REPAIRS TO IFO ADMINISTRATIVE OFFICE, F-160

Active
Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

General Info

Agency

Department Of The Navy → Navfac Far EastView Agency

NAICS

N/A

Place of Performance

USA

Set-Aside

NONE

Documents

(0)

No documents available

AI Contract Breakdown

Uniform Contract Format

No contract breakdown available.

Cannot generate Contract Breakdown because no documents were found from this contract's source.

Timeline

Posted

forecast

Ready to pursue this opportunity?

Start your free trial to track this contract, build proposals with AI assistance, and manage your pipeline.

Organization & Contact Information

Show more
AgencyDepartment Of The Navy → Navfac Far East
ContactsNo contacts available
OfficeN/A
Organization / Agency
Department Of The Navy → Navfac Far East
View Agency Profile
Office AddressN/A
ContactsNo contact information available

Full Description

Show more
Project will replace 2,760-sf aggregate-type built-up roof with smooth-type and will install sprinkler and fire alarm system. Additional scope of work were based on ICAP inspection and Builder Generated Requirements deficiencies of the facility. Project will include the following: 1] Replace men /women toilet with wall mounted flush valve water closet (2-ea), wall mounted urinal (1-ea), lavatory (2-ea) and service sink (2-ea) complete with all required accessories, 2] Replace 2-ea roof exhaust fan complete with all required accessories serving mech'l room area and men/ women rest room, 3] Replace 1-each Air Cooled Condensing Unit (ACCU) and 1-each Air Handling Unit (AHU), including ducting system approx. 250-lf, 4], Replace the existing water heater, isolate, secured water gate valve, supply inlet/outlet in a way of works, 5] Layout, install and tap new 6" dia. underground pipes from nearest fire hydrant #13 connection, approx. 30-lf. complete with fittings and accessories. 6] Install 1-ea new DCVA backflow preventer at the fire riser for the FPS line, 7] Remove & replace existing 2-ea disconnect switch including conduit, wires, fitting, hanger, supports and all required accessories for 1-ea ACCU and 1-ea AHU, 8] Replace windows, vinyl tiles, rolled carpet, and 8] Excavation and backfilling, restoration of concrete walkway.