Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, November 11 at 2:00 PM ET

Register Free →

Y1DA-- NRM-CONST 630A4-17-433 Replace Boiler Plant Main Electrical Switchgear

Awarded
36C24226B0042Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

AI Contract Overview

Show more

The contract is for the replacement of the Boiler Plant Main Electrical Switchgear at the VA New York Harbor Healthcare System - St Albans Campus under solicitation number 36C24226B0042, with a response deadline of May 26, 2026. It is a Firm-Fixed-Price construction contract with a 730-calendar-day performance period, and all work must be performed at the specified site. The solicitation requires bidders to account for hazardous materials abatement via an open line item allowance, ensuring all offerors are evaluated under the same financial assumption since the full scope of asbestos or other regulated materials is unknown and has not been surveyed. Contractors must include allowances for all necessary environmental investigations, sampling, testing, and abatement activities in compliance with federal and local regulations. The contract mandates strict adherence to safety and quality protocols, including the implementation of a Contract Quality Control Plan aligned with FAR 52.246.12, submission of safety and health documentation, and compliance with OSHA 10- and 30-hour training requirements for all personnel, with a required Site Safety and Health Officer possessing documented experience and certification. Subcontracting is limited under 38 U.S.C. § 8127(k)(2), requiring the prime contractor to perform at least 15% of the work with its own forces, and prohibits payments to non-VA VIP-listed subcontractors from exceeding 85% of the total contract value, with certification of compliance mandatory. The procurement is designated as a 100% Service-Disabled Veteran-Owned Small Business (SDVOSB) set-aside, requiring all offerors to be certified as such in SAM with an active Unique Entity ID. All proposals must be submitted electronically via email by the deadline, with no physical submissions accepted, and must include the SF 1442 form, bid bond, Buy American Certificate, and subcontracting compliance certification. The contract incorporates numerous FAR and VAAR clauses governing payment, changes, inspection, warranties, and compliance, including requirements for VA-approved laboratories, environmental safety, equipment labeling with engraved brass or rigid plastic nameplates, and adherence to NFPA 70 and other applicable codes. Payment is processed exclusively through the VA’s Electronic Invoice Presentment and Payment (EIPP) system using X12 EDI format, with final acceptance conducted on-site by the Government’s authorized representative after verification of all systems and compliance with technical, safety,

General Info

Replace main electrical switchgear and transformers for VA boiler plant with hazardous material handling.

Contract Value

$2,166,666

NAICS

238210 - Electrical Contractors and Other Wiring Installation Contractors

Place of Performance

NY

Set-Aside

SDVOSBC

Award Issued Date

Documents

22

36C24226B0042 Amendment 0003

DOCX, High priority: read this firstamendment
High

52.225-2 Buy American Certificate (Oct 2022)

DOCX, High priority: read this first2 pages · certification
High

Amendment 0001 to Solicitation 36C24226B0042

DOCX, High priority: read this first6 pages · amendment
High

Amendment 0002 to Solicitation 36C24226B0042 - Hazardous Materials Survey Clarification

DOCX, High priority: read this first2 pages · amendment
High

IFB 36C24226B0042 Bid Pricing Sheet

DOCX, High priority: read this first3 pages · ifb
High

IFB 630A4-17-433 Replace Boiler Plant Main Electrical Switchgear

DOCX, High priority: read this firstifb
High

Limitation on Subcontracting Certification

DOCX, High priority: read this first2 pages · certification
High

NY20260001 - Wage Determination for Heavy Dredging (New York)

PDF, High priority: read this firstwage-determination
High

NY20260003 General Decision - Wage Determination

PDF, High priority: read this firstwage-determination
High

Participation Goals for Minorities and Females - Federal Construction

PDF, High priority: read this first32 pages · sow
High

Pre-Solicitation Notice 36C24226B0042 Replace Boiler Plant Main Electrical Switchgear

