Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, November 11 at 2:00 PM ET

Register Free →

This Government Contract opportunity from Department Of Veterans Affairs was posted on August 24, 2026. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

Specialized Firestopping & Joint Sealants

Closed
Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

AI Contract Overview

Show more

This subcontract opportunity with the Department of Veterans Affairs involves the installation of specialized firestopping and smoke-stopping systems at the William Jennings Bryan Dorn VAMC in Fort Wayne, Indiana. The selected contractor will be responsible for closing openings in walls, floors, and roof decks using UL-approved materials, including silicone sealants and mineral fiber filler, to ensure all penetrations and joints meet certified fire-rated standards. All work must strictly comply with ASTM E814 and ASTM E84 standards. This is a total small business set-aside under NAICS code 238390. Interested parties must submit their responses by September 10, 2026, at 3:30 PM.

General Info

Firestopping installation at Fort Wayne VAMC; small business set-aside; deadline September 10, 2026.

NAICS

238390 - Other Building Finishing Contractors

Place of Performance

Fort Wayne, IN, 46805, USA

Set-Aside

SBA

Documents

This scope was carved out of 36C25026Q0789.

The full solicitation package (19 documents), including the RFP, is on the prime solicitation, not on this scope.

View the prime solicitation

7G20--FY26 NRM - Install Analog Phone Line to Building 6 - 610A4-26-510

AI Contract Breakdown

Uniform Contract Format

No documents to break down

The breakdown needs solicitation documents. None were found from this contract's source.

Timeline

PhaseClosed
Posted

subcontract

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Veterans Affairs → 250-NETWORK Contract Office 10 (36C250)
ContactsNo contacts available
OfficeN/A
Office AddressN/A
ContactsNo contact information available

Full Description

Show more
Installs firestopping and smoke-stopping systems for prime contractors on VA projects at the William Jennings Bryan Dorn VAMC. Closes openings in walls, floors, and roof decks using UL-approved firestop materials, mineral fiber filler, and silicone sealants. Complies with ASTM E814 and ASTM E84 standards. Delivers certified fire-rated seals at all penetrations and joints.

More opportunities from Department Of Veterans Affairs → 250-NETWORK Contract Office 10 (36C250)

Same awarding agency

NAICS: 541380
New
Federal
Effluent Wastewater Testing - Saginaw VAMC
Solicitation # 36C25027Q0032
The Department of Veterans Affairs Network Contracting Office 10 is soliciting a firm fixed price contract for wastewater effluent laboratory analysis services at the Aleda E. Lutz VA Medical Center in Saginaw, Michigan. This procurement is a 100 percent set-aside for Service-Disabled Veteran-Owned Small Businesses under NAICS code 541380. The scope of work requires the contractor to provide all labor, equipment, and supervision for the preparation, collection, storage, and transportation of wastewater effluent samples, as well as the performance of analytical testing and the provision of consultative services. All analysis must comply with 40 CFR Part 136, with specific requirements for PCB testing per the City of Saginaw Total PCB Minimization Program and mercury testing per Method 245.1. Formal analytical reports must be delivered to the facility GEMS Coordinator within seven business days of sampling. To be eligible for award, offerors must demonstrate at least three years of experience in wastewater effluent laboratory testing and one year of experience in sample collection, storage, and transportation. Additionally, a signed certification regarding limitations on subcontracting is mandatory for evaluation. The contractor is required to maintain a Quality Assurance Program and adhere to OSHA safety standards, as well as the City of Saginaw Code of Ordinances and Northwest Utilities Authority regulations. Performance is scheduled to begin on December 1, 2026, with invoicing submitted semi-annually or upon completion of service. The government will monitor performance based on turnaround times, customer service responsiveness, and the accuracy of quality control results.
Testing Laboratories and Services

POSTED

about 16 hours ago

DEADLINE

in 8 days
View Details

Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS