ODOC - FY25 - SCBA Packs, Bottles, Regulators & Masks
Contract Overview
Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.
Active Opportunities Like This One
AI Contract Overview
The Ohio Department of Commerce is soliciting proposals for the comprehensive procurement of Self-Contained Breathing Apparatus (SCBA) equipment for the Ohio Fire Academy (OFA). This initiative aims to design, manufacture, test, and supply SCBA units that ensure training safety and efficacy by adhering to strict regulatory standards. The contract particularly emphasizes the acquisition of Scott's Branded products to maintain compatibility with the academy's existing apparatus, pivotal for live fire instruction. A key feature of the contract is outfitting the academy with high-performance SCBA systems that include full facepiece assemblies, air-saver switches, redundant pressure reducers, and various components like harnesses, back frames, and alert systems, ensuring compliance with NIOSH and NFPA specifications. In detail, the vendor is tasked with delivering 20 Air-Pak X3 Pro SCBA units, 50 carbon-wrapped cylinders rated at 4500 psig, 10 E-Z Flo+ regulators, and 20 high-temperature SCBA masks in multiple sizes. The contract envisions a robust structure where the SCBA systems integrate essential components such as pressure regulators, end-of-service indicators, and rapid intervention connections, all within a durable assembly designed for rigorous fire training environments. The performance period extends until October 31, 2025, with the specified delivery location being the Division of State Fire Marshal Office in Reynoldsburg, Ohio. With a financial scope capped at $300,000, this procurement, categorized under the SLED Contract Opportunity, is bound by a fiscal framework that aligns with the state’s budgetary provisions and operational exigencies, further ensuring thorough oversight and execution of fire safety training endeavors.
General Info
Place of Performance
OH, USASet-Aside
Documents
1AI Contract Breakdown
Uniform Contract FormatContract not broken down yet
CLEATUS splits the solicitation into Uniform Contract Format (UCF) sections: scope, pricing, deliverables, and evaluation criteria.
This one is closed. Find the next one like it.
Open contracts like this one, right now:
- Janitorial ServicesOpen now, due in 25 days
- Pikes Peak Janitorial Base plus 4Open now, due in 14 days
Ask CLEATUS
I've read this contract. Ask me anything.
Timeline
Submission Closed
Organization & Contact Information
Full Description
2.1 Self-Contained Breathing Apparatus Requirements (20 units total): The SCBA shall consist of the following significant sub-assemblies:
(1) full facepiece assembly.(2) a removable, positive pressure, mask-mounted regulator with an air-saver switch.(3) an automatic dual path redundant pressure reducer;(4) end-of-service time indicators.(5) a harness and back frame assembly for supporting the equipment on the body of the wearer; (6) a shoulder strap-mounted remote gauge indicating cylinder pressure.(7) a rapid intervention crew/universal air connection (RIC/UAC);(8) a personal alert safety system (PASS); and(9) cylinder and valve assembly for storing breathing air under pressure.2.2 Regulatory Approvals The SCBA shall be approved, according to NIOSH 42 CFR, Part 84, as an open-circuit, pressure-demand self-contained breathing apparatus. The SCBA shall be certified to NFPA 1981, Standard on Open-Circuit Self-Contained Breathing Apparatus for Emergency Services, 2018 Edition. When configured with a PASS device, the SCBA shall be certified to NFPA 1982, Standard on Personal Alert Safety Systems, 2018 Edition. The SCBA shall be compatible with an optional firefighter escape belt that is compliant with NFPA 1983, Standard on Life Safety Rope and Equipment for Emergency Services, 2017 Edition. All components shall be approved for intrinsic safety under UL 913, Class I, Groups C and D, Class II, Groups E, F and G, and hazardous locations. The SCBA shall maintain all NIOSH standards with any of the types of cylinders listed as provided by the SCBA manufacturer
3.0 Facepiece Assembly (Model: AV-3000 HT) The facepiece shall have a large diameter inlet that enables both unrestricted breathing and voice communication while also allowing for rehydration (oral) without having to remove the facepiece. The facepiece shall enable connection of the mask-mounted regulator by way of a quarter (1/4) turn rotation. The facepiece shall interface with the mask-mounted regulator, without the use of tools, with an audible click to assure the user that the regulator is properly seated. The full facepiece assembly shall be available in three sizes, marked “S” for small, “M” for medium, and “L” for large. The facepiece sizes shall be color-coded for ease of identification. The facepiece nose cup assembly shall be available in three sizes, marked “S” for small, “M” for medium, and “L” for large. The facepiece assembly, including the head harness, shall not be made with natural rubber latex. The facepiece shall include a face seal secured to the lens by a U-shaped bezel using no more than two fasteners. The facepiece shall contain inhalation valves that are contrasting in color and readily visible to enable quick visual inspection. Multi-directional voicemitters shall be recessed on both sides of the facepiece and ducted directly to an integral silicone nose cup to enhance voice transmission around the user. The facepiece shall meet the requirements of the NFPA 1981, 2018 Edition standard for nonelectronic communications. The facepiece assembly shall be modular in design, enabling ease of upgrading and serviceability. The facepiece shall be capable of submersion for cleaning and disinfecting. The facepiece shall be able to incorporate multiple electronic communications options (amplification, radio interface, radio direct interface) without affecting NIOSH approvals and/or NFPA certification, where applicable. The facepiece shall enable the installation of a communications bracket on either the right or left side. The facepiece shall be approved for use with multiple respiratory applications (e.g., airline respirator or negative pressure respirator with filters/cartridges) to enable the same user to switch from one application to another without the use of tools and without doffing the facepiece.
3.1 Facepiece Lens The lens is a component of the facepiece assembly. It shall be a single, replaceable, modified-cone configuration constructed of a high-temperature, radiant-heat-resistant, non-shatter polycarbonate material. The lens shall be coated to resist abrasion and meet the requirements of the NFPA 1981, 2018 Edition standard for lens abrasion. The lens shall have an internal anti-fog coating to reduce fogging of the lens. The lens shall meet the requirements of the NFPA 1981, 2018 Edition standard for radiant heat, elevated temperature heat, and flame resistance tests. The facepiece shall meet the penetration and impact requirements of ANSI Z87.
3.2 Head Harness The head harness is a component of the facepiece assembly. It shall have five points of suspension connection, four of which shall be adjustable and made in the fashion of a net hood to minimize interference between securing the facepiece and wearing head protection. The head harness shall be available in an optional, adjustable five-strap configuration. The head harness shall be constructed of a para-aramid material for fire, first responder, and CBRN applications. The head harness shall include either a positioning strap or an integrated handle to assist with donning the facepiece. Two elastomeric straps, attached to the face seal in four locations, shall provide adjustment for proper seal to the face.
4.0 Regulator (Model: E-Z Flo+) The mask-mounted regulator shall maintain positive pressure during flows of up to 500 standard liters per minute. The mask-mounted regulator shall be available in a continuous hose configuration, with an optional inline quick disconnect coupling. The optional quick disconnect coupling shall be easily connected and disconnected by trained individuals with a gloved hand and in limited visibility conditions. The optional quick disconnect coupling shall be guarded against inadvertent disconnection during the use of the equipment. The low-pressure hose shall have a swivel attachment at the mask-mounted regulator. The mask-mounted regulator shall connect to the facepiece by way of a quarter (1/4) turn rotation. A latch mechanism shall lock the mask-mounted regulator in place to prevent inadvertent rotation. An audible click shall provide notification that the mask-mounted regulator is securely attached to the facepiece. The mask-mounted regulator shall be equipped with a gasket to provide a seal against the facepiece's mating surface. The mask-mounted regulator shall contain an air-saver switch to prevent airflow when disconnected from the facepiece. The mask-mounted regulator shall reactivate and supply air only in the positive pressure mode when the wearer affects a face seal and inhales. The mask-mounted regulator shall have a demand valve to deliver air to the user, activated by a diaphragm responsive to respiration. The diaphragm shall include an integrated exhalation valve. The mask-mounted regulator shall include a purge valve for an emergency bypass. The mask-mounted regulator shall be designed to direct the incoming air through a spray bar and over the inner surface of the facepiece lens for defogging purposes. The mask-mounted regulator shall incorporate a Heads-Up Display (HUD) to provide visual alerts to the SCBA user of air status and PASS alarm conditions. The mask-mounted regulator shall incorporate a latch mechanism to enable removal from the facepiece. The mask-mounted regulator shall require pulling back the thumb latch and a quarter (1/4) turn rotation to be removed from the facepiece.
5.0 Pressure Reducer with CGA Cylinder Connection The pressure reducer shall be mounted at the waist on the back frame and coupled to the cylinder valve through a short length of internally armored, high-pressure hose with a hand coupling for engagement and sealing within the cylinder valve outlet. Instead of a manual bypass, the pressure reducer shall include a backup pressure reducer connected with the primary pressure reducer and an automatic transfer valve for redundant control. The backup pressure reducer shall also activate the low-pressure alarm devices in the mask-mounted regulator. The low-pressure alarm warning shall denote a switch from the primary pressure reducer to the backup pressure reducer, whether due to a malfunction of the primary pressure reducer or low cylinder supply pressure. A press-to-test valve shall be included to allow functional testing of the backup pressure reducer. The pressure reducer should incorporate a resettable over-pressurization relief valve, which shall prevent the attached low-pressure hose and mask-mounted regulator from being subjected to high pressure.
6.0 End-of-Service Time Indicator (EOSTI) The SCBA shall have two end-of-service time indicators (EOSTI). The SCBA have two end-of-service time indicators (EOSTI): one that is both a tactile and audible alarm and one that is a Heads-Up Display (HUD). The primary EOSTI shall be the integral low-pressure alarm device that shall combine an audible alarm with simultaneous vibration of the facepiece. The primary EOSTI shall be in the positive pressure mask-mounted regulator. This alarm device shall indicate either low cylinder pressure (35% +/- 2%) or a malfunction of the primary pressure reducer. The HUD shall serve as the secondary EOSTI. The SCBA’s single power supply shall power the HUD. The HUD shall be mounted in the user’s field of vision on the positive pressure mask-mounted regulator. The HUD shall display cylinder pressure in increments of 100%, 75%, 50%, and 35% (+/- 2%). The display shall not have a numerical representation of cylinder pressure. At greater than three-quarters cylinder pressure, two green Light Emitting Diodes (LED) shall be illuminated. Between three-quarters and one-half cylinder pressure, one green LED shall be illuminated. Between one-half and 35% (+/- 2%) cylinder pressure, one “yellow” LED shall be illuminated and flash at a rate not less than one (1x) time per second. At 35% (+/- 2%) or less cylinder pressure, one “red” LED shall be illuminated and flash at a rate to exceed ten times (10x) per second. The HUD shall have a low battery indication that is distinct and distinguishable from the cylinder pressure indications.
7.0 Back frame and Harness Assembly The cylinder, valve, and pressure-reducing regulator assemblies shall be carried by a lightweight, lumbar support-style back frame and harness assembly. The back frame shall be a solid, one-piece black powder-coated aluminum alloy frame that is contoured to follow the shape of the user’s back. The back frame shall include a shroud to streamline hose and wire management by minimizing exposure to the low-pressure hose and electronics-molded cable. The back frame shall include an over-the-center, adjustable tri-slide fixture, a para-aramid strap, and a double-locking latch assembly to secure 30, 45, or 60-minute cylinders. The harness assembly shall include a waist pad and shoulder pads constructed of outer shell material and incorporating a closed-cell foam design to help minimize water and contaminant absorption. The harness assembly shall incorporate parachute-type, quick-release buckles with an integrated bail to help secure the webbing. The harness assembly shall have a one-size, black para-aramid strap with two red stripes along the outer edges and a reflective stripe in the center for enhanced visibility. The harness assembly shall include a seat-belt type waist belt attachment. The harness assembly shall include box-stitched construction with no screws or bolts. The harness assembly shall be removable from the back frame without using tools. The harness assembly shall be machine washable to help with contaminant exposure reduction. The harness assembly shall accommodate a waist belt extension. The waist pad shall be attached to the back frame so that the wearer's movement provides natural articulation. Articulation shall be accomplished without the use of mechanical devices. The waist pad and belt shall freely wrap around and conform to the user’s hips. The shoulder harness shall be fitted with a Drag Rescue Loop (DRL) capable of being deployed in an emergency to drag a downed wearer to safety. The DRL shall be sewn into the shoulder harness assembly, providing a horizontal pull strength of 1000 lbs. The DRL shall be stored in a manner that prevents accidental snags but maintains accessibility with gloved hands. The shoulder harness shall be attached to the back frame so that the harness presents itself for ease of donning. The shoulder harness shall include reflective material to enhance the user's visibility in low-light conditions. The shoulder harness shall accommodate two positions for a chest strap attachment. 8.0 Rapid Intervention Crew / Universal Air Connection (RIC/UAC) The SCBA shall incorporate a RIC/UAC fitting to comply with the NFPA 1981, 2018 Edition standard. The RIC/UAC shall be an integral part of the pressure reducer and protected by the back frame. The RIC/UAC inlet connection shall be within 4” (4 inches) of the cylinder valve. The self-resetting relief valve shall be color-coded to identify the pressure rating of the SCBA. The RIC/UAC shall have a check valve to prevent air loss when the high-pressure air source is disconnected.
8.0 Cylinder Type – Carbon-Wrapped The cylinder shall be manufactured in accordance with US Department of Transportation (DOT) specifications and meet the Transport Canada requirements with working pressures of 2216, 4500, or 5500 psig. The cylinder shall be a lightweight composite-type cylinder consisting of an aluminum alloy inner shell and a total overwrap of carbon fiber, fiberglass, and epoxy resin. The cylinder shall have a 2D barcode located under the protective gel coat programmed with the following information, at a minimum: serial number, manufacture date, and hydrostatic test date. The cylinder shall be available for 30, 45, 60, or 75 minutes, based on the NIOSH breathing rate of 40 liters per minute (ppm). The cylinder shall be available in a 30-year design as defined by the DOT Special Permit 14232.
9.0 Personal Alert Safety System (PASS) with Firefighter Locator The PASS Device shall be certified to NFPA 1982, Standard on Personal Alert Safety Systems, 2018 Edition. Operation of this distress alarm shall be initiated with the opening of the valve of a charged SCBA cylinder. The system shall feature a “hands-free” reset capability that may be activated by slight movement of the SCBA when it is in a pre-alarm mode. The system shall operate from a single power source containing six “AA” batteries. The system shall have a battery check function that provides an LED indication of battery status while the SCBA is not pressurized. When the PASS is manually activated, the locator system shall immediately emit a 2.4 GHz signal that can be received by a separate hand-held receiver. When the PASS is activated due to a lack of motion, the locator system shall have a ten-second delay before emitting a 2.4 GHz signal that can be received by a separate hand-held receiver. The locating system shall be programmable with eight alpha-numeric characters to provide identification information. The PASS device shall contain two components: a Console and a Sensor Module. When the PASS device goes into pre-alarm, the user shall be notified through a distinct light pattern in the HUD display located on the mask-mounted regulator.
9.1 Console The console shall be located on the user’s right shoulder harness. The control console shall come with a mechanical (analog) pressure gauge that is angled at 30°. The console shall contain an integral, edge-lit, mechanical pressure gauge that is automatically turned on by opening the cylinder valve. The console shall display to the user the following: Pre-Alarm: alternating red flashing LEDs; Full Alarm: dual flashing red LEDs and a flashing PASS icon; Low Battery: red flashing LEDs; Normal System Operation: flashing green LED.
The console shall contain a photo-sensing diode that automatically adjusts the brightness of the HUD as the ambient lighting conditions change. The console shall contain an integrated RFID tag. The console shall contain push buttons for the user interface. The push buttons shall be designed to minimize accidental activation. A yellow color-coded push button shall permit system reset. A red color-coded push button shall permit manual activation of the full alarm mode. The console shall be equipped with an LED “External HUD” that allows others to determine the user’s cylinder pressure using the same color-code scheme as the HUD display on the mask-mounted regulator. A green LED shall be illuminated across the gauge face to indicate a cylinder with greater than half-cylinder pressure. A yellow LED shall be illuminated across the gauge face to indicate a cylinder with less than half cylinder pressure. A red LED shall be illuminated across the gauge face to indicate a cylinder with less than 35% (+/- 2%) of the rated cylinder pressure.
9.2 Sensor Module The system shall include a sensor module mounted to the SCBA back frame and located between the cylinder and back frame in a manner designed to protect the assembly from damage. The sensor module shall contain a motion sensor sensitive to user hip movement to reduce false activations. The sensor module shall contain redundant, dual sound emitters for the audible alarm and dual visual “buddy” indicator lights. The sensor module sound emitters shall be oriented in multi-directions for optimal sound projection. The sensor module sound emitters shall broadcast a unique alarm tone for the following conditions: Pre-alarm PASS Full-alarm PASS Low battery
The visual indicators on the back frame-mounted sensor module shall flash green during normal operation. The visual indicators shall flash red when the device is in pre-alarm and full alarm. The visual indicators shall flash orange when the SCBA has reached one-half cylinder pressure. The visual indicators shall flash a combination of red, green, and white when the SCBA has reached 35% (+/- 2%) of the rated cylinder pressure. The sensor module shall have a Bluetooth® chipset integral to the unit to provide wireless connectivity to external devices.
10.0 Warranty The SCBA shall be covered by a warranty providing protection against defects in materials and workmanship. The warranty period shall be for as long as the SCBA is owned by the original purchaser. This warranty shall not require a registration to activate. This warranty shall not be contingent upon completing mandatory overhaul or recommended preventative maintenance.
11.0 Setup and Delivery Training The vendor will provide final setup, delivery, and acceptance testing at the Division of State Fire Marshal Office in Reynoldsburg, Ohio. A final checklist and sign-off will be completed between the vendor and the recipient. Following setup and testing, the vendor will provide a comprehensive day trainer session that covers the following:
12.0 Preventative Maintenance/Warranty The vendor will provide quotes and recommend price listings for preventative maintenance packages included in this bid, or the SFM can purchase them as part of the bid package for review. The vendor will provide the scope of all standard warranties and any extended warranties and pricing.
Find Active Opportunities Like This
Get AI-powered intelligence on the opportunities still open
Every page of the solicitation package shredded into a compliance breakdown
AI-powered matching based on your capabilities and past performance
Competitor and incumbent history on the requirement
Automated alerts on amendments, Q&A deadlines, and award
Join 750+ contractors already using CLEATUS