Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, October 28 at 2:00 PM ET

Register Free →

This Solicitation opportunity from California was posted on June 3, 2025. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

Trade Package - SFO Recycled Water System Project - TP 4003 - Masonry

Closed
11431.66 - TP-4003State & Local

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 221320
New
Federal
Y--GRCA 257282 - Replace Wastewater Plant at South Ri
Solicitation # 140P2026R0101
Solicitation 140P2026R0101 is an unrestricted full and open competition Invitation for Bid issued by the National Park Service, DSC Contracting Services Division, for the replacement of the South Rim Wastewater Treatment Plant at Grand Canyon National Park, Arizona. This design-bid-build project involves the construction of a GD Membrane Bio-Reactor wastewater treatment plant, including new process systems, administrative and support buildings, and utility connections. The scope of work encompasses complete demolition and removal of existing infrastructure, site preparation, grading, paving, fencing, and improvements to the facility access road. The project also requires a 12-month operational support period following construction. The estimated magnitude of construction exceeds 100 million dollars, with a period of performance from February 1, 2027, to February 1, 2030, and a revised assumed Notice to Proceed date of April 1, 2027. The government will utilize a multi-factor, best-value tradeoff process for award, evaluating proposals based on technical experience, technical approach, management approach, key personnel experience, and price. Key personnel requirements include a Project Manager, Construction Superintendent, Quality Control Manager, Safety Specialist, and Historic Preservation Treatment Specialist. Contractors must provide performance and payment bonds and adhere to union prevailing wage rates. Technical requirements emphasize strict cybersecurity hygiene for SCADA/MES equipment, granting the government full access to software source code, and compliance with ADA standards. Invoicing is managed electronically through the U.S. Department of the Treasury's Invoice Processing Platform, requiring a draft review by the Contracting Officer's Representative seven days prior to final submission.
Dsc Contracting Services Division

POSTED

about 12 hours ago

DEADLINE

in 21 days
NAICS: 221320
Federal
Operations and Maintenance (O&M) Services for the SBIWTP
Solicitation # 191BWC26R0009
Solicitation 191BWC26R0009, issued by the International Boundary and Water Commission, seeks a contractor to provide Firm Fixed Price Operations and Maintenance (O&M) services for the South Bay International Wastewater Treatment Plant (SBIWTP) in San Ysidro, California. The contract is structured with a base year running from June 1, 2027, to May 31, 2028, and multiple option years extending through May 2031. A primary objective of the scope is managing plant operations, SCADA systems, and maintenance during the facility's expansion from 25 MGD to 50 MGD. The contractor must ensure 24/7 staffing, including a bilingual operator, and maintain strict compliance with the National Pollutant Discharge Elimination System (NPDES) permit and other regional water quality board regulations. Award will be based on the Highest Technically Rated with a Fair and Reasonable Price method, where non-price factors—such as plant operations, permit compliance, and staffing—are significantly more important than cost. Key requirements include the designation of a Project Manager, Superintendent, Site Safety and Health Officer, SCADA Specialist, and Asset Manager. The contractor is responsible for a wide array of deliverables, including a Phase-In Plan, Preventative Maintenance Plan, and monthly performance reports. Security is a high priority, requiring background investigations for personnel and adherence to NIST standards for protecting Controlled Unclassified Information. Performance will be monitored via a Quality Assurance Surveillance Plan focusing on regulatory compliance, uptime, and effluent quality.
Internat Boundary And Water Commission

POSTED

8 days ago

DEADLINE

in 2 months
NAICS: 221320
Federal
Waste Water Treatment Plant Services
Solicitation # FA448627Q0002
Solicitation FA448627Q0002 is a Request for Quotation issued by the Department of the Air Force for Waste Water Treatment Plant Services at Lajes Field in Praia da Vitoria, Azores, Portugal. The contractor will be responsible for the operation and maintenance of a waste water treatment plant with a capacity of 800,000 gallons per day, as well as the associated lift station, oil-water separator, and grease traps. Key requirements include providing a Lead Operator with a Level II or higher WPI Certification and at least three years of experience, implementing a 52-week preventive maintenance plan, and ensuring compliance with ISO/IEC 17025 laboratory standards and Portuguese decree law 183/2009 for waste landfills. The scope also encompasses corrosion control, painting, and the management of hazardous materials. The government intends to award a single Firm-Fixed-Price contract with a total duration not to exceed 66 months, consisting of a base period and four option periods. This is an unrestricted acquisition, and proposals must be submitted electronically by November 23, 2026, at 14:00 Azores Time. Offers are evaluated through a three-step sequential process: an administrative compliance review, a technical acceptability evaluation based on experience, approach, and a quality control plan, and finally a price evaluation in Euro currency. Award is contingent upon the availability of funds. Payments will be processed electronically via the Wide Area WorkFlow system.
FA4486 765 Abs Conf

POSTED

16 days ago

DEADLINE

in 27 days

AI Contract Overview

Show more

Walsh Construction Co. II, LLC has been contracted to design and build the Recycled Water Systems Project at San Francisco International Airport, which involves creating an advanced water treatment plant (AWTP) to meet regulatory standards for recycled water and PFAS removal. The project includes constructing a 250,000-gallon storage tank, pump station, and approximately three miles of pipeline connecting to airport facilities, along with upgrading three existing Sequence Batch Reactors (SBRs) and adding a new one for compliance. This is a progressive design-build effort, meaning trade work is authorized incrementally, with the goal of completing design, construction, permitting, activation, and commissioning of the new system within the existing Mel Leong Treatment Plant, which handles wastewater from various airport facilities. The specific trade package detailed focuses on masonry work, covering the construction of CMU walls in multiple buildings, including the Process Building, Control and Electrical Building, and Blower Building. Responsibilities include furnishing and installing all materials, coordinating inspections, ensuring proper alignment and safety measures, and integrating structural elements such as openings for doors and windows, embeds for steel, and rebar reinforcement. The scope emphasizes quality control through mockups and testing, with a bid deadline set for July 2, 2025. Only pre-qualified bidders can submit proposals, and the project aims for a Small Business Enterprise participation goal of 15%. The contract is part of a larger effort with a project size estimated between 50 to 100 million dollars, and interested parties can contact the designated project representative for further details.

General Info

Place of Performance

CA, USA

Set-Aside

NONE

Documents

0

No documents available

Documents will appear here when they are available.

AI Contract Breakdown

Uniform Contract Format

No documents to break down

The breakdown needs solicitation documents. None were found from this contract's source.

Timeline

PhaseClosed
Posted

Solicitation

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Start your free trial to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyCalifornia → SFO Construction
Contacts1 person available
OfficeN/A
Organization / AgencyCalifornia → SFO Construction
Office AddressN/A
Contacts

Full Description

Show more
Design-Builder Firm Name: Walsh Construction Co. II, LLC.Project Overview:The Recycled Water Systems Project will design and construct an Advanced Water Treatment Plant (AWTP) to meet Title 22 requirements for recycled water and remove per-and polyfluoroalkyl substances (PFAS) from the effluent. The project will also design and construct a 250,000-gallon storage tank, pump station, and distribution system of roughly three miles of pipeline and connections to some of the Airport's facilities. The project will also include upgrades to three existing Sequence Batch Reactors (SBR) and the construction of one new SBR for permit compliance.This is a Progressive Design-Build Project where Trade Work is incrementally authorized by Airport. The goal of this project is to design, construct, permit, activate, commission, and closeout of the new construction for the Recycled Water System Project.The new AWTP and SBR upgrade will exist in the current Mel Leong Treatment Plant (MLTP). The MLTP includes parallel treatment processes for wastewater produced from Airport facilities. The Industrial Wastewater Treatment Plant (IWTP) treats industrial wastewater and first-flush storm water runoff; and the Sanitary Wastewater Treatment Plant (SWTP) treats sanitary sewer flows.Trade Package No.: TP-4003Trade Package Title: MasonryDescription of the Trade Package Scope of Work:1.1 SCOPE OF WORKThis scope applies to the following buildings: Process Building (Building 914), Control and Electrical Building (Building 912) and Blower Building.BASE SCOPESubcontractor understands the term Include means furnish and install unless otherwise specified.Provide all labor, materials, equipment, and supervision necessary to complete the SFO Recycled Water System Project in accordance with the construction plans, project manual, and technical specifications herein.Provide and maintain vehicle and equipment access to the site during construction.The subcontractor is responsible for coordinating all inspections pertaining to contract and non-contract work (if applicable) and for scheduling inspections so as not to hinder the schedule.Subcontractor shall strictly comply with all requirements for system and utility shutdowns, and associated coordination required to maintain safety and the live operational environment.Mobilization:Assume two mobilizations: one for Building 912 and 914, and another for Blower Building.Procurement:Source and procure all necessary CMU blocks, rebar, mortar, and related materials.Ensure materials meet project specifications and quality standards.Provide submittals and shop drawings as required.Delivery and Storage:Coordinate with Walsh/ Design-Builder on delivery of materials to the site.Store materials in a secure and organized manner to prevent damage and contamination.CMU Wall Construction: Mockup of CMU wall, see spec section 04 22 00-2. Foundation and location to be provided by others.Layout and Alignment:All dimensions of CMU walls according to architectural and structural plans.Ensure proper alignment, level, and plumb of CMU blocks during installation.Installation:Install CMU blocks, ensuring proper bonding and jointing per project specifications.Control Joints to be installed per project drawings and project specificationsAll safety measures including tie offs and scaffolding are to be completed in accordance with CAL OSHA.Subcontractor to include protection to mat slab.Subcontractor to coordinate with all trades for penetrations and openings through or within CMU walls.Any blocks to be cut-to-length shall obtain Structural Engineer approval.Subcontractor to leave structures clean and prepped for any coating/painting applicationsSubcontractor to confirm color of mortar matches color of blockCMU block and mortar shall contain admixtures per specificationsBlock Out for Doors and Windows:Openings:Coordinate openings for doors and windows as per project drawings per spec section 04 22 00 Masonry.Construct temporary forms and shores.Ensure accurate dimensions and placement of openings.Furnish required engineering shoring calculations.Frames and Lintels:Coordinate installation of frames and lintels for doors and windows.Ensure proper support and alignment to maintain structural integrity.Embeds for Structural Steel:Placement:Install embeds for structural steel elements as specified in the project drawings.Coordinate placement and attachment of embeds.Coordination:Coordinate with the structural steel subcontractor to ensure compatibility and alignment of embeds with steel components.Steel Reinforcement:Rebar Installation:Furnish and install steel reinforcement (rebar) within CMU walls as per structural drawings and specifications.For the Blower Building, use similar rebar reinforcement to Process Building and Control Building.Ensure placement of rebar to conform with shop drawings.Coordinate and verify with Walsh/Design-Builder the layout of the slab on grade dowels. Dowels to be provided by others.Ensure proper spacing, alignment, and securement of rebar.Subcontractor to provide rebar shop drawings.Grouting and Joint Sealant:Grout and fill CMU cores containing rebar to provide additional strength and stability.Joint sealant and backing of control joints as required per drawings and specifications section 07 92 00 Use appropriate grouting techniques per specifications to ensure complete filling and bonding.Quality ControlMockup per specifications, test panels per specifications.Ensure Mockup is sized to display each color and type of block to be used on the project.Testing:Perform testing of materials and workmanship as required by project specifications.Document and report test results.Project CloseoutFinal Inspections:Coordinate with Walsh for third party inspections.Documentation:Provide as-built drawings and documentation.Complete any punch list items and address any remaining issues.Trade Package Bid Due Date and Time: Wednesday, July 2, 2025, by 2:00 PM PSTMain Trades of the Trade Package: MasonrySBE Participation Requirement: SBE = 15%Design-Builder requirements or prequalification criteria: Only pre-qualified bidders will be allowed to submit bids. If you did not previously pre-qualify during the pre-qualification timeframe, you will not be able to bid on this project.Contact for Trade Package information: Dominic C Fung, contact@example.gov web link to the Trade Package or more information: Please contact the email above if you were previously pre-qualified with Walsh and are interested in bidding for this trade package. Walsh will share the bid documents to pre-qualified subcontractors via email and/or BuildingConnected upon request.

Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS