Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, November 11 at 2:00 PM ET

Register Free →

This Government Contract opportunity from Department Of Justice was posted on August 31, 2011. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

Pre-Engineered Metal Building

Awarded
RFQP05141100026Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

General Info

Contract Value

$42,500

NAICS

444190 - Other Building Material Dealers

Place of Performance

FCI Seagoville 2113 N Highway 175, SEAGOVILLE, TX, 75159, USA

Set-Aside

NONE

Award Issued Date

Documents

2

Pre+Enginered+Metal+Building+Mod+1.pdf

PDF

Pre+Enginered+Metal+Building.pdf

PDF

AI Contract Breakdown

Uniform Contract Format

Contract not broken down yet

CLEATUS splits the solicitation into Uniform Contract Format (UCF) sections: scope, pricing, deliverables, and evaluation criteria.

Timeline

1 update
PhaseAwarded
Posted

Combined Synopsis

Notice updated

The notice description changed.

Awarded

Contract was awarded

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Justice → Fci Seagoville
Contacts2 people available
OfficeSEAGOVILLE, TX, 75159, USA
Office AddressSEAGOVILLE, TX, 75159, USA
Contacts
Tammie O. JohnsonSupervisor ContractSpecialist
Diana BensonContract Specialist

Full Description

Show more
Metal building; pre-engineered, bolt up, size 50' x 100 ', 14' eaves. Tapered column clear span, base angle and trim. Roof slope 3/12, live load 20/12, wind load 90, ground, snow 5, collateral load 10. Bay spacing 25', # bays 4, roof members must support qypsum ceiling per MBMA tables for deflection limits L/360 required. Doors-walk through 5, size 3'x7', framed openings only,(see attached drawing- Section 4: List of Attachments; pages 1 and 2), 3" white vinyl insulation on walls and roof. Gutters on both sidewalls with one downspout per bay and at corners. All trim, gutters and downspouts shall be dark brown, (koko brown). Wall panels shall be saddle tan, roof color: white all painted, PBR panels shall be 26 gauge with a minimum 25 years paint warranty. Included: furnished trim for 19 windows size: 3/0x 4/0. All bolts, screws, gaskets, seals, engineered drawings with bolt pattern.

Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS