Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, November 11 at 2:00 PM ET

Register Free →

This Solicitation opportunity from Department Of Health And Human Services was posted on July 15, 2026. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

Olink Explorer >5400

Closed
75N98026Q00800Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

AI Contract Overview

Show more

The contract seeks a high-throughput proteomics platform capable of simultaneously measuring over 5,400 human proteins using Proximity Extension Assay technology with dual antibody recognition, DNA barcoding, and next-generation sequencing readout. It requires minimal sample input—just two microliters of plasma or serum—while delivering exceptional specificity at 99.5% due to the dual-antibody design and an expansive dynamic range spanning ten orders of magnitude, enabling detection of proteins from femtogram to milligram per milliliter concentrations. The platform must offer excellent sensitivity for low-abundance circulating proteins, particularly cytokines and signaling molecules, while maintaining broad proteome coverage with high reproducibility and standardization, making it suitable for large-scale epidemiological and multi-omics studies. The solicitation, issued by the National Institutes of Health under the Department of Health and Human Services, is cataloged under NAICS code 541380 and is titled Olink Explorer >5400. Responses are due by July 25, 2026, and the opportunity is open without any set-aside restrictions. The primary point of contact is John Burton at the NIH office in Bethesda, Maryland, with the procurement managed through the SAM.gov portal. The technology must meet rigorous performance benchmarks to support the lab’s research on inflammation, innate immunity, and the gut microbiome’s role in cancer development, progression, and therapeutic response.

General Info

High-throughput proteomics platform measuring 5,400+ human proteins from 2 µL plasma using Proximity Extension Assay.

NAICS

541380 - Testing Laboratories and Services

Place of Performance

Bethesda, MD, 20892, USA

Set-Aside

NONE

Documents

1

Requirement 7 - Protein Coverage and Technology Specifications

DOCX, High priority: read this firstrequirement
High

AI Contract Breakdown

Uniform Contract Format

Sign up to view the full breakdown with detailed analysis of each section.

Timeline

PhaseClosed
Posted

Solicitation

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Health And Human Services → National Institutes Of Health Olao
Contacts1 person available
OfficeBETHESDA, MD, 20892, USA
Office AddressBETHESDA, MD, 20892, USA
Contacts

Full Description

Show more

Requirements:


2.0       BACKGROUND 


Our lab studies the role of inflammation/innate resistance and commensal microbiota in carcinogenesis, cancer progression and therapy of cancer. 



The following product features/characteristics are required for this requirement:  


Protein Coverage - Measures ~5,400+ human proteins simultaneously in a single workflow. 


Technology - Uses Proximity Extension Assay (PEA) with dual antibody recognition coupled to DNA barcoding and next-generation sequencing (NGS) readout. 



Sample input – requires only 2 ul of plasma, serum, and other sample types 



Specificity - Reported 99.5% specificity with negligible cross-reactivity due to dual-recognition antibody design. 



Dynamic Range - Approximately 10 orders of magnitude (fg/mL to mg/mL), enabling detection of both low- and high-abundance proteins. 


Key strengths 


  • Very broad proteome coverage while maintaining antibody-based specificity.  

  • Excellent sensitivity for low-abundance circulating proteins (especially cytokines and signaling proteins).  

  • Extremely low sample-volume requirement.  

  • Highly standardized platform, making it attractive for epidemiology and multi-omics studies.

More opportunities from Department Of Health And Human Services → National Institutes Of Health Olao

Same awarding agency

Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS