Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, November 11 at 2:00 PM ET

Register Free →

This Combined Synopsis/Solicitation opportunity from Department Of Veterans Affairs was posted on September 7, 2018. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

65--Two (2) Eye Lanes - VA Outpatient Clinic Amendment includes revised specifications for eye lanes - see FBO Description

Awarded
36C25918Q9868Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 339115
New
Federal
N065--Slit Lamp Installation for the Captain James A. Lovell Federal Health Care Center (FHCC), located at 3001 Green Bay Rd., North Chicago, IL 60064.
Solicitation # 36C25227Q0055
Solicitation 36C25227Q0055 is a firm fixed price request for professional installation services for nine slit lamps in the optometry department at the Captain James A. Lovell Federal Health Care Center in North Chicago, Illinois. The scope of work requires the contractor to relocate the equipment from a non-climate-controlled warehouse to designated clinic rooms and perform assembly, mounting, alignment, and functional checks to ensure clinical readiness. All work must be completed within 60 days of the contract award and must adhere to manufacturer specifications from Haag-Streit/Reliance, as well as OSHA, FHCC safety, and infection control standards. Key deliverables include fully operational equipment, verification of calibration, installation reports, and manufacturer documentation. This opportunity is set aside for Service-Disabled Veteran-Owned Small Businesses (SDVOSB) under NAICS code 339115. The government will award the contract to the responsible offeror providing the most advantageous offer based on a comparative evaluation of price, technical requirements, and relevant experience. Invoicing must be submitted electronically via the Tungsten Network, with payments made in arrears through Electronic Funds Transfer. Offerors are required to provide a complete quote including the SF 1449, UEI, and SAM registration, while ensuring compliance with the Resource Conservation and Recovery Act for the disposal of all associated materials.
252-NETWORK Contract Office 12 (36C252)

POSTED

3 days ago

DEADLINE

in 15 days
NAICS: 339115
New
Federal
Invitation for Bids - Vision Correction Assembly
Solicitation # W912CH26BA014
The Army Contracting Command - Detroit Arsenal is soliciting bids for a five-year, Firm-Fixed-Price, Indefinite Delivery/Indefinite Quantity (IDIQ) contract for the manufacture and delivery of the Vision Correction Assembly, identified by NSN 4240-01-631-8044 and Part Number 5-1-4208. This non-commercial requirement involves production based on a Government-owned Technical Data Package (TDP) with Distribution Statement D export controls, requiring offerors to have a valid DD Form 2345 certification. The contract includes a guaranteed five-year minimum quantity of 30,690 units, with a maximum estimated quantity of 1,216,196 units. Key performance requirements include First Article Testing of 200 units, Production Lot Testing, and adherence to ISO 9001:2015 quality standards. The government intends to award a single contract to the responsible bidder offering the lowest total price, evaluated across five ordering years and a First Article Test Report. Bids must be submitted electronically by November 13, 2026, with a virtual bid opening scheduled for November 18, 2026. Deliveries are designated as FOB Destination to the Blue Grass Army Depot in Kentucky. Contractors are required to utilize the Wide Area WorkFlow system for invoicing and must comply with strict packaging and marking standards, including MIL-STD-129 and MIL-STD-2073-1. Access to the TDP may further require a Use and Non-Disclosure Agreement.
W6QK Acc- Dta

POSTED

6 days ago

DEADLINE

in 15 days
NAICS: 339115
Federal
Corneal Analyzer OPD-Scan III Wavefront Aberrometer
Solicitation # 36C24W27Q0010
The Department of Veterans Affairs Veterans Health Administration is conducting market research via a Sources Sought Notice for the procurement of one OPD-Scan III Visual System Wavefront Aberrometer/Corneal Analyzer for the San Francisco VA Health Care System in Oakland, California. This is a brand name or equal requirement, meaning the government will accept the specified Marco system or a functionally equivalent product that meets all salient physical and performance characteristics. The system must provide combined functionality for auto-refraction, auto-keratometry, topography, aberrometry, and pupillometry, with a spherical power range of -20.00 to +22.00 D and cylindrical power of 0.00 to ±12.00 D. It must also be compatible with Marco TRS-6100/5100 and NIDEK RT-6100 automated refraction systems. The final contract will be a Firm Fixed Price award requiring a minimum one-year manufacturer warranty. To prevent the acquisition of gray market items, the vendor must be an original equipment manufacturer or an authorized dealer/distributor, providing an authorization letter to verify that OEM warranty and service are maintained. Delivery is set as FOB Destination to the Oakland facility, with a specific constraint that items cannot be delivered before February 10, 2027. All deliveries must occur during normal business hours (0800 to 1500 PST) and be coordinated one week in advance. The Buy American Statute applies to this procurement. This current notice is for planning and size determination purposes only and does not constitute a solicitation or a binding offer.
Rpo West (36C24W)

POSTED

9 days ago

DEADLINE

in 5 days

General Info

Contract Value

$470,535.51

NAICS

339115 - Ophthalmic Goods Manufacturing

Place of Performance

Lawton VA Outpatient Clinic;4303 Pitman Street;Fort Sill, OK 73503 USA, CO

Set-Aside

SDVOSBC

Award Issued Date

Documents

0

No documents available

Documents will appear here when they are available.

AI Contract Breakdown

Uniform Contract Format

No documents to break down

The breakdown needs solicitation documents. None were found from this contract's source.

Timeline

1 update
PhaseAwarded
Posted

Combined Synopsis

Notice updated

Response deadline changed from Aug 29, 2018 to Sep 12, 2018. The notice title changed. The notice description changed.

Awarded

Contract was awarded

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Veterans Affairs → Network Contract Office 19 (36C259)
ContactsNo contacts available
OfficeGreenwood Village, CO, 80111, USA
Office AddressGreenwood Village, CO, 80111, USA
ContactsNo contact information available

Full Description

Show more
This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in Subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; proposals are being requested and a written solicitation will not be issued. This solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular (FAC) 2005-89 issued and effective July 14, 2016. This solicitation VA25918Q9868 CSSA1, amendment to previously issued Combined Solicitation, is issued as a request for quote (RFQ). The North American Industry Classification System Code (NAICS) for this procurement is 339115 (Ophthalmic Goods Manufacturing). This RFQ is being issued as a Service Disabled Veteran Owned Small Business set-aside under NAICS Code 339115. SBA Small Business Size Standard is 1000 employees. Any Award Made as a Result of this Solicitation will be made on an All or Nothing Basis. All Items being Solicited (Products and/or Receivables as appropriate) must be of New Manufacture; No Remanufactured or "Grey Market" items allowed. Grey market items are Original Equipment Manufacturers (OEM) goods sold through unauthorized channels in direct competition with authorized distributors. This procurement is for new OEM equipment only for a VA Medical Center. - No remanufactures or grey market items will be acceptable. Vendor shall be an OEM, authorized dealer, authorized distributor or authorized reseller for the proposed equipment/system, verified by an authorization letter or other documents from the OEM, such that the OEM s warranty and service are provided and maintained by the OEM. - All software licensing, warranty and service associated with the equipment/system shall be in accordance with the OEM terms and conditions. FAR 52.212-4 applies to all Solicitations and Awards. Department of Veterans Affairs, VISN 19, Oklahoma City VA Medical Center, is seeking a quote for the following requirements. Solicitation and evaluation of offers are to be in accordance with (IAW) VAAR 852.211-73. Oklahoma City VA Health Care System Oklahoma City, OK 73104 SCOPE OF WORK AND GENERAL SPECIFICATIONS FOR COMPLETE EYE LANE EQUIPMENT PURCHASE Background The Oklahoma City VA Health Care System (OKC VA HCS) provides comprehensive ophthalmology service for veterans. We are renovating new space for the Eye Clinic and will be adding two new exam lanes which need to be equipped to match existing eye lanes. Project Scope The Oklahoma City VA HCS needs to purchase two (2) complete eye lanes. Specifications The Oklahoma City VA HCS specifications are designed to outline all the Oklahoma City VA HCS Ophthalmology Department and Biomedical Engineering requirements. These requirements will be provided to the Point of Contact (POC) before final approval. The ophthalmic eye lane equipment specifications are provided below: Offerer must meet or exceed the specifications of the following: Line items and descriptions: Full Power Tilt Examination Chair (Reliance FX-920-L Chair #20 Pearl OR EQUAL): Dual controls for base and top tilt Single lock adjustable concave headrest Auto return button to return chair to upright starting position Hydraulic base 600 pound capacity Safety switch to disable controls and footswitches Armrests that lock in place and allow the patient to sit or leave from either side of the chair Electrical - 110 Volt , 60 Hz, 8.0 amperes CSA, C/US Certificate of Compliance Reliance FX-920 Cushion set #206 charcoal Instrument Stand (Reliance 7800-IC Floor Unit #20 Pearl OR EQUAL): 3 Rechargeable wells for handheld instruments Wheelchair option to bring refractor and slit lamp arms to patients in any model wheelchair Overhead lamp with arm that adjusts without use of tools Switches to control a chart projector and control the intensity of the overhead lamp Adjustable slit lamp arm with use of a single hand and a 12 range of travel Upper Refractor Arm with 50 lb capacity Pneumatic Examination Stool (Reliance 5346 Pneumatic Stool, 301 Black OR EQUAL): Adjustable and tilted backrest Height adjustment from 19.5 to 25 Chair Mover OR EQUAL: Low profile Unlock and roll mechanism Fits rectangular base up to 22.5 wide Phoroptor (Reichert 11635B Plus Cylinder Ultramatic RxMaster Phoroptor Refracor, Black OR EQUAL): ± 0.25 Flip Cross Cylinder +1.50 Retinoscopic lenses Accessory Case Nylon Face Shields Rotochart Reading Rod with Card Holder Sphere: -19.00D to +16.75D with 0.25D steps Cylinder Power: 0.00D to 6.00D with 0.25D steps Cylinder Axis: 360 degrees with 5 degree graduations Cross Cylinder: ± 0.25 Prism: 0 to 20 diopter with 1 prism diopter graduations P.D.: 48 to 75 mm with 1 mm graduations Vertex Distance: 13.75 mm, graduations extend range by 6 mm Reading Distance: 5 to 28 inches Auxiliary Dial: 10 lenses plus 2 open apertures Slit Lamp (Haag-Streit 900 BQ OR EQUAL): Freeze technology to capture the moment you press the trigger History trigger to rewind and freeze the last few seconds Depth of field control to facilitate complete control of the depth of field Magnification with standard eyepieces: 6.3x, 10x, 16x, 25x, 40x Tungsten illumination Maximum intensity of 600,000 Slit Width/Length: 0-8mm / 1-8mm Tonometer (Haag-Streit BP/BQ/BX Applanation Tonometer OR EQUAL): Two resting positions Swing in front of the microscope to examine both left and right eye Wireless Digital Binocular (Keeler Vantage Plus LED Wireless Indirect with slimline charging system OR EQUAL): Software that allows use of any usb interface Provide still and dynamic images Wall mount that stores an extra lithium battery for back up Optics and mirrors automatically adjust when aperture changes 3 dimensional stereoscopic views of the retina through all pupil sizes 90D Aspheric Lens (Volk) OR EQUAL: Field of View: 74/89 degrees Image Mag: 0.76x Laser Spot: 1.32x Working Distance: 7mm 20D Aspheric Lens (Volk) OR EQUAL: Field of View: 46/60 degrees Image Mag: 3.13x Laser Spot: 0.32x Working Distance: 50mm Lombart Standard Refraction Desk with Console, Right Hand OR EQUAL: Large writing surface Angled trial lens drawer, 21 x 13 Ample drawer space to facilitate access to a wide selection of ancillary tests and supplies Electronic unit to automatically adjust room and fixation lighting and power diagnostic hand instruments Hand instrument console with three rechargeable wells, main switch, rheostat, and auxiliary instrument switches Optional indirect hanger control to control room lighting, on/off or dim and powers indirect Optional slit lamp switch to power slit lamp and automatically dim room light Auto Projector (Marco CP-770) OR EQUAL: LED illumination system Programmable up to 33 charts in any order Conduct exam by pressing one button on the remote control to advance to next chart Option to randomly select any chart Option to isolate and maneuver individual horizontal or vertical lines Brightness control to adjust brightness intensity of projected image Automatically compensate for any fluctuation in supply voltage or change in refraction distance Wall mount (for Marco CP-600/670/690/770) Front Surface Mirror Set Limestone (12 x 12 ) Retinoscope (Welch Allyn 18245 Elite Streak OR EQUAL): Dust-Free Sealed Optics Cross Linear Polarization Filter Switch Continuous Rotation External Focusing Sleeve Halogen lamp Detect corneal abrasions with cobalt blue filter Red-Free filter used with any aperture 28 focusing lenses with range of -25D to +40D 3.5v Halogen Coaxial Ophthalmoscope (Welch Allyn 11720 OR EQUAL): Coaxial optics to produce a shadow-free spot, easier entry into undilated pupils, and a larger field of view Detect corneal abrasions with cobalt blue filter Polarizing filter virtually eliminates corneal reflection Sealed optics keep out dust and dirt 18 unique aperture/filter combinations for greater versatility Red-free aperture may be used with any aperture 28 focusing lenses with a range of -25 to +40 diopters 3.5v Halogen Finnoff Transilluminator (Welch Allyn 41100 OR EQUAL): Halogen HPX lamp provides light output for true tissue color Fiber-optic light transmission provides cool, distal light for improved comfort Provides consistent, long-lasting illumination Optional cobalt blue filter 3.5v NiCad Well Handles (Welch Allyn 71670 OR EQUAL): Rechargeable handles compatiable with all listed Welch Allyn hand instruments Full Diameter trial lens set with plus cylinders in case OR EQUAL: Comprehensive set of full diameter plus and minus sphere, plus cylinder, prism and accessory lenses Metal trial frame Lens set in removeable tray with carrying case Additional accessories OR EQUAL accessories: Horizontal prism bar Vertical prism bar S-22 Loose Prism set Ishihara 14 plate Book Test Chart Stereo Fly Test Topcon Lensometer with external scale Snellen reading card Delivery Location: Lawton VA Outpatient Clinic 4303 Pitman Street Fort Sill, OK 73503 Commercial Items Terms and Conditions: The selected offeror must comply with the following commercial item terms and conditions, which are incorporated herein by reference: FAR 52.212-1, Instructions to Offerors - Commercial Items, applies to this acquisition; 52.212-2, Evaluation Commercial Items, FAR 52.212-3, Offeror Representations and Certifications - Commercial Items - the selected offeror must submit a completed copy of the listed representations and certifications; FAR 52.212-4, Contract Terms and Conditions - Commercial Items; FAR 52.212-5, Contract Terms and Conditions Required To Implement Statutes or Executive Orders-Commercial Items, paragraph (a) and the following clauses in paragraph (b): 52.204-7, 52.204-10, FOB Destination is in accordance with FAR 52.247-49, 52.204-13, 52.222-3, 52.222-19, 52.222-21, 52.222-26, 52.222-36, 52.223-18, 52.225-13, 52.232-33 and 52.247-34. The full text of the referenced FAR clauses may be accessed electronically at https://www.acquisition.gov/far/. The following VAAR clauses are to be incorporated by reference: 852.203-70, Commercial Advertising; 852.232-72, Electronic Submission of Payment Requests; 852.246-71, Inspection; The full text of the referenced VAAR clauses may be accessed electronically at http://www.va.gov/oal/library/vaar/. SAM Requirement: This solicitation requires registration with the System for Award Management (SAM) prior to award, pursuant to applicable regulations and guidelines. Registration information can be found at www.sam.gov. Additionally, all Veteran Owned Businesses who respond to a solicitation on this project must be registered with the Department of Veterans Affairs Center for Veterans Enterprise VetBiz Registry located at http://vip.vetbiz.gov. In addition, the following information is required for your quote to be considered: -Estimated delivery time (ARO): -Complete company name and address: -Company Point of Contact: -Email -Phone Number: -DUNS Number: Submit quotation and all supporting documentation to contact@example.gov. Offers are to be provided no later than 5:00 pm (MST) 12 September 2018. Please feel free to contact me, if you have any questions, at contact@example.gov.

More opportunities from Department Of Veterans Affairs → Network Contract Office 19 (36C259)

Same awarding agency

NAICS: 339112
New
Federal
6695--SURGERY GLOBUS INSTRUMENT SET
Solicitation # 36C25927Q0043
The Oklahoma City Veterans Affairs Health Care System requires one complete Globus Medical instrument set for use in neurology and orthopedic spine surgeries. This comprehensive solution must include all necessary components for functionality, such as cables, connectors, and mounts, and must adhere to stainless-steel standard operating procedures. The instruments must be reusable and specifically designed for spinal procedures in the operating room. The contractor must be an expert in the neuro and ortho spine field and is responsible for replacing any malfunctioning or broken items at no cost to the VA for the first 12 months following purchase, coordinating maintenance with the OKC VAHCS Biomedical Engineering Department. This procurement is identified as a sources sought notice under NAICS code 339112 and is set aside for Service-Disabled Veteran-Owned Small Businesses. Deliveries to the Oklahoma City facility are required Monday through Friday between 07:00 and 16:00. The instrument set consists of 35 specific line items, including various pedicle probes, rod templates, ratcheting handles, driver shafts, and taps. Interested vendors must provide a capability statement, business size information, country of origin, and estimated lead times. There are no security accreditation requirements as the contractor will have no access to patient records or restricted hospital areas, and no VA employee training is required.
Surgical and Medical Instrument Manufacturing

POSTED

1 day ago

DEADLINE

in 8 days
View Details
NAICS: 513210
New
Federal
R604--Mail Tracking Service
Solicitation # 36C25927Q0017
Solicitation 36C25927Q0017 is a firm-fixed price contract set aside for Service-Disabled Veteran-Owned Small Businesses (SDVOSB) to provide a web-based package and mail tracking system for the Department of Veterans Affairs. The primary site of performance is the Rocky Mountain Regional VA Medical Center in Aurora, Colorado, specifically within the KS-100 SCMS Warehouse. The system must be capable of processing approximately 250,000 parcels and will initially support up to 12 users. The contractor is responsible for providing all necessary hardware, including one barcode printer, 12 scanners with integrated signature pads, and one mobile device, as well as all associated consumables and routine replacement parts. The software will operate as a standalone system not connected to the VA network, meaning it should be SaaS permitted and will not require integration with internal VA identity management or directory services. The contract consists of a base period from October 30, 2026, to October 29, 2027, with four subsequent one-year options extending the total potential duration to five years and six months. Quotes are due by 14:00 MT on October 30, 2026. Pricing must be comprehensive, including all initial hardware, installation, and implementation costs within the original quote, though the government accepts a higher base-year price to account for these non-recurring expenses. Technical support is required to align with warehouse operating hours of 6:30 a.m. to 2:30 p.m. Award will be based on a comparative analysis of technical capability, price, and past performance, with a strict requirement that offerors be VetCert verified to be eligible for award.
Software Publishers

POSTED

2 days ago

DEADLINE

in about 23 hours
View Details
NAICS: 238110
New
Federal
554-27-117 Conduct Concrete and Civil Site Repairs.
Solicitation # 36C25926Q0826
Solicitation 36C25926Q0826 is a 100 percent set-aside for Service-Disabled Veteran-Owned Small Businesses (SDVOSB) to perform concrete and civil site repairs at the Rocky Mountain Regional VA Medical Center in Aurora, Colorado. The project, estimated between 100,000 and 250,000 dollars, involves comprehensive drainage remediation, sidewalk leveling, curb repair, and the removal and replacement of concrete sections to address trip hazards and improve snow removal. The scope of work includes 52 specific repair items and requires strict adherence to VA standards, AIA Construction Guidelines, and Joint Commission Environment of Care Standards. Performance must begin within 10 calendar days of award and be completed within 90 calendar days. The government will award the contract based on best value, evaluating offerors on price, past performance on at least two similar projects of 100,000 dollars or more within the last five years, and safety records, including an Experience Modification Rate (EMR) of 1.0 or less. Contractors must provide a Site Specific Safety Plan and ensure a competent person with a 30-hour OSHA card is on-site at all times. Proposals must be submitted via email to Elia L Ruiz Manzo by November 13, 2026, at 10:00 AM MT, and must include a signed SF-1442, a Limitations on Subcontracting certification, and past performance documentation.
Poured Concrete Foundation and Structure Contractors

POSTED

2 days ago

DEADLINE

in 15 days
View Details

Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS