65--640-CA3-379 Correct Life Safety Deficiencies, Lobby Sunnyvale

Closed
36C26119Q0835Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 238290
New
Centennial JCC Panic Hardware Services (Electrical Room Egress Doors)
Solicitation # Panic Hardware (Electrical Room Egress Doors)
Management & Training Corporation is soliciting bids for the installation of panic hardware on electrical room egress doors at the Centennial Job Corps Center in Nampa, Idaho. The project requires the contractor to perform site surveys, procure heavy-duty Grade I commercial-grade panic bars, exterior trim, rim cylinders, strikes, and door closers, and complete the installation across five specific locations: the B-Cafeteria, CM-Men’s Dorm, CW-Women’s Dorm, D-Recreation, and F-Vocational areas. All work must adhere to NEC 2023 Article 110.26(C)(3), NFPA 101 Life Safety Code, and ADA standards. To ensure fail-safe operation, the contractor must perform at least 10 consecutive cycle tests per installation. This is a fee-for-service subcontracting opportunity set aside for small businesses, including VOSB, SDVOSB, WOSB, and HUBZone certifications. Bidders must possess Idaho state licensure and meet specific insurance minimums. Required submission documents include a completed bid sheet, a supplier packet with a W-9 and self-certification form, three references for similar projects, and applicable SBA certification letters. Bids must be submitted via email to Sandra Clore by December 1, 2026, at 3:00pm MST. The contract is subject to various Federal Acquisition Regulations, including prevailing wage rates under Executive Orders 14026 and 13658, and requires a Unique Entity Identification number for reporting purposes.
Management & Training Corporation/Centennial Job Corps Center

POSTED

42 minutes ago

DEADLINE

in about 1 month
NAICS: 238290
New
SLED
SMDOT Elevator Maintenance
Solicitation # 12701633
The City of Santa Monica, through the D600 Department of Transportation (SaMoDOT), is soliciting proposals for turnkey maintenance, inspection, and repair services for three hydraulic elevators located at 1620 6th Street. The equipment includes one Independent model AAK137, one Montgomery model AA2986, and one Otis model AEP227. The selected contractor must provide monthly systemic maintenance, a dedicated maintenance supervisor for safety surveys, and 24/7 emergency callback services with a one-hour response time. All parts must be new, conform to Original Equipment Manufacturer standards, and be stocked in a local warehouse. The award will be granted to the best bidder based on a variety of factors, including the technical experience of key personnel, financial resources, and the ability to provide future service, rather than solely on the lowest price. Bidders must comply with Title II of the ADA, the Living Wage Ordinance, and Labor Code Section 1773.2 regarding prevailing wages. A payment bond is required for awards exceeding 25,000 dollars, and the City requires a certificate of insurance naming them as an additional insured. Proposals must be submitted electronically via the OpenGov portal by November 9, 2026, at 3:00pm. The contract includes a ten-day written notice period for termination without cause and requires notification of force majeure events within 24 hours.
D600 DEPT OF TRANSPORTATION - SaMoDOT

POSTED

1 day ago

DEADLINE

in 13 days
NAICS: 238290
New
SLED
RFP 902787 Elevator Condition Assessment & Modernization Plan
Solicitation # 902787
The Alameda County General Services Agency Building Maintenance Department is soliciting proposals for a turnkey professional services contract to perform comprehensive condition assessments and develop modernization plans for elevator equipment at three Oakland, California locations: 1106 Madison Street, 1111 Jackson Street, and 1401 Lakeside Drive. The project encompasses a total of nine elevators, including Otis hydroelectric and overhead traction models, as well as US Elevator overhead traction units. The scope of work is divided into six phases, beginning with baseline scheduling and condition assessment reports, moving through the preparation of bid-ready modernization specifications and procurement support, and concluding with construction oversight and warranty period inspections. Qualified consulting firms must demonstrate at least five years of relevant experience, and staff performing the work must hold a current National Association of Elevator Safety Authorities International Qualified Elevator Inspector certification. As a public works project, all contractors must be registered with the California Department of Industrial Relations and adhere to prevailing wage and apprenticeship requirements. Proposals will be evaluated based on a maximum of 550 points, with a heavy emphasis on the description of proposed services and relevant experience over cost. Preference may be given to certified Small and Local Emerging Businesses. The awarded contractor will be ineligible to bid on any subsequent solicitations resulting from this assessment.
General Services Agency-Procurement

POSTED

1 day ago

DEADLINE

in 21 days
NAICS: 238290
New
SLED
80626B0051-Elevator Repair 308 West 150 St, MN
Solicitation # 80626B0051
Solicitation E-PIN 80626B0051 is a competitive sealed bid issued by the New York City Department of Housing Preservation and Development for the complete repair of the elevator at 308 West 150th Street, Manhattan. The scope of work includes the replacement of the controller, pump unit, traveling cables, and car interior, with potential replacement of the piston and jack. Additionally, the contractor must provide a one-month maintenance contract including video phone monitoring and ensure all work meets New York City Building Code, ASME A17.1 standards, and passes Department of Buildings acceptance and Category 1 tests. The contract will be awarded to the lowest responsive and responsible bidder, with submissions required electronically via the PASSPort portal. As a project funded by the U.S. Department of Housing and Urban Development under the Community Development Block Grant Program, the contract is subject to strict federal and local compliance requirements. These include adherence to the Build America, Buy America Act, federal accessibility standards such as the Americans with Disabilities Act, and mandatory prevailing wage rates for laborers and mechanics. Contractors must comply with Executive Order 11246 regarding equal employment opportunity and provide necessary insurance and indemnification. Bid bonds are not required for proposals under 250,000 dollars, and payments are subject to the availability of program funds and prompt payment provisions of the Procurement Policy Board Rules.
Department Of Housing Preservation And Development

POSTED

2 days ago

DEADLINE

in 27 minutes

AI Contract Overview

Show more

The Department of Veterans Affairs is conducting market research through a Sources Sought Notice to identify qualified contractors for project 640 CA3-379. The objective is to correct life safety deficiencies and complete the commissioning of the lobby in Building 1002 at 1080 Innovation Way in Sunnyvale, California. This effort is categorized under NAICS code 238290 and is intended as a Service-Disabled Veteran-Owned Small Business set-aside. The scope of work is divided into four primary areas: exterior improvements, first-floor modifications, second-floor updates, and overall system commissioning. Exterior tasks include installing a chain link fence, correcting ramp slopes, adding handrails, and sealcoating and striping the parking lot. Interior work involves installing motion-detector automatic door openers, replacing fire exit doors with ADA-compliant hardware, applying fire-stop sealants in electrical and elevator rooms, and upgrading communication room wall panels and cabling. The commissioning phase requires a certified agent to test and certify elevators, fire protection systems, and HVAC equipment. The anticipated construction period is 120 calendar days.

General Info

VA seeks SDVOSB for life safety repairs and commissioning in Sunnyvale, California.

NAICS

238290 - Other Building Equipment Contractors

Place of Performance

Department of Veterans Affairs;VETERANS AFFAIRS SUNNYVALE CAMPUS;Sunnyvale - Buliding 1002;1080 Innovation Way;Sunnyvale, CA 94, CA

Set-Aside

SDVOSBC

Documents

0

No documents available

Documents will appear here when they are available.

AI Contract Breakdown

Uniform Contract Format

No documents to break down

The breakdown needs solicitation documents. None were found from this contract's source.

Timeline

PhaseClosed
Posted

Sources Sought

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Start your free trial to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Veterans Affairs → 261-NETWORK Contract Office 21 (36C261)
ContactsNo contacts available
OfficeMATHER, CA, 95655, USA
Office AddressMATHER, CA, 95655, USA
ContactsNo contact information available

Full Description

Show more
Page 10 of 10 THIS IS A SOURCES SOUGHT NOTICE Subject: Sources Sought, Project: 640 CA3-379 Correct Life Safety Deficiencies in the Lobby of Building 1002 at 1080 Innovation Way Sunnyvale California, Department of Veterans Affairs, Veterans Health Administration (VHA) VISN 21. The Government does not intend to award a contract on the basis of this Sources Sought Notice or to otherwise pay for the information solicited. Although proposal, offeror, contractor, and offeror may be used in this sources sought notice, any response will be treated as information only. It shall not be used as a proposal. The purpose of this sources sought is to conduct market research to support the procurement of construction services to Correct Life Safety Deficiencies in the Lobby of Building 1002 at 1080 Innovation Way Sunnyvale California. This notice serves to survey the market in an attempt to ascertain whether or not sources are capable of providing the requested services. This notice allows potential contractors/vendors to submit a non-binding statement of interest and documentation demonstrating their capability. The sources sought effort is intended to assess industry capabilities and develop/support the intended direction of acquisition planning. The Network Contracting Office (NCO 21) is requesting responses from qualified business concerns; the qualifying NAICS code for this effort is 238290 Other Building Equipment Contractors This sources sought notice is to gain knowledge of potential qualified sources and their size classifications (Service Disabled/Veteran Owned Small Business (SDVOSB/VOSB), Hub zone, 8(a), small, small disadvantaged, woman owned small business, or large business) relative to NAICS 238290. Responses to this notice, will be used by the Government to make appropriate acquisition decisions. After review of the responses to this notice, a solicitation announcement may be published. Responses to this notice are not considered adequate responses to any corresponding solicitation announcement. All interested offerors will have to respond to the solicitation announcement in addition to responding to this notice. Any information received from a contractor in response to this Sources Sought Notice may be used in creating a solicitation. Any information received which is marked with a statement, such as proprietary or confidential, intended to restrict distribution will not be distributed outside of the Government, except as required by law. Background: The Department of Veterans Affairs is seeking vendors who can provide construction services to Correct Life Safety Deficiencies in the Lobby of Building 1002 at 1080 Innovation Way Sunnyvale California Scope of Work. The vendors must demonstrate the ability to meet all requirements for this notice. See Scope of Work and additional attachments for all the details. INSTRUCTIONS: Submit a brief description, two-three (2-3) pages (including cover letter) that demonstrates how your company can provide the requested services that are required in the attached draft salient characteristics. Include past experience in providing this service to the VA, other Government (Federal or State) agency, or for a private facility. Please specify your availability and your address. The attached Scope of Work NOT finalized. If any portions seem unclear, prohibited, and/or you are unsure about the draft descriptions of the requirement please list your comments and/or concerns in your response so they can be addressed. Provide BUSINESS SIZE AND SOCIO-ECONOMIC STATUS; (a) Indicate whether your business is large or small. (b) If small, indicate if your firm qualifies as a small, emerging business, or small disadvantages business. (c) If disadvantages, specify under which disadvantaged group and if your firm is certified under Section 8(a) of the Small Business Act. (d) Indicate if your firm is a certified Service-Disabled Veteran Owned Small Business (SDVOSB) or Veteran Owned Small Business (VOSB). (e) Include the DUNS number of your firm. (f) State whether your firm is registered with the System for Award Management (SAM) at http://www.sam.gov and/or the VetBiz Registry at http://vip.vetbiz.gov. If not, please NOTE that any future solicitation could only be awarded to a contractor who is registered in SAM and to receive award based on VOSB or SDVOSB status you must be registered in the VetBiz Registry. (g) Citation of any current or past customers (i.e., within the past two (2) years) to include contract number, point of contact telephone number or e-mail address; and (h) Other material relevant to establishing core competencies of the firm. (i) Contractor shall include the terms and conditions of the warranty for all products listed in attachment. Response is due by noon Wednesday, July 17, 2018. Please submit e-mail responses to Mr. Jose Hernandez, Contract Specialist, at email address: contact@example.gov. Your response should include a STATEMENT OF CAPABLILITY, DUNS#, BUSINESS SIZE, AND SOCIO-ECONOMIC STATUS information as explained above. Please place Attention: 640 - CA3-379 Correct Life Safety Deficiencies Sunnyvale, CA in the subject line of your email. This notice is to assist the VA in determining sources only. NOTES: Issuance of this notice does not constitute any obligation whatsoever on the part of the Government to procure these services, or to issue a solicitation, nor to notify respondents of the results of this notice. No solicitation documents exists at this time. The Department of Veterans Affairs is neither seeking for quotes nor accepting unsolicited quotes, and responses to this notice cannot be accepted as offers. Any information the vendor considers proprietary should be clearly marked as such. The U.S. Government will not pay for any information or administrative costs incurred in response to this RFI. See Attachment 1 Draft Scope of Work Scope of Work Correct Life Safety Deficiencies in The Lobby Building 1002 ONIZUKA 1080 Innovation Way Sunnyvale California VETERANS AFFAIRS SUNNYVALE CAMPUS Project Number: 640 CA3-379 PROJECT TITLE Scope of Work to Correct Life Safety Deficiencies in the Lobby LOCATION: Project site is located at the Building 1002 at 1080 Innovation Way Sunnyvale California 94089 POINT OF CONTACT: History: The existing steel framed building, identified as Building 1002 is a two-story office building surrounding a central Courtyard with approximate 50,000 square feet of gross floor area. In 2018, a lobby of approximately 7,050 square feet was constructed and added at the North-East corner of existing building. A portion of existing building had been remodeled adjacent to the new Lobby. The Combined new lobby and remodeled area contains: two Elevators, Stairway, Lobby, Entry, Toilets, Electrical and Communication rooms, Offices, Circulation and other functions. The newly completed Lobby and office area was not properly commissioned and have some Life Safety issues. This construction project is to address the Commissioning of the building and to Correct Life Safety Deficiencies. SCOPE OF WORK: Provide all, labor, material, tools, equipment and, transportation to complete the scope of work necessary to correct life safety deficiencies in the lobby, Sunnyvale Research Facility. The work shall include, but not be limited to the following: STATEMENT OF BID ITEM(S) ITEM I-EXTERIOR: Fence: Provide and install new 7 feet high galvanized chain link fence and fence gate as per paragraph 1.5G of specifications section 01 00 00. The fence posts should be securely drive into asphalt/ground. Ramp, Steps and Hand Rails: Demolish existing section of asphalt ramp protruding into the park lot as indicated and make sure existing asphalt ramp conforms to 1:20 slope minimum, if not add more asphalt material and correct the slope as required. Provide10 feet wide. Concrete Steps, color and finish shall match adjacent concrete pad/platform. Class 2 Aggregate Base. Compact subgrade a minimum of 90% testing, test result shall submit to Veterans Affairs record. Number #4 Rebar on 18 inches on center each way. Number #3 Nose Bar Provide 42 inches high steel pipe hand rails at existing Handicap Ramp, new front 10 feet wide Steps and around existing, 32 feet x 32 feet (2 feet high) Concrete Platform/pad in front of front entrance. Hand rail shall consist of top rail, intermediate rail, and posts. Fabricate hand rail from steel pipe, Connections may be standard fittings designed for welding. Space intermediate posts not over six feet on center between end post or newel post. Provide standard terminal fittings at ends of post and rails. Handrails and Top Rails of Guards shall withstand Uniform load of 50 lbf/ft. applied in any direction. Concentrated load of 200 lbf applied in any direction. Prime and Paint railings, paint to match color of the front lobby Cleaning and surface finish the base of existing concrete platform/pad Remove dirt and debris piled over the excavated area around the 2 feet high concrete platform /Pad located at front door of the lobby, compact subgrade a minimum of 85% and patch horizontal grade with asphalt paving to match the adjacent paved and finish vertical exposed concrete pad with cement to match adjacent surface. Stripe Paint at Parking lot: Strip paint the parking lot for 40 new parking lots/spaces and 3 accessible ADA parking stalls. Accessible ADA parking stalls to include one Van accessible and two standard accessible stalls as indicated. Provide truncated domes, parking space signage, parking stall emblem as indicated Remove and modify the sections of existing concrete side walk in front and side of new truncated domes plates and provide 8.33% slope on all three sides of plates to access the concrete walkway The parking stalls layout shown is for reference only and may not conform to actual standard dimensions shown, contractor to submit shop drawings for approval before sealcoating and stripping the area. Remove vegetation from any crack and along the edge of asphalt surface. Apply vegetation control herbicide. Clean existing asphalt with a high-power blower with air speeds existing 200 miles per hour and hand wire broom as necessary. Seal cracks with a product that suitable for crack size and compatible with sealcoating product. Sealcoat (2 applications at a rate of 0.11 0.13 gallon per square yard (yd2) with a Coal Tar Pitch Emulsion (C.T.P.E) sealer that meets or exceeds RP 355e and ASTM D5727 specifications During the completion all contractor work performance shall be done in a manner as to prevent water runoff, and possible contamination of soil or drainage areas, waterways. Restripe all 43(40 + 3) parking spaces with traffic marking paint white including handicap spaces, universal symbol of accessibility as indicated, provide curb Ramps to follow ADA Standards for Accessible Design (28 CFR Part 36) Contractor shall be responsible for removing all job-related trash and debris from landings, daily and apply to all applicable City, County, State, Federal codes and regulations as well as proper safety requirements. If landfill required testing on debris or soil the cost will bear on the general contractor ITEM II-FIRST FLOOR: Automatic Door Opener Remove existing Push button type door opener, patch the holes/opening left after the removal of existing push button type door opener match holes/opening with material to match adjacent materials. Provide new motion detector type automatic door opener to operate existing double swing door (heavy) of front lobby door. Provide 120/220 volts from the nearest electrical panel available with spare circuit breaker space. Automatic Swing door (heavy) opener with two positive infrared/body/motion sensors to operate the existing building s double swing front door. The lock key to override the motion sensor. Provide guard rails on both sides of the existing front door. For reference- The Specifications/model of existing double swing front door are: Door Operator 939D; ASSA ABLOY Entrance System; Besam SW200i; UL 991; Besam Fire Door Operator with Automatic Closer Issue Number #0041374; The design to comply with specifications section 08 71 13 Fire Exit Door Remove existing two 2 6 wide double swing doors (marked 110 on drawing) , replace it with one right hand side solid 3 feet wide and seven feet high door and another 2 feet wide fixed door, this single 3-foot-wide door to open out away from the lobby area. Color/finish to match existing door. Reuse existing door closure device(s) Provide Panic Exit Device/ Hardware UL Fire rated, ANSI A156.3 Grade 1, ADA Compliant to the new door, which will be used as emergency exist. For specifications, refer specification section 08 71 00. Provide manual fire pull station next to this exit door as required per NFPA and connect it to existing fire alarm system . The system layout of pull station , document submittal preparation, engineering and supervision of installation and testing shall be provided by a technician that is certified NICET level III or a registered fire protection engineer as described in specification section 28 31 00. .Seismic Plate Cover the 12-inch-wide structural steel plate on the floor, in front of the of the swing door with carpet to avoid tripping hazard. Color to match the adjacent flooring. Electrical Room In Fire rated Electrical Room, remove existing expanded foam type sealants and close all openings in walls, floors and roof decks with Fire Stop material, sealants, as per specifications section 07 84 00 Elevator Room In Fire rated Elevator Room, remove existing expanded foam type sealants and close all openings in walls, floors and roof decks with Fire Stop material, sealants, as per specifications section 07 84 00 Provide wall mounted door sign on strike side of the elevator door, sign should read: 1A-105 Specs-Provide exterior grade material. Assembly, mounting height, color and location to match interior sign layout. ITEM III SECOND FLOOR : Fire Exit Door Provide Panic Exit Device/ Hardware UL Fire rated, ANSI A156.3 Grade 1, ADA Compliant to the existing right-hand side double swing door (Which opens outside or away from the lobby) This door will be will be used as second emergency exist. For specifications, refer specification section 08 71 00 Provide manual fire pull station next to this exit door as required per NFPA and connect it to existing fire alarm system. The system layout of pull station , document submittal preparation, engineering and supervision of installation and testing shall be provided by a technician that is certified NICET level III or a registered fire protection engineer as described in specification section 28 31 00 Communication Room 206 In Communication Room, remove existing expanded foam type sealants and close all openings in walls, floors and roof decks with Fire Stop material, sealants, as per specifications section 07 84 00. Dislodge all (except telephone rack) utilities, racks including but not limited to control/electrical/CCTV panels from existing plywood paneling in such a manner as to prevent damage which would be detrimental to re-installation and reuse. and replace existing plywood panels with ¾ inch thick MIL-L-19140E Fire Retardant Treated Plywood wall panels. Do not paint the plywood with fire rating stamps exposed and visible, for future inspections. Re attached/install the removed utilities, racks and control/electrical/CCTV panels etc. NOTE-keep the existing plywood section (S) where telecom vertical rack is attached. Copper Tie Cables from existing Demark/Telecom Room #D1 on first floor to communication/IT room 206 on the second floor. Test for continuity the existing 50 pair copper tie cable installed in the existing 2-inch diameter conduit between Demark Room# D1 on the first floor and communication Room # 206 on the second floor and terminate on 110 blocks on both ends. If defective provide and test new 50 pair copper tie cable. Single Mode (SM) fiber from existing Demark/Telecom Room D1 on first floor to communication/IT room 206 on the second floor. Provide new 24 strands of Single Mode (SM) fiber in existing conduit(s) between existing Demark/Telecom Room #D1 on first floor to communication/IT room 206 on the second floor. It should be terminated on both ends with LC connectors in a fiber tray at the top of the new relay rack. (Note-There is existing 12 strands of Single Mode (SM) fiber installed but not terminated) Modify and provide any pull boxes for new cables in the existing conduits if required. For installation requirement see spec sections-27 05 11, 27 10 00 and Codes of Practice. Wireless Access Points WAP Contractor shall survey and verify the locations and point of termination. of wireless access point cabling (WAP). Provide a print showing where they are terminated in term of the 6 WAP ports on the patch panel on Second Floor I.T Closet. ITEM IV COMMISSIONING COMMISSIONING. The commissioning agent shall be subcontractor(s) of the General Contractor and shall report to and paid by the General Contractor. With the help of commissioning agent, General Contractor to provide commissioning of the following newly installed systems. Under this contract Commissioning process includes but not limited to- Documentation/certifications , testing and startup of these systems, as well as training of the VA s Operation and Maintenance personnel in accordance with the requirements (relevant sections to this project) of VA TIL specification Section 01 91 00. which may be obtained from the VA Facilities Management Technical Information Library (TIL) at the web site: http://www.cfm.va.gov/TIL/ . NOTE- Some of the Construction submittals of the installed equipment including Elevators and TAB report of HVAC system are available and can be provided to the contractor at site during commissioning phase, but O&M (Operation and Maintenance) manuals of the installed systems are not available. The submittals and O&M of HVAC equipment is also not available. Commissioning agent/ General Contractor will gather all the necessary information required for commissioning of the installed systems, the means of investigation should include but not limited to studying the drawings, specifications and Construction submittals of project, consulting the Manufacturer of installed equipment, and field investigation. Elevators History- The Final inspection of elevators were performed on February 28, 2017. The certification report is attached as enclosure. The elevators were certified by Steve Greene & Associates of with following Two deficiencies The telephone lines remain inoperative. There is no signage to identify the Elevator Machine Room ((The point of contact of the elevator inspection company is Steve Greene at +1 (555) 000-0000) After the telephone system is installed, connect the existing elevator phones system to the new phone system and make the system operational. For reference see specification section 14 24 00 of project #640-379 and specification Section VA TIL specification 01 91 00. Contractor to hire third party ANST/NAESA qualified elevator inspection company and recertify the Elevators. Fire protection and Fire alarm systems: As specification sections 21 05 11, 21 08 00, 21 13 13 and 28 31 00of project #640-379 (refer paragraph 1.08) and relevant specification Section 01 91 00 HVAC System: As specification section 23 08 00 of project #640-379 and specification Section 01 91 00 and drawings. Existing HVAC systems are comprised of: Rooftop Single Package Air conditioning system. (1 each) and electric reheat VAV boxes ((8ea.)systems. Since the air handling unit is continuously in operation for more than one year. Contractor to perform the regular maintenance, which includes but not limited to replace the air filters, check fan belts; lubricate all the dampers, motor and fan as needed. The BACnet controller is sitting in telephone room #206, after the telephone system setup, program/adjust the controller as needed. Split system heat pumps (5each) Exhaust fan (1 each). Since the exhaust fan unit is continuously in operation for more than one year. Contractor to perform the regular maintenance, which includes but not limited to check fan belts; lubricate motor and fan as needed. For fire/smoke dampers, and VAV boxes refer attached project #640-379 drawings and specifications Check the functionality of all the fire/smoke dampers NOTE-The Decentralized unitary HVAC systems are free standing systems installed to serve the lobby area only. The main system will be installed at later stage which will include chillers and hot water/steam systems etc., Domestic Hot and Cold-Water Systems No commissioning is required for Domestic water system, since there is no water heater or heat exchanger, there are instant water heater under the sinks. Sterilization As per para 3.3 of specification 22 11 00 of project #640-379, thoroughly flush and sterilize the interior domestic water distribution system in accordance with AWWA C651. Use either liquid chlorine or hypochlorite for sterilization B DEDUCTIVE ALTERNATE NO.1 1. Delete Item #4 sub para graph Modify existing concrete side walk to provide 8.33% Slope on all three sides of new truncated dome plates Replace it with Provide minimum 8.33% slope to the new three asphalt access aisles (Detail 3 of drawing GI-002-ADD) in front of truncated dome plates 1.07 SITE INVESTIGATION: Investigate the site per FAR 52.236-3 to ascertain the general and local conditions, which can affect the work or its cost. Access to the site will be available during normal working hours. Contact COR (POC) a minimum of 24 hours in advance to arrange site access. Contractor can start at 07:00 am 4:00 pm, Monday to Friday. Conduct site visits and field surveys to verify that the facility s existing site conditions, configuration conforms to as-built documentation, and to establish controlling site parameters 1.08 ENCLOSURES: The following enclosure are part of the construction package. A PROJECT SCOPE/CONSTRUCTION DRAWINGS: The following 11 x17 markup drawings are not to scale. These drawings only indicate the location and Scope of Work. Refer relevant Specifications and drawings of project # 640-379 for complete detail Drawing Number Title GI-001-ADD Site Plan GI-002-ADD Parking Lot Details AS101 ADD First Floor Plan AS102 ADD Second Floor Plan T-101 ADD Telecommunications First Floor T-102 ADD Telecommunications Second Floor T-201 ADD Telecommunications First Floor Ceiling Plan T-202 ADD Telecommunications Second Floor Ceiling Plan T-203.ADD Existing communication conduits location B COPY OF ELEVATORS CERTIFICATION C CODES OF PRACTICE: Design and Construction Guidance from the Office of Information and Technology (OI&T). Use codes of practice for designing and construction of IT/Communication systems D SPECIFICATIONS: The following specifications sections are provided with this scope- Section 01 00 00, Section 01 33 23, Section 01 52 50 Section 07 84 00, Section 08 14 00, Section 08 71 00, Section 08 71 13, Section 27 05 11, Section 27 10 00, and Section 28 31 00. 1.09 SPECIFICATION SECTION 01 91 00: Contractor to obtained from the VA Facilities Management Technical Information Library (TIL) at the web site: http://www.cfm.va.gov/TIL/ . 1.10 CONSTRUCTION SCHEDULE: Contractor will submit the Construction Documents for review with adequate copies to ensure retention by the Veterans Affairs Palo Alto Health Care System 1.11 CONSTRUCTION PERIOD: Total time 120 calendar days including design construction, time for Punchlist inspection and construction touchups. 1.12 SUBMITTALS: Submit Security Plan, Fire Safety Plan, Health and Safety Plan, Infection Control Risk Assessment Plan, and Environmental Protection Plan prior to mobilization.

More opportunities from Department Of Veterans Affairs → 261-NETWORK Contract Office 21 (36C261)

Same awarding agency

NAICS: 236220
New
Federal
Z2DA--654-24-004 | Remediate Old Parking Garage
Solicitation # 36C26126Q1297
Solicitation 36C26126Q1297 is a firm-fixed price Design-Build requirement issued by the Department of Veterans Affairs Network Contracting Office 21 to remediate an old parking garage at the VA Sierra Nevada Health Care System in Reno, Nevada. This project is set aside for Service-Disabled Veteran Owned Small Businesses under NAICS 236220, with an estimated project magnitude between 1,000,000 and 5,000,000 dollars. The successful contractor will be responsible for all design and construction services, including repairs and renovation, with a required period of performance of 210 calendar days from the issuance of the Notice to Proceed. The award process is conducted in two phases, where technical management and past performance are significantly more important than price. Phase 1 evaluates the technical and risk approach, schedule phasing, specialized project experience, and key personnel. Required key personnel, including the Project Manager, Project Superintendent, Safety Officer, Architect, and Civil Engineer, must possess at least five years of experience and have completed three projects of similar size and scope. Phase 2 focuses on price. Offerors must submit a detailed price breakdown and provide bid, payment, and performance bonds, as well as a certificate of insurance within 10 days of award. All proposals must be submitted electronically by November 20, 2026, at 15:00 PST.
Commercial and Institutional Building Construction

POSTED

about 12 hours ago

DEADLINE

in 24 days
View Details
NAICS: 811210
New
Federal
FRESNO- Radiology X-Ray System PM Services
Solicitation # 36C26127Q0118
The Department of Veterans Affairs, Network Contract Office 21, intends to award a sole source firm fixed price contract to GE Precision Healthcare LLC for corrective and annual preventative maintenance of radiology X-ray systems at the Fresno VA Medical Center. The scope of work covers specific equipment including the GE Healthcare XR Definium 5000, Optima CT660, Powerware MV UPS 10KVA, OEC Elite 31cm CFD, and GE Workstation Advantage 4.7. GE Precision Healthcare is identified as the sole manufacturer and authorized vendor capable of providing the necessary parts and specialized repair services to satisfy this requirement. The contract is categorized under NAICS code 811210 with a size standard of 34 million dollars. The period of performance consists of a base year running from December 27, 2026, to December 26, 2027, with four subsequent one-year option periods extending through December 26, 2031. Key performance requirements include an on-site response time within four hours and next-day delivery of repair parts by 10:30 a.m. All services must comply with OEM technical specifications and adhere to NFPA-99, TJC, NEC, OSHA, HIPAA, and Federal and VA security standards. The contractor is required to provide software and firmware updates, safety or reliability modifications, and equipment verification at no additional cost. Maintenance is to be performed during normal business hours at the VA Outpatient Clinic premises, with all work documented via Vendor Engineering Service Reports and validated by the COTR and equipment users.
Electronic and Precision Equipment Repair and Maintenance

POSTED

about 12 hours ago

DEADLINE

in 11 days
View Details
NAICS: 236220
New
Federal
Z2DA--Project: 459-27-004 ACC MOD 2 Renovation
Solicitation # 36C26126Q1295
Solicitation 36C26126Q1295 is a firm-fixed-price construction project issued by the Department of Veterans Affairs, Network Contracting Office 21, for the renovation of Primary Care Modular 2 at the Spark M. Matsunaga VA Medical Center in Honolulu, Hawaii. The project scope involves renovating approximately 2,650 square feet within Building 30, including the installation of healthcare-grade flooring, wall painting, LED lighting upgrades, electrical outlet replacement, and the refreshing of restrooms and doors. The estimated project magnitude is between $500,000 and $1,000,000, with a total performance period of 143 calendar days from the Notice to Proceed. To minimize disruption to medical operations, all construction activities must be performed after 1700 hours, and work must be phased to ensure the continued partial operation of the facility. This procurement is a total set-aside for Service-Disabled Veteran-Owned Small Businesses (SDVOSBs) under NAICS code 236220. Eligible offerors must be verified in the SBA Veteran Small Business Certification Program. Award will be based on price only. Required submission documents include a detailed price breakdown by division, completed representations and certifications, and a bid bond with a visible raised seal. The contractor must adhere to strict safety and health protocols, including VHA Infection Control Risk Assessment (ICRA) and Pre-Construction Risk Assessment (PCRA) standards. Additionally, the project is subject to the Davis-Bacon Act for labor standards and Buy American requirements for construction materials.
Commercial and Institutional Building Construction

POSTED

about 12 hours ago

DEADLINE

in 24 days
View Details
NAICS: 621340
New
Federal
Q403--Mather Ergonomic Evaluations
Solicitation # 36C26127Q0068
The Department of Veterans Affairs, Network Contracting Office 21, is soliciting quotes for ergonomic evaluation and training services for the VA Northern California Health Care System. This total small business set-aside contract, under NAICS 621340, requires the contractor to provide all labor, equipment, and supervision to perform individual workstation evaluations and one-on-one consultation training for employees across 12 sites, including one medical center and 11 outpatient clinics. The scope includes an estimated minimum of 250 assessments per year, with a requirement to respond to requests within four weeks. Key deliverables include detailed written reports in Microsoft Word format, monthly itemized invoices, and monthly progress reports. The period of performance consists of a base year from November 15, 2026, to November 14, 2027, with two subsequent one-year option periods. To qualify, the contractor must demonstrate at least five years of experience as an industrial safety or hygiene specialist, industrial ergonomist, or human factors specialist and hold certification from a nationally recognized board. The contract manager and technician supervisor must also possess five years of applicable experience. Due to the need for prompt site visits, preference is given to contractors located within 200 miles of Mather, California. Award decisions will be based on a best-value determination considering technical capability, past performance, and fixed unit pricing. Proposals must be submitted in three separate volumes—technical approach, past performance, and pricing—and must adhere to specific page limits and electronic submission guidelines. Performance will be monitored via a Quality Assurance Surveillance Plan, and all services must comply with VHA directives and NCHCS policies.
Offices of Physical, Occupational and Speech Therapists, and Audiologists

POSTED

about 12 hours ago

DEADLINE

in 2 days
View Details
NAICS: 339112
New
Federal
6640--Perfusion Cell Saver Lease and Service
Solicitation # 36C26127Q0077
Solicitation 36C26127Q0077 is a firm-fixed-price requirement issued by the Department of Veterans Affairs Network Contracting Office 21 for perfusion cell saver lease and professional services at the VA Sierra Nevada Healthcare System in Reno, Nevada. The contractor is required to provide a leased cell saver machine, such as the LivaNova Xtra ATS System or an equal alternative, along with a credentialed auto-transfusionist to operate the equipment during surgical cases. The scope of work includes all necessary maintenance and the provision of all sterile disposable supplies, with an estimated annual volume of 12 procedures. The performance period is structured across five one-year increments from November 1, 2026, through October 31, 2031. The contract is designated as a HUBZONE Small business set-aside, and awards will be based on a comparative evaluation of technical capabilities, delivery timelines, price, and authorization from the Original Equipment Manufacturer or an authorized distributor. Special preference is given to Service-Disabled Veteran-Owned Small Businesses (SDVOSB) and Veteran-Owned Small Businesses (VOSB). Technical requirements mandate strict adherence to safety standards, including Class I Type B electrical safety and specific blood processing parameters for temperature, suction levels, and hematocrit ranges. Contractors must also provide one year of identity theft insurance with 20,000 dollars in coverage and maintain rigorous procedural documentation for every case.
Surgical and Medical Instrument Manufacturing

POSTED

about 12 hours ago

DEADLINE

in 1 day
View Details

Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS