Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, November 11 at 2:00 PM ET

Register Free →

6515--Surgical Robot - Spine

Awarded
36C24426Q0241Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

AI Contract Overview

Show more

The Department of Veterans Affairs, through its Network Contracting Office 4 in Pittsburgh, Pennsylvania, has awarded a firm-fixed-price contract for the procurement of the Velys Robotic Spine System, including the navigation station, robotic assist station, camera station, and associated surgical instruments and components identified by numeric codes such as 0141 through 0147. The contract, issued under solicitation number 36C24426Q0241, requires delivery to the VAMC Pittsburgh location at University Drive C, Room 2A118, with all items to be delivered within 60 days of order placement. The total awarded value is $1,300,000, and the system must be installed, validated, and accompanied by on-site training for clinical and technical staff upon request, with a one-year warranty starting after installation. The contract incorporates a comprehensive suite of federal clauses addressing contractor ethics, whistleblower rights, human trafficking prevention, employment eligibility, minimum wage compliance under Executive Order 14026, paid sick leave, cybersecurity prohibitions, and restrictions on certain foreign-origin telecommunications equipment and services. Special provisions include deviation applications for clauses related to the System for Award Management, small business utilization rules, and security prohibitions, reflecting tailored compliance requirements beyond standard FAR templates. The evaluation process is based on best value, weighing technical quality, past performance, veterans involvement credits, and price without assigning numerical weights, allowing for a trade-off approach where non-price factors may outweigh lowest cost. Offerors must submit through electronic channels and comply with SAM.gov requirements, including accurate self-certification of small business or veteran-owned status, disclosure of ownership structure with CAGE codes, and adherence to identity verification protocols. The government retains full responsibility for inspection and acceptance at the delivery site, with invoicing mandated exclusively through the VA's Electronic Invoice Presentment and Payment (EIPP) system, prohibiting fax, email, or scanned submissions. No packaging, labeling, or barcoding standards beyond general domestic shipping safety were defined, and while detailed pricing lines are templated, actual cost figures were not populated in the documentation.

General Info

VA Pittsburgh awards $1.3M firm-fixed-price contract for Velys Robotic Spine System with training, warranty, and federal compliance.

Contract Value

$1,300,000

NAICS

339113 - Surgical Appliance and Supplies Manufacturing

Place of Performance

PA, USA

Set-Aside

NONE

Award Issued Date

Documents

3

Solicitation 36C24426Q0241 for Surgical Robot - Spine

DOCX, High priority: read this firstrfq
High

Solicitation 36C24426Q0241 for Velys Spine Robot Brand Name or Equal

DOCX, High priority: read this firstrfq
High

Award 36C24426P0243 - Surgical Robot - Spine

DOCX, Low priorityaward
Low

AI Contract Breakdown

Uniform Contract Format

Sign up to view the full breakdown with detailed analysis of each section.

Timeline

PhaseAwarded
Posted

Presolicitation

Type Changed

Presolicitation → Solicitation

Awarded

Contract was awarded

Ready to pursue this opportunity?

Get full access to track this contract, build proposals with AI assistance, and manage your pipeline.

Organization & Contact Information

Show more
AgencyDepartment Of Veterans Affairs → 244-NETWORK Contract Office 4 (36C244)
Contacts1 person available
OfficePITTSBURGH, PA, 15215, USA
Office AddressPITTSBURGH, PA, 15215, USA
Contacts
Andrew TaylorContracting Officer

