Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, August 19 at 2:00 PM EDT

Register Free →

Voltage Regulator-Specific Inspection and Calibration

Active
Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

AI Contract Overview

Show more

The contract involves specialized inspection, load testing, and calibration of voltage regulators with a focus on tap changer operation and insulation integrity, requiring the use of precision electrical measurement tools to ensure operational accuracy and safety. The work demands technical expertise in electrical systems and adherence to stringent performance standards to maintain the reliability of voltage regulation equipment. The opportunity is issued as a subcontract under NAICS code 541380 by the Department of Defense through the agency W6QK Acc Anad, with a performance location in Anniston, Alabama, 36201. The solicitation was posted on August 7, 2026, and responses are due by August 28, 2026, at 9:00 PM Eastern Time. No set-aside provisions are specified, and the contract is open to qualified subcontractors meeting the technical and operational requirements outlined in the scope of work.

General Info

Specialized inspection and calibration of voltage regulators in Anniston, Alabama, due August 28, 2026.

Agency

Department Of Defense → W6QK Acc AnadView Agency

NAICS

541380 - Testing Laboratories and ServicesView NAICS

Place of Performance

Anniston, AL, 36201, USA

Set-Aside

NONE

Documents

(0)

No documents available

AI Contract Breakdown

Uniform Contract Format

No contract breakdown available.

Cannot generate Contract Breakdown because no documents were found from this contract's source.

Timeline

Posted

subcontract

Response Deadline

Submission deadline

Response Deadline

Ready to pursue this opportunity?

Start your free trial to track this contract, build proposals with AI assistance, and manage your pipeline.

Organization & Contact Information

Show more
AgencyDepartment Of Defense → W6QK Acc Anad
ContactsNo contacts available
OfficeN/A
Organization / Agency
Department Of Defense → W6QK Acc Anad
View Agency Profile
Office AddressN/A
ContactsNo contact information available

Full Description

Show more
Conduct specialized inspection, load testing, and calibration of voltage regulators, including tap changer operation and insulation integrity, using precision electrical measurement tools.

Similar Contracts

Same NAICS industry code

NAICS: 541380
New
International
Calibration and Quality Documentation ServicesThe contract entails the provision of pre-delivery calibration certificates and technical compliance documentation that must be fully traceable to international standards, ensuring the accuracy and reliability of equipment or systems prior to delivery. All deliverables are required to meet stringent quality benchmarks aligned with globally recognized metrological frameworks, supporting certification and regulatory adherence for technical goods or installations. The work falls under NAICS code 541380, indicating services related to other scientific and technical consulting, and is structured as a subcontract under the National Water Commission of Jamaica, which operates under the Government of Jamaica. The solicitation was posted on August 7, 2026, and the performance location and organizational details are not specified beyond the contracting agency's jurisdiction. There is no set-aside designation specified, suggesting the opportunity is open to qualified contractors regardless of size or status. The point of contact information is omitted, but the official portal for further details and submission is accessible via the provided link, which directs to the Government of Jamaica’s electronic procurement system. All documentation must be meticulously maintained and presented to confirm compliance without ambiguity, emphasizing precision and accountability in technical validation processes.
National Water Commission

POSTED

about 21 hours ago

DEADLINE

N/A
View Details
NAICS: 541380
New
Sewer Main Cleaning and CCTV InspectionThe contract requires high-resolution video inspection of sewer mains conducted after cleaning to evaluate pipeline condition and prepare for PACP/MACP coding, ensuring standardized assessment and documentation of structural integrity. The work is part of a larger effort to maintain and rehabilitate sewer infrastructure, with inspection data directly supporting future repair or replacement decisions based on industry-accepted condition rating protocols. All inspections must be performed with precision to capture detailed imagery suitable for accurate analysis and compliance with accepted coding standards. This is a subcontract under the SBA’s small business set-aside program, open exclusively to Small Business, Small Disadvantaged Business, Women-Owned Small Business, Veteran-Owned Small Business, Alaskan Native Corporations, Indian Tribes, and Disadvantaged Business Enterprises under the Department of Transportation. The NAICS code 541380 classifies this as environmental consulting services, and the response deadline is September 10, 2026. The contracting entity is SAK Construction, LLC, with the place of performance tied to the Memphis, Tennessee area, specifically the SARP10 Humphreys Blvd CIPP project, though exact site details are not provided. All work must align with the technical expectations for post-cleaning video assessment to ensure valid, reusable condition data.
SAK Construction, LLC

POSTED

about 22 hours ago

DEADLINE

in about 1 month
View Details

More opportunities from Department Of Defense → W6QK Acc Anad

Same awarding agency

NAICS: 424690
New
Federal
PCB-Free Transformer Oil Supply and ManagementThe contract requires the supply of new, non-reprocessed transformer oil that is free of PCBs and fully compliant with ANSI/ASTM D3487 standards, with verified concentrations under 50 ppm of polychlorinated biphenyls. The contractor must deliver the oil, manage its storage under appropriate conditions, and provide detailed batch-specific documentation confirming compliance, including certificates of analysis and chain-of-custody records. All materials must meet stringent environmental and safety specifications to ensure safe use in military equipment. The place of performance is located in Anniston, Alabama, with a zip code of 36201, indicating the oil will be delivered directly to a Department of Defense facility. This is a subcontract under NAICS code 424690, posted on August 7, 2026, with a response deadline of August 28, 2026, at 9:00 PM. The contracting agency is the Department of Defense under the office designation W6QK Acc Anad, and the solicitation is not subject to any set-aside classification. The supplier must ensure full traceability of each batch from production to delivery and maintain rigorous recordkeeping to satisfy compliance and regulatory obligations. There is no indication of subcontracting limitations or eligibility preferences, but adherence to federal procurement guidelines and environmental safety standards is mandatory.
Other Chemical and Allied Products Merchant Wholesalers

POSTED

1 day ago

DEADLINE

in 20 days
View Details
NAICS: 811310
New
Federal
Transformer Inspection and Diagnostic Testing ServicesThe contract requires comprehensive visual and electrical diagnostic services on pad-mount transformers, including critical tests such as TTR, Megger, excitation, impedance, and no-load/full-load watts analysis to assess transformer health and performance. All work must be performed by qualified personnel using industry-standard methodologies to ensure accurate data collection and reliable results. The deliverables include detailed inspection reports containing nameplate information, test findings, and clear recommendations for repair, maintenance, or retirement of each unit based on the diagnostic outcomes. The contract is a subcontract under the Department of Defense, specifically managed by W6QK Acc Anad, with performance required at Anniston, Alabama, ZIP code 36201. It was posted on August 7, 2026, and proposals are due by August 28, 2026. The NAICS code 811310 indicates the work falls under repair and maintenance services for electrical equipment. While the solicitation number and point of contact are not provided, the opportunity is open for qualified subcontractors to respond before the deadline with proposals that demonstrate technical competency, experience with transformer diagnostics, and the ability to produce compliant and actionable inspection reports.
Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance

POSTED

1 day ago

DEADLINE

in 20 days
View Details
NAICS: 811310
New
Federal
Area of Interest (AoI) – Pad Mount Transformer & Voltage Regulator Inspection and Repair (CSO-W911KF25SC002)
Solicitation # W911KF25SC002-AoI0012
ACC-ANAD is seeking qualified providers to deliver inspection and repair services for single-phase and three-phase pad-mount transformers and voltage regulators, with a focus on modern diagnostic methods to assess equipment condition accurately. Proposals must include a clear evaluation of each unit’s state, a definitive recommendation for repair or retirement, and a detailed cost estimate for all suggested repairs, ensuring informed decision-making and fiscal responsibility. The contract, if awarded, will consist of a base year and up to four optional extension years, contingent on performance and funding availability. This solicitation is issued as a CSO Area of Interest under number W911KF25SC002-AoI0012, with responses due by August 28, 2026. It is not a binding commitment or authorization to proceed; no costs incurred by offerors in developing responses will be reimbursed, and any subsequent contract will require a formal written directive from the Contracting Officer. ACC-ANAD retains the right to modify requirements and is under no obligation to issue a request for proposal or make an award. Interested parties must review the full posting on SAM.gov for submission guidelines, with all work performance centered in Anniston, Alabama, and inquiries directed to Katherine Fuller or Heather Glover.
Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance

POSTED

1 day ago

DEADLINE

in 20 days
View Details
NAICS: 811310
New
Federal
Conventional Machine Tool Repair ServicesThe contract seeks qualified vendors to provide emergency repair and maintenance services for conventional, non-CNC machine tools including lathes, milling machines, grinders, and drill presses utilized in depot operations. These services are critical to maintaining operational readiness and must be performed promptly to minimize downtime of essential equipment. The work is to be carried out at a location with zip code 36201, and the contractor is expected to respond swiftly to urgent service requests, ensuring tools are restored to full functionality with minimal disruption to military logistics and production cycles. This subcontract opportunity, classified under NAICS code 811310 for machine shop, tool die, and mold making services, is issued by the Department of Defense under the agency name W6QK Acc Anad. The solicitation was posted on August 5, 2026, and responses are due by September 1, 2026, at 10:00 PM Eastern Time. Bidders must have demonstrated expertise in servicing industrial-grade mechanical equipment and be prepared to meet strict performance timelines. While no specific set-aside status is indicated, the work is exclusively designated as a subcontract and requires proven capability in field-based, high-priority maintenance operations within a military support environment.
Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance

POSTED

3 days ago

DEADLINE

in 24 days
View Details