This Combined Synopsis/Solicitation opportunity from Department Of Homeland Security was posted on February 26, 2026. The submission period has ended. Browse the details below for market research, or find similar active opportunities.
USCG KETCHIKAN ELECTRICAL WORK
Contract Overview
Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.
Active Opportunities Like This One
AI Contract Overview
This contract involves providing inspection, maintenance, and repair services for the electrical systems at Floating Pier One, Base Ketchikan, with particular emphasis on the shore tie terminals and the associated electrical lines. The scope includes thorough inspection and documentation of any damage or deficiencies such as corrosion or moisture intrusion in the shore tie terminals, followed by necessary repairs, drying, sealing, and functionality testing. Additionally, the electrical lines running from the Floating Pier Isolation Transfer to the shore tie terminals will be inspected and groomed to remove debris and contaminants, with Megger insulation resistance testing conducted to identify potential insulation issues or failure points. Findings and recommendations are to be thoroughly documented, including photographic evidence of all repairs done. The work is to be completed within specified timeframes: shore tie terminal work within two weeks, electrical line inspection and grooming within three weeks, and a comprehensive final report within one month from the start date. All work must conform to relevant electrical codes, safety standards, and Base Ketchikan requirements, performed by appropriately licensed and qualified personnel. The contract allows for repair materials costing up to $5,000 for the shore tie terminal boxes, and is a combined synopsis solicitation requiring email bid submissions by February 26, 2026. The designated points of contact are LT Robert Marx, CWO Russell Dever, and Senior Field Contracting Officer Deno Stamos, with the latter available for coordination of site visits.
General Info
Place of Performance
Ketchikan, AK, 99901, USASet-Aside
Timeline
Submission Closed
Organization & Contact Information
Full Description
EXTENDED PROPOSAL DUE DATE OUT TO 13 MARCH 2026 AT 3:00 PM ALASKA TIME
SEE ATTACHED SPECS/SCOPE OF WORK----
Scope of Work: Electrical Inspection and Maintenance – Floating Pier One, Base Ketchikan
1. Objective:
Provide inspection, maintenance, and repair services for electrical systems associated with Floating Pier One, Base Ketchikan, with a focus on shore tie terminals and associated electrical lines.
2. Location:
Floating Pier One, Base Ketchikan. Berth 5
3. Tasks:
A. Shore Tie Terminal Maintenance
- Inspect all shore tie terminals where vessels connect to shore power.
- Identify and document any damage, corrosion, moisture intrusion, or other deficiencies.
- Repair any identified issues to restore full functionality.
- Dry and seal all shore tie terminals to prevent future moisture intrusion.
- Test terminals for proper operation after repairs and sealing.
B. Electrical Line Inspection and Grooming
- Inspect the electrical line running from the FRC Floating Pier Isolation Transfer to the shore tie terminals.
- Clean and groom all accessible portions of the line, removing debris, corrosion, and contaminants.
- Conduct a thorough inspection for physical damage, wear, or potential failure points.
- Perform Megger (insulation resistance) testing on the electrical lines to identify any insulation breakdowns or other potential issues.
- Document all findings and provide recommendations for further action if required.
4. Deliverables:
- Written inspection report detailing findings, repairs performed, and recommendations for future maintenance.
- Documentation of Megger test results and any corrective actions taken.
- Photographic evidence of before and after conditions for all work performed.
5. Period of Performance:
- Shore Tie Terminal inspection and maintenance shall be completed within two (2) weeks from award of contract.
- Electrical line inspection, grooming, and cleaning shall be completed within three (3) weeks from award of contract.
- Final written report of findings and actions written(typed) and documented shall be submitted within one (1) month from the start of the period of performance.
6. Safety and Compliance:
- All work must comply with applicable electrical codes, safety standards, and Base Ketchikan requirements.
- All personnel must be appropriately licensed and qualified for marine electrical work.
Quote/Estimate: Quote or Estimate shall include materials going up to 5,000K for any repairs in the shore tie terminal box on the floating pier, but not to exceed.
Question: Could you quantify the shore tie terminals and cable lengths from Isolation Transfer to each Terminal to refine labor/testing time.
answer to a contractors question 1.
Good Afternoon Contracting Team,
The Shore tie Terminals is one box that has two plugs for shore ties. Approximate size is 4’x4’x2’ Not exact size of the box, but approximate.
Approximate distance of the cable/ conduit run is 550’ plus or mins 20 feet.
Area of Concern: On map, it is South Float One (Berth 5 and Berth 10).
Base Ketchikan POC: LT Robert Marx and CWO Russell Dever.
***contact Senior Field Contracting Officer (SFCO ) DENO STAMOS AT deno.a.stamos@uscg.mil if a site walk is required .
THIS IS A COMBINED SYNOPSIS SOLICIATION. RECEIPT OF BIDS VIA EMAIL IS DUE NO LATER THAN 26 FEBRUARY 2026 AT 3:00 PM ALASKA TIME ZONE,
NAICS CODE: 238210
FSC CODE:J059
More opportunities from Department Of Homeland Security → Base KETCHIKAN(00035)
Same awarding agency
Find Active Opportunities Like This
Get AI-powered intelligence on the opportunities still open
Every page of the solicitation package shredded into a compliance breakdown
AI-powered matching based on your capabilities and past performance
Competitor and incumbent history on the requirement
Automated alerts on amendments, Q&A deadlines, and award
Join 750+ contractors already using CLEATUS