Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, October 28 at 2:00 PM ET

Register Free →

This Pre-Solicitation opportunity from Department Of Defense was posted on June 24, 2024. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

Replace Air Conditioning Unit 3 at Building 23

Closed
Presolicitation_Notice_B23_ACU-3_ReplacementFederal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 238220
New
WOJC - Multi-Building Plumbing Leak Repair Project
Solicitation # WOJC – Multi-Building Plumbing Leak Repair Project
Education and Training Resources is seeking quotes for a subcontracting opportunity to perform multi-building plumbing leak repairs at the Westover Job Corps Center in Chicopee, Massachusetts. The scope of work includes replacing leaking shower P-trap drain pipes in Rooms 123 and 213, repairing a cracked drain pipe in the pipe chase of Room 216, and replacing approximately ten linear feet of leaking heat pipe in both the Administration Building and King Hall. All work must comply with the Massachusetts State Plumbing Code, International Plumbing Code, and applicable federal, state, and local regulations. Contractors are responsible for all cutting, patching, and debris removal, ensuring that all materials used are new and of commercial quality. Interested bidders must submit a detailed quote by October 30, 2026, including a comprehensive cost breakdown of labor and materials, a proposed service schedule, and a bid valid for at least 60 days. Required documentation includes a current SAM.gov UEI number, active registration, W-9, business licenses, Massachusetts plumbing credentials, and certificates of liability insurance. The project is subject to various Federal Acquisition Regulation clauses, including the Davis-Bacon Act and Service Contract Act for prevailing wages, and requires the submission of weekly certified payroll reports. Award selection is at the sole discretion of ETR and is not based solely on the lowest bid. Performance and payment bonds are required for projects exceeding 35,000 dollars, with specific requirements increasing for projects over 150,000 dollars.
Westover Job Corps Center

POSTED

about 9 hours ago

DEADLINE

in 9 days

General Info

NAICS

238220 - Plumbing, Heating, and Air-Conditioning Contractors

Place of Performance

Van Nuys, CA, 91406, USA

Set-Aside

SDVOSBC

Documents

1

Presolicitation Notice: ACU-3 Replacement at Building 23, Sepulveda ANGS

PDF, Low prioritypresolicitation
Low

AI Contract Breakdown

Uniform Contract Format

Contract not broken down yet

CLEATUS splits the solicitation into Uniform Contract Format (UCF) sections: scope, pricing, deliverables, and evaluation criteria.

Timeline

PhaseClosed
Posted

Presolicitation

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Start your free trial to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Defense → W7MX Uspfo Activity Caang 195
Contacts2 people available
OfficeBEALE AFB, CA, 95903-2180, USA
Office AddressBEALE AFB, CA, 95903-2180, USA
Contacts
Kristian Perlas
Carmen Ridener

Full Description

Show more
ACU-3 is responsible for a portion of Building 23 HVAC requirements for the 261st Cyber Operations Squadron at Sepulveda ANGS, California. Manufactured in June 2004, the unit is 20 years old. The condenser has failed, and there could be additional issues. This air conditioning unit must be replaced by trained HVAC experts equipped with the necessary tools for the job. The current ACU is a Trane Precedent, with model number YHC120A4RMA1KD1C3A2B0A606 and serial number 426100285L. For this replacement, specialized testing equipment is required to calibrate and tune certain inputs and outputs for maximum system efficiency. The replacement unit must be a 10-ton heat pump compatible with the existing BACnet Communications Interface. The installation process must adhere to the manufacturer's specifications. The new unit will be installed in the same location, using the existing power and control wiring. Following replacement, a startup and operational test must be performed to ensure the heat pump is functioning properly.

More opportunities from Department Of Defense → W7MX Uspfo Activity Caang 195

Same awarding agency

NAICS: 236220
Federal
Interior Secure Area Enclosure
Solicitation # W50S6U_27-1_SOURCES_SOUGHT_NOTICE
The 195th Wing of the California Air National Guard is conducting market research via a Sources Sought Notice to identify commercial sources for a turnkey interior secure area enclosure. The project involves the planning, design, build, delivery, installation, integration, and accreditation support of a secure space to be erected on an existing concrete slab inside a secured warehouse at the San Diego Air National Guard Station. The facility must accommodate 40 workstations, secure server and telecom rooms, administrative offices, conference spaces, and an entry mantrap. All solutions must align with the NIST definition of a Sensitive Compartmented Information Facility and adhere to ICD/ICS 705 requirements, IC Technical Specifications, and DoD facility criteria. This notice is for planning purposes only and does not constitute a solicitation or a commitment to purchase. Potential respondents are requested to provide technical solutions, representative schedules, budgetary rough-order-of-magnitude estimates, and evidence of comparable project experience. Key requirements include the ability to integrate with government-selected intrusion detection and access control systems, as well as providing methods for the government to inspect concealed work. Respondents must provide business identification including UEI and CAGE codes, and must ensure that no classified information is submitted during this market research phase.
Commercial and Institutional Building Construction

POSTED

12 days ago

DEADLINE

in 16 days
View Details

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS