99--Denison Powerhouse AC replacement, Lake Texoma, Texas

Awarded
W912BV11R0049Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 333415
New
Federal
NSWCCD York Chill Pump Replacement
Solicitation # N0016727Q1002
The Naval Surface Warfare Center, Carderock Division (NSWCCD) is soliciting quotes for the procurement, delivery, and turn-key installation of a replacement pump (Pump No. 1) for York Chiller No. 1 in Building 157. This equipment is critical for providing chilled-water cooling to the Building 13 Server Rooms. The project requires the removal of the damaged pump and the installation of a York Chill Pump, Model YLAA0080SJ46X, Serial SEMM-609950. Due to the proprietary nature of the equipment, the contractor must utilize certified Johnson Controls technicians or representatives. The installation must be completed on or before December 18, 2026, at the NSWCCD facility in Bethesda, Maryland. This is a brand-name restricted procurement under full and open competition and is not set aside for small businesses. The government intends to award a single firm-fixed-price purchase order based on the lowest price technically acceptable method, evaluating quotations on a pass/fail basis for technical requirements and considering past performance via the Supplier Performance Risk System. All quotes must be submitted on official company letterhead, including all-inclusive pricing and business size, and sent via email to the contract specialist and contracting officer by 09:00 AM EDT on November 06, 2026. The contract includes specific requirements for item unique identification per MIL-STD-130 and electronic invoicing through the Wide Area WorkFlow system.
Nswc Carderock

POSTED

about 14 hours ago

DEADLINE

in 17 days

General Info

Contract Value

$30,973

NAICS

333415 - Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment Manufacturing

Place of Performance

OK

Set-Aside

NONE

Award Issued Date

Documents

0

No documents available

Documents will appear here when they are available.

AI Contract Breakdown

Uniform Contract Format

No documents to break down

The breakdown needs solicitation documents. None were found from this contract's source.

Timeline

PhaseAwarded
Posted

Combined Synopsis

Awarded

Contract was awarded

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Defense → W076 Endist Tulsa
ContactsNo contacts available
OfficeTULSA, OK, 74137-4290, USA
Office AddressTULSA, OK, 74137-4290, USA
ContactsNo contact information available

Full Description

Show more
This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in Subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; proposals are being requested and a written solicitation will not be issued. Replace with newly manufactured material of latest technology (no used or outdated material)One 10 Ton AC System with 3 phase electrical system at nominal 480 volt. Single phase systems will not be accepted. Performance levels for the new system shall meet or exceed the performance levels of the existing Lennox CB17-135V-3, HS29-120-2G system. All copper tubing, coils, and devices containing Freon are required to be coated with Technicoat 10-2 Coil Coating. The condenser unit shall be sized to fit on the existing elevated platform with sufficient room for servicing. No aluminum coils or tubing are allowed, all copper construction is required. All interconnecting tubing between condenser and evaporator unit. All interconnecting wiring between condenser and evaporator unit and thermostat. The thermostat. A simple electronic thermostat is needed, nothing programmable. All duct as needed to transition from the new evaporator unit to existing duct.

More opportunities from Department Of Defense → W076 Endist Tulsa

Same awarding agency

NAICS: 237990
New
Federal
Webbers Falls Excitation System Replacements
Solicitation # W912BV26RA029
Solicitation W912BV26RA029 is a Request for Proposal issued by the Department of Defense, specifically the US Army Corps of Engineers Tulsa District, for the design and installation of three excitation systems at the Webbers Falls Powerhouse in Oklahoma. The project scope includes the demolition of existing equipment and the supply of three identical full inverting potential source rectifier exciters, each featuring a rectifier assembly, a power potential transformer, and microprocessor digital controllers capable of operating in high humidity and temperatures up to 40 degrees Celsius. Key deliverables include the hardware, comprehensive O&M data packages, field test reports, spare parts, and training for maintenance personnel. The performance period is 300 calendar days from the date of the notice to proceed. This is a partial small business set-aside under NAICS code 237990. Proposals are evaluated on an acceptable or unacceptable basis across three factors: past performance (requiring experience in specific categories within the last five years), a detailed work plan and schedule, and minimum small business participation percentages, including 16 percent aggregate and 11 percent for small disadvantaged businesses. The contract requires strict adherence to electrical and safety standards such as NFPA 70 and IEEE C2, as well as military standards for shipment and storage. Additionally, the prime contractor must possess a Facility Clearance, and personnel must comply with DoD 8570.01-M training and cybersecurity requirements. Payment requests are to be processed electronically via Wide Area WorkFlow.
Other Heavy and Civil Engineering Construction

POSTED

about 14 hours ago

DEADLINE

in 7 days
View Details

Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS