UM - KP 26 REBUILD AND REHABILITATE WETWELL

Active
Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

General Info

Agency

Department Of The Navy → Navfac HawaiiView Agency

NAICS

N/A

Place of Performance

USA

Set-Aside

NONE

Documents

(0)

No documents available

AI Contract Breakdown

Uniform Contract Format

No contract breakdown available.

Cannot generate Contract Breakdown because no documents were found from this contract's source.

Timeline

Posted

forecast

Ready to pursue this opportunity?

Start your free trial to track this contract, build proposals with AI assistance, and manage your pipeline.

Organization & Contact Information

Show more
AgencyDepartment Of The Navy → Navfac Hawaii
ContactsNo contacts available
OfficeN/A
Organization / Agency
Department Of The Navy → Navfac Hawaii
View Agency Profile
Office AddressN/A
ContactsNo contact information available

Full Description

Show more
*Maximo WO# GKHBRF (DESIGN)** Project scope involves 1. Overhaul pumps and piping – Replace pumps, pump motors, valves, fittings and associated piping (replace effluent piping to aboveground plug valve). This work will require a bypass of the lift station wet well structure. Bypass provisions shall provide the same performance duty point as the existing lift station with 100% pumping redundancy in accordance with 10-States Standard criterion for duplex pump configurations. KTR shall monitor and maintain the interim bypass system at all times and provide emergency response as necessary to prevent system overflows/spills. Existing lift station equipment will not be made available for the KTR’s use. Provide spare pump. 2. Reseal the interior wet well surfaces – Clean and reseal the interior surfaces of the wet well structure with approved epoxy-based commercial sealant that is specifically made for such wastewater applications. KTR shall be responsible for all associated wet well cleaning, prepping and waste disposal. Include EV sampling & testing for potential HAZMAT (lead; asbestos). 3. Electrical - Replace existing motor control center and associated electrical wiring/conduits from the meter into the station. 4. Structure Rebuild exterior structure and roof for station pumps and controls. Walls are dilapidated and needs structural repair for continued use and occupancy. 4. Prepare AM & EV project documentation -- reconcile pertinent site design details/provisions with CI DC.