OUTLYING - NMC EAD PH - B543 - REPLACE ROOF
Active
FederalContract Overview
Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.
General Info
Agency
Department Of The Navy → Navfac HawaiiView Agency
NAICS
N/A
Place of Performance
H: OUT/HCKM CON, USASet-Aside
NONE
Documents
(0)AI Contract Breakdown
Uniform Contract FormatNo contract breakdown available.
Cannot generate Contract Breakdown because no documents were found from this contract's source.
Timeline
Organization & Contact Information
Show more
AgencyDepartment Of The Navy → Navfac Hawaii
ContactsNo contacts available
OfficeN/A
Office AddressN/A
ContactsNo contact information available
Full Description
Show more
Objective: Project proposed to repair/replace existing roof. Project proposed to replace the roofs of buildings Wesloc-543. Replacement of roofs includes and isn’t limited to the gutters, downspouts, soffits, fascia, flashings, on the aforementioned building. Design team to field verify by conducting an on-site inspection of the building roofs to identify conditions of the existing roofing system and related roofing components. Design shall identify the final scope based on their experience with roofing projects similar in size and scope to this project and observations made at the site visit. Roofing materials - Investigate the existing condition of the roof deck material, expansion joints, flashings, caulking, and sealants, water repellents, etc. Roof drains - Investigate the condition of all interior/exterior roof drains. Identify areas lacking positive drainage. Ensure that the drains are located properly and are sufficient in number and size to drain all accumulated water from the surface of the roof in accordance with code. Roof gutters and leaders - Perform a visual inspection to determine existing condition of materials. Ensure that the gutters and leaders are sufficient in size to drain all accumulated water from the surface of the roof in accordance with code. Design team to field verify the exact amount of work necessary on the building. Roofs may show signs of leaking, cracking. Gutters and downspouts may show signs of damage. Work to include debris removal, and roofing and gutter removal and replacement as necessary. Use all termite resistant materials for repairs. NOTE: Wo ... NOTE: description has been truncated, please see Project Note for full description.
More opportunities from Department Of The Navy → Navfac Hawaii
Same awarding agency