Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, September 16 at 2:00 PM EDT

Register Free →

This Sources Sought opportunity from Department Of Defense was posted on May 15, 2026. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

Reagent/Rental for two fully automated, random-access analyzers for 59th Medical Wing, Lackland Air Force Base, Texas

Closed
HT940826RFI0003Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

AI Contract Overview

Show more

The Defense Health Agency is conducting market research through a Sources Sought Notice to identify qualified vendors capable of providing two fully automated, random-access Bio-Rad Bioplex 2200 analyzer systems and associated reagents for the 59th Medical Wing at Wilford Hall Ambulatory Surgical Center in Joint Base San Antonio, Texas. The analyzers must meet strict technical specifications including a test menu of over 50 assays for autoimmune and infectious diseases, high throughput of up to 1,200 results per hour, a time-to-first result under 45 minutes, and a compact physical footprint limited to 4.4 feet in height, 4 feet 3 inches in width, and 2 feet 10 inches in depth with minimal operational clearance. The systems must require less than 10 minutes of daily maintenance and no more than 30 minutes weekly, with automated tracking to ensure compliance. Assay performance must meet defined sensitivity and specificity benchmarks for MMRV IgG testing, including 100% specificity for Measles, Mumps, and Varicella zoster, and consistent sensitivity ranges across all four targets. The contractor must supply the two analyzer systems along with all necessary consumables—including 450 MMRV IgG test kits, wash buffer, sheath fluid, calibrators, probe seals, syringes, waste bags, and other required items totaling 768 units—as well as two handheld barcode scanners, two printers, and two UPS backup systems. The contractor is responsible for full lifecycle support: installation, training, preventive maintenance, emergency repair, transport, and removal, all at no additional cost, with guaranteed 24-hour response time for critical issues. Emergency telephone support is required during standard business hours, Monday through Friday, and on-site Field Service Representative dispatch must be available as needed. Delivery of the equipment must occur within 30 days of order placement to the specified location in Texas. While no contract is being awarded based on this notice, responses will inform potential future solicitations, and respondents are required to submit a concise five-page document by May 29, 2026, including company details, NAICS 334516 size certification, SAM.gov registration status, and country of origin for all products manufactured. The agency will not pay for responses or commit to any award, and submissions must exclude proprietary or sensitive information.

General Info

DHA seeks vendors for reagent rentals, analyzer support, and maintenance at Lackland AFB, Texas.

Agency

Department Of Defense → Defense Health AgencyView Agency

NAICS

334516 - Analytical Laboratory Instrument ManufacturingView NAICS

Place of Performance

DWG, TX, 78236, USA

Set-Aside

NONE

Documents

(1)

Statement of Work for Bio-Rad Reagents and Equipment Support

PDFsow

AI Contract Breakdown

Uniform Contract Format

Sign up to view the full breakdown with detailed analysis of each section.

Timeline

PhaseClosed
Posted

Sources Sought

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Start your free trial to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Defense → Defense Health Agency
Contacts2 people available
OfficeSAN ANTONIO, TX, 78230, USA
Organization / Agency
Department Of Defense → Defense Health Agency
View Agency Profile
Office AddressSAN ANTONIO, TX, 78230, USA
Contacts
Khaireyal Barcia

Full Description

Show more

1. Introduction


This is a Request for Information (RFI)/Sources Sought Notice (SSN). The Defense Health Agency (DHA) is conducting market research to determine if qualified businesses exist that can provide Reagent/Rental for two fully automated, random-access analyzers for 59th Medical Wing, Lackland Air Force Base, TX.  This publication seeks to learn more about potentially capable vendors. This is not a solicitation, nor is it a request for proposals. This notice is for informational and planning purposes only and does not constitute a commitment, implied or otherwise, that a solicitation will be issued. The Government is not obligated to award a contract as a result of this notice.



2. Program Details


The 59 MDW has a potential requirement for two analyzer systems meeting, or exceeding, the technical specifications below. The system must be designed for high-volume laboratories, capable of testing up to 25 different analytes from a single sample tube. Must have a test menu that includes over 50 assays for autoimmune, infectious disease, and specialty immunoassay testing. Must streamlines workflow with high throughput (up to 1,200 results/hour), rapid time-to-first result (45 minutes), and broad assay capability in autoimmune and infectious diseases. The system must offer a significant reduction in labor costs and improved patient care through faster, more detailed diagnostic information.



Salient Characteristic of the Analyzer requirement:


Physical Dimensions (space is extremely limited)


Height: no larger than 4.4’


Width: no larger than 4’3”


Depth: no larger than 2’10”


Operational clearance approximately 3’


Minimal System Maintenance:


Less than 10 minutes per day


Automated weekly maintenance requires 30 minutes or less


Electronic tracking of required maintenance tasks


Ensures maintenance is completed when due


Minimal hands-on time and labor devoted to maintenance procedures


Test Specifications-MMRV


Assay                             Specificity


Measles IgG                100% (93/93)


Mumps IgG                  100% (83/83


Rubella IgG                  97.6% (123/143)


Varicella zoster          100% (143/143)


Assay                               Sensitivity


Measles IgG                  94.6% - 95.7%


Mumps IgG                    98.1%–98.8%


Rubella IgG                    94%–98.8%


Varicella zoster            92.2%–96.8%



Required Consumables for Analyzers


MMRV IgG100 tests   |   QTY: 450


Vessel Reaction 1000 bag   |   QTY: 60


Bag Waste Biohazard 14x19   |   QTY: 66


Sheath Fluid 2 PA   |   QTY: 36


Wash Buffer   |   QTY: 71


Detector Calibration Pack   |   QTY: 14


Detector Clean Pack   |   QTY: 14


Probe cleaning Sol. Btls 4   |   QTY: 14


Sodium Hydroxide 1.0N liter   |   QTY: 2


Probe Seal   |   QTY: 1


Probe Reagent   |   QTY: 1


Sample Syringe, 2.5ml   |   QTY: 2


Reagent Syring, 0.25ml   |   QTY: 2


Analyzer Calibrator   |   QTY: 13


Ctrl Set MMRV    |   QTY: 14


Analyzer System Cmplt    |   QTY: 2


Handheld Barcode Scanner   |   QTY:  2


Printer   |   QTY: 2


UPS Backup System   |   QTY: 2


Total Quantity: 768



3. Scope of Work


The Contractor shall provide and deliver Bio-Rad reagents on a cost per kit (CPK) reagent basis used for performing clinical immunoassay analysis on Bio-Rad Bioplex 2200 as required by Wilford Hall Ambulatory Surgical Center (WHASC).


The contractor shall provide all labor, materials, equipment, preventive maintenance of equipment, training on equipment, transportation, consumables, installation/removal of equipment and major/incidental repair services of equipment at no additional costs under this contract to support the performance of immunoassay analysis on the Bio-Rad Bioplex 2200.


The contractor shall provide emergency telephone assistance during hours of operations 08:00am through 05:00pm (CST) five days per week, Mondays through Fridays. If additional, on-site troubleshooting by a Field Service Representative (FSR) is required to resolve the issue, the Contractor shall dispatch an FSR.



4. Anticipated Delivery


Delivery of the Analyzer systems shall occur within 30 days after receipt of an order. Delivery shall be made to the 59th MDW location at Wilford Hall Ambulatory Surgical Center (WHASC), Joint Base San Antonio (JBSA), Lackland Air Force Base (AFB), TX.



5. Information Requested from Industry Sources


DHA invites industry sources to review this notice carefully and to familiarize themselves with this Sources Sought Notice.  Thereafter, DHA encourages those sources to submit the following:



Company Summary:


a.    Notice ID and its Title for this posting


b.    Your company’s name, address, website address and Unique Entity Identifier (if the company has one)


c.    Company point of contact, their phone number, and their email address


d.    Your company’s size status as it relates to NAICS 334516 – Analytical Laboratory Instrument Manufacturing.  See table of business size standards at https://www.sba.gov/document/support-table-size-standards for more information.


e.    Indicate whether your company has an active registration for procurement purposes in sam.gov.



•    Place of Manufacture/Origin: Please identify whether the potential product is manufactured in whole or in part in the United States. If it is manufactured outside of the United States, in whole or in part, please identify the country of manufacture.



•    Existing Contract Vehicles: Indicate whether your company has a GSA Multiple Award Schedule contract or other federal contract under which NIST would be authorized to place an order, and if so, provide a copy of that contract (including contract number, name and contact information for contracting officer, contract SOW, contract terms and conditions and contract prices).



The Government reserves the right to follow up on a one-on-one basis with respondents to request additional information or clarifications about information submitted.



THIS IS STRICTLY MARKET RESEARCH. DHA WILL NOT RESPOND TO QUESTIONS REGARDING THE RESULTS OF THIS MARKET RESEARCH. REQUESTS FOR ADDITIONAL INFORMATION WILL NOT BE PROVIDED



6. Response Instructions


Interested businesses should submit their responses electronically to Mr. Joe Wells (joe.d.wells3.civ@health.mil) and Ms. Khaireyal Barcia (khaireyal.y.barcia,civ@health.mil) no later than 04:00pm CST on 29 May 2026.



•    Microsoft Word (or PDF) document, and 11 or 12-point font.


•    Submission shall not exceed five (5) pages. Any cover page OR Standard Commercial Pricing Sections is not included in the total page count.


•    Respondents are requested to state their capabilities and expertise in clear and concise language.


•    Respondents are strongly encouraged to avoid use of excessive marketing and sales language.



Cover Page


Respondents shall include the following Business information on the Cover Page:



a.    Sources Sought Notice number, title, and date of issuance


b.    Unique Entity ID


c.    Company Name


d.    Company Address


e.    Company website address,


f.    Company Point of Contact, Phone, and Email address


g.    Validation of business status under NAICS: 334516 – Analytical Laboratory Instrument Manufacturing. See table of business size standards at https://www.sba.gov/document/support-table-size-standards for more information. 


h.    Registration in the System for Awards Management (SAM.gov) is required for the Federal Government to make an award. If you are not registered in SAM.gov and require assistance, please let us know.



This notice is for information and planning purposes only and shall not be construed as a solicitation or as an obligation on the part of DHA.



DHA does not intend to award a contract based on responses nor otherwise pay for the preparation of any information submitted. As a result of this notice, DHA may issue a Request for Quote (RFQ).



THERE IS NO SOLICITATION AVAILABLE AT THIS TIME. However, should such a requirement materialize, no basis for claims against DHA shall arise because of a response to this notice or DHA’s use of such information as either part of our evaluation



Confidentiality


Do not include proprietary, classified, confidential, or sensitive information in response to this notice. The Government reserves the right to use any non-proprietary information as it deems appropriate in establishing requirements for its upcoming acquisition.



DISCLAIMER


This notice does not obligate the Government to award a contract or otherwise pay for the information provided in response. The Government reserves the right to use information provided by respondents for any purpose deemed necessary and legally appropriate. Any organization responding to this notice should ensure that its response is complete and sufficiently detailed. Information provided will be used to help DHA assess alternatives available for the potential requirement and may lead to the development of a solicitation. Respondents are advised that the Government is under no obligation to provide feedback to respondents with respect to any information submitted. After a review of the responses received and other market research, DHA may publish a solicitation on SAM.gov or on GSA ebuy, depending on the acquisition strategy chosen by DHA. DHA will not consider proposals submitted directly in response to this notice for award. Responses received after the closing date for this notice may not be considered for market research purposes.

More opportunities from Department Of Defense → Defense Health Agency

Same awarding agency

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 650+ contractors already using CLEATUS