Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, November 11 at 2:00 PM ET

Register Free →

This Pre-Solicitation opportunity from Department Of Veterans Affairs was posted on November 29, 2022. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

6515--Karl Storz Photodynamic Diagnosis System, Blue Light Cystoscopy Tower, with Cysview

Closed
36C26123Q0139Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

NAICS: 334510
New
DIBBS
VENTILATOR, VOLUME, PORT
Solicitation # SPE2DS-27-Q-0026
Solicitation SPE2DS-27-Q-0026 is a fixed-price request for quotations issued by DLA Troop Support Medical Supply Chain for the procurement of two portable EMV Plus volume ventilators (NSN 6515-01-586-5898). These units must include an internal battery charger, a 3-liter oxygen reservoir kit, and a military manual. Technical specifications include a weight of approximately 9.5 lbs, an operating voltage range of 100 to 240 VAC and 11 to 33 VDC, and an operating temperature range from -13 to +167 degrees Fahrenheit. This is a Foreign Military Sales requirement for Taiwan, with delivery required within 30 days after receipt of the order and a customer required delivery date of September 29, 2026. The contract mandates strict adherence to medical packaging and marking standards, specifically Medical Marking Standard No. 1, which supersedes MIL-STD-129. Items must be provided in sealed unit containers and commercial exterior shipping containers per MIL-STD-2073-1E. Item Unique Identification (IUID) is required in accordance with MIL-STD-130 and DFARS 252.211-7003. Inspection and acceptance are set at origin, and all invoicing must be processed electronically via Wide Area Workflow as a receiving report and invoice combo, including a Certificate of Conformance. This procurement is not a small business set-aside and incorporates various FAR and DFARS clauses regarding the Buy American Program, cybersecurity reporting, and sustainable products. Quotations are due by November 6, 2026.
MEDICAL SUPPLY CHAIN MD SURG FSF

POSTED

about 8 hours ago

DEADLINE

in 7 days
NAICS: 334510
New
Federal
Electro-Therapeutic Modalities for Pain Management (ETMPM) - Transcutaneous Electrical Nerve Stimulation (TENS) Procurement Program
Solicitation # 36C79126R0011
The Department of Veterans Affairs is soliciting proposals under Solicitation Number 36C79126R0011 to establish multiple single-award, Firm-Fixed-Price, Indefinite Delivery/Indefinite Quantity (IDIQ) base contracts for the Electro-Therapeutic Modalities for Pain Management (ETMPM) and Transcutaneous Electrical Nerve Stimulation (TENS) Procurement Program. This national program provides FDA-cleared electro-therapeutic devices and accessories to support non-opioid pain management across 168 VA Medical Centers and over 1,000 Community-Based Outpatient Clinics. The scope includes portable TENS units, portable Interferential Current (IFC) devices, thermal and non-thermal Short-Wave Diathermy (SWD) devices, and portable neuromodulation systems for headache disorders, along with associated consumables such as electrodes and lead wires. The procurement utilizes a VA Tiered Set-Aside Evaluation Approach, prioritizing Service-Disabled Veteran-Owned Small Businesses (Tier 1), followed by Veteran-Owned Small Businesses (Tier 2), other small business concerns (Tier 3), and finally other-than-small business concerns (Tier 4). Evaluation methodologies vary by item: CLINs X001 through X004 are awarded based on Lowest Price Technically Acceptable (LPTA) procedures, while CLIN X005 is evaluated using a Best-Value Tradeoff method, weighting technical factors at 60 percent, price at 25 percent, and past performance at 15 percent. Responsive proposals must include a signed SF 1449, a Technical Capability Statement, FDA 510(k) clearance letters, and three past performance documents. Non-manufacturers must provide OEM-issued Authorized Distributor Letters. Mandatory certifications include the Price Matrix (Attachment 0001), Limitations on Subcontracting (Attachment 0003), and either the Buy American Certificate (Attachment 0004) for small businesses or the Trade Agreements Certificate (Attachment 0005) for large businesses. Product samples for every offered CLIN/SLIN must be shipped to the Denver Logistics Service facility. Following several amendments, the final deadline for the receipt of all proposal documentation and product samples is November 2, 2026, at 12:00 PM CDT.
Commodities & Services Acquisition Service (36C791)

POSTED

about 13 hours ago

DEADLINE

in 3 days
NAICS: 334510
New
Federal
Hearing Aid Fitting and Verification for Shiprock Service Unit (IEE or ISBEE Set Aside)
Solicitation # SS-SRSU-27-0003
The Indian Health Service Shiprock Service Unit is conducting market research through a sources sought notice to identify capable Indian-owned economic enterprises, both large and small, to provide hearing aid fitting and verification services. The primary objective is to reduce hearing aid rejection and costly remakes while ensuring patients receive optimal benefits. The requirement includes the provision of equipment with dual ear capability, a comprehensive test suite featuring speechmap counseling and pediatric probe tube placement, and high accuracy measurements. Technical specifications call for a frequency range of 200 to 16,000 Hz, a dynamic range up to 140 dB SPL, and a 12.1 inch LED backlit display. Additionally, the selected vendor must provide installation and training for the Audiology Department. This opportunity is categorized under NAICS code 334510 for electronic hearing aid manufacturing, with a small business size standard of 1,250 employees. In accordance with the Buy Indian Act, the government will prioritize responses from Indian-owned economic enterprises before considering other small business set-aside programs. Interested parties must be registered in the System for Award Management and submit a company profile, a capability statement, and a completed IHS IEE Representation Form by November 03, 2026. This notice is for market research purposes only and does not constitute a formal solicitation.
Navajo Area Indian Health Svc

POSTED

3 days ago

DEADLINE

in 4 days

General Info

NAICS

334510 - Electromedical and Electrotherapeutic Apparatus Manufacturing

Place of Performance

VA San Francisco Health Care System San Francisco VA Medical Center 4150 Clement Street, San Francisco, CA, 94121-1545, USA

Set-Aside

NONE

Documents

1
DOCX

AI Contract Breakdown

Uniform Contract Format

Contract not broken down yet

CLEATUS splits the solicitation into Uniform Contract Format (UCF) sections: scope, pricing, deliverables, and evaluation criteria.

Timeline

PhaseClosed
Posted

Presolicitation

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Get full access to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Veterans Affairs → 261-NETWORK Contract Office 21 (36C261)
Contacts1 person available
OfficeMATHER, CA, 95655, USA
Office AddressMATHER, CA, 95655, USA
Contacts
Brian K. FritzContract Specialist

Full Description

Show more
This is a notice of intent to sole source a contract under the authority of FAR 13.106-1(b)(2), only one source being available to meet the Government s need. The contract will be to purchase one each Karl Storz Photodynamic Diagnosis System, Blue Light Cystoscopy Tower, with Cysview. The North American Industrial Classification System (NAICS) code for this procurement is 334510 Electromedical diagnostic equipment manufacturing, with a small business size standard of 1,250 employees. The FSC/PSC is 6515 Medical and Surgical Instruments, Equipment, and Supplies. The Department of Veterans Affairs intends to solicit and award a sole source contract for the purchase one each Karl Storz Photodynamic Diagnosis System, Blue Light Cystoscopy Tower, with Cysview to Karl Storz Endoscopy-America, Inc., 2151 E. Grand Avenue, El Segundo, CA 90245. There are no other source of supply/service that will satisfy agency requirements. The Karl Storz Photodynamic Diagnosis System is to be used by: VA Northern California Healthcare System San Francisco VA Medical Center 4150 Clement Street San Francisco, CA 94121-1545 This product is used for detection of bladder cancer tumors in Urology surgical procedures. Each photodynamic diagnosis system must include: Two mode light source for white and blue light An excitation filter must be mounted on a filter wheel that allows for rapid switching between white and blue light modes. Tricam pendulum camera head with high light transmission chip Tricam standard camera head with high light transmission chip Cable, fluid light, 2mm x 220cm PDD telescopes with angles: 12 degrees, 30 degrees, and 70 degrees Telescopes must provide contrast between fluorescing and non-fluorescing tissue Optical short jaw biopsy forceps, double action jaws for 70 degree lateral scopes Video cart with full door, and 4 shelves Must have a medical grade printer for use with DVD-M, HD connect and ICM Must have USB digital connections Two-pedal footswitch with button for switchover function for use with generator Bipolar high frequency cord Must have HD connect with DVD and Smart Screen for Urology 26 screen protector Visual and deflecting sheaths for visual obturator Must be compatible with Karl Storz Photodynamic Diagnosis System, accessories and Cysview technology. The VA San Francisco Health Care System, San Francisco VA Medical Center seeks to purchase the following components which comprise the Karl Storz Photodynamic Diagnosis System: ITEM INFORMATION ITEM NUMBER DESCRIPTION OF SUPPLIES/SERVICES QUANTITY UNIT 0001 1.00 EA 27" 4K 12G LED MONITOR,16:9 ASPECT RATIO W/ HDMI 2.0, 12G-SDI,AND DISPLAYPORT 1.2 The kit part number is composed of the following products: XUSM0003 27" 4K 12G LED MONITOR,16:9 ASPECT RATIO W/ HDMI 2.0, 12G-SDI,AND DISPLAYPORT 1.2 * Manufacturer's Warranty - 2 years LOCAL STOCK NUMBER: XUSM0003-UG 0002 1.00 EA TELECAM SL II FI SCB CCU F/FLEXIBLE PDD ONLY, NTSC, CE, INCLUDES KEYBOARD LOCAL STOCK NUMBER: 20213011U1 0003 1.00 EA KARL STORZ D-LIGHT C HIGH POWER LIGHT UNIT F/PDD, WITH 300 WATT XENON BULB * Manufacturer's Warranty - 1 year LOCAL STOCK NUMBER: 20133620-134 0004 1.00 EA UP210 ENDOMAT SELECT UNIT W/ DIRECT SUCTION TUBING PACKS The kit part number is composed of the following products: UP210 ENDOMAT SELECT, W/ INTEGRATED SCB MODULE SUCTION AND IRRIGATION PUMP * Manufacturer's Warranty - 2 years LOCAL STOCK NUMBER: UP210-URO-KT1 0005 1.00 EA UROLOGY-SOFTWARE, LICENSE FOR USE WITH UP210 ENDOMATr SELECT Requires Purchase of UP210 Endomatr Select LOCAL STOCK NUMBER: UP604 0006 2.00 EA AIDA BELLA W/SMARTSCREEN AND SOFTWARE LICENSE FOR UPDATES AND UPGRADES "Connection to StreamConnect requires labor and/or licensing quoted separately" The kit part number is composed of the following products: WD300 AIDA DOCUMENTATION SYSTEM 4K AND HD * Manufacturer's Warranty - 2 years WM200 OR1 SMARTSCREEN FOR WD300 AIDA BELLA * Manufacturer's Warranty - 2 years WD10025 AIDA BELLA SOFTWARE LICENSE USB CYBERSECURITY UPDATES, V1.6.2 * Manufacturer's Warranty - 1 year 20040241US SILICONE KEYBOARD WITH US CHARACTERS USB PLUG, FOR USE WITH IMAGE1S&TELEPACK * Manufacturer's Warranty - 1 year LOCAL STOCK NUMBER: WD350-KT-UG 0007 1.00 EA DUAL CHANNEL HD CAPTURE KIT FOR USE WITH AIDA BELLA 4K SYSTEM The kit part number is composed of the following products: WU1339 HDMI TO DISPLAYPORT ACTIVE CONVERTER SUPPORT HD RESOLUTION, 1080P (DVI) * Manufacturer's Warranty - 1 year WU1340 USB TO 5.5MM POWER CABLE, 3FT, 5V DC FOR USE WITH WU1339, TYPE M BARREL * Manufacturer's Warranty - 1 year 1149995 CABLE ASSY, DisplayPort, LCH, 30AWG, 3.0m * Manufacturer's Warranty - 1 year WU1336 CABLE, HDMI TO DVI, 6IN * Manufacturer's Warranty - 1 year LOCAL STOCK NUMBER: WD350-CBL-KT2 0008 2.00 EA SONY UP-DR80MD MEDICAL GRADE PRINTER FOR USE W/USB AND WIRELESS PRINTING The kit part number is composed of the following products: WU1333 SONY UP-DR80MD MEDICAL GRADE PRINTER FOR USE W/USB + OPTIONAL WIRELESS PRINT * Manufacturer's Warranty - 1 year LOCAL STOCK NUMBER: WU1333-UG 0009 1.00 EA COMPACT ENDOSCOPY CART W/ DRAWER,KEYBOAR TRAY AND ISOLATION TRANSFORMER, UG The kit part number is composed of the following products: XUSM0001 COMPACT ENDOSCOPY CART W/DRAWER, KEYBOARD TRAY, AND ISOLATION TRANSFORMER * Manufacturer's Warranty - 2 years LOCAL STOCK NUMBER: XUSM0001-UG 0010 1.00 EA IV POLE ASSEMBLY, FOR XUSM0001/XUSM0013 W/8.5 INCH EXTENSION ARM,UG The kit part number is composed of the following products: XUSM0001-4 IV POLE ASSEMBLY, FOR XUSM0001/XUSM0013 IV POLE ASSEMBLY WITH 8.5# EXTENSION ARM * Manufacturer's Warranty - 90 days LOCAL STOCK NUMBER: XUSM0001-4-UG 0011 2.00 EA ANALOG TO DIGITAL (DVI) SCALER/CABLE KIT FOR USE WITH AIDA BELLA 4K SYSTEM The kit part number is composed of the following products: WU1334 CONVERTER, ANALOG TO DIGITAL, DVI OUT FOR USE WITH AIDA BELLA 4K SYSTEM * Manufacturer's Warranty - 1 year WU1335 REMOTE FOR ANALOG TO DIGITAL SCALER FOR USE WITH AIDA BELLA 4K SYSTEM * Manufacturer's Warranty - 1 year LOCAL STOCK NUMBER: WD350-CBL-KT5-UG 0012 4.00 EA VIDEO CABLE TO CONNECT VIDEOENDOSCOPE WITH TELECAM DXII OR TELEPACK The kit part number is composed of the following products: 20213070 VIDEO CABLE TO CONNECT VIDEOENDOSCOPE WITH TELECAM DXII OR TELEPACK * Manufacturer's Warranty - 1 year LOCAL STOCK NUMBER: 20213070-UG 0013 2.00 PG SUCTION TUBING SET FOR ENDOMAT LC 10/PKG, STERILE * Manufacturer's Warranty - 90 days LOCAL STOCK NUMBER: 031247-10 0014 4.00 EA PDD FLEX VIDEO CYSTOSCOPE, 16FR X 37CM CHNL:6.5FR, REV DEFLECTION:210?U/140?D * Manufacturer's Warranty - 1 year LOCAL STOCK NUMBER: 11272VNIAK 0015 4.00 EA FORCEPS UNIT, WITH LUER TWO-WAY STOPCOCK * Manufacturer's Warranty - 1 year LOCAL STOCK NUMBER: 11272AZK 0016 8.00 EA LUER-LOCK CONNECTOR WITH STOPCOCK * Manufacturer's Warranty - 1 year LOCAL STOCK NUMBER: 27502 0017 4.00 EA VALVE INTAKE, AUTOCLAVABLE * Manufacturer's Warranty - 1 year LOCAL STOCK NUMBER: 11900VA 0018 4.00 EA SUCTION VALVE FOR VIDEO CYSTOSCOPES F/USE W/11272VNIA & 11272VNIUA * Manufacturer's Warranty - 1 year LOCAL STOCK NUMBER: 27100MV 0019 4.00 PG CONNECTING TUBE, F/USE W/11272VNIA & 11272VNIUA, 10/PKG, SINGLE USE * Manufacturer's Warranty - 90 days LOCAL STOCK NUMBER: 27100MS 0020 4.00 EA MONOPOLAR COAGULATING ELECTRODE, 4FR X 73CM, UNSTERILE * Manufacturer's Warranty - 90 days LOCAL STOCK NUMBER: 27723T 0021 4.00 EA UNIVERSAL STERILIZATION CONTAINER FOR CCD VIDEOENDOSCOPES The kit part number is composed of the following products: KSZ-39403AS CONTAINER SYSTEM, FLEX CCD VIDEOSCOPES DM: 23.5"L X 11"W X 4"H * Manufacturer's Warranty - 90 days LOCAL STOCK NUMBER: KSZ-39403AS-ZBZ 0022 4.00 EA FLEXIBLE GRASPING FORCEPS F/LARGE STONES + FRAGMENTS, DBL ACTION JAWS, 5FR X 60CM * Manufacturer's Warranty - 1 year LOCAL STOCK NUMBER: 27425PG 0023 4.00 EA PEREZ-CASTRO FLEXIBLE FORCEPS FOR STEINSTRASSE, LONG DBL ACTION JAWS, 5FRX60CM * Manufacturer's Warranty - 1 year LOCAL STOCK NUMBER: 27425RG 0024 4.00 EA FLEXIBLE BIOPSY FORCEPS, DOUBLE ACTION JAWS, 5FR X 60CM * Manufacturer's Warranty - 1 year LOCAL STOCK NUMBER: 27425ZG 0025 1.00 EA MONOPOLAR HIGH FREQUENCY CORD W/8MM PLUG F/COVIDIEN ELECTROSURGICAL UNITS, 300CM The kit part number is composed of the following products: 26006M MONOPOLAR HIGH FREQUENCY CORD W/8MM PLUG F/COVIDIEN ELECTROSURGICAL UNITS, 300CM * Manufacturer's Warranty - 90 days LOCAL STOCK NUMBER: 26006M-UG 0026 2.00 EA ADJUSTABLE SHELF, FOR XUSM0001 * Manufacturer's Warranty - 90 days LOCAL STOCK NUMBER: XUSM0001-1 0027 1.00 EA 32" 4K UHD LED MONITOR,16:9 ASPECT RATIO W/HDMI,12G-SDI,AND DP 1.2, UG The kit part number is composed of the following products: TM343 32" 4K UHD LED MONITOR,16:9 ASPECT RATIO W/HDMI,12G-SDI,AND DP 1.2 * Manufacturer's Warranty - 2 years LOCAL STOCK NUMBER: TM343-UG 0028 1.00 EA IMAGE1 S SAPHIRA CCU & LIGHT SOURC INTRO PROMOTION The kit part number is composed of the following products: TC205US IMAGE1 S# SAPHIRA CONNECT II,CONNECT MODULE,FOR USE WITH TC305US LINK MODULE * Manufacturer's Warranty - 2 years TC305US IMAGE1 S# SAPHIRA LINK, LINK MODULE, FOR USE W/ ONE-CHIP CAMERA HEAD TH113US * Manufacturer's Warranty - 2 years TL410US POWER LED SAPHIRA#, OPAL1r PDD, COLD LIGHT FOUNTAIN POWER LED SAPHIRA# * Manufacturer's Warranty - 1 year 20040241US SILICONE KEYBOARD WITH US CHARACTERS USB PLUG, FOR USE WITH IMAGE1S&TELEPACK * Manufacturer's Warranty - 1 year TC009 ADAPTER, USB TO ACC FOR AIDA CONTROL INCLUDES ACCESSORY CABLES * Manufacturer's Warranty - 1 year LOCAL STOCK NUMBER: P-SAPHIRA 0029 1.00 EA SMARTSCREEN REMOTE CABLE KIT FOR USE WITH AIDA BELLA 4K SYSTEM The kit part number is composed of the following products: 20090179 USB CONNECTING CABLE FOR AUDIO CONNECT USED WITH SPEECH CONTROL VOICE1r NEO * Manufacturer's Warranty - 1 year WA1000C DIPLAYPORT 1.2 CABLE FOR 4K VIDEO 6FT 6FT LENGTH, SUPPORTS 60 FPS * Manufacturer's Warranty - 1 year WM20001 POWER SUPPLY FOR WM200 SMARTSCREEN * Manufacturer's Warranty - 1 year LOCAL STOCK NUMBER: WD350-CBL-KT3 0030 3.00 EA HOPKINS II 30? PDD TELESCOPE WITH ENLARGED VIEW, 4MM X 30CM, AUTOCLAVABLE * Manufacturer's Warranty - 3 years LOCAL STOCK NUMBER: 27005BIA 0031 1.00 EA SLIM DESIGN SURGICAL CART W/OPEN SIDES UG, KIT WITH CO2 TANK HOLDER XUSM0008 The kit part number is composed of the following products: UG130U SLIM DESIGN SURGICAL CART W/OPEN SIDES * Manufacturer's Warranty - 2 years XUSM0008 CO2 TANK HOLDER FOR UG130U COR CART * Manufacturer's Warranty - 90 days LOCAL STOCK NUMBER: UG130U-KT-UG 0032 5.00 EA LIGHT CABLE, 3.5MM X 230CM (7.6') AUTOCLAVABLE, WITH LOCKING MECHANISM The kit part number is composed of the following products: 495NAC LIGHT CABLE, 3.5MM X 230CM (7.6') AUTOCLAVABLE, WITH LOCKING MECHANISM * Manufacturer's Warranty - 1 year LOCAL STOCK NUMBER: 495NAC-UG 0033 3.00 EA IMAGE1 S HX-P SAPHIRA, INTRO PROMOTION The kit part number is composed of the following products: TH113US IMAGE1 S# HX-P SAPHIRA ONE-CHIP FULL HD PENDULUM CAMERA HEAD, FOR USE W/ TC305US * Manufacturer's Warranty - 2 years LOCAL STOCK NUMBER: P-SAPHIRA-HEAD 0034 4.00 EA UNIVERSAL STERILIZATION CONTAINER FOR CCD VIDEOENDOSCOPES The kit part number is composed of the following products: KSZ-39403AS CONTAINER SYSTEM, FLEX CCD VIDEOSCOPES DM: 23.5"L X 11"W X 4"H * Manufacturer's Warranty - 90 days LOCAL STOCK NUMBER: KSZ-39403AS-ZBZ 0035 1.00 PG STERITITE POLYPRO FILTERS FOR CONTAINERS 7.5" RND,F/STERRAD,(1000/PKG),DISPOSABLE The kit part number is composed of the following products: KSZ-SCF02 STERITITE POLYPRO FILTERS FOR CONTAINERS 7.5" RND,F/STERRAD,(1000/PKG),DISPOSABLE * Manufacturer's Warranty - 90 days LOCAL STOCK NUMBER: KSZ-SCF02-ZBZ 0036 1.00 PG PRESSURE CONTROLLED TUBING, SINGLE USE FOR ENDOMATr SELECT, STERILE, PKG. 10 The kit part number is composed of the following products: 031523-10 PRESSURE CONTROLLED TUBING, SINGLE USE FOR ENDOMAT SELECT, STERILE, PKG. 10 * Manufacturer's Warranty - 90 days LOCAL STOCK NUMBER: 031523-10-URO 0037 1.00 EA BIPOLAR HIGH FREQUENCY CORD, 400CM FOR KARL STORZ UH400U, SCB * Manufacturer's Warranty - 90 days LOCAL STOCK NUMBER: UH801 0038 1.00 EA BIPOLAR WORKING ELEMENT ONLY WITH SPRING ACTION AND MOVABLE THUMB SUPPORT * Manufacturer's Warranty - 1 year LOCAL STOCK NUMBER: 27040EB 0039 1.00 EA HOPKINS II 70? PDD TELESCOPE WITH ENLARGED VIEW, 4MM X 30CM, AUTOCLAVABLE * Manufacturer's Warranty - 3 years LOCAL STOCK NUMBER: 27005CIA 0040 5.00 EA FLUID LIGHT CABLE, 2MM X 220CM (7.2') The kit part number is composed of the following products: 495FS FLUID LIGHT CABLE, 2MM X 220CM (7.2') * Manufacturer's Warranty - 1 year LOCAL STOCK NUMBER: 495FS-UG Any responsible source that feels it is capable in performing this requirement may submit a quote (monthly per scope) for the above listed items and describe and/or submit documentation to support your capabilities. The response will be considered by the agency. If you are not the Original Equipment Manufacturer (OEM), you must submit an authorized distributor letter signed by the OEM. If you are not the OEM and a small business, you must indicate in your response how you will comply with limitations on subcontracting and/or the non-manufacturer rule. Responses should be submitted to Brian K. Fritz at contact@example.gov no later than December 2, 2022 at 10:00 AM Pacific Time to be considered. If no responses are received, the Government will continue with its sole source procurement, and a sole source Request for Quote will be published to contract opportunities in accordance with FAR 5.102.

More opportunities from Department Of Veterans Affairs → 261-NETWORK Contract Office 21 (36C261)

Same awarding agency

NAICS: 238220
New
Federal
J041--2nd Floor HVAC Duct Repairs VA Central California Healthcare System
Solicitation # 36C26127Q0127
The Department of Veterans Affairs, through Network Contracting Office 21, has issued a sources sought announcement for HVAC duct repair services on the second floor of the Fresno VA Campus in California. This market research effort seeks to identify capable contractors under NAICS code 238220. The scope of work includes replacing flex ducts and fan coil unit belts, demolishing and relocating spiral ducts and registers, sealing leaking VAVs to ensure proper airflow, and installing new registers in specific offices. The project must be completed within four weeks of contract award, with work performed during normal business hours of 8:00 am to 4:30 pm, Monday through Friday. Interested respondents must provide a capabilities statement including their socioeconomic status, SAM Unique Entity ID, and evidence of experience with similar government or commercial projects. A completed informational price estimate for the specific line items is required to help the government determine its procurement strategy. Contractors must adhere to strict safety and technical standards, including OSHA 29 CFR 1910 and 1926, NFPA codes, and Health Care System Memorandums. Additionally, small businesses, including SDVOSBs and VOSBs, must comply with FAR 52.219-14 and 52.219-27, ensuring at least 50 percent of the cost of contract performance for personnel is expended for employees of the concern.
Plumbing, Heating, and Air-Conditioning Contractors

POSTED

about 13 hours ago

DEADLINE

in 5 days
View Details
NAICS: 811210
New
Federal
VAPAHCS Communication Maintenance Services
Solicitation # 36C26126Q1224
Solicitation 36C26126Q1224 is a request for quotation issued by the Department of Veterans Affairs Network Contracting Office 21 for the maintenance and repair of the Motorola Astro Core P25 equipment at the VA Palo Alto Health Care System Police dispatch center. This non-personal services contract is a set-aside for Service-Disabled Veteran-Owned Small Businesses (SDVOSB) and covers a base period of performance from December 1, 2026, to November 30, 2027, with an option to extend services for up to six months. The scope of work includes regular and emergency maintenance across locations in Palo Alto, Livermore, and Menlo Park, requiring a three-hour emergency callback response. The contractor must provide all labor, parts, and tools while adhering to NFPA 70E, NFPA 99, and OSHA 29 CFR 1910 safety standards. Award will be based on the best value, evaluating technical capability, past performance, and price. Technical requirements include Motorola authorization, proof of enrollment in the Motorola Customer Plan, and specific familiarity with Astro 25 Simplified Core and Virtualized Prime/DSC 8000 systems. Performance will be monitored via a Quality Assurance Surveillance Plan using a pass/fail rating system. Contractors must comply with strict personnel vetting, including Tier 1 low-risk background investigations and PIV card requirements. Financial terms specify electronic invoicing through Tungsten and adherence to Service Contract Act wage determinations for San Francisco, San Mateo, and Santa Clara counties.
Electronic and Precision Equipment Repair and Maintenance

POSTED

about 13 hours ago

DEADLINE

in 5 days
View Details
NAICS: 541380
New
Federal
VACCHCS Pharmacy Certification
Solicitation # 36C26127Q0099
The Department of Veterans Affairs Network Contracting Office 21 is soliciting quotes for semi-annual pharmacy certification testing for the VA Central California Healthcare System in Fresno, California. The contract covers a base period from February 5, 2027, to February 4, 2028, with four subsequent one-year option periods ending February 4, 2032. The scope of work requires CETA certified technicians to perform testing every six months, typically in August and February, to ensure compliance with USP 795, 797, and 800 standards, as well as VHA Directives and ISO standards. Performance locations include Building 1 and Building 24, with specific requirements for laminar flow clean benches, particle counts, airflow studies, and terminal air filter testing. Award will be based on the most advantageous offer, evaluating technical capability, past performance, and price. Technical requirements include providing active CETA certification for at least two employees, evidence of technicians located within a 250-mile radius of the facility, and three examples of relevant USP certification experience within the last five years. The contract is unrestricted and falls under NAICS code 541380. Contractors must adhere to a Quality Assurance Surveillance Plan requiring 100 percent compliance with VA directives and reporting accuracy. Invoicing is handled monthly in arrears via the Tungsten network, and the contractor is responsible for providing all necessary equipment.
Testing Laboratories and Services

POSTED

about 13 hours ago

DEADLINE

in 3 days
View Details
NAICS: 811310
New
Federal
J012--FIRE DAMPER REPAIR SERVICES VA Central California Healthcare System
Solicitation # 36C26127Q0138
The Department of Veterans Affairs Central California Healthcare System is issuing a sources sought announcement for fire damper repair and re-certification services at its Fresno, California facility. The scope of work involves performing necessary repairs to ensure fire dampers are operational and compliant, which includes repairing pneumatic lines to ensure actuators receive proper air pressure. The contractor must provide all necessary tools, materials, and personnel, adhering to strict safety and fire codes including NFPA 90A, 80, 105, 70, 70E, 72, 92, and 99, as well as OSHA and EPA standards. Key deliverables include a safety plan and chemical Safety Data Sheets submitted to the Contracting Officer's Representative within 15 days of award, and a 30-day warranty on all labor and components. The project is expected to be completed within 60 days of the notice to proceed, with work typically performed Monday through Friday from 8:00 am to 4:30 pm. This announcement is used to determine the procurement strategy and requires interested firms to submit a capability statement, socioeconomic status, and price estimates for specific materials such as Belimo actuators and various damper access doors. The applicable NAICS code is 811310, with a small business size standard of 12.5 million dollars. Responses must be submitted via email to the contract specialist by November 4, 2026.
Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance

POSTED

about 13 hours ago

DEADLINE

in 5 days
View Details
NAICS: 812210
New
Federal
Mortuary Services at VA Palo Alto Healthcare System
Solicitation # 36C26126Q0775-2
The Department of Veterans Affairs Network Contracting Office 21 is seeking sources for mortuary services to handle unclaimed or indigent Veteran remains for the VA Palo Alto Healthcare System. The contractor will be responsible for providing all professional funeral services, including body preparation, refrigeration, transport, and storage, moving remains from VA facilities to National or VA grant-funded State Veterans Cemeteries in Seaside or Gustine, California. The contractor must be located within a 25-mile radius of the Palo Alto facility and respond to removal requests within one business day. The anticipated period of performance consists of a base year beginning December 31, 2026, with four subsequent option years. Compliance requirements include adherence to VHA Directive 1601B.04, California Board of Funeral Directors and Embalmers licensing, and various federal and state health and safety codes. Contractors must maintain workers compensation, professional liability insurance, and specific identity theft insurance. Performance will be monitored by a Contracting Officer Representative through a Quality Assurance Surveillance Plan and on-site inspections. This is currently a sources sought announcement under NAICS code 812210, requiring interested parties to submit a capabilities statement, evidence of experience, a subcontracting plan, and an informational price estimate. Small businesses must comply with limitations on subcontracting, ensuring at least 50 percent of personnel costs are expended for their own employees.
Funeral Homes and Funeral Services

POSTED

about 13 hours ago

DEADLINE

in 7 days
View Details

Earlier notices in this NAICS code

Posted before this notice, open and closed

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS