Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, November 11 at 2:00 PM ET

Register Free →

This Sources Sought opportunity from Department Of Veterans Affairs was posted on August 18, 2025. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

X1AA--CLIFTON PARK CBOC RENEWAL (VA-25-00079666)

Closed
36C24225Q0971Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 531120
New
Federal
Ponce Vet Center - Relocation
Solicitation # 36C24426R0012
The Department of Veterans Affairs, through the Rpo West office, is soliciting proposals for a fully serviced lease to relocate the Ponce Vet Center in Ponce, Puerto Rico. The requirement is for approximately 4,028 NUSF (4,833 ABOA / 5,438 RSF) of ADA-compliant space. The proposed lease term is 20 years, consisting of a 5-year firm period and a 15-year soft period, with the government maintaining termination rights after the firm term upon 180 days' notice. This is a total small business set-aside under NAICS code 531120. The facility must meet Facility Security Level II standards, including specific access controls and high-security locks, and must comply with seismic standards and NFPA fire and life safety codes. Key requirements include 30 on-site parking spaces, a professional sound masking system in lobbies and group rooms, and specific interior finishes and signage. Award will be based on a best value tradeoff process where technical factors—specifically the facility design, site, past performance, and experience—are significantly more important than price. Offerors must provide a detailed experience narrative limited to five relevant projects and submit past performance questionnaires directly to the Lease Contracting Officer. Proposals must include representations regarding foreign ownership for high-security space and compliance with prohibitions on certain telecommunications and video surveillance equipment. Construction activities associated with the lease are subject to Puerto Rico building construction prevailing wage determinations.
Rpo West (36C24W)

POSTED

1 day ago

DEADLINE

in 17 days
NAICS: 531120
New
Federal
US Government Seeks to Lease Office Space around Hanscom AFB
Solicitation # FA2287-27-Q-0001
The United States Air Force is conducting market research through a Sources Sought notice to identify potential providers of leased, off-base commercial office space within a 10-mile radius of Hanscom AFB, MA. The government requires a facility capable of accommodating 80 to 100 personnel, with a minimum of 11,200 and a maximum of approximately 21,000 ABOA square feet. Key facility requirements include at least one dedicated conference room of 500 square feet seating 25 people, standard commercial internet and WiFi capabilities, and available parking. The government is specifically interested in the current and potential security classification levels the space can support, ranging from Unclassified to TS/SCI and JWICS, as well as the availability of existing furniture or turnkey installation services. The anticipated lease structure consists of a one-year base period starting April 1, 2027, with four consecutive one-year option periods extending through March 31, 2032. Interested parties must submit a capability statement including property details, exact square footage, floor plans, photos, and availability dates. Submissions should also provide non-binding rental rate ranges expressed as a fully serviced gross rate per rentable square foot, detailing included utilities and estimated costs for any necessary tenant improvements. Responses are due by 3:00 PM on October 28, 2026.
FA2287 Looking Glass Next Wvg

POSTED

1 day ago

DEADLINE

in 6 days
NAICS: 531120
New
Federal
X1DB-- Katy TX OPC 175,306 ANSI/BOMA 197,219 RSF Amendment 4
Solicitation # 36C10F25R0024
Solicitation 36C10F25R0024 is a Request for Lease Proposal issued by the Department of Veterans Affairs Office of Construction and Facilities Management for a Community-Based Outpatient Clinic in Katy, Texas. The project requires a facility of 175,306 ANSI/BOMA rentable square feet (197,219 RSF) and is specifically set aside for Service-Disabled Veteran-Owned Small Businesses. The scope includes the delivery of a building shell and interior fit-out that meets rigorous medical and administrative standards, including Facility Security Level II requirements, Category 6A UTP telecommunications infrastructure, and strict energy performance certifications. Key site requirements include a minimum of 500 parking spaces and compliance with the Davis-Bacon Act for construction wages in Harris and Waller Counties. The procurement process involves a multi-volume proposal submission focusing on technical quality, delivery schedules, and past performance, with technical factors weighted approximately equal to price. Financial considerations include an estimated lump sum of 54,696,650 dollars for tenant improvements and a lease acquisition fee not to exceed 1,500,000 dollars. Following several amendments, the final proposal revisions deadline was extended to November 16, 2026. The resulting lease will be governed by GSA Template L100 and various FAR and GSAR clauses, ensuring adherence to federal standards for accessibility, fire protection, and cybersecurity.
Office Of Construction & Facilities Management (36C10F)