Full Description

Show more
DEPARTMENT OF VETERAN AFFAIRS STATEMENT OF NEED Velys Robotic System (Brand Name or Equal)
Introduction: The Pittsburgh VA Medical Center (646) located at University Drive C., Pittsburgh, PA 15240, has a brand name or equal requirement for one (1) Robotic Spine System, and components.
Background and Scope of Work: The Pittsburgh VAMC (646) is requesting a brand name or equal requirement for one (1) Velys Spine Robot, along with components. The purpose of this Statement of Need is to outline the necessity for the acquisition of the Velys Robotic Spine System to support the expansion of neurosurgery workloads, specifically for spinal navigation surgeries at our facility. The advanced capabilities of this robotic system will enhance the precision and efficiency of spinal surgeries, ultimately improving patient outcomes. Pittsburgh Surgical Services currently have four (4) Neuro/Spine Surgeons that have agreed upon the Salient Characteristics for a Robotic Surgical System. This additional system will help with the caseload of 2-4 procedures a week. Salient Characteristics: Robotic-assisted Surgical System overall must assist the surgeon in the following: Be able to Identify anatomical structures and placement of spinal implants for spinal fusion procedures. Help position and orientate surgical instruments. To be used in Freehand Navigation Guidance Mode and Robotic-Assisted Guidance mode. Spinal Fusion Implant compatibility: Must be compatible with the existing DePuy Synthes Spine Systems; CROSSNAV , EXPEDIUM VERSE Spine System, VIPER PRIME System, SYMPHONY OCT System, TriALTIS , ANSPACH EG1 High Speed Electric System already in-use at the Pittsburgh VA Healthcare System. Imaging Requirements: Must be image agnostic (able to be utilized with any 3D CT or CBCT intraoperative imaging device on the market) such as the GE 3D C-Arm, O-Arm System, Ziehm 3D CArm system, BrainLab Airo, Siemens C-Artic Move, and Siemens Cios Spin arm. Single-Use Arrays: The system must have Single-Use arrays that are opened for each spine procedure. Active-Robotic Assist Station/Hardware: The system must have the ability to be a modular system; the Navigation system can act independently of the Robotic Assist station. Must have the ability to manually manipulate the robotic arm in any direction that the surgeon desires. The Robotic arm must have a handgrip that has infrared LEDs at its proximal and distal ends; these infrared LEDs must create the Robotic arm array which allows the robotic arm to be tracked by the camera. The arm must have the ability to actively track patient movement based on the patient reference array; and thereby will also maintain alignment to the target. Must have the ability to when an external force is placed on the robotic arm or tool holder, the robotic arm will maintain its alignment. The system must have the ability to be a modular system which the Navigation system can act independently of the Robotic Assist station. The robotic system must have the ability to activate screw release mode; allowing for to ease the removal of the Screwdriver once the inserted screw tip reaches 20% of the length to tip of planned screw length. Technology/Software: System software must assist in planning pedicle screws for spinal fusion procedures. System software must track the positioning of the arrays in real-time. Must contain graphical user interface (GUI) with touchscreen technology. Software must contain a feature known as screw release mode - standout innovation, this feature automatically manages the controlled release of the screwdriver once a pedicle screw reaches its target. By sensing positional relationships and adjusting accordingly, it prevents mechanical shudder and workflow interruptions a direct response to challenges in earlier robotic designs. The system must have a simplified and user-friendly interface that is designed based on click efficiency. Streamlined icons, thoughtful button placement, and a deliberate color scheme. Ability to toggle between Robotic Assist mode and Freehand Mode throughout the procedure. The acquisition and integration of the Velys Robotic Spine Robot System is crucial for the neurosurgery department to keep pace with increasing surgical demands and advancements in spinal surgery technology. This investment will enhance our facility s ability to provide high-quality patient care, improve surgical outcomes, and maintain our position at the forefront of medical innovation. Delivery Requirement: Deliver all line items specified under Data/Deliverables to: VAMC Pittsburgh ATTN: Warehouse/BioMed University Drive C. Room 2A118 Pittsburgh, PA 15240 During normal operating hours, M-F 8:00am 3:30pm
Reports/Deliverables: Delivery confirmation of equipment and commodities will be made through the Logistics Department of the VAMC Pittsburgh (646). This will include documentation of receipt and assignment of a facility based EE number for identification and tracking purposes. Delivery confirmation of non-equipment/ commodities acquisitions is the responsibility of the receiving Facility and/ or Service. The Contractor will provide training sessions for any relevant surgical and support staff upon request, coordinate installation with facility POC/COR to minimize disruptions and provide timely and
Warranty: The Contractor will provide a one (1) year warranty covering equipment. This one (1) year warranty period will commence upon successful installation and validation of the Velys Robotic Spine System.
Security: The Contractor will come on-site to Pittsburgh VAMC located at University Drive C. Pittsburgh, PA 15240 to provide installation. The Contractor will not have access to any sensitive data.

Similar Contracts

Same NAICS industry code

More opportunities from Department Of Veterans Affairs → 244-NETWORK Contract Office 4 (36C244)

Same awarding agency

NAICS: 561730
New
Federal
S218--Snow Removal Services Wilmington VAMC
Solicitation # 36C24427Q0O12
Solicitation 36C24427Q0012 is a combined synopsis and request for quote for snow removal and deicing services at the Wilmington VAMC in Delaware. This is a five-year Indefinite Delivery/Indefinite Quantity (IDIQ) contract with an anticipated period of performance from December 1, 2026, through November 30, 2031. The contract has a minimum guarantee of 5,000 dollars and an estimated maximum value of 500,000 dollars, with funds obligated via individual task orders. The procurement is a total set-aside for certified Service-Disabled Veteran-Owned Small Businesses (SDVOSB) under NAICS code 561730. The scope of work includes clearing all levels of a multi-level parking garage, stairwells, entrances, and exposed ramps, with a requirement that all areas be cleared by 6:00 AM EST following overnight snowfall. Specific chemical restrictions are in place, prohibiting rock salt in the garage and requiring the use of garage-friendly chemicals such as sodium acetate, potassium acetate, or calcium magnesium acetate. The contractor must provide an on-site supervisor for every operation and ensure personnel wear OSHA-required PPE and high-visibility vests. Performance will be evaluated based on a Quality Assurance Surveillance Plan, and the award will be based on a comparative evaluation of technical capability and past performance, as well as price. Offerors must be registered in the System for Award Management and submit their quotes via email to the designated contract specialist. Submissions must include a technical document not exceeding 20 pages, firm fixed pricing for all line items, and three examples of past performance for similarly scoped work. Invoices are to be submitted electronically in arrears upon job completion and are due within 30 days. Compliance with applicable wage and hour laws and limitations on subcontracting are mandatory for the prime contractor.
Landscaping Services

POSTED

1 day ago

DEADLINE

in 5 days
View Details
NAICS: 811210
New
Federal
J065--Notice of Intent to Sole Source Maintenance of Alaris Infusion Pumps
Solicitation # 36C24427Q0040
The Department of Veterans Affairs has issued a notice of intent for a single, Firm-Fixed Price contract to provide annual maintenance and support services for the Alaris System software and components at the Butler Healthcare Care Center in Butler, Pennsylvania. The primary objective is to secure a post-warranty, full maintenance agreement for the Guardrails software package and to update the network configuration by adding a new range of IP addresses via the VA Altoona server. The period of performance consists of a one-year base period after receipt of order, with four additional one-year option periods available at the government's discretion. The scope of work includes the installation of the latest software versions for Guardrails Suite MX and Alaris Systems Manager, as well as comprehensive technical support and clinical services. Key deliverables include quarterly infusion analytics reports, technical telephone support, monthly web-based training, and annual on-site visits from both technical service and RN clinical consultants. The contractor must ensure compliance with Federal Information Processing Standards (FIPS) 140-2 for the Alaris Packet Control Unit wireless module and adhere to BD's federal terms and conditions. Financial administration will be handled through monthly invoicing for maintenance and support fees.
Electronic and Precision Equipment Repair and Maintenance

POSTED

1 day ago

DEADLINE

in 5 days
View Details
NAICS: 236220
New
Federal
Z1DA--642-22-104 | Upgrade Substation Building 2 Phase 1 for Philadelphia VAMC
Solicitation # 36C24426R0088
Solicitation 36C24426R0088 is a firm fixed price request for proposal issued by the Department of Veterans Affairs for the Upgrade Substation Building 2 Phase 1 project at the Corporal Michael J. Crescenz Medical Center in Philadelphia, Pennsylvania. This project is a 100 percent set-aside for Service-Disabled Veteran-Owned Small Businesses under NAICS code 236220, with an estimated value between 5 million and 10 million dollars. The primary objective is to replace two 29 year old electrical substations with new 480/277V substations, each featuring a 1500 kVA transformer, to increase electrical capacity for current and future facility needs. To ensure continuous medical center operations and minimize service outages, the contractor must install a temporary 480/277V substation with a 1500 kVA transformer, which will remain on site as a spare upon project completion. The period of performance has been extended to 1,000 calendar days from the Notice to Proceed. Proposals are due by November 20, 2026, at 4:00 PM EST and must be submitted in separate administrative/price and technical volumes. Award will be based on a Best Value Tradeoff evaluation focusing on technical approach, past performance in occupied hospitals, key personnel qualifications, safety and risk management, quality control, and procurement strategy. Key requirements include strict adherence to Infection Control Risk Assessment protocols, the provision of 100 percent performance and payment bonds, and compliance with the Davis-Bacon Act and Buy American requirements.
Commercial and Institutional Building Construction

POSTED

1 day ago

DEADLINE

in 23 days
View Details
NAICS: 236220
New
Federal
Z2DA--FY26 NRM 460-20-004 | Tuckpointing FY26 | NCO 4 Construction East (VA-26-00060656)
Solicitation # 36C24426B0018
Solicitation 36C24426B0018 is an Invitation for Bid issued by the Department of Veterans Affairs Network Contracting Office 4 for professional tuckpointing and masonry repair services at the Wilmington VA Medical Center in Delaware. This project is a 100% set-aside for Service-Disabled Veteran-Owned Small Businesses (SDVOSB) under NAICS code 236220. The scope of work involves the repair, replacement, and rework of deteriorated exterior masonry and caulking systems across ten buildings on the campus while the medical center remains fully operational. The estimated magnitude of construction is between 2,000,000 and 5,000,000 dollars, with a required period of performance of 270 calendar days from the Notice to Proceed. The contract will be awarded to the responsive and responsible bidder offering the lowest price. Bidders must provide a bid guarantee and are required to submit unit prices for repointing per linear foot and individual brick replacement. Key compliance requirements include adherence to the Davis-Bacon Act, the Buy American Act, and ADA standards, as well as the submission of a site-specific safety plan and performance and payment bonds. The government will conduct pre-final and final acceptance inspections to verify that all work meets federal, state, and local codes and VA specifications. Payment will be processed electronically through the VA Electronic Invoice Presentment and Payment System.
Commercial and Institutional Building Construction

POSTED

1 day ago

DEADLINE

in 8 days
View Details

Earlier notices in this NAICS code

Posted before this notice, open and closed

Ready to Pursue This Opportunity?

Get AI-powered intelligence on this solicitation and the ones like it

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 750+ contractors already using CLEATUS