This Sources Sought opportunity from Department Of Veterans Affairs was posted on March 19, 2026. The submission period has ended. Browse the details below for market research, or find similar active opportunities.
6515--PHYSIOLOGIC MONITOR MODULES: EEG (SEDATION MONITOR) (VA-26-00042266)
Contract Overview
Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.
Active Opportunities Like This One
General Info
Place of Performance
NATIONWIDE, MD, USASet-Aside
Documents
1AI Contract Breakdown
Uniform Contract FormatSign up to view the full breakdown with detailed analysis of each section.
View Full BreakdownThis one is closed. Find the next one like it.
Open contracts like this one, right now:
- Orthopedic Heel Cup (Latex Rubber) SupplyOpen now, due in 7 days
- Medical Burn Dressing SupplyOpen now, due in 7 days
Ask CLEATUS
I've read this contract. Ask me anything.
Timeline
Submission Closed
Organization & Contact Information
Full Description
The Department of Veterans Affairs (VA) is seeking vendors who can provide Masimo SedLine® as listed below which meet all the following Salient Characteristics (SC). CLINs 0001 0003 apply to the following: SC# Salient Characteristics Method of Evaluation Literature Mapping SC 1 System must provide processed Electroencephalogram (EEG) Index Literature Brochure, Brain Monitoring Differentiation, US (PLM-11917C ) (2) Page 3 SC 2 System must provide four channels of continuous raw EEG Literature Brochure, Next Generation SedLine (PS-60586) (PLM-11107B) (2) Page 4 SC 3 System must provide bilateral Density Spectral Array (DSA) Literature Brochure, Next Generation SedLine (PS-60586) (PLM-11107B) (2) Page 1 SC 4 The system must provide and display the following monitoring parameters on a single platform: SC#1 processed EEG index, SC#2 raw EEG, and SC#3 bilateral DSA Literature Brochure, Next Generation SedLine (PS-60586) (PLM-11107B) (2) Page 1
CLINs MANUFACTURERS PART NUMBERS DESCRIPTION BASE YEAR OPTION YEAR ONE OPTION YEAR TWO OPTION YEAR THREE OPTION YEAR FOUR 0001 Â Â Â 30 30 30 30 30 0002 Â Â Â 30 30 30 30 30 0003 Â Â Â 30 30 30 30 30
Design Design features and functions of the offered device will be evaluated for its ability to aid in the performance of its intended function. Areas include but are not limited to the following: Ability to integrate with other Surgical Equipment Probe functions/versatility Customization for various procedures (options) Irrigation options/availability Number and variety of input/outputs connection/ports for peripheral devices Types of procedures supported
Performance The Device will be evaluated for its ability to perform its intended function. Areas included but are not limited to: Touch Screen features and ease of use Workflow performance of complete system Types/modes of energy (above and beyond what is in the SCs) Power adjustability
Safety The device will be assessed for patient safety features, including, but not limited to, the following areas: Audible tones and visual alarms Contact monitoring data display
Quality/Service /Training Training - Availability and options Service - Terms and conditions Warranty Terms and conditions
Again, for each product (brand name and part number), the response must include descriptive literature demonstrating the product meets or exceeds the salient characteristics specified above. The Government's intent is to include all ancillary items to ensure the equipment can function as designed by the Original Equipment Manufacturer (OEM) and as clinically required. Vendors are encouraged to provide any product solution or configuration so long as they meet the salient characteristics. Additionally, responses can include any additional product that may be beneficial. These items must be clearly identified by brand name and part number. Responses to this Sources Sought Notice shall include the following: 1. Please provide a yes or no, with a brief point-by-point explanation of how your product can or cannot meet each draft salient characteristic, in a chart/table format. 2. Please provide OEM technical literature that clearly shows how your product meets each salient characteristic. Please ensure the OEM technical literature is properly mapped with respective page numbers so it is easy to reference and connect to the draft salient characteristics. Does vendor offer an annual service plan, Yes or No? 3. If Yes: What does the plan cover? Does plan cover software updates only? Does the plan cover parts repair or replacement only? Does the plan cover both software and parts? 4. Vendors are requested to provide documentation that shows information on their service plan. 5. Is the service provided by the OEM or a subcontractor? 6. Full name and address of company 7. DUNS number/ CAGE Code/ SAM UIE 8. Business Size 9. Manufacturer or Distributor: If distributor - provide full name, business size and address of manufacturer. 10. Country of Origin designation for all products 11. Ability to provide uninterrupted supply of products on a national scale. 12. Technical Literature that clearly shows product(s) meets the identified salient characteristics and page numbers where each salient characteristic is met. 13. Any additional product solution or configuration that would be beneficial to the clinical functionality of the product line identified. 14. Authorized Distributor Letter Certified by OEM with a current date. Although not required, vendors responding to this Sources Sought may also submit a Capabilities Statement.
More opportunities from Department Of Veterans Affairs → Sac Frederick (36C10X)
Same awarding agency
Find Active Opportunities Like This
Get AI-powered intelligence on the opportunities still open
Every page of the solicitation package shredded into a compliance breakdown
AI-powered matching based on your capabilities and past performance
Competitor and incumbent history on the requirement
Automated alerts on amendments, Q&A deadlines, and award
Join 750+ contractors already using CLEATUS