DOCX, High priority: read this firstpresolicitation
High

S02 Autodesk Contractors Access Instructions 1.1

PDF, High priority: read this first9 pages · access-instructions
High

Safety and Environmental Record Certification

DOCX, High priority: read this first1 page · certification
High

Solicitation 36C24226B0042 - Replace Boiler Plant Main Electrical Switchgear

DOCX, High priority: read this first44 pages · ifb
High

SOW Replace Boiler Plant Main Electrical Switchgear R1

DOCX, High priority: read this first3 pages · sow
High

VA Master Specifications for Switchgear Replacement Project 630A4-17-433

PDF, High priority: read this first573 pages · specifications
High

VA New York Harbor Boiler Plant Main Electrical Switchgear Replacement Project

DOCX, High priority: read this first3 pages · rfp
High

VA Privacy Training for Personnel without Access to VA Computer Systems 1.1

PDF, High priority: read this first4 pages · training-document
High

Award 36C24227C0018 - Replace Boiler Plant Main Electrical Switchgear

DOCX, Low priorityaward
Low

FAR Deviation Notice February 2025

DOCX, Low priority1 page · special-notice
Low

Project 630A4-17-433 Site Walk-Thru Sign-in Sheet

PDF, Low priorityother
Low

S02 IFC VA Stamped Drawings SA Switchgear Replacement 630A17433 11152023

PDF, Low priority15 pages · other
Low

AI Contract Breakdown

Uniform Contract Format

Sign up to view the full breakdown with detailed analysis of each section.

Timeline

3 updates
PhaseAwarded
Posted

Presolicitation

Type Changed

Presolicitation → Solicitation

Notice updated

Response deadline changed from May 14, 2026 to May 26, 2026. The notice description changed.

Notice updated

The notice description changed.

Notice updated

The notice description changed.

Awarded

Contract was awarded

Ready to pursue this opportunity?

Get full access to track this contract, build proposals with AI assistance, and manage your pipeline.

Organization & Contact Information

Show more
AgencyDepartment Of Veterans Affairs → 242-NETWORK Contract Office 02 (36C242)
Contacts1 person available
OfficeALBANY, NY, 12208, USA
Office AddressALBANY, NY, 12208, USA
Contacts
Vladimir S StoyanovContracting Officer

Full Description

Show more
36C24226B0042 Amendment 1 630A4-17-433 Replace Boiler Plant Main Electrical Switchgear 36C24226B0042 Amendment 1 630A4-17-433 Replace Boiler Plant Main Electrical Switchgear 36C24226B0042 Amendment 1 630A4-17-433 Replace Boiler Plant Main Electrical Switchgear Please confirm the correct Davis-Bacon wage determination. The solicitation currently includes a New York 'Heavy Dredging' wage determination, which appears unrelated to this building electrical project. VA CO: See attachment Please clarify whether bidders are pricing Base Bid only, or Base Bid plus Alternate No. 1. If Alternate No. 1 remains, provide a clear bid schedule. VA COR: Base Bid only Please confirm whether this is strictly design-bid-build. The solicitation references 100% IFC drawings, but the SOW also states the contractor is responsible for the 'design' of replacement systems. VA COR: It s considered design-bid-build. Please provide complete existing equipment data for substations, transformers, MCCs, ATSs, breakers, and feeders (manufacturer, ratings, dimensions, weights, available fault current, trip settings, etc.). VA COR: VA has limited information from its database. GC to conduct full investigation and field verification before work. Please confirm whether existing transformers contain PCBs and provide testing documentation. If unknown, confirm whether an allowance will be issued for hazardous disposal. VA COR: AE shall confirm if the survey was done based on the initial contract. If not, please include service(s) during CPS. Please define allowable outage windows for each shutdown/load transfer, including permitted days, times, duration limits, and blackout periods. VA COR: COR to communicate with St. Albans M&O for shutdown coordination. GC to provide phasing plans and area of work. Please confirm whether shutdowns must occur after hours/weekends and whether premium labor should be included in bids. VA COR: utility shutdown can be performed during normal business hours, depending on location and time. OFF hours work can be established when affecting facility s normal operation. Please identify who is responsible for utility switching/LOTO of the 5kV system (VA staff, utility provider, contractor, or third party). VA COR: Applies to all. Work can be coordinated in between parties, depending on work area and needs. Please confirm whether new short-circuit, coordination, and arc flash studies are required and whether existing studies are available VA COR: Yes, it is required since the contractor shall install a complete new equipment AE shall confirm as well. 18. Please provide hazardous materials survey information for asbestos, lead paint, refrigerants, contaminated oil, and other regulated materials in demolition areas. VA COR: Hazardous sampling and abatement are required. GC to provide abatement service, A/E to provide Air Monitoring service. 20. Please confirm all required permits (NYC DOB, FDNY, utility, environmental, crane permits, etc.) and identify whether the contractor or VA is responsible for obtaining them VA COR: GC is responsible for work permits. VAMC is a federal facility, however, certain city permit is required i.e.. Asbestos abatement, Fire suppression system related, crane safety .etc. Please provide complete existing equipment data for substations, transformers, MCCs, ATSs, breakers, and feeders (manufacturer, ratings, dimensions, weights, available fault current, trip settings, etc.) VA COR: duplicate of question No. 5 Please confirm whether existing transformers contain PCBs and provide testing documentation. If unknown, confirm whether an allowance will be issued for hazardous disposal. VA COR: duplicate of question No. 6 Please define allowable outage windows for each shutdown/load transfer, including permitted days, times, duration limits, and blackout periods. VA COR: duplicate of question No. 7 Please confirm whether shutdowns must occur after hours/weekends and whether premium labor should be included in bids. VA COR: duplicate of question No. 8 28. Please provide temporary power requirements including capacities, connection points, conductor routing, grounding requirements, and acceptable temporary equipment locations. VA COR: proposed action plan or phasing plan is required before any coordination with the VA. Please identify who is responsible for utility switching/LOTO of the 5kV system (VA staff, utility provider, contractor, or third party) VA COR: duplicate of question No. 13 Please confirm whether new short-circuit, coordination, and arc flash studies are required and whether existing studies are available. VA COR: duplicate of question No. 14 Please provide hazardous materials survey information for asbestos, lead paint, refrigerants, contaminated oil, and other regulated materials in demolition areas VA COR: duplicate of question No. 18 Please identify rigging/logistics constraints including access routes, crane requirements, loading limitations, door openings, and staging areas for large electrical equipment replacement. VA COR: staging areas is available. GC to conduct field investigations and condition verification for proper work requirements. COR to establish communication in between parties. Please confirm all required permits (NYC DOB, FDNY, utility, environmental, crane permits, etc.) and identify whether the contractor or VA is responsible for obtaining them VA COR: duplicate of question No. 20 Spec section General Requirements page no.2 states ALTERNATE NO.1: BASE BID except minus 2nd switchgear unit. But the Bid pricing sheet does not have any alternate listed. If there is any alternate work, then please modify the bid pricing sheet accordingly VA COR: Base bid only. 43. Spec section 01 90 00 has General Commissioning Requirements. Please confirm the Commissioning agent will be hired by VA. VA COR: A/E to cover or responsible for Commissioning service on behalf of the VA. The time limit to complete this project is 730 calendar days. Why is the agency anticipating such a long time for completion? VA COR: extended timeline to cover, equipment lead-time/ delivery / contracting and paperwork process in terms of any new proposed work. The work of demolition of concrete pads, construction of new concrete pads and switchgear replacement is on the lower level. Please advise if there is access at the exterior street from this lower level to haul the construction materials in and out. VA COR: Multiple exits and stairway are available. Please confirm work hours are regular M-F 8:00 am to 4:30 pm VA COR: All work shall be performed under normal business hours, unless otherwise, special circumstances and specific timeline applies. Is the 5KV wiring being replaced from the substations back to the manhole 2A? VA COR: No, the 5kV wiring is being replaced from the substation back to the splice enclosure inside the same electrical room. Where are the starting and the ending points for the feeder s replacement? VA COR: In accordance with drawings ED-101 and ED-601, the 5KV feeders extending from the splice enclosure to the transformer are to be replaced both located inside the electrical room. Also, see drawing cut below for clarification. Is the walkthrough sign sheet available? VA COR-Yes. Will be attached to the Amendment. Will the concrete bases for substations 1 and 2 need to be replaced, or can they be reused? VA COR- No, due to differences in dimensions and positioning for the new equipment, the existing pad must be removed and replaced with a new one. Also, conditions and capacities of existing concrete pads are unknown. 52.What is the distance from the substations to the splice point for the 5KV medium voltage wire? VA COR-: Refer to drawing ED-101 enlarged plan D6. Both the substation and the splice enclosure are located within the electrical room. Will aluminum conductors be allowed or only copper conductors? VA COR: Aluminum conductors and materials are strictly prohibited. Refer to the VA specifications and construction manual for compliance requirements, use copper only. How many floor mounted transformers are being replaced? 54.1. D2X/Ramboll - Refer to drawing ED-101 and ED-601. Two 300KVA transformers, two load interrupter switches and two motor control centers are being replaced. Can the transformers being replaced be mounted in the air? VA COR: No, the new transformer is a 300kVA transformer and needs to be floor mounted. Specifications call for the installation of a chain link fence around the construction area. Is this in addition to the dust barrier? VA COR: Yes. Chain link fence is in addition to the dust barrier. Will the duct barrier require venting to the outside of the facility? 57.1. 5/5/26-VA agreed item 9 Will the duct barrier require venting to the outside of the facility? Should read Will the Dust barrier require venting to the outside of the facility? VA COR: Venting/exhaust to the exterior is not specifically required for the Class II dust-control barrier shown, unless required by the Contractor s approved dust control plan, VA Infection Control, or if work conditions require negative-pressure containment. If exhaust is used, the Contractor must verify that construction exhaust is not reintroduced into the medical center through intakes or openings, and HEPA filtration is required where exhaust dust may reenter the facility. This needs approval by the COR. Will the facility hoist be allowed to be used to lower equipment to the lower level of the facility? VA COR: No. What is the required height of the Dust Barrier in the work zone? VA COR: For the Class II precautions identified on GI-003, provide dust-control barriers as shown and as required by Section 01 35 26. Where a full containment barrier is required or directed by VA Infection Control/COR, the barrier shall extend from floor to ceiling with seams sealed to prevent dust migration. Final barrier limits and door locations shall be coordinated in the field with and approved by the VA COR.

Similar Contracts

Same NAICS industry code

NAICS: 238210
New
26-140 Installation of Emergency Shut Off Switches
Solicitation # 26-140
Solicitation 26-140 is a subcontracting opportunity with Atterbury Job Corps Center and Adams & Associates for the installation of emergency shut-off switches on equipment in Edinburgh, Indiana. The scope of work focuses on addressing safety deficiencies for rotating equipment in the Facility Engineering Storage and Glazing/Welding/Heavy Mechanics shops. Requirements include the installation of mushroom-head push-button switches and 60A shunt-trip branch circuit panels in both areas, ensuring a manual reset is required following power failures. All work must comply with OSHA, EPA, and Indiana state and local codes, with a one-year guarantee on workmanship and manufacturer products. The contract will be awarded based on best value, with evaluation weighted toward price (60 points), quality (20 points), past performance (10 points), and schedule (10 points). Bidders must submit a single lump sum proposal on company letterhead, including a detailed cost breakdown, a timeline for completion, and proof of a valid Indiana Contractor's License. Mandatory requirements include attendance at the site pre-bid walk-through and the provision of a 90-day bid guarantee. Administrative requirements include Net 30 payment terms, compliance with Davis-Bacon Act wage rates, and the submission of SF 1413 and certified payroll records prior to final payment. This opportunity is set aside for various small business categories, including VOSB, SDVOSB, WOSB, and HUBZone certified firms.
Atterbury Job Corps. – Adams & Associates

POSTED

about 2 hours ago

DEADLINE

in 22 days
View Details
NAICS: 238210
New
26-138 Main grounding electrode conductor is not provided
Solicitation # 26-138
Solicitation 26-138 is a request for a licensed electrical contractor to inspect and correct grounding system deficiencies at the Atterbury Job Corps Center in Edinburgh, Indiana. The primary scope of work involves establishing an effective ground-fault current return path by connecting main grounding electrode conductors from incoming water pipes to service distribution panels. Specific requirements include installing a new #4AWG conductor from the water main to the 200A service panelboard in the Staff Lounge, providing two supplemental 5/8 inch by 8 foot grounding electrodes connected via #6AWG bare copper conductor, and ensuring all work conforms to NEC 2020, 250, as well as current EPA and OSHA regulations. The contract is a small business set-aside and will be awarded based on best value, with evaluation weights assigned to price (60 points), quality (20 points), past performance (10 points), and schedule (10 points). Bidders must submit a single lump sum proposal including a detailed cost breakdown, a timeline for substantial completion, a 90-day bid guarantee, and certification of compliance with Davis Bacon Act wage rates. Mandatory requirements for submission include a valid Indiana Contractor's License, a completed W9, and attendance at the mandatory pre-bid site visit. The contractor must also provide proof of automobile liability and workers compensation insurance, naming Adams and Associates, Inc. as an additional insured. Payment terms are set at Net 30.
Atterbury Job Corps. – Adams & Associates

POSTED

about 2 hours ago

DEADLINE

in 22 days
View Details
NAICS: 238210
New
Transformer Oil Testing Services
Solicitation # RFP-VC-26-010
The Inland Empire Utilities Agency is soliciting proposals under RFP-VC-26-010 for professional transformer oil testing services to enhance the reliability, safety, and maintainability of its transformers. The scope of work is divided into three primary areas: conducting visual and infrared thermographic inspections on energized transformers to identify thermal anomalies, installing standardized external oil sampling devices for safer collection, and performing detailed oil testing analysis. Additionally, the selected contractor must evaluate existing nitrogen blanket systems to ensure positive pressure and provide on-site training for up to 20 agency staff members on inspection methods and defect identification. All work must adhere to strict industry standards, including NETA MTS, IEEE, NFPA 70E, and ASTM D923, with infrared inspections performed by ASNT Level 1 certified technicians or higher. The agency intends to make a single award to the most capable offeror based on their past performance, staffing plan, personnel availability, and cost-effectiveness. Qualified proposers must have completed at least two similar projects within the last five years, including at least one for a utility or industrial facility. Proposals must be submitted electronically via PlanetBids by December 23, 2026, and must include a detailed project approach, company profile, and required certifications such as a Non-Collusion Statement and Workers Compensation Certificate. The resulting contract will utilize fixed pricing with a not-to-exceed limit, and payments will be processed electronically via ACH within 30 days of invoice approval by the Project Manager.
Inland Empire Utilities Agency

POSTED

about 2 hours ago

DEADLINE

in about 2 months
View Details
NAICS: 238210
New
Centennial JCC Emergency Lighting Replacement, Upgrade, Testing & Maintenance Services
Solicitation # centennial-jcc-emergency-lighting-replacement-upgrade-testing-maintenance-services
Management and Training Corporation is soliciting bids for a fixed-price, single lump sum contract to provide emergency lighting replacement, upgrade, testing, and maintenance services at the Centennial Job Corps Center in Nampa, Idaho. The project involves the inspection, testing, repair, and certification of emergency lighting systems to ensure compliance with NFPA 101 (2024 Edition) and NFPA 70 standards. The selected electrical contractor will be responsible for inventorying all fixtures, performing functional power-cut tests, applying durable tracking labels, and integrating recurring maintenance into the facility's Computerized Maintenance Management System. The estimated contract value ranges from $25,000 to $100,000, with a performance period of 30 business days following the written Notice to Proceed. Bids are due by December 1, 2026, and must be submitted via email to Sandra Clore. A mandatory physical site visit and signature on the attendance roster are required prior to bid submission. For bids equal to or greater than $25,000, contractors must provide a bid bond guarantee of 20% of the base bid, as well as performance and payment bonds from a surety company with at least an A- rating. The award will be based on overall best value. This opportunity is set aside for small businesses, including VOSB, SDVOSB, WOSB, and HUBZone certified entities. The contract mandates strict adherence to federal labor and safety regulations, including the Davis-Bacon Act, Service Contract Labor Standards, and Executive Order 14026 regarding minimum wages. Contractors must provide paid sick leave per EO 13706 and display required bilingual employee rights and wage determination notices. Compliance with various FAR clauses is required, including those regarding the Buy American Act, whistleblower rights, and the prevention of trafficking in persons. Final acceptance and payment are contingent upon a substantial completion inspection and the resolution of a final punch list.
Management & Training Corporation/Centennial Job Corps Center

POSTED

about 2 hours ago

DEADLINE

in about 1 month
View Details

More opportunities from Department Of Veterans Affairs → 242-NETWORK Contract Office 02 (36C242)

Same awarding agency

NAICS: 238210
New
Federal
Y1DA--Project620-22-110 Replace and Upgrade Fire alarm System at Montrose VAMC
Solicitation # 36C24227B0009
Solicitation Number 36C24227B0009 is a 100 percent Service Disabled Veteran-Owned Small Business (SDVOSB) set-aside for the Department of Veterans Affairs. The project involves a multi-phased campus-wide replacement and upgrade of the fire alarm system at the FDR VA Medical Center, Montrose Campus in New York. The contractor will replace the existing, unreliable Edwards system with a 2026 Honeywell Notifier Fire alarm system featuring intelligent addressable technology. This new system must meet all NFPA codes and guidelines, providing capabilities such as sensitivity reporting, maintenance notifications, and control functions for HVAC fan shutdowns, elevator controls, and the releasing of locked doors. The magnitude of construction for this project is estimated between 2,000,000.00 and 5,000,000.00 dollars, falling under NAICS Code 238210 with a size standard of 19 million dollars. The period of performance is 550 calendar days from the Notice to Proceed. Eligible bidders must be registered in SAM.gov and Duns and Bradstreet, and verified as an SDVOSB through the SBA certification portal. All submissions must be emailed by the deadline of December 16, 2026, at 10 AM Eastern Time, as hand-carried bids will not be accepted. This project also requires bonding.
Electrical Contractors and Other Wiring Installation Contractors

POSTED

about 9 hours ago

DEADLINE

in about 2 months
View Details
NAICS: 541350
New
Federal
H399--36C242-27-AP-0524| 528-27-1-6893-0009 Elevator Inspections, Base (4) Canandaigua VA Medical Center (VAMC) & Bath VA Medical Center (VAMC)
Solicitation # 36C24227Q0041
The Department of Veterans Affairs, Network Contracting Office 2, is soliciting quotes for third-party elevator inspection services at the Canandaigua and Bath VA Medical Centers in New York. This SDVOSB set-aside contract requires a Qualification of Elevator Inspectors (QEI)-Certified Inspector to witness and document semi-annual safety inspections, annual pressure and no-load tests, and five-year full-load tests. All work must comply with the most current editions of ASME A17.1 and ANSI/ASME 17.2 standards. Results must be documented using VA Form 10-6166, and the contractor is responsible for verifying that maintenance check charts are current and correctly annotated. The period of performance consists of a base year running from November 1, 2026, to October 31, 2027, with four subsequent 12-month option years, with services typically performed in April and October. Award decisions will be based on technical capability, past performance, and price, with the government reserving the right to use a trade-off process for additional benefits. Offerors must submit a technical capability statement of no more than 10 pages and a statement of acceptance regarding the solicitation terms and conditions by October 29, 2026. The contract incorporates various FAR and VA clauses, including specific requirements for electronic payment, personnel vetting, and supplemental insurance.
Building Inspection Services

POSTED

about 9 hours ago

DEADLINE

in about 21 hours
View Details
NAICS: 325120
New
Federal
6835--VISN 2 Prosthetics Downstate Home Oxygen Services
Solicitation # 36C24226R0081
Solicitation 36C24226R0081 is a request for proposals issued by the Department of Veterans Affairs, Samuel S. Stratton VA Medical Center, for Home Oxygen Services to benefit veterans within the VISN 2 Downstate New York Healthcare Network, including the Bronx, Hudson Valley, New Jersey, New York Harbor, and Northport areas. This Service-Disabled Veteran-Owned Small Business set-aside contract covers a base period from January 1, 2027, through December 31, 2027, with five subsequent option periods extending through June 30, 2032. The scope of work includes the rental and maintenance of oxygen concentrators, liquid oxygen systems, and ventilators, as well as the provision of Registered Respiratory Therapist visits and the mandatory use of thermal fuses for safety. The estimated contract value ranges from a minimum of 100,000 dollars to a maximum of 40 million dollars. Award decisions will be based on a best value trade-off process where non-price factors, including technical capability, past performance, and SDVOSB/VOSB status, are significantly more important than cost. Technical evaluations focus on Joint Commission accreditation, 24/7 service capabilities with a four-hour response time, and a transition plan requiring full implementation within 180 calendar days of award. Contractor performance will be systematically monitored through a Quality Assurance Surveillance Plan involving patient satisfaction surveys, random audits of equipment installation, and monthly inventory reviews. Proposals must be submitted electronically in PDF format to Contract Specialist Corey Swinton by the final deadline of February 10, 2027.
Industrial Gas Manufacturing

POSTED

about 9 hours ago

DEADLINE

in 3 months
View Details
NAICS: 811210
New
Federal
J065--FY27 Services Base+4 | Stryker Neptune Prevent ProCare Service | 528A8 Albany Stratton
Solicitation # 36C24227Q0099
The Department of Veterans Affairs, Network Contracting Office 2, intends to award a sole-source, firm-fixed-price purchase order to Stryker Sales, LLC for the Stryker Neptune Prevent ProCare Service at the Samuel S. Stratton Department of Veterans Affairs Medical Center in Albany, New York. This award is justified as Stryker Sales, LLC is the only authorized service provider for the equipment, a fact supported by a proprietary letter from the manufacturer and subsequent market research. The scope of work involves the maintenance and repair of 10 Neptune units, specifically five Neptune 3 Rovers, three Neptune S Rovers, and two Neptune Smart Dockers. Comprehensive services include preventive maintenance inspections and documentation, parts and labor for normal-use wear and damage, scheduled maintenance travel, priority repair service, equipment-use training, and loaner equipment subject to availability. This procurement is classified under NAICS 811210 for Electronic and Precision Equipment Repair and Maintenance, which carries a small business size standard of 34 million dollars, and PSC J065. While this is a notice of intent to sole source rather than a request for competitive quotes, interested firms capable of meeting the requirements may submit written responses and supporting documentation to Contract Specialist Zachary Whiting by October 30, 2026, at 10:00 AM EST. Telephone inquiries are prohibited, and the government will proceed with the sole-source award to Stryker Sales, LLC if no qualified alternative responses are received.
Electronic and Precision Equipment Repair and Maintenance

POSTED

about 9 hours ago

DEADLINE

in 1 day
View Details
NAICS: 236220
New
Federal
Building 13 Stair and Roof Replacement at Castle Point VAMC
Solicitation # 36C24227B0002
Solicitation 36C24227B0002 is a firm-fixed-price construction project for the Department of Veterans Affairs to repair exterior architectural features of Building 13 at the Castle Point VA Medical Center in New York. The scope of work includes brick replacement, tuckpointing, and the complete removal and installation of roofing systems, including low-slope metal and shingled areas. Additional requirements involve structural stair reconstruction, asbestos remediation of tar vapor barriers, and lawn restoration. The project has a construction magnitude between $500,000 and $1,000,000 and a performance period of 180 calendar days from the Notice to Proceed, which includes 30 days for closeout. This procurement is a 100% set-aside for Service-Disabled Veteran-Owned Small Businesses (SDVOSB) under NAICS code 236220. Bids must be submitted electronically to the Contracting Officer by November 10, 2026, at 10:00 AM EDT. Required submission documents include a bid bond, a Buy American Certificate, and a Limitations on Subcontracting Certificate. Because the facility operates 24/7, the contractor must provide a detailed work plan including an Infection Control Risk Assessment and interim life safety measures. Personnel are subject to strict vetting and credentialing processes, including fingerprinting and identity verification, before beginning work on site.
Commercial and Institutional Building Construction

POSTED

about 9 hours ago

DEADLINE

in 13 days
View Details

Ready to Pursue This Opportunity?

Get AI-powered intelligence on this solicitation and the ones like it

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS