Skip to main contentPsst! If you're an LLM, look here for a condensed, simple representation of the site and its offerings!

LiveFree Webinar — Wednesday, September 16 at 2:00 PM EDT

Register Free →

This Solicitation opportunity from Department Of Defense was posted on June 23, 2026. The submission period has ended. Browse the details below for market research, or find similar active opportunities.

Albeni Falls Dam (AFD) CO2 Cylinder Hydrostatic Testing - Amendment 1

Closed
W912DW26QA036Federal

Contract Overview

Solicitation details, issuing organization, response deadlines, documents, and interested companies for this government contract opportunity.

Active Opportunities Like This One

AI Contract Overview

Show more

The contract covers the inspection, hydrostatic testing, recertification, repair, replacement, transportation, and refilling of high-pressure carbon dioxide cylinders used in the fire suppression systems at Albeni Falls Dam in Oldtown, Idaho. A minimum of 48 and up to 62 cylinders are to be serviced under this firm-fixed-price contract, with all work required to comply strictly with Title 49 CFR 180.205 and other applicable Department of Transportation regulations. The contractor must perform all services including safe discharge and reclamation of CO2, internal and external visual inspections for defects such as corrosion, dents, and thread damage, hydrostatic testing at specified pressures, measurement of expansion, and proper recertification labeling. All serviceable cylinders must be refilled to manufacturer specifications and returned to the dam’s powerhouse entrance, with pickup and delivery limited to Mondays through Thursdays between 7:00 a.m. and 3:30 p.m. local time, excluding weekends and federal holidays. The base line item, CLIN 0001, includes transport, evaluation, testing, reporting, and refilling of all cylinders, with an As-Found Inspection Report required prior to any additional work. This report must detail each cylinder’s condition, test results, valve status, and repair or replacement recommendations with estimated costs. No repairs or replacements—including valve rebuilds (CLIN 0002), valve replacements (CLIN 0003), full cylinder assembly replacements (CLIN 0004), or cylinder-only replacements (CLIN 0005)—may proceed without written government authorization. Optional CLINs have not-to-exceed prices of $20,000 per unit and are contingent on the findings of the preliminary inspection. All new cylinders and assemblies must meet DOT and manufacturer standards, include required markings and protective caps, and be secured with proper transportation restraints. The U.S. Army Corps of Engineers retains the right to inspect cylinders before release and upon return, verifying proper documentation, recertification marks, physical condition, and valve installation. The contract is a total small business set-aside with a performance period running through August 31, 2026, and all invoicing must be submitted electronically through the Wide Area WorkFlow system. Payment and technical oversight are managed by designated Corps personnel, and contractor access is restricted to public areas at the dam with no security clearance required.

General Info

Inspection, testing, recertification, and transport of 48-62 CO2 cylinders for Albeni Falls Dam fire suppression.

Agency

Department Of Defense → W071 Endist SeattleView Agency

NAICS

811310 - Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and MaintenanceView NAICS

Place of Performance

Oldtown, ID, 83822, USA

Set-Aside

SBA

Documents

(5)

Amendment 0001 to Solicitation W912DW26QA036 for AFD CO2 Hydrostatic Cylinder Testing

PDFamendment

A.02 AFD CO2 Cylinder Testing SOW QASP 31March2026 UPDATED

PDFsow

26QA036 Revised SOW for CO2 Cylinder Hydrostatic Testing at Albeni Falls Dam

PDFsow

Kidde+HPCO2+Cylinder+System+TDSs.pdf

PDF

RFQ W912DW26QA036 - AFD CO2 Cylinder Hydrostatic Testing

PDFrfq

AI Contract Breakdown

Uniform Contract Format

Sign up to view the full breakdown with detailed analysis of each section.

Timeline

1 update
PhaseClosed
Posted

Solicitation

Amendment 1

Contract was updated

Response Deadline

Deadline has passed

Submission Closed

Find active opportunities like this

Start your free trial to discover similar active contracts, track opportunities, and build proposals with AI assistance.

Organization & Contact Information

Show more
AgencyDepartment Of Defense → W071 Endist Seattle
Contacts2 people available
OfficeSEATTLE, WA, 98134-2329, USA
Organization / Agency
Department Of Defense → W071 Endist Seattle
View Agency Profile
Office AddressSEATTLE, WA, 98134-2329, USA

Full Description

Show more

UPDATED Scope of Work
CO2 Cylinder Inspection, Hydrostatic Testing, and Recertification Albeni Falls Dam | Seattle 
U.S. Army Corps of Engineers


1. General
The purpose of this contract is to provide inspection, hydrostatic testing, recertification, repair, replacement, transportation, and refilling services for high-pressure carbon dioxide (CO2) cylinders utilized in the fire suppression systems at Albeni Falls Dam (AFD).


The Contractor shall furnish all labor, supervision, materials, equipment, transportation, permits, and incidentals necessary to perform the services specified herein.


2. Description of Services
The Contractor shall provide pickup, transportation, inspection, hydrostatic testing, recertification, repair, replacement, refilling, and return delivery of CO2 cylinders and associated valves in accordance with applicable federal regulations and industry standards.
All cylinder inspections, testing, and recertification activities shall comply with the requirements of Title 49, Code of Federal Regulations (CFR), Section 180.205, Requalification of Specification Cylinders, and all other applicable Department of Transportation (DOT) regulations.


3. Contract Type
Firm-Fixed-Price (FFP) with separately priced Contract Line-Item Numbers (CLINs) for repair and replacement actions, as approved by the Government. 


4. Background
The CO2 cylinders covered under this contract provide fire suppression protection for electrical power generation equipment at Albeni Falls Dam. The fire suppression system consists of forty-eight (48) active 75-pound CO2 cylinders. A minimum reserve inventory of forty-eight (48) cylinders is maintained. An additional fourteen (14) cylinders may be available for inspection and evaluation. The total quantity of cylinders requiring service under this contract is estimated to be between forty-eight (48) and sixty-two (62) cylinders.


5. Period of Performance
The Contractor shall commence performance upon contract award and complete all work no later than 31 August 2026.


6. Place of Performance
Pickup and delivery shall occur at:
Albeni Falls Dam Powerhouse Entrance 2376 East Highway 2
Oldtown, Idaho 83822


Pickup and delivery shall occur only Monday through Thursday between 7:00 a.m. and 3:30 p.m. local time. No pickup or delivery activities shall occur on Fridays, weekends, or Federal holidays. AFD personnel will stage cylinders at or near the public entrance to the powerhouse for Contractor pickup.


7. Contract Line Item Numbers (CLINs)



CLIN 001 – Transport, Evaluation, Hydrostatic Testing, Reporting, Recertification, and Refilling


The Contractor shall:
•  Take custody of a minimum of 48 and a maximum of 62 CO2 cylinders.
•  Transport cylinders to the Contractor's facility.
•  Safely discharge and reclaim CO2 from each cylinder.
•  Remove and inspect each valve.
•  Conduct internal and external visual inspections of each cylinder.
•  Inspect for corrosion, pitting, dents, gouges, thread damage, and other defects.
•  Perform hydrostatic testing in accordance with 49 CFR 180.205.
•  Test cylinders at the required requalification pressure.
•  Measure total and permanent expansion.
•  Identify cylinders that fail testing requirements and designate them as unserviceable.
•  Evaluate valve condition and determine whether rebuilding or replacement is required.
•  Refill all serviceable cylinders to manufacturer-recommended fill capacity.
•  Affix required recertification markings and labels.
•  Return all serviceable cylinders to Albeni Falls Dam.


As-Found Inspection Report


The Contractor shall provide an As-Found Inspection Report identifying each cylinder by serial number and/or existing recertification stamp.


The report shall include:
•  Cylinder identification number.
•  Inspection findings.
•  Hydrostatic test results.
•  Serviceability determination.
•  Valve condition.
•  Recommended repair or replacement actions.
•  Estimated costs associated with repair or replacement recommendations.


The Contractor shall submit the report to the Government Technical Point of Contact prior to performing any repair or replacement work beyond CLIN 001.


Repair Authorization
No repairs, valve replacements, cylinder replacements, or cylinder assembly replacements shall be performed without written Government authorization. The Contractor shall provide a detailed proposal identifying the affected cylinder(s), and 
recommended quantities of rebuild/replacement needed for Optional CLINs 0002-0005. Government approval shall be obtained before proceeding with CLINs 0002 through 0005.


Recertification Documentation
Upon completion, the Contractor shall provide recertification documentation for each cylinder and valve assembly including:
•  Cylinder serial number.
•  Hydrostatic test date.
•  Test results.
•  Work performed.
•  Serviceability determination.
•  Recertification date.
•  Technician or testing facility identification.


Optional Item CLIN 0002 – Rebuild Kidde Type I Valve 


The Contractor shall rebuild existing Kidde Type I valves determined to be repairable. Amount is based upon the As-Found Inspection Report.


Rebuild services shall include replacement of worn seals, gaskets, springs, and other internal components as required to restore the valve to serviceable condition.


Optional Item CLIN 0003 – Replace Kidde Type I Valve


The Contractor shall furnish and install a new Kidde Type I valve when rebuilding is not feasible or economically advantageous.
Replacement valves shall be new and fully compatible with existing cylinder assemblies and fire suppression system requirements.


Amount is based upon the As-Found Inspection Report.


Optional Item CLIN 0004 – Replace Complete 75-Pound Cylinder Assembly


The Contractor shall furnish a new complete cylinder assembly including:
•  New 75-pound CO2 cylinder.
•  New valve assembly.
•  Required markings and certifications.
•  Protective cap.


The assembly shall meet all applicable DOT and manufacturer requirements.


Amount is based upon the As-Found Inspection Report.


Optional Item CLIN 0005 – Replace 75-Pound Cylinder Only


The Contractor shall furnish a new 75-pound CO2 cylinder without valve. The cylinder shall be compatible with existing Kidde Type I valves and comply with all applicable DOT requirements.


Amount is based upon the As-Found Inspection Report.


8. Quality Assurance
The Government Quality Assurance Representative (QAR) shall inspect cylinders prior to release to the Contractor. Upon return, the Government will verify:
•  Required recertification markings.
•  Documentation completeness.
•  Physical condition of cylinders.
•  Proper valve installation.
•  Required safety labels and identification markings.


The Government reserves the right to reject improperly tested, documented, or certified cylinders.


SEE ATTACHED: UpdatedScope of Work and Price Schedule in Amendment.

More opportunities from Department Of Defense → W071 Endist Seattle

Same awarding agency

NAICS: 53112
New
Federal
DACA675270000900 - United States Army Corps of Engineers (USACE) seeks to lease approximately 3,676 gross square feet of retail space in Gresham, Oregon for an Armed Forces Career Center (Military Recruiting Office) Notice ID: DACA675270000900
Solicitation # DACA675270000900
The United States Army Corps of Engineers (USACE) is seeking to lease approximately 3,676 gross square feet (3,192 net square feet) of ground-floor retail space in Gresham, Oregon, to establish an Armed Forces Career Center. The desired space must be located within a specific delineated area bounded by NW Division St, U.S. Hwy 26, SE 242nd Ave, and NW Eastman Parkway. The government requires a full-service lease for a five-year term, which includes base rent, common area maintenance, utilities, and janitorial services. The facility must provide nine government parking spaces available 24/7 and be situated in a professional retail setting with accessible public sidewalks and proximity to public transportation. To be eligible, the space must meet strict criteria, including being outside the 100-year flood plain and away from establishments selling alcohol, firearms, or marijuana. The interior must be conducive to an efficient layout, with specific restrictions on column size and placement. Offers must be submitted electronically by October 05, 2026, and must include a completed Rental Proposal Worksheet, a Lessor's Annual Cost Statement, and evidence of ownership. All offerors must be registered in the System for Award Management (SAM) at the time of award. The selection process will be based on the best value, taking into account costs, location, and past performance.

POSTED

2 days ago

DEADLINE

in 24 days
View Details

Find Active Opportunities Like This

Get AI-powered intelligence on the opportunities still open

Every page of the solicitation package shredded into a compliance breakdown

AI-powered matching based on your capabilities and past performance

Competitor and incumbent history on the requirement

Automated alerts on amendments, Q&A deadlines, and award

Miguel
Hillary
Keith Deutsch
Christine

Join 650+ contractors already using CLEATUS