POSTED

1 day ago

DEADLINE

in 18 days
NAICS: 531120
New
Federal
General Services Administration (GSA) seeks to lease office space in Brunswick, GA
Solicitation # 0GA2194
The General Services Administration (GSA) Public Buildings Service is seeking proposals under solicitation 0GA2194 to lease approximately 4,485 ABOA square feet of contiguous office space on a single floor in Brunswick, Georgia. The requirement specifies a modern quality building with a permanent facade, located within a defined area bounded by Glynco Parkway, Hwy 17, 1st Street, and Hwy 341 to I-95. The lease is structured for an initial full term of 15 years, with a 10-year firm period and 90-day termination rights. Proposals are due by November 19, 2026, with an estimated occupancy date of May 1, 2027. The award will be granted to the apparent lowest priced responsive offeror. Key requirements include Facility Security Level II standards, a parking ratio of one space per 200 RSF, and proximity to a bus stop within 800 linear feet. Properties located in a 1-percent-annual-chance floodplain are generally ineligible. Financial terms include a Tenant Improvement allowance of 30.00 per ABOA SF for existing space and 53.06 per ABOA SF for other locations, with Building Specific Amortized Capital available at 12.00 per ABOA SF for new locations. Offerors must comply with FAR 52.204-24 regarding prohibited telecommunications equipment and provide an Energy Star label obtained within 12 months prior to the award date.
Pbs Office Of Leasing

POSTED

1 day ago

DEADLINE

in 21 days
NAICS: 531120
New
SLED
REQUEST FOR LEASE PROPOSALS FOR OFFICE SPACE IN HORRY COUNTY FOR THE SOUTH CAROLINA DEPARTMENT OF HEALTH AND HUMAN SERVICES
Solicitation # J020 - 120426
The State of South Carolina, through the Department of Administration Real Property Services, is soliciting lease proposals for approximately 12,000 rentable square feet of office space in Horry County, specifically within the Conway area and its surroundings. This space is intended for the South Carolina Department of Health and Human Services, with an expected occupancy date of December 2027. Proposals must be submitted by December 4, 2026, using form FMPS-202E and must include a proposed floor plan. To be eligible, property owners or agents must provide a receipt and acknowledgment of specific S.C. Code of Laws and Regulations. The selection process will be based on a cost analysis of proposals, responsiveness to requirements, and the space efficiency of the submitted floor plans. Technical specifications require that all cabling be certified to CAT-6 standards with terminations handled by the landlord. Additionally, the landlord is solely responsible for ensuring the space meets all American Disabilities Act (ADA) requirements and must bear all associated costs. All square footage calculations must adhere to the ANSI/BOMA-Z65.1-1996 standard. All inquiries and submissions should be directed to Real Property Services in Columbia, South Carolina.
Department Of Administration

POSTED

1 day ago

DEADLINE

in about 1 month
NAICS: 531120
New
SLED
AD Project #202612900 Dept of Mental Health & Dept of Developmental Services, Douglas, Grafton etc.
Solicitation # BD-27-1019-DCP06-OOL01-134771
The Division of Capital Asset Management and Maintenance for the Commonwealth of Massachusetts is seeking proposals for Client/Customer Service Office space to serve the Department of Mental Health and the Department of Developmental Services. The requirement is for approximately 6,700 square feet of usable area, though the agency will consider options between 6,000 and 7,500 square feet. Target locations are limited to Douglas, Grafton, Millbury, Northbridge, Oxford, Uxbridge, or Webster for a 10-year lease term. The facility must include specific functional areas such as reception and waiting areas, interview and hearing rooms, client restrooms, and a 100 square foot wellness room. Technical requirements include ADA compliance, AWI custom grade construction standards, and adherence to EOTSS cabling guidelines. Proposals will be evaluated based on the usable area and functionality of the space, overall financial value including base rent and operating expenses, and location suitability. Location scoring emphasizes public transportation access, with a preference for sites scoring 60 or higher on the GSA Smart Location Index, as well as parking availability and neighborhood safety. The selection process is conditional, meaning the award may depend on the landlord satisfying specific conditions established by the agency. Submissions must be made using the official DCAMM Lease Proposal form by the December 10, 2026, deadline. Landlords are required to maintain comprehensive liability insurance of at least 2,000,000 dollars and provide a Certificate of Compliance with Executive Order No. 481.
Division of Capital Asset Management and Maintenance

POSTED

2 days ago

DEADLINE

in about 1 month

General Info

NAICS

531120 - Lessors of Nonresidential Buildings (except Miniwarehouses)

Place of Performance

Clifton Park Community Based Outpatient Clinic 963 Route 146, Clifton Park, NY, 12065, USA

Set-Aside

NONE

Documents

1

Clifton Park CBOC Renewal (36C24225Q0971)

DOCX, High priority: read this first9 pages · rfq
High

AI Contract Breakdown

Uniform Contract Format

Contract not broken down yet

CLEATUS splits the solicitation into Uniform Contract Format (UCF) sections: scope, pricing, deliverables, and evaluation criteria.

Timeline

PhaseClosed
Response Deadline

Deadline has passed

Posted

Sources Sought

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Veterans Affairs → 242-NETWORK Contract Office 02 (36C242)
Contacts1 person available
OfficeALBANY, NY, 12208, USA
Office AddressALBANY, NY, 12208, USA
Contacts
Michael MorrisContracting Officer

Full Description

Show more
CONSTRUCTION TASK Provide all necessary work for the upfit of the space leased for the Clifton Park Community Based Outpatient Clinic (CBOC) in Clifton Park, New York. A. Background Information: The Albany VA Medical Center in Albany, NY is seeking to renew and expand an existing lease of approximately 5,000 nets usable square feet to located at 963 Route 146, Clifton Park, NY 12065. The clinic will contain Primary Care, outpatient Mental Health, Telehealth specialty services, laboratory, Hemo infusion therapy, Physical Therapy, and Occupational Therapy services. The space will be upfitted to meet the Community Base Outpatient Clinic design guidance per attached layout drawing and scope of work. B. Project Intent: Provide the Clifton Park CBOC with space that fully supports efficient patient care operation and that allows the clinic to meet its projected workload. C. This project includes all design services required to upfit the expanded square footage as required per attached Clifton Park CBOC Architectural Scope of Work including security provisions dated April 24, 2025, and Clifton Park CBOC Drawing A1 & A2 dated May 15, 2025, for the expanded lease space, including all utilities, to meet the VA s needs and the requirements of this document. D. Weekly meetings and site visits will be conducted with the property owner and VA staff to address any questions and monitor progress of the project scope of work. These meetings will include review of the layout plan, scope of work, detailed discussions of the various project elements. Discussions will also include design constraints, access requirements and all applicable codes and standards. II. Design Requirements A. Property owner is responsible to hire a licensed designer / professional to ensure all mechanical, plumbing, fire protection, HVAC, and electrical codes are maintained due to upfit modifications/changes. B. Licensed designer / professional shall provide all necessary engineering and design services to ensure the entire space maintains appropriate HVAC systems. The property owner is responsible for making all necessary HVAC modifications to maintain all spaces at 70 degrees year-round. In addition, the property owner is responsible for making all necessary HVAC modifications necessary to maintain 30%-60% relative humidity in all seasons with four air exchanges per hour. C. Licensed designer / professional shall provide all necessary engineering and design services to ensure the entire space maintains appropriate plumbing systems. The property owner is responsible for making all necessary modifications to ensure domestic water temperature is no greater than 110F. D. Licensed designer / professional shall provide a phasing plan that minimizes impacts on patient care and workflow. Always maintaining a dedicated women s exam room. E. Licensed designer / professional shall provide all necessary construction documents required to ensure all work is completed in accordance with the attached scope of work and layout drawings. III. Upfit Requirements A. The attached Clifton Park CBOC Architectural Scope of Work including security provisions dated April 24, 2025, and Clifton Park CBOC Drawing A1 & A2 dated May 15, 2025, provide complete requirements for the necessary upfit modification to expand the Clifton Park CBOC. STRATTON VA MEDICAL CENTER Clifton Park COMMUNITY BASED OUTPATIENT CLINIC April 24, 2025 Clifton Park CBOC Architectural Scope of Work This document provides a detailed description of all the improvements needed to be completed by December 2025. The property owner is responsible for all necessary work. ARCHITECTURAL General Notes Entire space includes complete painting of all walls, doors and trim. Patch and paint all the walls depending on the level of removal and damage with renovation/move. Remove all items hung previously (subject to being replaced). Ensure entire space includes fully functional and operational lights. Damaged lighting fixtures need to be replaced. Accommodate required electrical and data outlets according to floor plan and equipment layouts. New electrical/data outlets must be added within 3 feet of all equipment shown on drawing A1 & A2. All new data runs shall be CAT6a. Remove carpet in all locations, install resilient tile or LVT with new wall base. All metal blinds to be removed and cleaned. Damaged blinds to be replaced. Blinds missing operating wand to be repaired. Ceiling tiles to be changed out where showing damage or staining. At existing millwork, where there is no modification, clean and repair all surfaces and drawer slides as required. Install new consistent signage on new leased side and as required or missing in existing space. All existing resilient flooring to be stripped and waxed prior to moving in. Existing Leased Side NO WORK in the following rooms: 204 Toilet 207 Provider 208 Exam 210 Toilet 212 Lab 213 Exam 4 216 Pharmacy Office 217 Exam 5 218 Provider 2 219 Storage 221 RN Care Manager 223 Exam 6 227 BVAC Office 231 Toilet 233 Biohazard Work to be completed in the following rooms (reference drawing A1 & A2): 201 Existing Waiting Room to become staff break room/conference. Add window film for privacy at elevator core. 203 Exam 1 Eliminate to become passageway. Install wall with 36 wide door. Add storage closet with Shelves and (1) swing door. 205 Alcove to become Tech RN. Install necessary electrical and data for workstation. 206 RN Care Mgr. Office to become Exam 1. Remove/rebuild the east wall to become large exam. Add millwork with sink and upper cabinet. Patch flooring as required. 209 Exam 3 to become Tele-Retinal Room, block existing window with GWB to eliminate all light. 211 Existing Tele-Retinal Exam to become Meds Room. Add millwork with sink and upper cabinet. 214 Scale & Pyxis Alcove to become 2 workstation desks. Install necessary electrical and data for workstation. 222 Reception to become 4 Shared LPN work room. Remove entry door and existing millwork/sliding -glass. Install full height wall at south with 36 door to breakroom, assess lighting, electric and data. 226 Shared Work Room to become Exam 6. Install wall to divide space (Left side Exam & Right-side Provider 3). Add millwork with sink and upper cabinet. Move existing side door, add 36 door to south wall. 228 Existing Break Room to become Provider 4. Remove existing millwork. Add 36 door at opening. 229 Existing Conference Room to become Infusion. Add millwork with sink and upper cabinet. Build (2) small closets for regulation storage items. 232 Existing IT Closet to remain. New Additional Leased Space (reference drawings A1&A2) 240 Becomes New Waiting Room. Remove half wall L partition. 241 General Notes Scope 242 General Notes Scope, lower transaction counter, to comply with ADA height (30-inch) restrictions at check in location at waiting room side (reference drawing A-2), reinstall taller glass at modified countertop. 243/244 Dividing wall between offices to be removed to create large exam. In 243 remove millwork, keep millwork in 244, patch and repair all surfaces as required (floor/walls/ceiling) 245 General Notes Scope, add millwork and sink as shown on plan. 246 General Notes Scope 247 General Notes Scope. Increase size of room to become ADA accessible, see plan A2 for dimensions. 248 General Notes Scope, remove sink, counter all wall items. 249 General Notes Scope 250 General Notes Scope 251 General Notes Scope, remove all existing millwork. Install a new countertop with sink and upper cabinet, prepare the left side wall for new doorway into a new toilet room. 252 General Notes Scope, create ADA toilet room from existing space. Install toilet, sink, grab bars and all associated hygiene dispensers 253 General Notes Scope 254 General Notes Scope, reduce size of room to create pass-thru corridor from existing lease side. Lighting to be modified to new area. 255 General Notes Scope OIT General Notes A reconfiguration of IT infrastructure to meet the requirements of the CBOC upfit to include: - Install VA Wi-Fi as part of CBOC expansion. - Expand network range to encompass additional space. Expand network switch capacity to meet new requirements. - Reconfigure available TIPS to meet the requirements of new/reconfigured spaces. Obtain and install additional IT hardware to provide the required connectivity. - Work with COR and NetOps for organizing extensions/numbers for telephone needs. - Work with HTM and NetOps to configure network settings for additional equipment. - All new data lines are to be CAT6a. SECURITY PROVISIONS The objective of this requirement is to provide the appropriate level of physical security that will, when constructed and implemented, providing the appropriate level of physical security to support the services provided by this clinic. The intent is to protect the safety of the patients, staff and visitors in case of an emergency or incident by the use of physical measures. Measures designed to safeguard people, to prevent unauthorized access to equipment, facilities, material and documents, and to safeguard against damage and loss. The installation, maintenance, monitorship and responsibility for notifying local police of clinic alarm activation should be accomplished through a contractual arrangement with a commercial security firm. The installation shall be incorporated into the Tenant Improvements and the maintenance and monitorship shall be incorporated into the monthly payments. SECURITY SYSTEM: Provide a motion intrusion detection system for the entire VA space that is monitored by motion sensors and contacts on exterior doors and windows, and also a door contact on the IT Room door. The system shall meet the following requirements but not limited to: (1) An internal, automatically charging DC standby power supply and a primary AC power operation. (2) An automatic reset capability following and intrusion detection. (3) A local alarm level of 81dB (min.) to 90 dB (max.) within the configuration of the protected area. (4) A low nuisance alarm susceptibility. Shall not exceed a rate of one (1) alarm per seven days within the first 60 days after installation and acceptance. Sensor adjustments will be made and then not to exceed one (1) alarm per 30 days. (5) Annunciators/keypads shall be located at all entrances and shall have the capability of identifying protected zones. (6) No access permitted from the patient corridor into the Common Work Area. If passage is required in an emergency, the door needs to be equipped with electronic hardware, magnetic locks & connected to the fire alarm system. It shall also have a PIV to allow a staff member to go from the patient corridor into the Common Work Area. (7) Locks shall be Best Lock with removable core cylinders that are removable only with a special key or tool without disassembly of the knob or lockset. Cylinders shall be 6 or 7 pin. The finish shall be 630 stainless steel with antimicrobial coating. (8) System shall have the capability of transmitting alarms to an off-site 24 hr. monitoring company and VA police service. (9) Telecommunications Room: Room must have motion detection and camera inside the room and intrusion detection on the door. (10) Motion detectors shall be installed in the Waiting Area, Conference Room, Corridor (as needed pending the configuration). SPECIAL SECURITY REQUIREMENTS: The VA Police will conduct vulnerability assessments over the course of the lease term to determine vulnerabilities in physical security and provide recommended corrective actions. The clinic shall use a 2-control level system of master, individual and special keys. Lessor shall provide 2 copies of the master, each individual and each special key including 6 blanks for each key provided. The VA is responsible for establishing a keying plan. Keys produced shall not bear identifying marks, such as VA and/or US Government . The loss of theft of VA space keys by non-VA personnel shall be reported as soon as notified to the VA Police/Nurse Manager. If the VA police investigation does not immediately result in the recovery of the key, or a positive determination is made that the loss occurred off facility property, the key cores operable by the lost key will be changed and all affected keys replaced with five days at Lessor s expense. Persons found to be in unauthorized possession of VA keys, or in possession of unauthorized reproduction of such keys, shall be cited by VA Police for the appropriate violation of Title CFR 1.218. Medicine closets shall have a drywall ceiling. Walls and ceilings shall be constructed with a woven mesh, 1.2mm (.047 in.) wire diameter alloy #304 stainless steel, with tensile strength of 29 kg/mm (1,600 lbs./sq. in.) PANIC ALARM SYSTEM: Lessor shall furnish and install one (1) panic alarm system. The system should have a wireless Panic Alarm device in all the exam rooms, reception area, consultation room, conference room and the blood draw room. The panic alarm indicator light to be installed above the patient care room doors and will transmit to the Common Work Area, Reception Area and the local police. ROOM CONDITION INDICATOR LIGHT SYSTEM: An in-use indicator light system to be installed for each exam room providing a visual indication of the activity in the patient care room. The patient may use the system to indicate that he/she has completed gown/ungowning and staff can enter the room. The system shall also inform staff working outside of the room which staff member is currently in the room with the patient. The color of light illuminated identifies either the Provider, Nurse, Health Technician or other staff is with the patient. SITE ENTRANCES: Lighting must be provided at site entrances to provide illumination in support wayfinding, security and safety needs by assisting pedestrians and vehicles to locate their destinations expeditiously.

More opportunities from Department Of Veterans Affairs → 242-NETWORK Contract Office 02 (36C242)

Same awarding agency

Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS