Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, August 19 at 2:00 PM EDT

Register Free →

2025-26 CUP CDP IS Bulk Liquified Natural Gas Storage and Hydrogen Fueling Station

Active
State & Local

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

General Info

Agency

California → National City

NAICS

237120 - Oil and Gas Pipeline and Related Structures ConstructionView NAICS

Place of Performance

Bay Marina Drive & West 19th St, National City, CA, 91950

Set-Aside

NONE

Documents

(4)

Notice of Completion for 2025-26 CUP CDP Bulk Liquefied Propane Gas Storage and Hydrogen Fueling Station

PDFnotice-of-completion

CEQA Initial Study Checklist for 2100 Haffley Avenue Project

PDFceqa-checklist

NOI for Environmental Review and Comment Period for 2100 Haffley Avenue Project

PDFnotice-of-intent

SCH Summary Form for 2025-26 CUP CDP Bulk Liquefied Propane Gas Storage and Hydrogen Fueling Station

PDFenvironmental-summary

AI Contract Breakdown

Uniform Contract Format

Sign up to view the full breakdown with detailed analysis of each section.

Timeline

Posted

forecast

Ready to pursue this opportunity?

Start your free trial to track this contract, build proposals with AI assistance, and manage your pipeline.

Organization & Contact Information

Show more
AgencyCalifornia → National City
Contacts2 people available
OfficeN/A
Organization / Agency
California → National City
Office AddressN/A
Contacts
Sophia DepewAssistant Planner
Martin ReederActing Director of Community Development

Full Description

Show more
The applicant (WestAir) is proposing the development and operation of a multi-use retail gas supplier providing hydrogen fueling station for heavy-duty commercial vehicles, propane bulk storage and dispensing operations, industrial gas retail sales and warehousing, and administrative offices for customer service and distribution operations. The business will located at 2100 Haffley Avenue which is in the Medium Manufacturing zone and Coastal Zone. The property is an 88,880 square-foot industrial site, with an existing 24,000 square-foot warehouse building. The remaining area is a paved outdoor loading yard. A total of 14 employees will work at the site, with varying shifts to support the fueling station and business operations. The business will operate during regular business hours, with the exception of the hydrogen fueling station which will operate 24 hours a day, seven days per week as an automated system for preapproved commercial fleet vehicles. The site currently has two entrances located off of Haffley Avenue. One leads directly to employee/customer parking, while the second entrance provides access directly to yard area. Development of the site includes the addition of an above ground 30,000-gallon horizontal propane tank with associated dispensing equipment and a hydrogen fueling station that includes 6,500 kg of liquid hydrogen storage. The fueling station can be accessed by up to two vehicles at a time. There is no proposal for a canopy over the station or other traditional fueling station characteristics. Hydrogen will be delivered via WestAir’s liquid hydrogen transport vehicles. Liquid hydrogen will be sourced from Los Angeles facilities and transported directly to the on-site storage system as a closed loop system Propane will be delivered via commercial propane transport trucks from regional suppliers and transported directly to the on-site 30,000 gallon storage tank. During the full operational phase, the business is projecting 1,000 kg of hydrogen per day to serve WestAir’s internal fleet vehicles and contracted external fleets. Propane will be dispensed for retail customers, filling five gallon to twenty-five gallon tanks as needed for customers. Due to the hazardous nature of the materials, an Emergency Response Plan (ERP) will be developed and implemented, as well as a Fire Protection Plan, prepared by a fire protection engineer to address the hazardous materials on site. The Medium Manufacturing zone requires a Conditional Use Permit for bulk liquified petroleum gas storage and the hydrogen fueling station. The Initial study has been prepared for those portions of the project only.

Similar Contracts

Same NAICS industry code

NAICS: 237120
New
Federal
Coos Bay Fuel Upgrades
Solicitation # W9127N26QA118
The U.S. Army Corps of Engineers, Portland District, is soliciting quotes under solicitation number W9127N26QA118 for the removal and replacement of existing bilge oil piping and a 550-gallon used oil tank at the Coos Bay Pier, 1460 N Bayshore Drive, Coos Bay, Oregon. The work, to be performed between October 1, 2026, and March 30, 2027, includes replacing approximately 275 feet of bilge oil piping and 300 feet of used oil piping along with associated valves, couplings, elbows, and supports, upgrading to a new 550-gallon double-walled above-ground storage tank certified to UL 142 with marine-grade coating, leak detection, emergency shutdown valves, and seismic anchoring, and elevating the new tank one foot above the existing concrete pad while reusing the foundation. All materials must meet ASTM A312, ASME B36.19M, and ASME B16.11 standards, and piping must be permanently marked in compliance with MIL-STD-161H and ASME A13.1 for color coding and identification. Installation must be followed by hydrostatic and pneumatic testing with zero pressure drop and zero visible leakage, certified by the contractor’s QC manager and an independent inspector, and all required documentation including daily reports and operations manuals must be submitted for government acceptance. The contract is a firm fixed price, set aside entirely for small businesses under NAICS code 237120, and includes strict subcontracting limits requiring the prime contractor to perform at least 50% of the labor and material. All offerors must be registered in SAM.gov with a valid UEI and comply with FAR and DFARS clauses covering small business eligibility, prohibitions on inverted domestic corporations, safeguarding covered defense information, whistleblower rights, and restrictions on acquiring covered telecommunications equipment. Personnel must pass NCIC-III and TSDB background checks, complete Anti-Terrorism Level I and Suspicious Activity Reporting training via JKO, and submit pre-screened employee lists using E-Verify prior to site access, with non-U.S. citizens requiring 30-day advance notification and HQUSACE authorization. Invoices are to be submitted as PDFs via email to the Contracting Officer’s Representative, and site visits are optional but encouraged, with registration required by August
W071 Endist Portland

POSTED

1 day ago

DEADLINE

in 4 days
View Details
NAICS: 237120
New
Federal
Repair Natural Gas Phase 1 and Phase 2 Base Wide, Vance AFB, OK
Solicitation # XTLF-21-1031
This solicitation, identified as XTLF-21-1031, is a combined synopsis and solicitation for commercial services under FAR 12.6 and FAR Part 13, requesting firm-fixed-price proposals to repair natural gas infrastructure across Phase 1 and Phase 2 at Vance Air Force Base in Enid, Oklahoma. The total estimated contract value ranges from $1,000,000 to $5,000,000, with funds not currently available and no award to be made until federal funding is secured. The Government retains the right to cancel the solicitation at any time without obligation to reimburse offerors for costs incurred. Proposals must be submitted electronically to Betty Kliewer by August 25, 2026, at 11:00 AM CST, and must remain valid for 180 days after the closing date. Award will be made on a Low Price/Technically Acceptable basis, requiring offerors to submit completed Bid Forms PA, PB, and Combine, along with detailed technical specifications, a line-item labor and material cost breakdown, and qualifications demonstrating relevant experience, certifications, and capability. All contractors must have an active, non-expired registration in the System for Award Management (SAM) to be eligible. A mandatory site visit is scheduled for July 28, 2026, at 10:00 AM CST, with attendees required to report to the Visitor Center at Building F72 at least 45 to 60 minutes prior, present valid government-recognized identification (REAL ID or U.S. Passport), and provide proof of vehicle registration and insurance to gain base access. All attendees must adhere to Vance AFB entry and conduct regulations. The contractor is responsible for furnishing all personnel, equipment, materials, and services per the attached Repair Natural Gas Specifications, which incorporate compliance with ASTM, ASME, API, OSHA, EPA, and MIL-STD-101 standards. Requirements include proper identification marking of aboveground and buried piping per color-coded and legend standards, use of brass tags for small-diameter lines, and yellow warning tape for buried lines. The contractor must maintain a qualified Project Superintendent and Site Safety and Health Officer on-site at all times, with alternates available, and ensure adherence to EM 385-1-1 safety protocols, Buy American Act compliance, permit acquisition for hazardous activities, and submission of comprehensive deliverables including as-built drawings,
FA3029 71 Ftw Cvc

POSTED

1 day ago

DEADLINE

in 18 days
View Details
NAICS: 237120
New
SLED
161105 Pipe Bore and Jack Service
Solicitation # IFB-124811
The Virginia Department of Transportation is soliciting bids for pipe rehabilitation services using jack and bore methods within Grayson County, Virginia, under solicitation number IFB-124811. The contract falls under NAICS code 237120 and is targeted at contractors capable of performing underground pipeline rehabilitation without extensive excavation. Interested parties must submit responses by August 17, 2026, at 3:00 PM Eastern Time, with the solicitation posted on August 6, 2026. The work is to be performed in Grayson County and is part of VDOT's infrastructure maintenance efforts to upgrade aging utility and drainage systems. All proposals must meet technical and compliance requirements specified in the solicitation materials accessible via the provided vendor portal link. The point of contact for questions and clarifications is Paul Jones, reachable by phone at 276-696-3341 or email at johnp.jones@vdot.virginia.gov. There is no set-aside classification indicated for this solicitation, meaning it is open to all eligible businesses, including small and large contractors. The contract is managed through VDOT’s Wytheville Residency office, and performance must comply with state and federal standards for public works projects. Bidders are expected to provide detailed methodologies, equipment specifications, safety plans, and timelines for completing the jack and bore operations at designated sites across the county. All awarded contracts will be subject to standard VDOT procurement regulations and contractual obligations surrounding quality, schedule adherence, and site restoration.
Virginia Department of Transportation

POSTED

1 day ago

DEADLINE

in 10 days
View Details
NAICS: 237120
New
Federal
W.H. Ford RTC Kentucky Fueling System Repairs
Solicitation # W9128F26SS005
The W.H. Ford RTC Kentucky Fueling System Repairs solicitation, identified by number W9128F26SS005 and posted on August 4, 2026, seeks information from potential contractors regarding a comprehensive range of repairs and upgrades to a fueling facility. The scope includes repairing concrete on dispenser and offload islands, draining water from communications handholes, installing an EFSO station, mounting leak detector probes, and laying new asphalt circulation pavement. Additional work involves replacing canopy coatings, installing splash blocks, and renewing roof penetration boot seals for all tank vent pipes. The contract also requires the replacement of aboveground fuel pipeline coatings, installation of a deadman for truck loading, and provision of coated bolts, studs, and washers. Upgrades to tank systems include replacing tank vents, repairing and enhancing grounding systems, installing grounding for tank stairs, and modifying and extending existing platforms to ensure safe access to all tank appurtenances. Furthermore, the ATG console and its modules are to be upgraded. All work must be performed at the specified location with an unknown precise address but identified ZIP code 42345. This is a sources sought notice, indicating the government is gathering market information rather than soliciting formal bids, with responses due by August 19, 2026. Point of contact for inquiries is Steven Engen of the U.S. Army Corps of Engineers, Office of Endist Omaha in Nebraska.
W071 Endist Omaha

POSTED

3 days ago

DEADLINE

in 12 days
View Details
NAICS: 237120
New
Federal
Repair Above Ground Storage Tanks, USCG Base Elizabeth City
Solicitation # 70Z08126QELIZ0021
The Contractor is required to supply all supervision, labor, equipment, parts, and tools necessary to repair deficiencies in above-ground storage tanks at USCG Base Elizabeth City, North Carolina, as detailed in the attached Scope of Work. This solicitation is exclusively set aside for Small Businesses under NAICS code 237120 with a size standard of $45,000,000, and the Government plans to award a Firm-Fixed Price contract. Quotes must be submitted via email to Frank.M.Powers@uscg.mil no later than noon Eastern Time on August 28, 2026, with the SF 1442 form fully completed from blocks 14 through 20c, including the UEI. All inquiries must be submitted in writing by noon on August 20, 2026, and no oral questions will be considered; potential amendments may be issued to clarify ambiguities. Prospective bidders are strongly urged to conduct a site visit to verify quantities and conditions ahead of submission. A scheduled site visit will occur on August 18 at 0900, and advance arrangements must be made at least three days prior with Josh Carr at steven.j.carr@uscg.mil. All visitors must complete a visitor access request form, present a valid Real ID or passport, and provide their full name, date of birth, and the last four digits of their Social Security Number; holders of valid Military ID or RAPIDGate pass are exempt from the form requirement.
Base Elizabeth CITY(00081)

POSTED

3 days ago

DEADLINE

in 21 days
View Details