Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, August 5 at 2:00 PM EDT

Register Free →

PARTS KIT,BALL VALV

Active
N0010426QNC96Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

AI Contract Overview

Show more

This contract pertains to the supply of a specialized parts kit for a 1 1/2 inch ball valve, designated as SPECIAL EMPHASIS Level I material due to its critical role in shipboard systems where failure could result in catastrophic consequences including loss of life or vessel. The kit includes a ball and two seats, each subject to rigorous material, dimensional, and performance specifications. The ball must be fabricated from SAE AMS-6931 or centrifugally cast 6AL-4V titanium with defined mechanical properties, while the seats must be made from Delrin with strict physical parameters including specific gravity, tensile strength, water absorption, and Teflon fiber content. Surface finish requirements are highly precise, mandating a final matte finish between RHR 12 and 16 after a specific polishing process using SUPFINA paste and a wool pad, followed by thorough cleaning. The ball's spherical surface must exhibit waviness no greater than 0.0005 inches per inch, and hydrostatic or dye penetrant testing is required for each ball with zero tolerance for leakage or deformation. The contract enforces stringent traceability, certification, and quality control protocols under ISO-9001, ISO-10012, and ISO/IEC 17025, or an approved alternative including MIL-I-45208 and MIL-STD-45662. Every component must be marked in accordance with MIL-STD-792 to ensure direct traceability from raw material to final product, with unique heat/lot/batch identifiers preserved through all manufacturing and subcontracting steps. Certifications must be positive, unqualified, and fully documented, with chemical and mechanical test reports tied directly to each marked piece. All testing, welding, and fabrication procedures must be pre-approved, with welding procedures and qualification data submitted for Navy review prior to processing. Special emphasis is placed on non-destructive testing, material handling, and prevention of commingling, with 100% inspection of traceability markings and certifications required prior to shipment. Submission of all documentation, including Certificates of Compliance and test results, must occur via the Wide Area WorkFlow system to Portsmouth Naval Shipyard for review and acceptance before any shipment, with electronic submission through ECDS required for waivers, deviations, and engineering change proposals. The requirement is issued under Emergency Acquisition Flexibilities and is subject to DPAS priority rating, with full compliance mandatory under Buy American and small business program regulations.

General Info

Supplies critical 1.5-inch ball valve kit with titanium ball and Delrin seats, stringent quality, traceability, and Navy-approved testing required.

Agency

Department Of Defense → Navsup Weapon Systems Support MechView Agency

NAICS

332919 - Other Metal Valve and Pipe Fitting ManufacturingView NAICS

Place of Performance

PA

Set-Aside

NONE

Documents

(0)

No documents available

AI Contract Breakdown

Uniform Contract Format

No contract breakdown available.

Cannot generate Contract Breakdown because no documents were found from this contract's source.

Timeline

PhaseSolicitation
Posted

Solicitation

Response Deadline

Submission deadline

Response Deadline

Ready to pursue this opportunity?

Start your free trial to track this contract, build proposals with AI assistance, and manage your pipeline.

Organization & Contact Information

Show more
AgencyDepartment Of Defense → Navsup Weapon Systems Support Mech
Contacts1 person available
OfficeMECHANICSBURG, PA, 17050-0788, USA
Organization / Agency
Department Of Defense → Navsup Weapon Systems Support Mech
View Agency Profile
Office AddressMECHANICSBURG, PA, 17050-0788, USA

Full Description

Show more
CONTACT INFORMATION|4|N744.24|WVN|771-229-0476|HEATHER.R.JONES52.CIV@US.NAVY.MIL| ITEM UNIQUE IDENTIFICATION AND VALUATION (JAN 2023)|19|||||||||||||||||||| HIGHER-LEVEL CONTRACT QUALITY REQUIREMENT (DEC 2014)|1|See Specifications Section C and Section E.| INSPECTION OF SUPPLIES--FIXED-PRICE (AUG 1996)|2||| GENERAL INFORMATION-FOB-DESTINATION|1|A| WIDE AREA WORKFLOW PAYMENT INSTRUCTIONS (JAN 2023)|16|Stand-Alone Receiving Report - Certifications; COMBO - Receiving Report & Invoice - Material|N/A|TBD|N00104|TBD|TBD|SEE SCHEDULE|TBD|||TBD||||See form DD1423|| NAVY USE OF ABILITYONE SUPPORT CONTRACTOR - RELEASE OF OFFEROR INFORMATION (3-18))|1|WSS| MANDATORY USE OF WORKFLOW PRO (WFP) MOD ASSIST MODULE|1|| WARRANTY OF SUPPLIES OF A NONCOMPLEX NATURE (JUNE 2003)|6|TBD|TBD||||| BUY AMERICAN-FREE TRADE AGREEMENTS-BALANCE OF PAYMENTS PROGRAM-BASIC (FEB 2024)|11|||||||||||| SMALL BUSINESS SUBCONTRACTING PLAN (DOD CONTRACTS)-BASIC (DEV 2026-O0037)(FEB 2026))|2||| WARRANTY OF DATA-BASIC (DEVIATION 2026-O0035) (FEB 2026)|2||| NOTICE OF TOTAL SMALL BUSINESS SET-ASIDE (DEV 2026-O0037)(FEB 2026)|1|| SECURITY PROHIBITIONS AND EXCLUSIONS (CLASS DEVIATION 2026-O0025)(FEB 2026)|7|||||||| SMALL BUSINESS PROGRAM REPRESENTATIONS (DEV 2026-O0037)(FEB 2026)|20||||||||||||||||||||| BUY AMERICAN-FREE TRADE AGREEMENTS-BALANCE OF PAYMENTS PROGRAM CERTIFICATE-BASIC (FEB 2024))|5|||||| BUY AMERICAN-BALANCE OF PAYMENTS PROGRAM CERTIFICATE-BASIC (FEB 2024)|1|| ALTERNATE A, ANNUAL REPRESENTATIONS AND CERTIFICATIONS (DEVIATION 2026-O0043)(FEB 2026))|13|||||||||||||| NOTICE OF PRIORITY RATING FOR NATIONAL DEFENSE, EMERGENCY PERPARDENESS, AND ENRGY PROGAM USE (APRIL 2008))|2||X| 1. This requirement is pursuant to Emergency Acquisition Flexibilities (EAF). 2. The resultant award of this solicitation will be issued bilaterally, requiring the contractor's written acceptance prior to execution. 3. All contractual documents (i.e. contracts, purchase orders, task orders, delivery orders, and modifications) related to the instant procurement are considered to be "issued" by the Government when copies are either deposited in the mail, transmitted by facsimile, or sent by other electronic commerce methods such as email. The Government's acceptance of the contractor's proposal constitutes bilateral agreement to "issue" contractual documents as detailed herein. 4. If requirement will be packaged at a location different from the offeror's address, the offeror shall provide the name, street address, and CAGE of the facility. 5. Any contract awarded as a result of this solicitation will be DO certified for national defense under the Defense Priorities and Allocations System (DPAS). Provision 52.211-14, Notice of Priority Rating for National Defense, Emergency Preparedness, and Energy Program Use, shall be inserted in solicitations when the contract to be awarded shall be a rated order. 6. If drawings are included in the solicitation, access needs to be requested on the individual solicitation page under Contract Opportunities on SAM.gov website. After requesting access, send an email to the POC listed on the solicitation. 7. NAVSUP WSS Mechanicsburg will be considering past performance in the evaluation of offers IAW FAR 13.106(a)(2). 8. Data Item A001 (Inspection and Test Plan) may be waived if already on file at NAVSUP WSS Mechanicsburg. \ 1. SCOPE 1.1 The material covered in this contract/purchase order will be used in a crucial shipboard system. The use of incorrect or defective material would create a high probability of failure resulting in serious personnel injury, loss of life, loss of vital shipboard systems, or loss of the ship itself. Therefore, the material has been designated as SPECIAL EMPHASIS material (Level I, Scope of Certification, or Quality Assured) and special control procedures are invoked to ensure receipt of correct material. 2. APPLICABLE DOCUMENTS 2.1 Order of Precedence - In the event of a conflict between the text of this contract/purchase order and the references and/or drawings cited herein, the text of this contract/purchase order must take precedence. Nothing in this contract/purchase order, however, must supersede applicable laws and regulations unless a specific exemption has been obtained. 2.2 Applicable Documents - The document(s) listed below form a part of this contract/purchase order including modifications or exclusions. 2.2.1 Specification Revisions - The specification revisions listed under "Documents References" below are the preferred revision. Older and/or newer r evisions are acceptable when listed within Contract Support Library Reference Number CSD155 in ECDS (Electric Contractor Data Submission) at: ht tps://register.nslc.navy.mil/. This is to allow Contractors to use certain acceptable older specification revisions to purge their existing stock of material certified to those older revisions or to use newer specification revisions when material is certified to newly released revisions,without requiring the submittal of waiver/deviation requests for each specification revision on every contract. Revisions of specifications reflecting editorial and/or re-approval (e.g. E2009, R2014, etc.) are considered inconsequential, but are acceptable when their revisions are listedwithin CSD155 or elsewhere within this contract. 2.2.2 "Document References" listed below must be obtained by the Contractor. Ordering information is included as an attachment to this contract/purchase order. 2.2.3 Documents, drawings, and publications supplied are listed under "Drawing Number". These items should be retained until an award is made. DRAWING DATA=255582 |43689| M| |D| | | | DRAWING DATA=255584 |43689| J| |D| | | | DOCUMENT REF DATA=ANSI/ASQ Z1.4 | | | |080101|A| | | DOCUMENT REF DATA=ASTM-B367 | | | |220401|A| | | DOCUMENT REF DATA=MIL-STD-792 | | |F |230223|A| |01| DOCUMENT REF DATA=MIL-STD-2035 | | |A |950515|A| | | DOCUMENT REF DATA=SAE AMS 6931 | | |D |171201|A| | | DOCUMENT REF DATA=ISO_9001 | | | |081115|A| | | DOCUMENT REF DATA=MIL-PRF-9954 | | |D |090416|A| | | DOCUMENT REF DATA=ISO10012 | | | |030415|A| | | DOCUMENT REF DATA=ISO/IEC 17025 | | | |050515|A| | | DOCUMENT REF DATA=MIL-I-45208 | | |A |810724|A|1 | | DOCUMENT REF DATA=MIL-STD-45662 | | |A |880801|A| | | DOCUMENT REF DATA=ANSI/NCSL Z540.3 | | | |130326|A| | | DOCUMENT REF DATA=0900-LP-001-7000 | | | |810101|A| |01| DOCUMENT REF DATA=S9074-AQ-GIB-010/248 | | |1 |191112|A| | | DOCUMENT REF DATA=T9074-AS-GIB-010/271 | | |1 |140911|A| | | DOCUMENT REF DATA=S9074-AR-GIB-010A/278 (CHG A) | | | |130214|A| | | 3. REQUIREMENTS 3.1 ;Parts Kit for a size 1 1/2 inch Ball Valve, consisting of one Ball, Piece 59, on Newport News Shipbuilding Drawing 255582 and two matching Seats, Piece 19, on Newport News Shipbuilding Drawing 255584, except as amplified or modified herein.; 3.2 Material for Parts Requiring Certification - Quantitative chemical and mechanical analysis is required for the parts listed below unless specifically stated otherwise: Part - ;Ball, Piece 59; Material - SAE-AMS-6931 OR Centrifugally cast 6AL-4V, ASTM-B367, Grade C-5, with mechanical properties as listed in supplementary Requirement S6. Note: Mechanical properties for bars, forgings and forging stock over 10" must be as specified in the applicable drawing. If the mechanical properties are not provided in the drawing, the mechanical properties specified in SAE-AMS-6931 Table 2 for material 6" to 10", must be applied. Part - ;Seats (Q3), Piece 19; Material - Delrin: Dupont AF DE588 (Teflon Filled Acetal) (Properties Specified Below Only) ITEM PROPERTY ASTM TEST METHOD VALUE (A) Specific Gravity D792 (Note 1) 1.50 - 1.57 (B) Melting Point D2133 or D3418 172 - 184 deg C (342 - 363 deg F) (C) Tensile Strength (MIN) D638 (Notes 1 & 5) 6100 PSI (D) Tensile Impact (MIN) D1822 Type S (Notes 1 & 5) 5 FT-LB/SQ IN (E) Compressive Stress D695 2100 @ 1% DEF. (MIN - PSI) (Notes 1 & 5) 11,000 @ 10% DEF. (F) Water Absorption D570 .30% MAX 24 Hours (G) Rockwell Hardness (R) D785 (Note 1) 115 +/- 15 (H) Teflon Fiber Content (Note 2) 18 - 23% (I) Dimensional Change (Note 4) .7% MAX NOTES: 1. Material conditioning prior to test is at the vendor's option. 2. Teflon Fiber Content - As certified by DuPont (raw material). 3. Visual and Dimensional Inspection of Product (Final Machined Condition) - White Teflon string inclusions must not exceed the following: A. Diameter 1/32" B. Length 1/8" C. Density 6 indications per 100 SQ IN 4. The test method to determine dimensional stability must be performed as follows: The test specimens (finished pieces) tested must be measured at 23 +/- 3 deg C (73 +/- 5F) and placed in a mineral oil bath maintained at 160 +/- 3 deg C (320 +/- 5F) the specimens must remain in the bath for six (6) hours at temperature and allowed to slow cool in the bath at a rate not to exceed 23 +/- 3 deg C (73 +/- 5F) per hour. When the bath reaches 23 +/- 3 deg C (73 +/- 5F), the test specimens must be removed and measured. The percent change in each dimension, outside diameter, inside diameter and thickness must not be greater than the value specified. ^Mineral oil meets the specification as listed below: Description.......................Passes U.S.P. Test (USP XX, P.1143) Solubility........................Passes U.S.P. Test (USP XX, P.1143) Neutrality........................Passes U.S.P. Test (USP XX, P.532) Readily Carbonizable Substances...Passes U.S.P. Test (USP XX, P.532) Limit of Polynuclear Compounds....Passes U.S.P. Test (USP XX, P.532) Solid Paraffin....................Passes U.S.P. Test (USP XX, P.532) Specific Gravity @ 25 deg C (77 deg F).0.8600 to 0.8900 Viscosity @ 37.8 deg C (100F).....73.6 to 84.4 Centistokes (340-390 SUS) Flash Point Cleveland Open Cup....420 deg F (216C) (Typical) Refractive Index @ 20C (68F)......1.480 (Typical) 5. Values are minimum mean values. Individual specimen values may not vary more than 25% below the specified minimum mean value. Should one specimen exceed the 25% criteria, retest is required. Failure to meet the above criteria a second time is cause for rejection. 3.3 Testing Certification - Certifications are required for the following tests on the items listed below. Additional testing on other piece parts (if any) per applicable drawings and specifications is still required, but certifications are only required as listed below. Test - Hydrostatic Test Item - Each Ball Performance - 30 minutes at ;1050 PSI; with stem hole plugged Acceptance - No weeping, leakage, or permanent deformation. The following may be substituted by manufacturers who do not posess a hydrostatic test fixture: Test - Dye Penetrant Inspection Item - Each Ball Performance - T9074-AS-GIB-010/271 Acceptance - S9074-AR-GIB-010A/278 (Castings) / MIL-STD-2035 (Wrought) Test - Non-Destructive Tests Item - ;Weld Repair and/or Production Weld (as applicable); Performance - Per applicable fabrication specification Acceptance - Per applicable fabrication specification 3.4 Seat Stack Height Measurement - To ensure that each seat is within tolerance, check each seat individually by measuring the seat height with the ball resting on the seat. Limits are determined by the ball diameter tolerance and the stack height tolerance combined. Refer to CSD171 for recommended methods to measure and calculate stack heights. CSD171 is available in the ECDS (Electronic Contractor Data Submission) system at: https://register.nslc.navy.mil/. 3.5 A visual inspection shall be performed on the finished seat with acceptance criteria on critical surfaces per CSD167 in the ECDS (Electronic Contractor Data Submission) system at: https://register.nslc.navy.mil/. 3.6 Ball Spherical Surface Finish - Spherical surfaces of valve balls must be finished as follows: Machine finish spherical surfaces of the valve ball to between 30 and 35 RHR; use lubricant. Grind, hone, or cup polish to 16 RHR maximum; use lubricant (light oil or soap solution). Grit blast with glass bead media (MIL-PRF-9954-MIL 10); use a 3/16 inch ID blasting nozzle (not supersonic type) 4 inches from ball at 75 PSI air pressure. The resulting surface finish should be less than 25 RHR.Perform final polish with SUPFINA Polishing Paste (Pink polishing paste, item code 10100244, Supfina Machine Company, North Kingstown, RI). Apply the SUPFINAPolishing Paste that is initially light pink in color over the entire surface of the ball with a brush and perform a low speed finishing process with both theball and a .250" thick wool pad (Style 22110, Aetna Felt Corporation, Allentown, PA^) turning at the same time with light pressure for approximately 30 seconds^^ (3 revolutions) of the entire surface of the ball. Once the light pink SUPFINA polishing paste that was applied to the surface of the ball turns a grey color, the final finishing process is complete. After the final finishingprocess is complete, the surface of the ball should have a matte dull appearance with a surface finish between RHR 12 and RHR 16. Clean ball with a warm, alkaline solution or a liquid nonionic detergent to remove SUPFINA polishing paste. ^ Reference customer number PLI00499 when ordering wool pad. ^^ CAUTION: Excessive time will cause the ball to be polished in violation of the process." 3.7 Ball Spherical Surface Waviness - Unless otherwise specified on drawing, all sealing area surfaces must have a spherical surface waviness which does not exceed 0.0005 inches of height per inch of spherical surface. Roughness and waviness ratings must apply in a direction which yields the maximum rating, normally perpendicular to the lay. 3.8 Welding or Brazing - When welding, brazing, and allied processes are required, as invoked by Section C paragraph 3 requirements, they must be in accordance with S9074-AR-GIB-010A/278, 0900-LP-001-7000 for brazing of piping and pressure vessel applications, or S9074-AQ-GIB-010/248 for brazing of other applications. For all production and repair welding and brazing personnel and procedures must be qualified under S9074-AQ-GIB-010/248 or 0900-LP-001-7000, as applicable. Procedures and Qualification Data must be submitted for review and approval prior to performing any welding or brazing. 3.9 Certificate of Compliance - (SPECIAL EMPHASIS MATERIAL) The Contractor must prepare and submit a certificate of compliance certifying that the items/components furnished under this contract comply with the requirements of the procurement document, including any/all invoked specifications and drawings. 3.10 Configuration Control - The Contractor must maintain the total equipment baseline configuration. For items of proprietary design, Contractor drawings showing the latest assembly configuration must be provided to the Government in electronic (C4) format. Definitions are provided elsewhere in the Contract/Purchase Order. 3.10.1 Waivers/Deviations - All waivers and deviations, regardless of significance or classification require review and approval by the Contracting Officer. Waivers and Deviations must be designated as Critical, Major, or Minor. The Contractor must provide a copy of this request to the QAR. Requests must include the information listed below. a. A complete description of the contract requirement affected and the nature of the waiver/deviation (non-conformance), including a classification of Critical, Major, or Minor. b. Number of units (and serial/lot numbers) to be delivered in this configuration. c. Any impacts to logistics support elements (such as software, manuals, spares, tools, and similar) being utilized by Government personnel or impacts to the operational use of the product. d. Information about remedial action being taken to prevent reoccurrence of the non-conformance. 3.10.2 All requests for Waivers/Deviations on NAVSUP-WSS Contracts must be submitted to the NAVSUP WSS Contracting Specialist via eMail. 3.10.3 ECPs - The Government will maintain configuration control and change authority for all modifications or changes affecting form, fit, function, or interface parameters of the Equipment and its sub-assemblies. The Contractor must submit an Engineering Change Proposal (ECP) for any Class I or II changes that impact the Equipment covered by this contract. ECPs must be prepared in Contractor format, and must include the following information: a. The change priority, change classification (Class I or Class II), and change justification. b. A complete description of the change to be made and the need for that change. c. A complete listing of other Configuration Items impacted by the proposed change and a description of the impact on those CIs. d. Proposed changes to documents controlled by the Government. e. Proposed serial/lot number effectivities of units to be produced in, or retrofitted to, the proposed configuration. f. Recommendations about the way a retrofit should be accomplished. g. Impacts to any logistics support elements (such as software, manuals, spares, tools, and similar) being utilized by Government personnel in support of the product. h. Impacts to the operational use of the product. i. Complete estimated life-cycle cost impact of the proposed change. j. Milestones relating to the processing and implementation of the engineering change. 3.11 Mercury Free - Mercury and mercury containing compounds must not be intentionally added or come in direct contact with hardware or supplies furnished under this contract. Mercury contamination of the material will be cause for rejection. 3.12 NAVSEA 0948-LP-045-7010 - Any applicable requirements of NAVSHIPS 4410.17,NAVSEA 0948-LP-045-7010, or 0948-045-7010 which the contractor must meet are included in this contract/purchase order. The above documents are for GovernmentUse Only. Further application of the above documents is prohibited.prohibited. 3.12.1 Marking of material with a Material Designator per the Drawing is also prohibited, with the exception of Fasteners. Fasteners must be marked with a Material Symbol/Designator as specified elsewhere in this contract. ^ QUALITY ASSURANCE REQUIREMENTS ^ 3.13 See CDRL DI-MISC-80678 (Test Certification) - A statement of tests performed, listing the pieces tested must be furnished along with a copy of the test results. Certification must include the contractor's name, address and date, quantity inspected, identified to the contract/purchase order and item number, and the Contractor's or authorized personnel's signature. Test certifications must reference the standard/specification, including the revision, to which the testing was performed and the acceptance criteria used. Test procedure numbers may also be referenced on test reports. Test reports on weldments must be identified to weld joint and layer. 3.14 Welding Requirements - When production or repair welding is required, the applicable welding procedure(s) and qualification data must be submitted for review and approval. In addition, the CONSUMED WELD METAL C of C as defined below must be submitted as part of the certification OQE package submitted by the Contractor. Note: These requirements do not apply to tack/spot welds when the conditions of Section 4.2.1.1 of S9074-AR-GIB-010A/278 are met. 3.14.1 Approval of the Contractor's qualification data must be obtained prior to performing any welding (production or repair). 3.14.2 If the Contractors qualification data has previously been approved by the Navy for other contracts, a copy of the original approval letter may be submitted along with the procedures and qualification data report to expedite the approval process. The approval letter must reference the applicable welding procedure and qualification data report identification/number. Prior approval does not guarantee acceptance for this or any future contracts. As far as practical, all procedures for the contract must be submitted at the same time. Welding procedures and qualification data must be submitted in a commercially available electronic format such as Adobe Acrobat PDF. The contractor must state the applicability of each weld procedure and qualification data submitted, citing the drawing number and pieces to be welded. (i.e. ''WP-123 and QD-123 are submitted for the weld joint between pieces 1 and 2 on drawing ABC'.' WP-456 and QD-456 are submitted for the hardfacing of piece 3 on drawing XYZ'') 3.14.3 The PCO's authorization for the use of weld procedure(s) and qualification data for the specific application as submitted does not mitigate the vendors responsibility to comply with the requirements of S9074-AQ-GIB-010/248, S9074-AR-GIB-010A/278, and the contract. 3.14.4 Authority for the repair of Special Repairs in castings, the repair of wrought material, or the repair of forged material must be obtained via request for waiver from the Procurement Contracting Officer. This request must describe the defect; including size, depth, location, and a description of the proposed repair. Repairs deemed minor or nominal in accordance with S9074-AR-GIB-010/278 can be made at contractor discretion in accordance with S9074-AR-GIB-010/278 requirements; however, Weld Procedure Specification (WPS) and Procedure Qualification Record (PQR) submittals are still required. This request for NAVSUP-WSS Contracts must be submitted via the Electronic Contractor Data Submission (ECDS) application. 3.14.5 Any new procedure qualification performed under this Contract will require the vendor to provide a minimum 72 hour notification to DCMA with an offer to observe the welding of the test assemblies. The 72 hour time limit may be modified upon mutual agreement between the vendor and DCMA. 3.14.6 When drawings require hardfacing surface Iron or Nickel content not to exceed 5%, the contractor must verify surface Iron or Nickel content by performing chemical testing as defined by the applicable drawing. The chemical test results must be submitted as part of the qualification data. 3.14.7 Additional qualification requirements for production hardfacing thickness less than 1/8-inch: Macro-etch (or legible photomacrographs clearly showing the fusion area) must be submitted for review and show consistent, minimized dilution. All essential elements and any elements not listed in S9074-AQ-GIB-010/248 that influence dilution must be in the qualification data and weld procedure, with strict limits placed on each essential element. 3.14.8 Preparation and retention of weld records is required, as specified by paragraph 4.1.3 of S9074-AR-GIB-010A/278. 3.14.9 When production or repair welding is required on titanium materials, the applicable fabrication plan, facilities procedure, training plan, and active welder qualification must also be submitted for review and approval. 3.14.10 If the contractor's fabrication plan, facilities procedure, training plan, or active welder qualification has previously been approved by the Navy for other contracts, a copy of the original approval letter may be submitted along with the applicable documentation to expedite the approval process. The approval letter must reference the applicable documentation. Prior approval does not guarantee acceptance for this or any future contracts. The contractor's fabrication plan, facilities procedure, training plan, and active welder qualification must be submitted at the same time as the applicable welding procedure(s) and weld procedure qualification data. All documentation must be submitted in a commercially available electronic format, such as Adobe Acrobat PDF. 3.14.11 A Certificate of Compliance is required for all weld filler metals used for production or repair welding, and must include the following: a) Filler Metal LOT number(s) b) Specification and Type c) A positive statement that the vendor has obtained OQE and verified thateach LOT of weld filler material conforms to specification requirements. d) A positive statement verifying that the weld filler metals were the correct material type or grade prior to consumption. 3.14.12 When production welds or repair welds are performed by a subcontractor,the requirement for submission of all certification documentation required herein must be passed down to the subcontractor. 3.15 Quality System Requirements - The Contractor furnishing items under this contract/purchase order must provide and maintain a quality system in accordance with ISO-9001 as amplified or modified herein, with the calibration system requirements of ISO-10012 or ANSI-Z540.3 with ISO-17025. A Quality System in accordance with MIL-I-45208, with the calibration system requirements of MIL-STD-45662, is acceptable as an alternate. 3.15.1 The Contractor's quality system and products supplied under the system are subject to evaluation, verification inspection, and acceptance/non-acceptance by the Government representative to determine the system's effectiveness in meeting the quality requirements established in the Contract/Purchase Order. 3.15.2 The Contractor's quality system must be documented and must be available for review by the Contracting Officer or his representative prior to initiation of production and throughout the life of the contract. The Prime Contractor must, upon notification, make his facilities available for audit by the contracting Officer or his authorized representative. 3.15.3 See CDRL DI-QCIC-81110 (Inspection System Procedures) - All suppliers of Level I/SUBSAFE (LI/SS) material are required to submit a copy of their current documented quality system procedures to the Procurement Contracting Officer (PCO) prior to award of any contract/purchase order. Suppliers that have a copy of their current quality system procedures on file at the Procuring Activity may request the PCO waive this requirement. 3.15.4 This contract provides for the performance of Government Quality Assurance at source. The place or places of performance may not be changed without the authorization of the Procurement Contracting Officer. Upon receipt of this order, promptly notify the Government representative who normally services your plant so that appropriate planning for Government inspection can be accomplished. If you do not have an assigned Government representative, notify the nearest Defense Contract Management Agency (DCMA) Office. In the event that a local Government representative or DCMA Office cannot be located, our purchasing agent should be notified immediately. 3.15.5 Any changes made by the Contractor to a qualified quality system will require re-submittal to the PCO and concurrence by the Government Quality Assurance Representative prior to adoption. 3.16 Contractor Inspection Requirements - The Contractor must maintain adequate records of all inspections and tests. The records must indicate the nature and number of observations made, the number and type of deficiencies found, the quantities approved and rejected and the nature of corrective action taken as appropriate. Inspection records must be traceable to the material inspected. 3.16.1 The supplier's gages, measuring and test equipment must be made available for use by the Government representative when required to determine conformance with Contract requirements. When conditions warrant, the supplier's personnel must be made available for operations of such devices and for verification of their accuracy and condition. 3.16.2 All documents and reference data applicable to this contract must be available for review by the Government representative. Copies of documents required for Government inspection purposes must be furnished in accordance with the instructions provided by the Government representative. 3.17 Subcontractor Inspection Requirements - The Government has the right to inspect at source, any supplies or services that were not manufactured or performed within the contractor's facility. Such inspection can only be requested by or under authorization of the Government representative. Any purchasing documents to a subcontractor must cite the applicable portions of the contractually invoked quality system (e.g. calibration requirements), plus any product requirements that apply to the supplies being purchased. When the Government elects to perform source inspection at the subcontractor's facility, applicable purchase documents must be annotated with the following statement: "A Government inspection is required prior to shipment from your plant. Upon receipt of this order, promptly notify the Government representative who normally services your plant so that appropriate planning for Government inspection can be accomplished. If you do not have an assigned Government representative, notify the nearest Defense Contract Management Agency (DCMA) Office. In the event that a local Government representative or DCMA Office cannot be located, our purchasing agent should be notified immediately." 3.18 The prime contractor's program must include procedures to assess the capability of the prospective suppliers to produce the products or supply the services in accordance with the contract, prior to the issuance of any purchase document. 3.18.1 Each sub-tier supplier of material or services for items in Section 3 of this contract must be subjected to a periodic review or audit by the Prime to determine the continued capability of the supplier to control the quality of the products or services specified in the purchase order or contract. 3.18.2 The prime contractor must ensure that the purchased product conforms to specified purchase requirements and this contract. The type and extent of control applied to the supplier and the purchased product must be dependent upon the effect of the purchased product on the end item represented by this contract. 3.18.3 The prime contractor must evaluate the requirements of the contract and select suppliers based on their ability to supply the product in accordance with the prime contractor's requirements and the contract. Criteria for selection and evaluation must be established. Records of this effort must be available for review by the government. 3.18.4 The prime contractor's supplier quality assurance program must provide for a review of purchase documents to assure applicable quality requirements are included or referenced in the documentation for compliance by the supplier. 3.19 Government Furnished Material and/or Equipment (GFM/GFE) - When material or equipment is furnished by the Government, the Contractor must develop documented control procedures that require at least the following: 3.19.1 Visual examination upon receipt to detect damage during transit. 3.19.2 Inspection for completeness and proper type. 3.19.3 Verification of material quality received. 3.19.4 Periodic inspection and precautions to assure adequate storage conditions and to guard against damage from handling and deterioration during storage. 3.19.5 Functional testing, either prior to or after installation, or both, as required by the Contract to determine satisfactory operation. 3.19.6 Identification and protection from improper use or disposition. 3.19.7 Reporting to the Government, any GFM or GFE property found damaged, malfunctioning, or otherwise unsuitable for use. In the event of damage or malfunction during or after installation, the supplier must determine and record probable cause and necessity for withholding the material from use. 3.19.8 For GFE material, and as required by the terms of the bailment agreement, the supplier must establish procedures for adequate storage, maintenance, and inspection of bailed Government material. Records of all inspection and maintenance performed on bailed property must be maintained. 3.19.9 Material returned to the contractor must be handled as GFM. 3.20 Traceability and Certification Requirements - To assure that correct materials are installed in Level I/SUBSAFE systems, it is imperative that traceability be maintained from the material to the material certification test report and other required Objective Quality Evidence (OQE). The material certification report must completely and accurately reflect that the material supplied meets the specified requirements. Materials requiring Traceability and Certification Data are identified within Paragraph 3, Section C of this contract/purchase order. 3.20.1 The following provides the minimum requirements for maintaining material traceability and supplements the requirements specified in DI-MISC-81020 and elsewhere in the contract/purchase order. The Contractor must develop written procedures that implement the material control requirements stated herein. 3.21 Material Traceability - The certification data report must be identified through a unique traceability number, heat-lot number, or heat-treat number for metallic material or batch of non-metallic material, as applicable, which must also be marked on the material. This traceability marking on the material must provide direct traceability to the material's chemical composition and mechanical properties certification data. For material produced by batch, continuous cast, or continuous pour processes, samples must be taken no less than once in every eight hours of operation for the purpose of validating proper chemical composition and mechanical properties. Traceability must be maintained through all process operations including any subcontracted operations, to the finished component. 3.21.1 Material Marking for Traceability and Identification - The following are the minimum marking requirements. Additional/alternate marking requirements, if applicable, will be specified elsewhere in the contract/purchase order. In addition to the marking requirements on applicable drawings and/or specifications, marking for traceability is required. All traceability markings must be permanently applied in accordance with MIL-STD-792 (except as specified below). An alternate marking method is permissible provided it is an available option in the contractually invoked specification or drawing, except in instances where the material has been modified by this contract/purchase order and differs from that specified in the specification or drawing. 3.21.2 Traceability markings for items with precision machined or plated surfaces, or material with suitable marking surface areas less than 3/8 inches square (either 3/8" x 3/8" or an area equal to 0.1406 inches square) must be applied to a durable tag and the tag securely affixed to the material. 3.21.3 Permanent marking must be legible and must be located so as to not affect the form, fit, and function of the material. ;Ball must be marked in the waterway and Seats to be marked on the outer cylindrical surface.; 3.21.4 Seat Marking - Each seat must be permanently marked in accordance with MIL-STD-792, type I and as stated below, except for Teflon seats, which must only be tagged. Type IX marking may be substituted for type I, provided the minimum character size scribed by the marking tool must be approximately 3/32 inch high to insure legibility. Permanent marking is not permitted on Teflon seats. Seat marking requirements must maintain complete traceability to certification OQE. Seat marking must be either heat/lot or batch number, a vendor traceability number/code, or a combination thereof and must be unique to the material certification. 3.21.5 Traceability markings must be maintained through assembly, and whenever possible must be visible after assembly. For items where the marking is not visible after assembly, a durable tag must be securely attached to the item identifying the part number, piece number, traceability number, and the location of the permanent mark. 3.22 See CDRL-DI-MISC-81020 (Chemical and Mechanical) and CDRL DI-MISC-80678 (SEAT MATERIAL) - Material Certifications - The following material certification requirements apply: 3.22.1 Metallic Material - Quantitative chemical and mechanical analysis of material traceable to traceability markings is required. Material certification test reports must include the class, form, condition, grade, type, finish, and/or composition, as applicable, of the material supplied. 3.22.2 Non-Metallic Material - The Contractor must furnish the applicable test reports for each heat/lot/batch of seat material. Material certification test reports must include, in addition to the specification, the class, form, grade, type, process, and/or composition, as applicable, of the material supplied. 3.22.3 Re-identification and re-certification of metallic material is required when the material is subjected to a process which alters its properties. If the starting material or raw stock is processed in a manner that will not affect its chemical composition or mechanical properties, the original certifications for the chemical composition and mechanical properties, as required by the material specification, are acceptable. Re-certification of the chemical or mechanical properties is required if a process is used during fabrication that alters the original properties of the material (e.g. alloying, heat treating, or forming). In these instances, the properties of the material must be re-determined and documented to reflect the altered condition. The altered material must be uniquely re-identified. The properties thus determined and documented, are required for final certification and must conform to the material specification or the contract/purchase order requirements. When only the mechanical properties are altered, the original certification forchemical composition must be overstamped and annotated with the unique traceability marking used with the altered material and at a minimum contain the information below. TRACEABILITY MARKING________________________________________________ (marking on finished item) IS FABRICATED FROM RAW MATERIAL IDENTIFIED TO HEAT/LOT NUMBER _______________ AND HEAT TREAT NUMBER ______________________ (when applicable) _________________________________________ DATE _____________________ (name and signature of auth. co. rep.) 3.22.4 Material certification data forwarded by the manufacturer must contain a signed certification that the report results represent the actual attributes of the material furnished and indicate full compliance with all applicable specification and contract requirements. Transcription of certification data is prohibited. 3.22.5 Statements on material certification documents must be positive and unqualified. Disclaimers such as "to the best of our knowledge" or "we believe the information contained herein is true" are not acceptable. 3.22.6 If material is received without the required certification papers or with incorrect/missing data on the certification papers, the material will be rejected. 3.23 Material Handling - The written material control process must include the following: 3.23.1 All raw materials must have traceability markings (except as specified below). 3.23.2 Stored raw materials requiring traceability must be segregated to preclude intermingling with materials not requiring traceability. 3.23.3 When traceability markings will be removed by a manufacturing or fabrication process, the marking must be recorded prior to removal and be immediately restored upon completion of the process. If this cannot be done or is impractical, an appropriate material control procedure (such as a bag and tag, tagging, and/or tote box control) must be employed. The material control procedure must provide a method of positive control to preclude commingling of heats/lots or loss of traceability. The traceability marking must be reapplied upon completion of the final manufacturing process. 3.23.4 Brazing or weld filler metals for strength welds forming or integral with pressure containing components or assemblies requiring traceability must be verified to be the correct material, and type or grade, as applicable, prior to consumption. At a minimum, material verification must consist of inspection of material test reports for conformance to specified requirements. Control of welding and brazing filler metals must be maintained to the point of consumption to assure use of the correct type and grade. Markings and traceability requirements do not apply to brazing and weld filler metals after consumption. It is the responsibility of the prime contractor to ensure conformance with the above requirements on welds performed by their subcontractors. 3.23.5 Purchase orders for raw material must specify that the material be traceable to material certification test reports by traceability markings on the material and identified on the test reports. The certification data requirements contained in DI-MISC-81020 must be invoked by the prime contractor on all subcontractors supplying Level I material. 3.23.6 The material control process must include requirements for the maintenance of traceability for items sent out for subcontracted operations. If such operations would remove traceability markings, purchase or work orders must specify a method and marking location for remarking. The contractor must also ensure that subcontractor production controls are adequate to preclude commingling of materials during processing. 3.24 Receiving Inspection 3.24.1 Products and services produced by sub-tier suppliers for incorporation in the contract end item must be subject to inspection or audit at the time of receipt by the prime prior to further processing within the prime contractor's plant or shipment to another location. 3.24.2 Receiving Inspection must include as a minimum - Verification that the traceability marking on the material agrees with that on the certification test reports. Verification that certification test reports are legible and complete. Verification that the contents of the certification test reports are in compliance with the contractually invoked specifications and requirements. 3.25 Discrepancy Reporting 3.25.1 Nonconforming products must be identified and processed in accordance with the prime contractor's procedures for controlling nonconforming products. The prime contractor must report the receipt of any nonconforming products to the responsible sub-tier supplier in accordance with established procedures. Nonconforming material records will be maintained and available for review by the government Quality Assurance Representative (QAR). 3.26 Final Inspection - The following inspections must be performed prior to Government inspection and acceptance. 3.26.1 Material Sampling - Material must be inspected for form, fit, and function. Lot acceptance must be based on zero defects and lot rejection based on one defect. The sample size must be in accordance with the sampling plan(s) in the applicable military specification or standard, federal specification or standard, or drawing to which the material was manufactured. In the absence of such sampling plans, sampling inspection must be per ANSI/ASQ-Z1.4, general inspection level II (for sample size selection code), table IIA (for sample size). SMALL LOT SIZES - For lot sizes of fifty or less, the minimum sample size must be eight units. For lot sizes of eight or less, the sample size must be one hundred percent of the lot. 3.26.2 The Manufacturer may elect to use Statistical Process Control (SPC) to assure product quality in lieu of the above attribute sampling plan, provided that the SPC methodology/system used provides acceptable products to the Government. However, the Government/Navy Receipt Inspection Activity may perform their acceptance inspection of the material using the attribute sampling plan outlined above. 3.26.3 All data concerning material verification (chemical, mechanical or physical properties), traceability (material certifications to material marking), and nondestructive test (NDT) certifications for material must be 100% inspected. The certification test reports must also be 100% inspected for completeness and legibility. 3.26.4 All material requiring traceability must be 100% inspected for traceability marking and that the marking is legible. 3.26.5 Sampling for certification of non-metallic material must be on the basis of one set of test specimens from each heat/lot or batch. 3.27 See CDRL DI-MISC-80678 (Special Emphasis C of C) - The certificate of compliance must show traceability to the marking applied on each individual item, and must contain the following information: 1. Contractor's name, address and date. 2. The contract/purchase order number (for example: N00104-11-P-FA12) 3. The National Stock Number (NSN). The 18 character National Stock Number for Special Emphasis Material includes the two digit COG, the four digit FSC, the 9 digit NIIN, and the two digit SMIC (for example: 1H 4820 012345678 L1) ("N/A" when Not Applicable). 4. Lubricants, sealants, anti-seize, and/or thread locking compounds ("N/A" when Not Applicable). 5. Certification that O-rings, packing, gaskets, or other elastomeric products were installed in a compressed state within an assembly or sub-assembly, prior to expiration of the shelf life ("N/A" when Not Applicable). 6. Manufacturer's compound number ("N/A" when Not Applicable). 7. When weld procedure submittal is required by the contract, a statement that the approval date of the qualification data precedes any production or repair welding performed on this Contract. ("N/A" when Not Applicable). 8. A statement to the effect that all items furnished on this contract are in full compliance with the specifications and requirements and list each contractually invoked conformance/compliance test performed by name and that it was performed satisfactorily. 9. Contractor's or authorized personnel's signature. 4. QUALITY ASSURANCE 4.1 Notes to DCMA QAR and the Contractor - 4.1.1 DCMA QAR and the Contractor for proprietary designs - Departures from Contractor imposed requirements, not specifically covered by the contract, must be judged individually on the basis of the effect, if any, on contractual requirements. When there is a disagreement between the Contractor and the Government representative as to the effect on contractual requirements, the departure must be considered a nonconformance and be submitted to the PCO for disposition. 4.1.2 DCMA QAR and the Contractor for proprietary designs - All records of departures from Contractor imposed requirements must be maintained and available for review at the Contractor's facility. A copy must be given to the local Government representative. A record of these departures, traceable to the applicablepart number and contract number must be submitted to the PCO. 4.1.3 DCMA QAR and the Contractor for proprietary designs - For proprietary designs, the contractor's part numbers are acceptable for reference only. The delivered material must conform to all drawings, specifications, and other contractual requirements. 4.1.4 DCMA QAR - It is the responsibility of DCMA QAR to review Non-Destructive Testing (NDT) procedures for NAVSUP Contracts/Purchase Orders. 4.1.5 DCMA QAR and the Contractor - The ECDS (Electronic Contractor Data Submission) system is available for certain data submissions and to submit questions and clarifications, and waiver requests on Contracts and Solicitations. ECDS can be found at: https://register.nslc.navy.mil/ 5. PACKAGING 5.1 Preservation, Packaging, Packing and Marking - Preservation, Packaging, Packing and Marking must be in accordance with the Contract/Purchase Order Schedule and as specified below. MIL-STD 2073 PACKAGING APPLIES AS FOUND ELSEWHERE IN THE SCHEDULE 6. NOTES 6.1 Several definitions of terms that apply to CSI items are listed below. All terms may not apply to every item. 6.1.1 The ECDS (Electronic Contractor Data Submission) system is at: https://register.nslc.navy.mil/ This application will require advance registration using a PKI Digital Certificate on a CAC. A Vendor User Guide is available as CSD001 in the CSD (Contract Support Document) Library within ECDS. 6.1.2 Critical Safety Item (CSI) - Any ship part, assembly, or support equipment containing a critical characteristic whose failure, malfunction, or absence of which could cause a catastrophic or critical failure resulting in loss of, or serious damage to the ship, or unacceptable risk of personal injury or loss of life. 6.1.3 Critical Process - As determined by the TWH, any process, operation or action performed on a Ship CSI that serves to establish a critical characteristic (such as welding, soldering, machining, polishing, cleaning, or assembling) or confirm that a critical characteristic is within drawing or specification compliance (such as, testing, measurement, or non-destructive evaluation). 6.1.4 First Article - Pre-production models, initial product samples, test samples produced to ensure a manufacturer's capability to meet full specification requirements. 6.1.5 First Article Test (FAT) - Contractually required testing and inspection of a supplier's pre-production, production, or "production representative" specimens to evaluate a manufacturer's ability to produce conforming product prior to the Government's commitment to receive subsequent production items. First Article Testing is product specific and does not assess manufacturing process controls nor does it assure the effectiveness of the manufacturer's quality program. 6.1.6 Government Source Inspection (GSI) - GSI is independent oversight performed by a government representative usually a DCMA Quality Assurance Representative (QAR)) to assure that those unique product quality and system elements, identified by the Contracting Agency as important, are observed and evaluated. 6.1.7 Quality Assurance Letter of Instruction (QALI) - A QALI is a formal document initiated by a contracting activity that provides essential requirements and instructions for contracted materials to be independently verified and accepted by a government representative prior to shipment. 6.1.8 Objective Quality Evidence (OQE) - The quantitative and qualitative data of all mechanical, chemical, and performance tests performed (as required by the applicable specification, drawing, or purchase document) to prove that the material supplied conforms to the specified requirements. 6.1.9 Surface Discontinuity - Any surface irregularity, marking, or localized change in physical character of the surface, other than dimensional, that exists infrequently at one or several places. (Examples: burrs, dents, nicks, scratches, gouges, pits, center-punches, scribes, and tool marks) Surface discontinuities less than 0.005-inch in depth are acceptable provided they do not violate any other design requirements specified in this Contract/Purchase Order. 6.1.10 Traceability Code - A code or number providing traceability to the actual chemical and mechanical properties of the specified heat, batch, or form from which the material originated. 6.1.11 Verification - An examination performed to determine compliance with a specific requirement. 6.1.12 Nonconformance - A nonconformance is defined as affecting or violating the following: - The requirements of this contract/purchase order. - Contractually invoked drawings (i.e. envelope dimensions, interface dimensions with mating parts/equipment, center of gravity, weights, piece part identification, material, etc.). - Contractually invoked federal, military, or commercial specifications and/or standards. - Form, fit, function, performance to contract requirements, reliability, maintainability, interchangeability, safety of personnel or equipment, or additional cost to the Government. 6.1.13 Waiver - A written authorization to accept an item, which during manufacture, or after having been submitted for Government inspection or acceptance, is found to depart from specified requirements, but nevertheless is considered suitable for use as is or after repair by an approved method. 6.1.14 Deviation - A specific written authorization (granted prior to the manufacture of an item) to depart from a particular requirement(s) of an item's current approved configuration documentation for a specific number of units or a specified period of time, and to accept an item which is found to depart from specified requirements, but nevertheless is considered suitable for use "as is" or after repair by an approved method. 6.1.15 Critical Waiver/Deviation - This waiver/deviation consists of a departure involving safety. 6.1.16 Major Waiver/Deviation - This waiver/deviation consists of a departure involving: - Performance - Interchangeability, Reliability, Survivability, Maintainability, or Durability of the item or its repair parts - Health or Safety - Effective Use or Operation - Weight, Stability, or Structural Integrity - System design parameters as schematics, flows, pressures or temperatures - Compartment arrangements or assigned function 6.1.17 Minor Waiver/Deviation - This waiver/deviation consists of a departure which does not involve any of the factors listed as critical or major. 6.1.18 Engineering Change (EC) - A change to the current approved configuration documentation of a configuration item at any point in the life cycle of the item. 6.1.19 Engineering Change Proposal (ECP) - A proposed Engineering Change and the documentation by which the change is described, justified, and submitted to the Government for approval or disapproval. 6.1.20 Class I ECP - A class I ECP is approved by the Government's Configuration Control Board and authorized with a contract modification. 6.1.21 Class II ECP - A class II change is typically reviewed for concurrence in classification by the local government representative, unless otherwise specified elsewhere in the contract/purchase order. 6.2 In accordance with OPNAVINST 5510.1 all documents and drawings provided by the U.S. Navy to perspective Contractors must include a "Distribution Statement" to inform the contractor of the limits of distribution, and the safeguarding of the information contained on those documents and drawings. 6.2.1 There are 7 (seven) separate distribution statement codes used for non-classified documents and drawings. The definition for each is as follows: A... approved for public release; distribution is unlimited. B... distribution authorized to US Governments agencies only. C... distribution authorized to US Government agencies and their contractors. D... distribution authorized to DoD and DoD contractors only. E... distribution authorized to DoD Components only. F... further distribution only as directed by Commander, Naval Sea Systems Command, code 09T. X... distribution is authorized to US Government agencies and private individuals or enterprises eligible to obtain export controlled technical data in accordance with OPNAVINST 5510.161. 6.3 Ordering Information for Document References - The Department of Defense Single Stock Point (DODSSP), Website http://www.dsp.dla.mil/, provides product information for the Department Of Defense Index Of Specifications and Standards (DODISS) (i.e.Military/Federal Specifications and Standards), Data Item Descriptions (DIDs), and other DODSSP Products. Most Specifications can obtained directly from http://quicksearch.dla.mil/ A. Availability of Cancelled Documents - The DODSSP offers cancelled documentsthat are required by private industry in fulfillment of contractual obligationsin paper format. Documents can be requested by phoning the Subscription Services Desk. B. Commercial Specifications, Standards, and Descriptions - These specifications, standards and descriptions are not available from Government sources. Theymay be obtained from the publishers of the applicable societies. C. Ordnance Standards (OS), Weapons Specifications (WS), and NAVORD OSTD 600 Pages - These type publications may be obtained by submitting a request to: Commander, Indian Head Division, Naval Surface Warfare Center Code 8410P, 101 Strauss Avenue Indian Head, MD 20640-5035 D. On post-award actions, requests for "Official Use Only" and "NOFORN" (Not Releasable To Foreign Nationals) documents must identify the Government ContractNumber, and must be submitted via the cognizant Defense Contract Management Command (DCMC) for certification of need for the document. On pre-award actions such requests must be submitted to the PCO for certification of need for the document. E. NOFORN Military Specifications and Standards (including Amendments, Change Notices and Supplements, but NOT interim Changes) to be ordered from: Contracting Officer NAVSUP-WSS Code 87321 5450 Carlisle Pike P.O. Box 2020 Mechanicsburg, Pa. 17055-0788 F. Nuclear Reactor Publications Assigned NAVSEA Documents and Identification Numbers (i.e. NAVSEA Welding Standard, NAVSEA 250-1500-1) are to be ordered enue: Commanding Officer NAVSUP-WSS Code 009 5450 Carlisle Pike P.O. Box 2020 Mechanicsburg, Pa. 17055-0788 G. Technical Manuals Assigned NAVSEA Identification Numbers (i.e. NAVSEA Welding And Brazing Procedure, NAVSEA S9074-AQ-GIB-010/248) are to be ordered from: Commanding Officer NAVSUP-WSS Code 1 Support Branch 700 Robbins Avenue Philadelphia, Pa. 19111-5094 H. Interim Changes and Classified Specifications must be obtained by submitting a request on DD Form 1425 to NAVSUP-WSS. 6.4 Recent Updates - A short description of recent updates to the technical requirements of this item are listed below, along with an implementation date for each issue. The notes below are only a generic quick reference and are provided for convenience only, detailed requirements will be defined elsewhere in the technical sections of this Contract/Purchase Order. ;10/20/2016 - Updated ECDS URL Jun 20 2007 - Replaced MIL-T-9047 with SAE-AMS specs Feb 24 2012 - Added appropriate UT acceptance classes May 15 2012 - Updated test method and Note 2 Jun 14 2012 - Added (Properties Specified Below Only) Sep 18 2012 - Separated Note 2 for Teflon Fiber Content - As certified by Dupont and White Teflonstring inclusions Feb 26 2009 - Clarified testing and certs only apply to pieces listed Oct 29 2010 - Added Sampling Std for LI In-Process testing Dec 20 2022 - Removed requirement for vender to submit Waivers/Deviations in ECDS Jan 05 2012 - Added WAWF to forward Approved Waivers/Deviations with final OQE Dec 17 2011 - Moved Quality Assurance Text location for Readability Apr 15 2009 - Clarified the sample size for large and small lot sizes Jan 19 2011 - Added notification of DCMA upon contract award Mar 22 2011 - Added Traceability requirements for Non-Metallic Seats Jul 02 2013 - Allowed ball valve seats to be marked using MIL-STD-792 type IX in addition to Type I May 02 2009 - Added Lubricants and Sealants to the C of C Dec 01 2011 - Moved "Notes to DCMA QAR" to QA Section Aug 27 2014 - Took out contractor's phone number requirement Jan 5 2017 - ECDS/CSD info was added to Definitions in the Notes section.; DATE OF FIRST SUBMISSION=ASREQ Paragraph 10.4 of DI-QCIC-81110 does not apply. DATE OF FIRST SUBMISSION=ASREQ Block 12 - Certification data must be submitted to Portsmouth Naval Shipyard for review and acceptance prior to each shipment of material. Certification documentation must be submitted via WAWF (Wide Area Work Flow). Enter in WAWF as follows: "Ship to" N50286 "Inspect by" N39040 "Accept by" N39040 and eMail notification field: PORT_PTNH_WAWF_Notification@navy.mil No material is to be shipped prior to the receipt of Acceptance. DATE OF FIRST SUBMISSION=ASREQ Block 4 - Paragraphs 10.2.2, 10.2.3, 10.2.4, and 10.3 of DI-MISC-80678 do not apply. Block 12 - Certification data must be submitted to Portsmouth Naval Shipyard for review and acceptance prior to each shipment of material. Certification documentation must be submitted via WAWF (Wide Area Work Flow). Enter in WAWF as follows: "Ship to" N50286 "Inspect by" N39040 "Accept by" N39040 and eMail notification field: PORT_PTNH_WAWF_Notification@navy.mil No material is to be shipped prior to the receipt of Acceptance. DATE OF FIRST SUBMISSION=ASREQ Block 4 - Paragraphs 10.2.1, 10.2.2, 10.2.3, 10.3, and 10.4 of DI-MISC-80678 do not apply. Block 12 - Certification data must be submitted to Portsmouth Naval Shipyard for review and acceptance prior to each shipment of material. Certification documentation must be submitted via WAWF (Wide Area Work Flow). Enter in WAWF as follows: "Ship to" N50286 "Inspect by" N39040 "Accept by" N39040 and eMail notification field: PORT_PTNH_WAWF_Notification@navy.mil No material is to be shipped prior to the receipt of Acceptance. DATE OF FIRST SUBMISSION=ASREQ Block 4 - Paragraphs 10.2.2, 10.2.3, 10.2.4, and 10.3 of DI-MISC-80678 do not apply. Block 12 - Certification data must be submitted to Portsmouth Naval Shipyard for review and acceptance prior to each shipment of material. Certification documentation must be submitted via WAWF (Wide Area Work Flow). Enter in WAWF as follows: "Ship to" N50286 "Inspect by" N39040 "Accept by" N39040 and eMail notification field: PORT_PTNH_WAWF_Notification@navy.mil No material is to be shipped prior to the receipt of Acceptance.

Similar Contracts

Same NAICS industry code

NAICS: 332919
New
DIBBS
STRAINER ELEMENT, SEDIMThe contract specifies the procurement of a stainless steel sediment strainer element with an 80-mesh filtration capacity, integrated magnets, and brass union fittings, designed for use in the oil lube system of a 2-inch Andale Type 103 BM Duplex Strainer applied to a turbine generator. This is a critical application item identified by part number 128000510013959 and NSN 4730-00-105-0207, supplied by TATE ANDALE, LLC. Strict prohibitions are in place against the intentional inclusion of mercury or mercury-containing compounds in the hardware or its contact surfaces, except for specific authorized exemptions such as functional mercury in batteries, fluorescent lights, instruments, sensors, controls, weapon systems, or NAVSEA-specified chemical reagents; portable devices containing mercury must be shockproof and feature a secondary containment. All packaging and preservation must comply with MIL-STD-2073-1E and DLA’s RP001 packaging requirements, with explicit exclusion of mercury in preservation materials per IP056. Marking follows MIL-STD-129 with no special codes, and palletization adheres to DLA standards. The item is to be delivered FOB origin in a quantity of nine units, with a required delivery date of February 28, 2027, and a lead time of 164 days from issue. Inspection and acceptance occur at destination, with zero tolerance for quantity variance. Delivery is addressed to DLA Distribution San Joaquin in Tracy, California, and the solicitation, issued under contract SPE7M3-26-T-7715, is a Women-Owned Small Business Set-Aside with a response deadline of August 7, 2026.
FLUID HANDLING DIVISION

POSTED

about 18 hours ago

DEADLINE

in 10 days
View Details
NAICS: 332919
New
DIBBS
ELBOW, HOSE TO BOSSThe contract pertains to the procurement of 10 units of an elbow fitting designed to connect a hose to a boss, identified by NSN 4730-01-573-4888 and part number 110035714, with a unit price of $10.00 and a total contract value of $100.00. Delivery is required within 86 days of the contract award, with shipment originating from the vendor and delivered FOB origin to the designated receiving warehouse at 25600 S Chrismann Road, Tracy, CA 95304-5000. The quantity is strictly fixed at 10 units with zero tolerance for variance, and inspection and acceptance occur at the destination. Packaging must adhere to ASTM D3951, but is superseded by any applicable DLA Master List of Technical and Quality Requirements, with all packaging and labeling required to comply with MIL-STD-129. Palletization must follow the DLA Packaging Requirements for Procurement, and the unit of issue is each, with a quantity per unit pack of one. The original required delivery date was October 14, 2026, with a need ship date of October 22, 2026. Technical and quality specifications referenced by R or I numbers are governed by the DLA Master List, with the revision in effect on the solicitation issue date controlling for this simplified acquisition. The solicitation number is SPE7M3-26-T-7525, issued on July 16, 2026, with responses due by July 27, 2026, under NAICS code 332919 and managed by the Department of Defense’s Fluid Handling Division, with William Cain as the primary point of contact.
FLUID HANDLING DIVISION

POSTED

about 18 hours ago

DEADLINE

in 2 days
View Details
NAICS: 332919
New
DIBBS
ELBOW, TUBEThe contract is for the procurement of five ELBOW, TUBE units with National Stock Number 4730-01-542-9393, under solicitation SPE7M3-26-T-7513, with a total value of $25.00 at $5.00 per unit. Delivery is required within 161 days after order placement, with a final delivery date of May 22, 2027, and FOB Origin terms apply, meaning title and risk transfer to the government upon shipment from the contractor’s facility. All items must be delivered to DLA Distribution San Diego at 3581 Cummings Road, Building 3581, San Diego, CA 92136-3581, where inspection and acceptance will occur. Packaging must adhere to ASTM D3951 but is subordinate to the DLA Master List of Technical and Quality Requirements, and all packaging and labeling must comply with MIL-STD-129, including 2D Data Matrix barcodes, NSN, contract number, and Unit Identification Code. Palletization must follow RP001: DLA Packaging Requirements for Procurement, and the unit of issue is EA with zero quantity variance allowed. Sampling for inspection must follow MIL-STD-1916 or ASQ H1331 Table 1, using a zero-defect acceptance plan unless otherwise specified, with critical, major, and minor attributes assigned AQLs of 0.1, 1.0, and 4.0 respectively; non-specified attributes are treated as major. Manufacturers must maintain a quality management system compliant with ISO 9001:2015 or equivalent. Hazardous materials must be labeled per the Hazard Communication Standard (29 CFR 1910.1200), with exceptions allowed if governed by other federal statutes, and all such labeling must be submitted for approval prior to award. The contract incorporates multiple FAR and DFARS clauses addressing employment equity, trafficking in persons, cybersecurity, safeguarding covered defense information, prohibitions on toxic substances like hexavalent chromium, export controls, and restrictions on Chinese military company equipment. Payment must be submitted electronically via WAWF, and contractors must hold a valid Unique Entity Identifier and CAGE Code. The solicitation closed on July 30, 2026, and all responses were required to be submitted through
FLUID HANDLING DIVISION

POSTED

about 18 hours ago

DEADLINE

in 2 days
View Details
NAICS: 332919
New
Federal
47--BASKETThe contract pertains to the procurement of repair parts under solicitation N0010426QBM03 with a response deadline of August 7, 2026, issued by the Naval Supply Systems Command Weapon Systems Support Mechanical division. The scope requires strict adherence to the Individual Repair Part Ordering Data (IRPOD) as the primary technical reference, with mandatory review of the IRPOD available on the BPMI website, which requires pre-registration. Pricing is valid for 60 days post-closing unless otherwise specified, and amendments such as the increase in quantity from 2 to 5 must be acknowledged. The contract invokes a strict order of precedence for conflicting documents, with contract amendments taking priority over schedules, terms, IRPOD, specifications, and drawings. Compliance with specified revision levels of referenced documents is mandatory, and deviations or waivers for non-conformances must be submitted in advance with full justification, supporting technical data, and assessment of impact on form, fit, and function. Any requested changes must be reviewed and endorsed by the Government Quality Assurance Representative before formal submission to the post-award contracting officer. Quality assurance requirements are governed by the IRPOD, obligating the contractor to maintain a government-acceptable inspection system and retain complete records accessible for government review throughout performance and beyond. Packaging must comply with MIL-PRF-23199 and related standards, with specific clarification that MIL-DTL-24466 green poly bags are permitted only when cleanliness controls from designated documents apply, and fire-retardant packaging is no longer required. The use of mercury or mercury-containing compounds is strictly prohibited in any part or contact surface. Technical data packages are governed by DD Form 1423 with detailed instructions for data submission, inspection, and acceptance codes, including designated roles for inspection authority and distribution restrictions. Delivery of certified test and inspection reports under DI-QCIC-8872 must be submitted in separate packages per contract line item, coordinated with the PCO prior to shipment, and all submissions are due at contract end. The contract includes mandatory compliance with Buy American, small business set-aside, cybersecurity maturity certification, equal opportunity, and priority rating requirements, and all contractual documents are considered issued upon electronic or postal transmission by the government.
Navsup Weapon Systems Support Mech

POSTED

about 23 hours ago

DEADLINE

in 10 days
View Details
NAICS: 332919
New
Federal
STEM,FLUID VALVEThis contract pertains to the supply of a specialized stem and disk assembly for a 1 1/2 inch globe throttle valve, designated as special emphasis Level I material due to its critical role in shipboard systems where failure could result in catastrophic consequences including loss of life or the vessel. The item must strictly conform to NAVSHIPS drawing 803-2177525, with the stem composed of ASTM-A182 Grade F6a or SAE AMS-QQ-S-763 Class 410 Condition T material, and must satisfy rigorous mechanical and chemical certification requirements. All materials must be traceable from raw stock through every manufacturing stage to the final component, with unique heat-lot or traceability markings permanently applied and verified against test reports. Certification documentation must confirm compliance with specified standards including ASTM-E18, ASTM-E140, MIL-STD-2035, and ISO-9001, and must be submitted in electronic format via WAWF with explicit identification to the contract number, NSN, and government receipt points. The contract mandates a stringent quality assurance regimen requiring the contractor to maintain an ISO-9001 based quality system, with calibration procedures aligned to ISO-10012 or ANSI-Z540.3 and ISO/IEC 17025, subject to government audit at source. All welding, brazing, and machining operations must adhere to specified Navy procedures including S9074-AQ-GIB-010/248 and S9074-AR-GIB-010A/278, with welding procedures and qualification data requiring prior Navy approval. Non-destructive testing, including dye penetrant inspection and visual inspection of hardfaced surfaces, is required, and chemical and mechanical properties must be verified per heat treat batch with 100% inspection of all certification data. Final acceptance is contingent upon zero-defect lot sampling, with all traceability markings legible and intact. Electronic signatures are permitted on certifications, provided they are individually controlled and unalterable. Delivery is subject to government inspection prior to shipment, with no material allowed to proceed without WAWF certification acceptance from Portsmouth Naval Shipyard. The contract is issued under Emergency Acquisition Flexibilities, requires bilateral acceptance, and mandates full compliance with security and small business set-aside provisions.
Navsup Weapon Systems Support Mech

POSTED

about 23 hours ago

DEADLINE

in 23 days
View Details
NAICS: 332919
New
Federal
SEAT,VALVEThis contract pertains to the procurement of ball valve seats designated as SPECIAL EMPHASIS Level I material, critical to shipboard systems where failure could result in catastrophic consequences including loss of life or vessel. The material must comply strictly with Naval Ship Systems Command drawings 803-2178494 and 803-4384678, and be manufactured from Delrin Dupont AF DE588 with defined chemical and mechanical properties including specific gravity, tensile strength, impact resistance, water absorption, and Teflon fiber content between 18–23%. All material must be traceable from raw batch to finished component via unique heat/lot/batch numbers marked directly on the product, with certification reports verifying conformity to specified test methods and values. The contractor must maintain a certified quality system per ISO-9001, ISO-10012, and ISO/IEC 17025, subject to government inspection at source, with mandatory submission of inspection records, test reports, and a certificate of compliance that links each item to its objective quality evidence. Delivery requires prior government acceptance through WAWF, with certification documentation routed to Portsmouth Naval Shipyard for review. The contract enforces strict configuration control, prohibiting unauthorized changes or deviations without formal approval from the Contracting Officer, and mandates the submission of Engineering Change Proposals for any modifications affecting form, fit, function, or interface. Mercury and mercury-containing substances are strictly prohibited, and all material must be free of intentional contamination. Subcontractors must be vetted for quality capability and their work governed by the same contractual obligations as the prime contractor. Packaging must adhere to MIL-STD-2073, and all documentation references, including military and international standards, must be accessed through ECDS or official DoD sources. The procurement is subject to Emergency Acquisition Flexibilities, classified as a rated order under the Defense Priorities and Allocations System, and designated as a total small business set-aside. All contractual documents are deemed issued upon electronic transmission, and acceptance requires bilateral agreement. The item is subject to Buy American and Federal Trade Agreement requirements, and all data submissions, waivers, and inspections must be conducted through designated government systems, with specific procedures for nonconformance reporting and corrective action.
Navsup Weapon Systems Support Mech

POSTED

about 23 hours ago

DEADLINE

in about 1 month
View Details
NAICS: 332919
New
Federal
STEM,FLUID VALVEThis contract pertains to the supply of a stem for 1/4-inch ball valves designated as SPECIAL EMPHASIS material (Level I/SUBSAFE), critical to the safe and reliable operation of shipboard systems where failure could result in catastrophic loss of life, vessel, or mission-critical capabilities. The material must conform strictly to NAVSEA drawing 6408783 and specifications including QQ-N-286, Form 2, Annealed and Age Hardened, with no weld repairs permitted. Quantitative chemical and mechanical certification is mandatory, requiring traceability from raw material through every manufacturing step to the final component via permanent, legible markings that link directly to test reports. Testing, including ultrasonic inspection and Slow Strain Rate Tensile Tests, must be conducted by approved laboratories only. All certifications must be electronically signed and unqualified, with no disclaimers allowed, and must be submitted via WAWF to Portsmouth Naval Shipyard for pre-shipment approval before any material can be shipped. The contractor must maintain a quality system compliant with ISO-9001 and ISO-10012 or MIL-I-45208 and MIL-STD-45662, subject to Government inspection at source. Traceability, material handling, and documentation control are rigorously enforced, requiring 100% verification of certifications, marking legibility, and conformity to specifications. Receiving inspections demand zero defect acceptance criteria, with strict segregation of traceable materials and procedures to prevent commingling. All subcontractors must adhere to the same standards, and the prime contractor is responsible for ensuring compliance down the supply chain. Engineering changes require formal ECPs, and waivers or deviations must be submitted and approved by the Contracting Officer before implementation. The procurement is issued under Emergency Acquisition Flexibilities, rated under DPAS as DX/DO, and falls under a total small business set-aside with mandatory compliance with Buy American provisions, Mercury-free requirements, and data delivery through ECDS and WAWF systems. The point of contact is Heather R. Jones, with all contractual documents considered issued upon electronic transmission and requiring bilateral acceptance.
Navsup Weapon Systems Support Mech

POSTED

about 23 hours ago

DEADLINE

in about 1 month
View Details

More opportunities from Department Of Defense → Navsup Weapon Systems Support Mech

Same awarding agency

NAICS: 333611
New
Federal
BEARING ASSEMBLY,TUThis contract pertains to the repair of the BEARING ASSEMBLY,TU under a fixed-price arrangement with strict compliance requirements for quality, inspection, and documentation. The work must adhere to the contractor’s approved repair standards, technical orders, and manufacturer specifications, with all repairs requiring exact alignment to the specified CAGE code 90099 and reference number 1387F17G01. Item marking must follow MIL-STD-130 Rev N, and any changes to design, materials, or part numbers require prior written approval from the NAVICP-MECH Contracting Officer, categorized under one of six code types detailing the nature of the substitution. The contractor is fully responsible for all inspection and testing procedures, ensuring compliance with both government standards and original manufacturer requirements, and must maintain complete inspection records for 365 days after final delivery. The contract mandates adherence to Buy American and Free Trade Agreements, with applicable certification requirements, and includes a total small business set-aside with restrictions on pass-through charges. A one-year warranty covers supplies after delivery, with defects must be reported within 45 days of discovery. Packaging must conform to MIL-STD-2073, and all technical documents referenced must be obtained through authorized DOD channels, with specific procedures for restricted or classified materials. The solicitation is limited to authorized distributors of the original manufacturer, who must provide proof of authorization. The North American Industry Classification System code is 333611, with a small business size standard of 1,500 employees, and the contract was posted on July 27, 2026, with a response deadline of August 24, 2026. All communication and submissions must be directed to the designated point of contact at the Naval Supply Systems Command in Mechanicsburg, Pennsylvania.
Turbine and Turbine Generator Set Units Manufacturing

POSTED

about 23 hours ago

DEADLINE

in 27 days
View Details
NAICS: 334513
New
Federal
D/P GAGEThis contract pertains to the procurement of a D/P GAGE under solicitation N0010426QEB47, issued by the Naval Supply Systems Command Weapon Systems Support Mechanical (NAVSUP WSS-MECH) under the Department of Defense, with a response deadline of August 24, 2026. The contract mandates strict adherence to technical and quality standards outlined in the Individual Repair Part Ordering Data (IRPOD), drawings, specifications, and other referenced military and commercial documents, with the IRPOD taking precedence over other contract sections in case of conflict. All submitted items must comply with revision levels specified in referenced documents, and any deviations or waiver requests must be formally submitted with detailed justification, technical data, and evidence that the proposed change will not impact the part’s quality, form, fit, or function. Contractors are required to maintain a government-acceptable inspection system and keep all inspection records accessible throughout and beyond contract performance. Packaging must conform to MIL-PRF-23199, particularly when cleanliness controls from MIL-STD-767, MIL-STD-2041, or similar standards are invoked, requiring heat-sealed envelopes and prohibiting the use of fire-retardant materials. All shipping containers and interior packaging must be marked “PROTECT FROM FREEZING.” A Certificate of Compliance per DI-MISC-81356 must accompany each delivery, issued separately for each unique NSN and item nomenclature combination. Pricing is valid for 60 days after the closing date unless otherwise specified, and all contractual documents are considered issued upon electronic transmission. The contract enforces cybersecurity maturity model certification, prohibitions on mercury, equal opportunity requirements for veterans and workers with disabilities, and mandates compliance with priority rating for national defense purposes. Technical data submitted must follow DD Form 1423 guidelines, including proper distribution statements, inspection and acceptance codes, and data item description requirements, with data pricing classified into one of four groups based on its purpose and development cost. Contractors must register to access required documentation via the BPMI e-Commerce portal and comply with cybersecurity, security, and administrative protocols outlined in associated clauses.
Instruments and Related Products Manufacturing for Measuring, Displaying, and Controlling Industrial Process Variables

POSTED

about 23 hours ago

DEADLINE

in 27 days
View Details
NAICS: 333914
New
Federal
PUMP UNIT,CENTRIFUGThis contract pertains to the repair of a centrifugal pump unit under a fixed-price arrangement, with a mandated Repair Turnaround Time (RTAT) of 503 days measured from the physical receipt of the asset at the contractor’s facility as recorded in the Commercial Asset Visibility (CAV) system. All repairs must adhere to the original manufacturer’s specifications and technical directives, with strict compliance to MIL-STD-130 Rev N for item marking. The Government requires Government Source Inspection and mandates that the contractor maintain complete inspection records for one year after final delivery. Freight is FOB Origin, and all logistics are managed by the Navy under the CAV Statement of Work. The contract includes a provision for an optional increase in quantity within 365 days of award, with pricing locked at the original unit rate unless otherwise agreed. The award will be issued bilaterally, requiring the contractor’s signed acceptance before it becomes effective. The solicitation emphasizes strict adherence to performance timelines, with financial penalties applied per unit per month for any inexcusable delays beyond the RTAT, capped at a predetermined maximum amount, without waiving other remedies such as termination for default. Pricing must reflect historical data or commercial marketplace rates, and if the item has not been previously purchased by the contracting office, the contractor must provide comparable NSNs or validated invoices to justify pricing. Contractors must be authorized distributors of the original manufacturer and must submit proof of authorization. The item is classified under NAICS code 333914 and qualifies under small business program representations with a 750-employee threshold. The contract incorporates mandatory clauses including security prohibitions, Navy use of AbilityOne support, and the requirement to use Workflow Pro’s Assist Module with Alexander Craft as the designated point of contact. All documentation must comply with distribution statement codes as outlined in OPNAVINST 5510.1, and requests for restricted documents must be formally submitted through designated Navy channels.
Measuring, Dispensing, and Other Pumping Equipment Manufacturing

POSTED

about 23 hours ago

DEADLINE

in 6 days
View Details
NAICS: 336310
New
Federal
PUMP ASSEMBLY,FUELThis contract solicitation, identified as N0010426QXB89, seeks repair services for the PUMP ASSEMBLY,FUEL under a fixed-price arrangement, with emphasis on strict adherence to military standards and government-imposed performance timelines. The contractor must provide a firm-fixed-price, not-to-exceed, or estimated quote specifically for repair, excluding test and evaluation fees unless tied to a final determination of报废或返修状态. The repair turnaround time is mandated at 265 days from receipt of the asset at the contractor’s facility, as recorded in the Commercial Asset Visibility system, with penalties applied per unit per month for late delivery unless delays are excusable. The contractor must also commit to a monthly throughput capacity and adhere to an induction expiration date of 365 days post-award, beyond which repairs require bilateral consent. All repairs must comply with MIL-STD-130 marking requirements, DFARS 252.211-7003 for Item Unique Identification, and the government’s source inspection and packaging standards, including MIL-STD-2073. Only authorized repair sources may be awarded, and proof of authorized distributor status must accompany the proposal. The contract mandates full compliance with Buy American requirements, cybersecurity maturity certification, and small business subcontracting obligations, along with strict documentation and recordkeeping practices. All quotes must include unit and total repair pricing, RTAT duration, price type designation, CAGE codes for award, inspection, and shipping locations, as well as the basis of pricing and a minimum 90-day expiration. Price reductions are enforceable for unexcused RTAT delays, capped at a specified maximum per unit per month, without precluding government remedies such as termination for default. Technical adherence to manufacturer specifications, drawings, and approved repair procedures is required, with any design or part number changes subject to prior written approval. Documentation distribution is governed by strict classification and dissemination codes per OPNAVINST 5510.1, and all submissions must be electronically sent to the designated point of contact. Responses are due by August 10, 2026, and awardees must operate under the contract’s quality assurance, inspection, and logistics framework as managed through Navy CAV or Proxy CAV.
Motor Vehicle Gasoline Engine and Engine Parts Manufacturing

POSTED

about 23 hours ago

DEADLINE

in 13 days
View Details
NAICS: 332919
New
Federal
SEAT,VALVEThis contract pertains to the supply of valve seats designated as Special Emphasis Level I material for use in critical shipboard systems, where failure could result in catastrophic consequences including loss of life or vessel. The seats must conform to Naval Sea Systems Command Drawing 803-5001003 and be manufactured from Teflon (Polytetrafluoroethylene) per ASTM-D4894, meeting strict chemical and mechanical property requirements including tensile strength, elongation, melting point, specific gravity, hardness, and water absorption. Traceability is mandatory from the raw material through every process step to the final component, requiring unique heat-lot or batch markings on each seat and accompanying certification reports that link directly to test data. All material must be free of mercury and comply with ISO-9001, ISO-10012, and ISO/IEC 17025 quality and calibration standards, with documented quality systems subject to government audit. The contractor must maintain complete configuration control, submit Engineering Change Proposals for any alterations, and ensure all subcontractors adhere to the same stringent quality and traceability requirements. Deliverables must be accompanied by a Certificate of Compliance that explicitly confirms adherence to all contractual specifications, including applicable drawings and standards, and must be submitted via Wide Area WorkFlow (WAWF) with designated shipping, inspection, and acceptance codes to Portsmouth Naval Shipyard prior to any shipment. Government inspections are required at source, and the contractor must make all testing equipment and records available for review. Packaging must follow MIL-STD-2073, and all documentation must be submitted electronically through the Electronic Contractor Data Submission system. The solicitation is issued under Emergency Acquisition Flexibilities and will be awarded bilaterally upon contractor acceptance. It is a total small business set-aside, subject to Buy American and Defense Priorities and Allocations System (DPAS) DX-ranking, and requires full compliance with all applicable Navy regulations including NAVSEA 0948-LP-045-7010. Material certification data must be reviewed and accepted by the Portsmouth Naval Shipyard before any shipment is authorized.
Other Metal Valve and Pipe Fitting Manufacturing

POSTED

about 23 hours ago

DEADLINE

in about 1 month
View Details
NAICS: 333914
New
Federal
43--PUMP UNIT,CENTRIFUG, IN REPAIR/MODIFICATION OFThis contract pertains to the repair and modification of the PUMP UNIT, CENTRIFUG, under a firm fixed-price structure, with strict adherence to technical and quality standards defined by the Navy. The work must comply with specified Cage Code and reference number requirements, and any changes to design, material, or part numbers require prior written approval from the NAVICP-MECH Contracting Officer, categorized under one of six defined change codes ranging from simple part number updates to non-interchangeable redesigns. All repairs must follow approved contractor and government technical documentation, including drawings, manuals, and operational directives. Quality assurance is a shared responsibility, with the contractor obligated to maintain comprehensive inspection records for at least 365 days after final delivery, ensuring all submitted items meet contract requirements without reliance on government sampling to approve defective material. The contract incorporates multiple federal and Department of Defense clauses covering item identification, valuation, security, and compliance, including safeguarding sensitive conventional arms and explosives, mandatory use of Workflow Pro for procurement, and adherence to small business subcontracting and equal opportunity regulations for veterans and workers with disabilities. Transportation of supplies is governed by sea shipment protocols, and payment instructions align with the Wide Area Workflow system using a combined invoice and receiving format. The solicitation, issued by the Naval Supply Systems Command Weapon Systems Support in Mechanicsburg, Pennsylvania, requires a signed proposal by August 24, 2026; emailed submissions are accepted, but NECO quotes are non-responsive. The contract references the mandatory use of annual representations and certifications under Deviation 2026-O0043 and is tied to NAICS code 333914 for pump and pumping equipment manufacturing.
Measuring, Dispensing, and Other Pumping Equipment Manufacturing

POSTED

about 23 hours ago

DEADLINE

in 27 days
View Details
NAICS: 332919
New
Federal
STEM,FLUID VALVEThis contract pertains to the procurement of a stem assembly for a size 6 inch ball valve, designated as SPECIAL EMPHASIS material (Level I/SUBSAFE), intended for use in a critical shipboard system where failure could result in catastrophic consequences including loss of life or vessel. The material, specifically QQ-N-286 annealed and age-hardened stem, must meet stringent quality, traceability, and certification standards, including mandatory chemical and mechanical testing, dye penetrant and ultrasonic inspections, and strict adherence to military and industry specifications such as MIL-STD-2035, MIL-STD-792, FED-STD-H28, and ISO-9001. Traceability is mandatory from raw material to finished component, requiring permanent, legible markings and documented certification linking material properties to heat-lot numbers, with electronic signatures accepted as legally valid under controlled procedures. Any deviation or waiver must be formally submitted and approved by the Contracting Officer, and must be classified as Critical, Major, or Minor, with full documentation of impact on safety, performance, and logistics. The contractor must maintain a certified quality system compliant with ISO-9001 or MIL-I-45208, subject to Government quality assurance oversight at source, and must ensure all subcontractors adhere to the same rigorous standards. Inspection and test reports must be 100% complete, legible, and directly tied to traceability marks on each item, with no disclaimers permitted in certifications. Material handling requires segregation, preservation of markings through all manufacturing steps, and verification of filler metals used in welds. Final inspection mandates zero-defect acceptance for all Lot I items using ANSI/ASQ Z1.4 sampling, and all deliverables must be submitted via WAWF to the Portsmouth Naval Shipyard for review and prior acceptance prior to shipment. The contract enforces Buy American requirements, prohibits mercury, mandates Configuration Control and Engineering Change Proposals for any form, fit, or function modifications, and restricts distribution of technical documents to authorized U.S. government personnel and contractors only. All certifications must be electronically submitted through WAWF with specific ship-to, inspect-by, and accept-by codes, and failure to comply results in immediate rejection of material.
Other Metal Valve and Pipe Fitting Manufacturing

POSTED

about 23 hours ago

DEADLINE

in about 1 month
View Details
NAICS: 332919
New
Federal
STEM,FLUID VALVEThis contract pertains to the supply of a critical stem component for a shipboard system, designated as SPECIAL EMPHASIS Level I material due to its essential role in preventing catastrophic failure, loss of life, or loss of the vessel. The item must comply with Naval Ship Systems Command Drawing 803-4385050 and associated drawings, with strict adherence to QQ-N-286 Alloy UNS N05500 material specifications, including annealing and age hardening. No weld repair is permitted on this material. Comprehensive quality controls are mandated, including ultrasonic and dye penetrant inspections, Slow Strain Rate Tensile Testing performed only by approved laboratories, and full traceability from raw material through final fabrication using unique heat-lot markings applied per MIL-STD-792. Certification of compliance must accompany every shipment, verifying chemical and mechanical properties, inspection results, and conformance to all referenced standards including ISO-9001, MIL-I-45208, and MIL-STD-45662. Electronic signatures are accepted but must be uniquely controlled and authenticated per strict protocol, with no disclaimers permitted on certifications. All shipments require submission of certification data via Wide Area WorkFlow (WAWF) to Portsmouth Naval Shipyard for prior review and acceptance, with no material allowed to ship without formal approval. The prime contractor must maintain a documented quality system, ensure all subcontractors comply with stringent traceability and inspection requirements, and implement rigorous receiving and final inspection procedures based on zero-defect acceptance criteria, with 100% verification of certification documents and traceability markings. Changes to design, material, or process require formal Engineering Change Proposals and government approval. The contract enforces Buy American and Mercury-Free requirements, prohibits unauthorized marking, and mandates that all material handling, storage, and subcontractor oversight maintain absolute integrity of traceability from origin to final assembly. Government Quality Assurance Representatives retain full authority for source inspection and audit, and all nonconformances, waivers, or deviations must be formally submitted, classified, and approved prior to implementation. Failure to meet these requirements results in immediate rejection of material.
Other Metal Valve and Pipe Fitting Manufacturing

POSTED

about 23 hours ago

DEADLINE

in about 1 month
View Details