUGHT NOTICE, NOT A SOLICITATION OR OFFER TO PURCHASE. IT IS FOR MARKET RESEARCH PURPOSES AND IS INFORMATIONAL ONLY. NOTE: THIS SOURCES SOUGHT NOTICE IS FOR SMALL BUSINESSES, CERTIFIED 8(a) SMALL BUSINESSES, CERTIFIED HUBZONE SMALL BUSINESSES, CERTIFIED SERVICE DISABILED VETERAN-OWNED SMALL BUSINESSES and/or WOMAN-OWNED SMALL BUSINESSES. The National Park Service (NPS), Denver Service Center, 12795 W. Alameda Parkway, Denver, Colorado seeks to determine the availability and capability of potential SMALL BUSINESSES, CERTIFIED 8(a) SMALL BUSINESSES, CERTIFIED HUBZONE SMALL BUSINESSES, CERTIFIED SERVICE DISABLED VETERAN-OWNED SMALL BUSINESS, and/or WOMAN-OWNED SMALL BUSINESSES for the project below. Project Name: NAMA 216036 185966 - Restore Jefferson Memorial Roof and Portico Location: National Mall and Memorial Parks, Washington D.C. Estimated Magnitude: Over $10,000,000.00 Project Description The Jefferson Memorial (constructed between 1939 and 1943) is one of the Nation's prominent, and one of the most famous cultural resources in the National Park system. The memorial was individually listed on the National Register of Historic Places in 1981 and is also listed as a contributing structure on the East and West Potomac Parks National Historic District, 1999. This project would encompass the restoration of the portico roof, portico ceiling, and replacement of the roof systems along the colonnade and upper roof, and the associated repairs to the stone along the architrave. The project will be broken down into two components to complete the work: Component A: 1) Repair the leaking Portico roof tile, pediment stone and water proofing system to prevent further water infiltration of the attic interior which has already occurred and created a structural failure to the Portico ceiling system. 2) Replace the damaged and missing stone coffers/beams of the portico ceiling with the associated structural system that has already has or is about to fail. This work includes replacement of Portico Ceiling Lights, creating an access to the Portico attic space, repair of capital volutes, and mortar repointing of stone and other related work. All stone surfaces associated with this repair will be re-grouted and cleaned at the completion. Component B: Replace the membrane roof and flashing systems along the flat colonnade and upper roof sections. The current roofing has exceeded the lifespan for membrane roof system, which was originally installed in 1994. The current roof membrane has already shown signs of failure. There are signs of water infiltration at the architrave along the colonnade with constant water flows through the stone joints during rain storms and the formation of icicles during cold weather seasons. This work includes modification and upgrade of the structures existing security cameras and related cabling, repairs and cleaning of damaged stone surfaces, as well as laser cleaning of the Dome, Portico roof and cornices, and other related exterior stone surfaces of biofilm. Required Capabilities 1. Demonstrate experience in the repair and restoration of historic stone building components, and the repair and replacement of stone tile roof and flat roof membrane systems. 2. Demonstrate past performance in meeting or exceeding customers' expectations while complying with Federal, State, and Local laws and regulations and successfully obtaining and expediting permits from Washington, DC permitting offices. 3. Demonstrate past performance in maintaining and working within a secure construction site, requiring background checked and badged workers and subcontractors, canine delivery inspections and the ability to work with U.S. Park Police providing for onsite security. The project includes gated entry with security checkpoint. 4. Demonstrate past performance related to working in and adjacent to a historic structure - protecting multiple architectural resources and site. Demonstrate past performance and experience with developing, executing, and maintaining a protection plan for these resources that is in compliance with "The Secretary of the Interior's Standards for the Treatment of Historic Properties" for a project of similar scale. 5. The requirement to maintain a clean, orderly, and organized work site in constant and strict adherence to all regulatory and NPS requirements in a highly visible work location which will subject the contractor's operations to daily oversight from the highest levels of government and daily interaction with the general public visiting the site. 6. The requirement to prepare and implement a logistics plan with safe and functional scheduling and routing of visitor flows around the site. The NAICS Code for this requirement is 236220 Commercial and Institutional Building Construction with a corresponding size standard of $36.5 million gross receipts, averaged over the preceding 3 years. The size of a small business firm includes all parents, subsidiaries, affiliates etc. see 13 CFR 121.103 and 13 CFR 121.108 All firms should be certified in SAM https://www.sam.gov. The following Limitations on Subcontracting apply to each category as follows: - Small: In accordance with FAR clause 52.219-14, at least 15% of the cost of contract performance incurred for personnel shall be expended for employees of the concern. - 8(a): In accordance with FAR clause 52.219-14, at least 15% of the cost of contract performance incurred for personnel shall be expended for employees of the concern. - HUBZone: In accordance with FAR clause 52.219-3, at least 15% of the cost of personnel for contract performance will be spent for employees of the concern or employees of other HUBZone small business concerns. - Service Disabled Veteran-Owned: In accordance with FAR clause 52.219-27, at least 15% of the cost of personnel for contract performance will be spent for employees of the concern or employees of other service-disabled veteran-owned small business concerns. - Women-Owned: In accordance with FAR clause 52.219-30, the concern will perform at least 15% of the cost of the contract incurred for personnel with its own employees. In order to be considered capable for award of this acquisition, firm(s)/teams must demonstrate the ability to perform within the Limitation on Subcontracting requirements listed above. Firms responding to this notice must submit a narrative, not exceeding eight (8) pages, addressing the following: - Description of how capability requirements above will be met. - Brief past performance information on projects of a similar scope and magnitude. - Percentage and description of self-performed work over the previous five (5) years. - IMPORTANT: Identification/certification of business size and socio-economic group, i.e. certified HUBZone business, certified 8(a) business, certified Service Disabled Veteran-Owned small business, woman-owned business, or small business. - A letter from your bonding company verifying bonding capability that aligns with the estimated magnitude of construction. - Firm's name, DUNS number and CAGE Code. All firms responding to this sources sought shall keep responses to a maximum of ten (10) pages including the cover sheet, if any. Your response is due no later than 1200 Mountain Time on Thursday, February 15, 2018. Responses shall be submitted by email only with a subject including the phrase "NAMA 216036 185966" to the following email addresses: karen_labouff-kind@nps.gov timothy_burger@nps.gov The information received as a result of this market research will be considered solely for the purpose of determining whether to conduct a competitive procurement under one of SBA's socioeconomic business programs. The NPS does not intend to pay for any information provided under this notice.