Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, October 28 at 2:00 PM ET

Register Free →

This Combined Synopsis/Solicitation opportunity from Department Of Defense was posted on September 1, 2009. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

Purchase and Install Upgrades to Live Fire Trainer

Closed
FA480309QA346aFederal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 236210
New
Federal
Building 215 Clean Room HEPA Filter Replacement
Solicitation # RFI-195000-26-00181
The National Institute of Standards and Technology is conducting market research through a Request for Information for the Building 215 Advanced Measurement Laboratory cleanroom repair and HEPA filter replacement project in Gaithersburg, Maryland. This initiative follows a previous solicitation that failed to produce an acceptable offer, prompting NIST to reassess its acquisition strategy and seek industry feedback on constructability, cost, and schedule feasibility. The project scope involves the modernization of an 1,800 square meter facility, including the replacement of approximately 1,200 HEPA filters, 70 VAV terminal units, and 54 airflow monitoring devices, as well as the installation of 32 exhaust air control valves and associated ductwork repairs, testing, and recertification. A critical component of the project is the proposed phasing plan, which aims to minimize research disruptions by utilizing 19 construction phases, including 18 critical cleanroom outage phases. Each critical outage is currently envisioned as a nine-day window starting Friday evening and requiring 24/7 operations to achieve ready-for-re-occupancy by the following Monday morning. NIST is specifically requesting rough-order-of-magnitude cost estimates and industry input on whether this aggressive outage schedule is realistic or if it creates prohibitive risks and costs. Responses, including company experience and recommendations for improving competition and project execution, are due by October 14, 2026.
Department Of Commerce Nist

POSTED

1 day ago

DEADLINE

in 13 days
NAICS: 236210
New
Federal
Sources Sought - POST TEST LITHIUM BATTERY STORAGE
Solicitation # N00167-27-RFPREQ-CD-102-0002
The Naval Sea Systems Command Naval Surface Warfare Center Carderock Division is conducting a sources sought effort for the construction of a Post-Test Lithium Battery Storage Facility in West Bethesda, Maryland. This project, classified under NAICS code 236210 for Industrial Building Construction, involves the creation of a storage area featuring a non-flammable single-pitch sloped roof, a perimeter fence with a gate, 3-hour rated firewalls, and concrete walls for large battery storage. Additional requirements include low-voltage outlets, pole-mounted LED flood lighting, and a dedicated forklift access road. The effort must be completed within 210 days of the award and adhere to Unified Facilities Guide Specifications and other stringent technical criteria. This notice is not a request for proposal, and no award will be made directly from this notice. Interested small and large businesses must submit a capability statement and a Rough Order of Magnitude by 1700 EST on 18 November 2026 to Heather Valiga. The government will use these responses to determine the future acquisition strategy. Because the project is located on a secure military installation, all personnel must obtain proper clearances and credentials. Key deliverables include an Activity Hazard Analysis and a detailed schedule due within five days of the pre-construction meeting, as well as a personnel list provided seven days before the start date.
Nswc Carderock

POSTED

1 day ago

DEADLINE

in 29 days
NAICS: 236210
New
SLED
Arrowhead Regional Medical Center Lot 1 Parking Structure
Solicitation # 2026010330
The County of San Bernardino is soliciting the construction of the Arrowhead Regional Medical Center Lot 1 Parking Structure located at 400 North Pepper Avenue in Colton, California. The project consists of a post-tensioned, cast-in-place structure spanning up to 500,000 square feet across six levels, providing up to 1,600 parking spaces. Key design elements include a finished exterior with an architectural mesh facade on the first floor, two banks of two elevators, and the installation of photovoltaic panels on the top level. The facility will be restricted to employees via badge access and will feature security enhancements such as LED lighting, emergency call boxes, security cameras, and locked gates. The project must comply with the California Building Code, the Americans with Disabilities Act, the 2022 California Building Energy Efficiency Standards (Title 24), and the California Green Building Standards Code (CALGreen) for electric vehicle charging stations. Environmental mitigation includes a landscape plan to offset the removal of approximately 51 trees. To maintain parking capacity during construction, a temporary surface parking lot will be operated at 1351 West Valley Boulevard with shuttle services provided to the campus. The project has undergone CEQA review, resulting in a Mitigated Negative Declaration confirming that the project will not have significant environmental impacts provided mitigation measures are implemented.
San Bernardino County

POSTED

1 day ago

DEADLINE

N/A

General Info

NAICS

236210 - Industrial Building Construction

Place of Performance

452 Killian Ave, SHAW AFB, SC, 29152, USA

Set-Aside

SBA

Documents

2

Signed+Brand+Name+J%26A.pdf

PDF

SOW+for+Upgrade+Live+Fire+Trainer.doc

DOC

AI Contract Breakdown

Uniform Contract Format

Contract not broken down yet

CLEATUS splits the solicitation into Uniform Contract Format (UCF) sections: scope, pricing, deliverables, and evaluation criteria.

Timeline

PhaseClosed
Posted

Combined Synopsis

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Start your free trial to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Defense → FA4803 20 Cons Lgca
Contacts2 people available
OfficeSHAW AFB, SC, 29152-5125, USA
Office AddressSHAW AFB, SC, 29152-5125, USA
Contacts
Caroline L BachelierContract Specialist
Ronald P. AlexanderContracting Officer

Full Description

Show more
This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in Subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation, quotes are being requested and a written solicitation will not be issued. This solicitation will be evaluated and awarded per the prescribed procedures of FAR Part 13, Simplified Acquisition Procedures. The solicitation number for this procurement is FA4803-09-Q-A346 and is issued as a Request for Quotation (RFQ). This solicitation document and incorporated provisions and clauses are those in effect through the Federal Acquisition Circular (FAC) 2005-36, Defense Federal Acquisition Regulation Supplement Change Notice (DCN) 20090825 and Air Force Acquisition Circular (AFAC) 2009-0803. The North American Industry Classification System code for this acquisition is 236210, with a Small Business Size Standard of $33.5 million. This acquisition is a 100% Small Business Set-Aside. This is Firm Fixed Price procurement and will be procured using commercial item procedures and award will be based on price. The contractor shall purchase and install "Westec" Stainless Steel Insulated liner system and remove the old system on the second floor burn room, provide new "Scout" temperature monitoring system to include new thermocouples, install three new rappelling anchors for the roof of the facilities, provide one burn room door for the second floor burn room and six (6) new "westemp" panels for the second floor burn room in building 9235, Shaw AFB South Carolina, 29152. The RFQ's submitted shall contain the following information: RFQ number, time specified for receipt of offers, name, address, telephone number of offeror, price, any discount terms and acknowledgement of all solicitation amendments (if applicable). Quote shall also contain all other documentation specified herein. Offerors shall include a statement specifying the extent of agreement with all terms, conditions and provisions included in the solicitation. Period of Acceptance for Offerors: The offeror agrees to hold its offer firm for 30 calendar days from the date specified for receipt of offers, unless another time period is stated in an addendum to the solicitation. Late offers: Request for Quotations or modification of quotes received at the address specified for the receipt of offers after the exact time specified for receipt of offers will be handled in accordance with FAR 52.212-1(f). The following FAR clauses and provisions apply to this acquisition: FAR 52.212-1, Instructions to Offerors -- Commercial Items (Jun 2008). Late offers: Request for Quotations or modification of quotes received at the address specified for the receipt of offers after the exact time specified for receipt of offers will not be considered. Evaluation/Award: The Government will award a single contract resulting from this solicitation to the responsive responsible offeror whose quote conforms to the solicitation and will be most advantageous to the Government. 52.212-2, Evaluation -- Commercial Items (Jan 1999) (a) The Government will award a contract resulting from this solicitation to the responsible offeror whose offer conforming to the solicitation will be most advantageous to the Government, price and other factors considered. The following factors shall be used to evaluate offers: 1. Price (c) A written notice of award or acceptance of an offer mailed or otherwise furnished to the successful offeror within the time for acceptance specified in the offer, shall result in a binding contract without further action by either party. Before the offer's specified expiration time, the Government may accept an offer (or part of an offer), whether or not there are negotiations after its receipt, unless a written notice of withdrawal is received before award. (End of Provision) Offerors shall complete a copy of the Online Offeror Representations and Certifications Application. Please refer to http://orca.bpn.gov/login.aspx for information regarding the Online Representation and Certification Application process. The following provisions and clauses are hereby incorporated by reference: FAR 52.212-3, Offeror Representations and Certifications -Commercial Items; FAR 52.212-4, Contract Terms and Conditions - Commercial Items; FAR 52.212-5, Contract Terms and Conditions Required to Implement Statutes or Executive Orders- Commercial Items paragraphs (a) (b) (5)(i) (14) (15) (16) (17) (18) (19) (20) (21) (22) (36); FAR 52.222-3 Convict Labor (E.O. 11755); FAR 52.222-26 Equal Opportunity (E.O. 11246); FAR 52.222-35, Affirmative Action for Special Disabled and Vietnam Era Veterans (38 U.S.C. 4212); FAR 52.222-36 Affirmative Action for Handicapped Workers (29 U.S.C. 793), FAR 52.222-37, Employment Reports on Special Disable Veterans and Veterans of the Vietnam Era (38 U.S.C. 4212); FAR 52.247-64, Preference for Privately Owned U.S. Flag Commercial Vessels (46 U.S.C. 1241); DFARS 252.212-7001, Contract Terms and Conditions Required to Implement Statutes or Executive Orders Applicable to Defense Acquisitions of Commercial Items; DFARS 252.225-7036, Buy American Act - Free Trade Agreements - Balance of Payments Program (JUN 2005) (Alternate I) (JAN 2005) (41 U.S.C. 10a-10d and 19 U.S.C. 3301 note). 5352.201-9101 Ombudsman - ACC Ombudsman follows: Ms Lorraine Cotton, 129 Andrews Street, Langley AFB VA 23665-2769, Phone: (757) 764-5371 FAX: (757) 764-4400, Email: lori.cotton@langley.af.mil. FAR52.219-28 - Post-Award Small Business Program Representation, The Contractor represents that it [ ] is, [ ] is not a small business concern under NAICS Code ______________ assigned to contract number ______________.[Contractor to sign and date and insert authorized signer's name and title]. All quotes shall be marked with the Request for Quotation Number, Date and Time. Only Facsimile and electronic mail quotes will be accepted. NOTE: ALL OFFERORS MUST BE REGISTERED IN THE CENTRAL CONTRACTOR REGISTRATION (CCR) BEFORE BEING CONSIDERED FOR AWARD. Information concerning CCR requirements may be viewed via the Internet at http://www.ccr.gov or by calling the CCR Registration Center at 1-888-227-2423. Offerors shall include completed copy of the Online Offeror Representations and Certifications Application. Please refer to http://orca.bpn.gov/login.aspx for information regarding the Online Representation and Certification Application process. Quotations may be submitted via fax to (803)-895-5339 to the attention of Lt Caroline Bachelier, (803)-895-5348 or by e-mail to caroline.bachelier@shaw.af.mil. Quotations are to be received no later than 1400 EST, 16 September 09.

More opportunities from Department Of Defense → FA4803 20 Cons Lgca

Same awarding agency

NAICS: 236220
Federal
FY27 MACC
Solicitation # FA480326B0006
Solicitation FA480326B0006 is for a competitive total small business set-aside Multiple Award Construction Contract (MACC) using an Indefinite-Delivery/Indefinite-Quantity (IDIQ) structure. The contract supports the 20th Civil Engineer Squadron at Shaw Air Force Base, South Carolina, as well as the Poinsett Electronic Warfare Range, Wateree Recreational Area, and other identified sites. This seven-year vehicle has a total aggregate maximum value of 175 million dollars and will result in the award of seven IDIQ contracts, with the top four being active. The scope of work encompasses minor construction, repair, maintenance, and renovation projects, utilizing task order methods such as simple construction, design-build, and design-bid-build. The government will rank offerors from low to high based on a seed project to determine awards. To be considered responsive, offerors must be registered in SAM, provide a past performance questionnaire, and demonstrate financial capability through a bank reference and notarized bonding information showing a minimum capacity of 7.5 million dollars per project and 40 million dollars aggregate. All task orders will be firm-fixed-price, and contractors must maintain a quality control system complying with FAR 52.246-12. Performance is subject to strict base access requirements, including REAL ID Act compliance, and adherence to Department of Defense Unified Facilities Criteria and Shaw AFB Design and Construction Standards.
Commercial and Institutional Building Construction

POSTED

7 days ago

DEADLINE

in 8 days
View Details

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS